Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC 121004 | L1 | Accepted-AOC Being lowest tender reasonable | |
| 2 | L2₹49.7 L+₹15,081.75 (0.30%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.8 L+₹24,199.23 (0.49%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹51.1 L+₹1.5 L (3.05%)Rejected-Finance 31 CHAIRMAN KARUPPANA THEVAR STEET SULUR COIMBATORE 641 402 | COIMBATORE | TAMIL NADU | 641402 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹51.3 L+₹1.7 L (3.41%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
20 Jul 2022, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF RAIN SHELTER SLOPING SHEDS, FIXING OF NEW CLOTH LINE IN EXISTING MD ACCN (OMQs) INCLUDING CERTAIN SANCTIONED/ MINOR WORKS AT AF STN SULUR
2022_MES_534667_1
8489/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,800
Yes
2 Aug 2022
29 Jun 2022
21 Jul 2022
29 Jun 2022
20 Jul 2022
14 Jul 2022
29 Jun 2022 - 9 Jul 2022
Amount
SCHEDULE A BOQ
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240) complete all as specified and as directed
M&L Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L MS Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolt etc posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over one coat of red oxide primer complete all as specified and directed.
M&L Preparation of new or previously untreated steel surfaces of any description, under 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over one coat of red oxide primer complete all as specified and directed
Note for item No 5 & 6 :- (a) All synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L Pre painted Coloured Mangalore Tiles profile Galvalume sheet 0.40 mm thick having Zinc aluminium alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed any colour having tensile strength of 550 Mpa as in Roof covering with crimping / cladding to wall fixed with self tapping screws complete all as directed by Engineer-in-Charge.
S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Note for Item No 15 to 17 (Pre-painted coloured Galvalume roofing) :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensure that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 30cm long and diameter of neck in n exc 12 mm complete all as specified and directed.
S & F Stainless steel (Gde 201) wire rope 4mm dia to existing frame/ brackets for drying & hanging clothes in indoor and outdoor complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, in hard / dense soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L Plain Cement Concrete 1:4:8 type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L Plain Cement Concrete 1:3:6 type C2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board (Lake & Hill) all as per Everest regular T-2430 or equivalent, complete all as directed. (Make Ramco/Charminar/Armstrong).
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed
Note for Item No 28:- The quoted rate deemed to be inclusive for the following:-
(a) Excavating either straight or curved on plan
(b) Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance except in the case of surface dressing which includes for all the foregoing except clearing away of trees
(c) Bailing out, pumping out or otherwise removing all water which may accumulate in the excavations
(d) Setting out the work profiles, etc. as well as for all tools and plant
(e) All materials and labour required for protecting against risk of accidents, etc.
(f) Watching and lighting, whenever necessary.
(g) Forming (or leaving) ‘Dead men’ or ‘Tell tales’ in borrow pits and their removal after record of measurements where required
(h) Forming (or leaving) steps in sides of deep excavations and their removal or covering up, after record of measurements
(j) Excavation for insertion of planking and strutting where necessary
(k) Removing slips or falls in excavations
(l) Authorised battering or benching of excavations
(m) Slinging or supporting pipes, electric cables, etc. met with during excavation
M&L Brickwork with fly ash bricks using old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed
Note for Item No 42 :- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.
(b) The rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall.
(c) Sinking of steining shall be measured separately under relevent item. Well curbs, tie-rods, etc. shall be measured under the appropriate item.
(d) bricks shall be of class designation 75 (Kgf/cm).
(e) The quoted rate shall be deemed to be inclusive for all scaffolding, ladders, plant and templates required
(f) Exposed faces of brick work shall be fair.
