Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
17 Sept 2026, 5:00 pm
OFFICE OF THE SUPERINTENDING ENGINEER
River Bank Colony Lucknow
Investigation Survey On GIS Basis and construction of 200 KLD 300 KLD and 400 KLD STP with 4 KLD co treatment 18 no leach pit each capacity 10 KLD I and D structure and Drain work in Nagar Panchayat Mahona Distt Lucknow
2026_UPJNM_1179863_1
2094/M-13/164
Open Tender
Civil Works
Percentage
730 days
Lucknow
Please refer tender document
2 documents required · 2 mandatory
₹11,800
Yes
Executive Engineer Construction Division III UPJNU
₹2.9 L
Yes
OFFICE OF THE SUPERINTENDING ENGINEER
26 Aug 2026
26 Aug 2026
18 Sept 2026
26 Aug 2026
17 Sept 2026
26 Aug 2026
7 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, construction,testing and commissioning of 200 kld Capacity STP/WSP(Prefer nature based technology) at Mahona Nagar Panchyat,Distt-Lucknow with all necessary units, internal & external electrification, piping etc complete including E&M works as per approved design and technical specifications and Pre-Treatment (Latest Independent Technology). The cost includes cost of suitable foundation, Inlet chamber, pre-Treatment units (including one stand-by unit), Primary/Secondary treatments, Disinfection, Disposal of treated sewage by gravity, The Cost also includes other all required civil, electrical, mechanical instrumentation with all related works to ascertain effluent parameters as per prevalent NGT/MoHUA/ MoEFFC norms.Desired effluent parameters should be BOD<10mg/l, TSS< 10mg/l, N<10mg/l, Fecal Coliform<100 & COD<50mg/l . | - | sqm | 16,31,150 | - |
| 2 | Design, construction,testing and commissioning of 300 kld Capacity STP/WSP(Prefer nature based technology) at Mahona Nagar Panchyat,Distt-Lucknow with all necessary units, internal & external electrification, piping etc complete including E&M works as per approved design and technical specifications and Pre-Treatment (Latest Independent Technology). The cost includes cost of suitable foundation, Inlet chamber, pre-Treatment units (including one stand-by unit), Primary/Secondary treatments, Disinfection, Disposal of treated sewage by gravity, The Cost also includes other all required civil, electrical, mechanical instrumentation with all related works to ascertain effluent parameters as per prevalent NGT/MoHUA/ MoEFFC norms.Desired effluent parameters should be BOD<10mg/l, TSS< 10mg/l, N<10mg/l, Fecal Coliform<100 & COD<50mg/l . | - | sqm | 0.61 | - |
| 3 | Design, construction,testing and commissioning of 400 kld Capacity STP/WSP(Prefer nature based technology) at Mahona Nagar Panchyat,Distt-Lucknow with all necessary units, internal & external electrification, piping etc complete including E&M works as per approved design and technical specifications and Pre-Treatment (Latest Independent Technology). The cost includes cost of suitable foundation, Inlet chamber, pre-Treatment units (including one stand-by unit), Primary/Secondary treatments, Disinfection, Disposal of treated sewage by gravity, The Cost also includes other all required civil, electrical, mechanical instrumentation with all related works to ascertain effluent parameters as per prevalent NGT/MoHUA/ MoEFFC norms.Desired effluent parameters should be BOD<10mg/l, TSS< 10mg/l, N<10mg/l, Fecal Coliform<100 & COD<50mg/l . | - | sqm | 0.19 | - |
| 4 | Survey,Design,Investigation, construction,testing and commissioning of 4 kld Capacity Co- Treatment (FSTP) at Mahona Nagar Panchyat,Distt-Lucknow with all necessary units, internal & external electrification, piping etc complete including E&M works as per approved design and technical specifications and Pre-Treatment (Latest Independent Technology). The cost includes cost of suitable foundation, Inlet chamber, pre-Treatment units (including one stand-by unit), Primary/Secondary treatments, Disinfection, Disposal of treated sewage by gravity, The Cost also includes other all required civil such as Planted Dying Bed,Collection Tank,Anaerobic Baffaled Reactor, Planted Gravel Filter , POLISHING POND,Sludge Storage House , Gaurd Room ,Boundary Wall with Gate , electrical ,mechanical instrumentation with all related works to ascertain effluent parameters as per prevalent NGT/MoHUA/ MoEFFC norms. | - | sqm | 0.65 | - |
| 5 | Survey,Design,Investigation, construction,testing and commissioning of 10 kld Capacity Leach Pits at various Locations of Mahona Nagar Panchyat,Distt-Lucknow with all necessary units, , piping etc complete as per approved design and technical specifications . The cost includes cost of suitable foundation, Inlet chamber, pre-Treatment units The Cost also includes other all required civil works such as House Connection with all House Holds,Utility Shifting , repairs , Crossing of drains,Dismentling of Ramp ,drain,Roads and Reistatement of same previous Condition. | 18 | sqm | 0.29 | ₹5.23 |
| 6Survey,Design,Investigation, Construction,testing and commissioning of various sizes Intercepting masonary drain with RCC Cover and CC faoundation as per approved Drawing suitable for Site Condition various Locations of Mahona Nagar Panchayat,Distt-Lucknow . | |||||
| 6.01 | (Cross Section 0.60 x 0.6 m) | - | no | 1 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.73 MB
Document.pdf
Tender Documents • 11.18 MB
BOQ_2218603.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].