(g) Exposed faces shall be facing with best bricks
(h) The quoted rate shall be deemed to be inclusive for Plumbing to angles
(j) Forming reveals to jambs where fair cutting on exposed faces shall not be involved
(k) The quoted rate shall be deemed to be inclusive for preparing tops and sides of existing walls and the like for raising and extending
(l) Building in vertical seismic reinforcement at the jambs of openings, corners of walls, etc.shall be grouting in cement mortar 1:4
M&L Rendering 15 mm thick on brick or stone or concrete surfaces, in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Note for Item No 54 :- The quoted rate shall be deemed to be inclusive for the following:- (a) Preparing the surfaces.
(b) Thickness of plaster key in joints, etc
(c) Scoring surface of plastering for key, where the surface is not required to be finished fai
(d) Curing of plastered surface.
M&L applying two coats of cement based paint over a coat of primer including preparation of new plastered wall surfaces of any description, complete all as specified and as directed.
Note for Item No 59:- (i)Before applying cement based paint ,the surface shall be thouroughly wetted to control surface suction. The surface shall be moist but not dripping wet when the paint applied .Surfaces which readily absorb moisture shall be wetted in one operation not more than one hour before painting.Surfaces which absorb moisture slowly shall be wtted in at least two operations not less than 30 minutes apart.
(ii)To maintain a uniform mixture and to prevent segregation ,the paint shall be stirred frequently in the bucket.
(iii)Painting surfaces shall be cured as soon as paint has hardened so as not be to damaged by the spray about 12 hours after the applications.
(iv) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
(v)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified and as directed.
Removing excavated soils to a distance exceeding 1.5 KM but not exceeding 5KM and depositing where directed complete all as specified and directed.
M&L Glazed ceramic coloured tiles 450 x 300 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado, laid over and including backing coat with cement mortar 10 mm thick in CM 1:3 complete all as specified and directed.
S&F Bib Cock with wall flange screwed down screwed for iron pipe in repairs 15mm bore complete all as specified and as directed. Make as per CAT Part No CQT -23047 of Jaquar or equivalent to /Parryware/Hindware/Cera
S&F Angular stop cock, valves high pressure screwed both ends iron pipe or for unioins 15mm dia, CAT Part No G3007A1 of Parryware or equivalent to Hindware/Cera complete as directed by Engr-in-charge.
S&F Doom grating 125 mm dia with waste hole of PTMT(minimum weight 40gms) complete as directed by Engr-in-charge.
S&F CP sink cock with swinging casted round shape spout screwed down screwed for iron pipe in repairs 15mm bore including taking down existing one complete all as specified and as directed. (Make :CAT Part No-CQT-23347 of Jaguar or equivalent Parryware/ Hindware
S&F Sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed complete all as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA.
S&F 40mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm for WHB complete all as specified and as directed.
S&F 25mm dia mild steel powder coated drapery rod out to length required without joint in between and fixed at openings Including taking down existing one complete all as specified and as directed by Engneer-in-Charge
S&F Mild steel powder coated brackets for holding the drapory rod and fixed to wall with MS screw complete all as specified and as directed.
S&F Mild steel powder coated fancy type brackets fixed at both the end of drapery rod of same colour and type of drapaery rod complete all as specified and as directed by Engneer-in-Charge
S&F CP Hand shower (Health Faucet) with 1M Flexible tube with 8mm dia wall hook with NRV (Back flow preventor) complete all as specified and as directed. Make as per CAT Part No ALD CHR-579 Jaquar or equivalent in Parryware, ESS-ESS
S&F 20 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20oC) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, KPT, Prince
S&F 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20oC) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, KPT, Prince
Note for item No 78 & 79:- (a) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b ) Wall thickness of pipes shall be all as per IS : 15801
S&F 25 mm outer dia PPR gate valve (brass insert) incl taking down existing one comlete all as specified and directed
S&F CP 2 way bib cock with wall flange fancy type screwed down screwed for iron pipe in repairs 15mm bore CAT Part No-Sl. No-CQT-23041 Jaquar or equivalent in Parryware ,or as per list of makes complete all as specified and as directed by Engineer-in-Charge
S&F PVC (SWR) bends 75mm bore complete all as specified and as directed by Engineer-in-Charge
S&F PVC (SWR) pipes single socket in any length with rubber ring joints of 75 mm bore fixed to wallincluding fittings like clamps etc complete all as specified and as directed by Engineer-in-Charge
Supply, laying and testing cableXLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 300 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, all as specified and directed. Note :- Excavation and earth work shall be measured and paid seperately. Make : KEI/NICCO/Havells
Supply and installation of copper wound transformer 250 KVA, 0.433/11 KV, 3 Phase, 50 Hz, ONAN cooled oil immersed copper wound indoor type step up transformer complete with first filling of IS: 335 ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (Tapping Range +7.5% in steps of 2.5 % each) with vector group dyn-11 complete alla as specified and directed. Make : Indian Transformers or equivalent make specified in PS
Supply, install, testing and commissioning of Vaccum circuit breaker panel board 11 KV, 630 Amps, 25 KA, 3 Phase, 50 Hz, AC Supply system, Outdoor type metal and clad totally enclosed free standing floor mounted type suitable for housing trolly mounted vaccum circuit breaker, horizontal isolation and horizontal draw out type,cubicle should be IP 65 class degree of protection 600 Amps rated copper busbar complete and comprising of the following specification :- Make : Indian Transformers or equivalent make specified in PS
(A) PANEL:- should be comprising trolly mounted horizontally isolated, horizontally draw out type VCB 11 KV,630 Amps capacity, 25 KA completely enclosed with provision of mechanical locking and having 3 Nos vaccum interrupters of ratings 11 KV, 630 Amps, 25 KA capacity mounted on common phase segregated epoxy body for higher elect insulation and to maintain pole discrepancy as per IEC 56 and self alligned type isolating contacts,manual and motor operating (230 volt AC spring charged mechanism, manual closing and tripping push buttons, emergency trip push button, mechanical indication for circuit breaker close/open, mechanical operation counter, 08 No +08 NC breaker operating auxillary switch, spring charged/discharged indication, circuit breaker service/test position indication etc and with the following accessories :-
(i) Floor mounted panel fabricated with 3 mm thick CRCA sheet duly powder coated with self contained air insulated compartments for bus bars and cable boxes with necessary supports.
(ii) Fixed spout insulators with effectively covered by safety shutters automatically open/close while draw in/draw out operations.
(iii) 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system in closed position for earthing/maintenance purpose.
(iv) An epoxy interupter per phase all as per manufacturers design.
(v) The breaker with self contained motor charging asembly includes 230 V AC motor and control switches. Also should have standard safety interlocks and locking facilities. A mechanical operating connector lever and extendable rails to easily draw out/in the VCB trolly from the panels is also to be provided.
(vi) Instrumentation panel comprising of the following :-
(a) Microprocessor based 2 element over current and 1 element earth fault and high set IDMT relay- 01 No, Master trip relay - 01 No . Make: L & T/ Alstom/ ABB/ Ashida/ ER/ Seimens.
(b) Digital type frequency meter. Make: MECO/ AE/ HPL.
(c) Digital type Ammeter. Make : AE/MECO/L&T.
(d) Resin cast current transformers, 11 KV ratio, 100/50, 5 Amp, 15 VA burden,class 1 accuracy for metering and 15 VA/5p 10 for protection - 03 Nos.
(e) Digital type volt meter. Make : AE/ MECO/ L&T.
(f) Electrical closing coil 24 volt DC operated - 01 set.
(g) Electrical shunt trip coil 24 volt DC operated - 01 set.
(h) TNC switch - 01 No.
(j) Local and remote control switch with locking arrangement - 01 No.
(k) Indicating lamps LED type for emergency tripping, spring charged, breaker ON and OFF,breaker service position,trip circuit healthy with push button - 01 set.
(l) Control wiring with copper conductor flexible cable 4 sqmm for CT wiring and 2.5 sqmm for other control wiring.
(m) Strip type heater 80 watt, with thermostat control and switch for breaker compartment and CT compartment - 01 set.
(n) Mech (caster lock) and elect inter locking sys- 01 set.
(B) BATTERY BANK WITH CHARGER FOR AUXILLARY SUPPLY - 01 SET. Battery bank 24 volt consisting of 02 Nos 100 AH, 12 volts cells, maint free lead acid alongwith Racks & connections with suitable rating copper bus bar covered with PVC sheet and suitabale rating of float cum boost battery charger of rating 230 volt AC i/p, protection for i/p & o/p. 2 core, 10 sqmm, copper conductor un-armured cable (25 RM Approx) with crocodile clamps/lugs on ends from LT Panel to charger for 230 volts AC Supply and battery charger to VCB panel. Make : Exide/ Amarraja/ HBLNIFE
(C) ALARM SYSTEM :- Common alarm with reset sys to be provided on panel bd for ckt breakers trip, DC auxilary supply failure and AC auxilary supply failure.
(D) 230 VOLT AC AUXILLARY SUPPLY:- 2 Core,10 sqmm,copper conductor, un-armoured cable from LT panel/DB to VCB panel bd 25 RM (Approx).
(E) Supply and fixing/Connecting out door type 11 KV Singel phase Resin cast dry type PT of ratio 11KV/√3/110V/√3 class 0.5-3, Burden 100VA insulation level 28KV/75KV voltage factor 1.2 Cont and 1.9 for 30 sec,confirming to IS-3156 - 3 Nos
Note for item No 88 :- Cost for suitable base platform/foundation as per OEM recommendations is deemed to be included in the unit quoted rate.
Material and labour, earthing complete with copper earth plate electrode of size 600mm x 600x 3.15 mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level),with top edge of earth plate not less than 1.5m below normal ground level, eart plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, magnesium sulphate (1 : 1 : .5), electrode connections using copper strip of size 20 x 3 mm thick (upto body of equipment) by means of brazing / welding conencted to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40mm dia bore nd watering pipe 20mm dia bore GI medium grade with funnel and wire mesh including all neesary(excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in elctrical plate No 3 of MES schedule Part-I (2009), testing on completion, complete all as specified and directed.
Notes for Item No 114:- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM not less than 4Kg/ Sqm.
(ii) PCC pit cover shall be constructed 500mm away from the edge of eath pit.
(iii) Rate shall include Copper strip and protection pipe of length 7.5m, excess beyond 7.5m lenth required at site shall be measured and paid separately.
(iv) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.
(v) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vi) Earth resistance should be less than 3 Ohm, In case the test results are not found below 3 Ohm, complete earthing will redone without any extra cost to Govt.
S&F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. Note : All Joints should be joined by Exothermic Welding or Brazing.
Supply, of factory made LT cubical panel indoor type made up of 3.15 mm thick CRCA sheet weather, dust & vermin proof, double door, front & back opening detachable type complete made up of suitable angle iron frame with locking arrangement duly mounted on angle iron frame of suitable size grouted on PCC plinth, painted with two coats of powder coating over a coat of red oxide primer conforming to IS 8623, IP 54 protection including necessary glands etc at the bottom sheet cover and consisting of the following items:-
Incoming :- (a) MCCB with Thermal Magnetic Release, 4 pole, 415 Volt of capacity 400 Amps, 36 KA - 1 No.
(b) LED indicator lamps (R,Y,B) - 01 Set
(c)Busbar chamber 630Amps capacity mounted on porcelain insulator Aluminium strip insulated complete alongwith internal wiring for measuring instruments.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
Supply and laying in trenches/through pipes or bare in road crossings/paths/ drains/ ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11 KV grade, of cross sectional area 185 Sqmm x 3 core complete all as specified and directed. Note :- Excavation and earth work shall be measured and paid seperately. Make : RPG Asian, Havells, Polycab
eurekaenterprises
KSR AND COMPANY
kaarthic builders
KUMAR AGENCIES
A.GOVINDARAJ
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .