Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.5 Cr+₹25,860.50 (0.17%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹1.5 Cr+₹25,860.50 (0.17%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹1.6 Cr+₹14.3 L (9.53%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹1.6 Cr+₹14.3 L (9.53%) | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
11 Jan 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
COMPREHENSIVE MAINTENANCE OF CERTAIN BUILDINGS AT VARUNAPURI UNDER GE NW VASCO
2020_MES_401376_1
85323/E8
Open Tender
Civil Works
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE NW VASCO
₹2.2 L
Yes
11 Mar 2021
7 Dec 2020
13 Jan 2021
7 Dec 2020
11 Jan 2021
28 Dec 2020
Amount
Schedule 'A' Part I - B/R portion
M&L for taking down loose and damaged concrete cement plaster from soffit of ceiling floor/slab, vertical surfaces of column beams,slab etc including exposing and removing rust from reinforcement by rubbing with wire brush and plenty of water so as to remove the loose particles,dust,laitance etc. and removal of debris to a distance n.exc 50m and deposited where directed all as specified and as directed.
M&L for applying one layer of concrete 40mm thick comprises composition 50 Kg cement ,3 to 6mm chips 100 Kg, sand 50 Kg mixed with spray set SL 3 to 2.5 by weight of cement and 12.5 to 16.5 litres of water mixed with admixture including bonding agent and applying rust remover and gunitting with pressure nozzle with a delivery capacity of 2.5 Kg/Sqm all as specified and as directed.
All as per item No 2 here in before, but 30 mm thick as in beam all as specified and as directed.
All as per item No 2 here in before but 20 mm thick as in ceiling all as specified and as directed.
Supply only welded steel wire fabric weight n exc 4 kg per sqm all as specified and as directed.
M&L for CRS TMT steel bars 8mm dia, cut to length, bent to shape required and welded to existing reinforcement of any description and any position of RCC structure after binding with mild steel wire annealed n less than 0.9 mm dia as an additional bar complete all as specified and as directed.
M& L for CRS TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
M & L for providing 10mm thick Ready mix plaster finished to even & smooth without using extra cement over gunniting surface all as specified and as directed.
M & L for providing ready mix plaster 5mm thick on ceiling finished even and smooth without using extra cement over gunniting surface all as specified and as directed.
Dismantling/taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface or RCC slab including removing the dismantled debris to a distance exc 200m & n exc 250m all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab, filling the crack upto 2mm wide with approved make maintaining a suitable slope for water drainage and reinstate damaged portion with polymer modified mortar as recommended and allow it to cure for 24 hrs. Brush apply the 1st Priming coat on prepared concrete/plastered surface and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
Note: Crack filler, priming coat and water proofing coat used shall be of same Make/Manufacturer.The quoted rate deemed to be inclusive of crack filling,minor repair required for making the surface smooth,repair mortar for damaged portion. Application to be done through authorized applicator of the manufacturers only.
Taking down cement plaster of any description on brick or stone walls including racking out joint, hacking for key, scrubbing down with water et complete all as specified and as directed.
M&L for 15mm thick READY MIX PLASTER of approved make on external wall surfaces complete all as specified and as directed.
M&L for 10mm thick READY MIX PLASTER of approved make on internal wall surfaces complete all as specified and as directed.
M&L for 5mm thick READY MIX PLASTER of approved make on ceiling complete all as specified and as directed.
M&L for preparing newly plastered external wall surface and applying two coats of water proofing treatment with araldite builder barrier coat of approved make @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed by Engineer-in-Charge all as specified in manufacturer's instructions and to be applied through applicator of authorised manufaturer with 5 Years guarantee all as specified and as directed.
M & L for preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer all as specified and as directed.
M&L for 3mm thick wall care putty on wall and ceiling all as specified and as directed.
M & L for preparing newly plastered surface of ceiling and applying two coats of oil bond distemper over a coat of alkali resistant primer all as specified and as directed.
M&L for applying one coat of synthetic enamel paint on old treated surface of wood or wood based material over 10 cm width or girth including preparation of surface complete all as specified and as directed.
M & L for complete removal of old existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant primer on wall surfaces complete all as specified and as directed.
M & L for complete removal of old existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant primer on ceiling complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc,complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
M & L for rendering 10mm thick cement mortar 1:4 on fair faces of stone masonry wall surfaces, finished even and fair to receive glazed tiles all as specified and as directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor tiles all as specified and as directed.
M&L for providing adhesive for fixing floor tile all as specified and as directed.
M & L for glazed ceramic tiles 300 x 200 x 7mm thick coloured on vertical surfaces such as dado skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M & L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M & L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
Taking down chowkat/frame with shutters n exc 1.5 Sqm without taking off shutters from the frame all as specified and as directed.
All as per item No. 31 here in before, but exc 1.5 Sqm but n exc 4 Sqm each with shutters without taking off shutters from the frame all as specified and as directed.
Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm each and removing to store all as specified and as directed.
Taking down shutter exceeding 1 sq. m and not exceeding 2 sq. m each and refixing in same position all as specified and as directed.
M&L for 2nd class hard wood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
M&L for 2nd class hardwood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and as directed.
M&L for 2nd class hardwood factory made panel shutters of 35 mm thick all as specified and as directed.
M&L for preparation of new surface of wood or wood based material over 10 mm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
S&F solid PVC door frame of size 100mm x 45mm made out of 5mm prelaminated PVC sheet reinforced with MS square tube, fixed in position all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with prelaminated colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelaminated sheet PVC sheets for top rail, lock rain & bottom rail panelling of plain gap insert for top rail & bottom rail paneling of prelaminated PVC sheet 10mm to be fitted in the MS frame selded/sealed to the stiles & rails (stiles and rails feathered at edge) with suitable PVC sheet beading and jointed together with solvent cement in the frame at site as per specification & drawing all as specified and as directed.
S&F aluminium powder coated barrel tower bolts of extruded section 150 mm long all as specified and as directed.
S&F Aluminium alloy powder coated sliding door bolt 300 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and as directed.
S&F stainless steel Butt hinge 100mm size all as specified and as directed.
S&F extruded aluminium alloy, fabricated type handle, powder coated 150mm long all as specified and as directed.
S&F in repair stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.4mm cut to size and fixed to doors/window shutters and fixed with aluminium wire staples as ordered all as specified and as directed.
S&F mild steel works as in bands, straps, clamps hold fasts and similar small articles conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
S&F Aluminium powder coated window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S &F Aluminium powder coated grill model / design no DG 104 ( 10 mm thick ) with DL-102 frame all as specified and as directed.
S &F Sheet pin headed figured glass ordinary quality ,4 mm thick and glazing with oil putty /wooden / metal beads in squares not exceeding 0.5 Sq m each all as specified and as directed.
All as per Item No 49 here in before, but exceeding 0.5 sqm each pane all as specified and as directed.
Taking down existing aluminium window shutters with frame n exc, 2.00 Sqm each and refixing the same after necessary repair including cleats, handles etc excluding wire mesh / glass pane. Note :Wire mesh / glass pane shall be measured and paid seperately under respective items.
M&L for machine cut Kota stone slab 18-25 mm as in window cills, etc laid over cement screed bed jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying kota stone slab as in cill and kitchen platform marble all as specified and as directed.
M&L for 18 mm thick single side prelaminated wooden grain solid PVC sheet suitably fixed in shelves, partition and shelves of built in cupboard almirahs book cases, toilet, boxes , racks, pelmet and similar work including all hardware fittings all as specified and as directed.
M&L for 18 mm thick both side plain wooden grain solid PVC sheet suitably fixed in shelves, partition and shelves of built in cupboard almirahs book cases, toilet, boxes , racks, pelmet and similar work including all hardware fittings all as specified and as directed.
S&F solid PVC frame (single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing . Note:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
S&F kitchen sinks with drainage boards made of stainless steel 1mm thick with plugs, washers & wastes, including in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes over all size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified and as directed.
S&F stainless steel 1.0mm thick plate rack including fixing in walls with suitable screws, wooden plugs including all necessary arrangements etc complete all as specified and as directed.
M&L for marble work (Baroda green) 18-20mm thick (table rubbed or polished) as in cooking platforms, window cills, jambs, pillars etc with and including cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of marble all as specified and as directed.
S&F in repair Vitreous china coloured water closet European type with and including jet spray/faucet fixed including fixing with P trap all complete all as specified and as directed.
S&F vitreous china WHB, white, flat back, size 550mm x 400mm excluding taps, waste chain, and plug and porcelain stopper but including brackets all as specified and as directed.
M&L for waste fitting (PTMT) for glazed ware sinks, basins etc half or full threaded with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed for 32mm bore all as specified and as directed.
S&F in repair 15mm bore Bib tap cast copper alloy chromium plated long body fancy type screwed for CPVC pipe all as specified and as directed.
S&F in repairs 15 mm bore pillar taps, fancy type cast copper alloy, with capstan heads chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shank and fly-nuts, screwed for PVC pipe and fixed all as specified and as directed.
S&F gate valve PTMT, screwed down, high pressure with crutch or butterfly handle, screwed both ends for CPVC pipes 20mm bore all as specified and as directed.
S&F in repairs 15mm bore CP Angle stop valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and as directed.
S & F in repair PVC low/high level flushing cistern, 10 Ltrs capacity including float valve, chain, PVC flush pipe all as specified and as directed.
S&F grating dome 125mm dia with waste holes of PTMT Min wt 140 gms all as specified and as directed.
S&F in repairs PVC connections, 600mm long with brass CP/PTMT nuts suitable for connecting 15mm bore pipes, superior quality all as specified and as directed.
S&F in repair CP shower roses 125mm size, with or without swivel joint including fixing to steel pipe all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth in stone concrete block or slab walls all as specified and as directed.
Supplying & laying CPVC water tubing outer dia 20mm, SDR-11 grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and as directed.
All as per item No. 73 here in before, but for 25mm bore pipe all as specified and as directed.
Taking up or down steel water tubing 15mm bore and connections all as specified and as directed.
All as per item No. 75 here in before, but for 20mm bore pipe all as specified and as directed.
S&F 500 Ltr double layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position etc complete all as specified and as directed.
S&F 20mm dia brass ball valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed all as specified and as directed.
S&F 20mm bore brass Union to connect iron to polyethylene tank complete fixed all as specified and as directed.
Treating and finishing the sunken portion of WC area n exc 1.2 Sqm each by providing 10mm thick rendering in cement mortar 1:3 with and including water proofing compound and elastomeric membrane and applying two coats of bitumen, providing necessary connection items suitable for WC, providing lime concrete and 1mm thick multiplus plastifelt over 20mm thick plain cement concrete 1:2:4 type B0 using 12.5 mm graded crushed trap stone aggregate complete all as specified and as directed.
All as per item No 80 here in before, but for bath/lobby without any PVC connections/fitting, area exc 1.2 Sqm and n. exc 2 Sqm each all as specified and as directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and plastic cleats all as specified and as directed.
Supply only vitreous China squatting pan, 'Orrisa Pattern, size 580x440 white with integral foot rest all as specified and as directed.
S&F in repair curtain rails 19mm dia stainless steel with brackets stops rollers etc all as specified and as directed. Note: Size of bracket not less than 75mm long
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed.
Demolition of cement concrete of any description and in any position, not otherwise specifically provided for all as specified and as directed.
Demolition of existing cement concrete (reinforced) of any type and in any position not otherwise specifically provided for all as specified and as directed.
Dismantling structural steel work including doors, gates, railings but excluding framed truss etc all as specified and as directed.
M&L for 50mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate, finishing the surface even and fair as in plinth protections all as specified and as directed.
M&L for RCC Type B1 1:2:4 using 20mm graded stone aggregate as in slab supported on walls, beams, columns in floors, deck slabs and in shelves etc. all as specified and as directed.
S&F stair (framed) including stringers, treates, landing, balusters, hand rails etc including cleats, brackets etc complete (Fe 290 Gde E-165) all as specified and as directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n exc 200mm thick, horizontal or sloping, for rough finished surfaces all as specified and as directed.
M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W(Gde-E- 250) all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having Tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
Taking down PVC (SWR) pipes 75/110 mm bore from walls all as specified and as directed.`
M&L for UPVC pipe, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls all as specified and as directed.
All as per Item No 98 here in before, but for 110 mm bore all as specified and as directed.
S&F UPVC (SWR) bends 75mm bore any radius dismantling pieces or tapers all as specified and as directed.
All as per item No.98 here in before, but for 110mm bore all as specified and as directed.
S&F UPVC (SWR) branch piece, single, (Single Y) equal or unequal with access door, for 75 mm bore pipes all as specified and as directed.
S&F UPVC (SWR) branch piece, single, (Single Y) equal or unequal with access door, for 110mm bore pipes all as specified and as directed.
S&F UPVC (SWR) branch piece, double, (double Y) equal or unequal with access door, for 75mm bore pipes all as specified and as directed.
S&F UPVC (SWR) branch piece, double, (double Y) equal or unequal with access door, for 110 mm bore pipes all as specified and as directed.
S&F 110 mm dia UPVC (SWR) vent cowl all as specified and as directed.
S&F Nahani traps CI 75mm dia with grating including jointing to waste pipe, fixed in cement concrete type B1 1:2:4 all as specified and as directed.
S&F UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed.
S&F low density polythene (LDPE) pipes of pressure rating 6kg/sqcm of 32mm bore complete all as specified and as directed.
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as sub base all as specified and as directed.
M&L for sand(crushed stone) filling including spreading, levelling, watering and consolidation in layers n.exc 25cm all as specified and as directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver blocks (coloured) of any shape and size , M-35 grade laid over sand layer all as specified and as directed.
Excavation in trenches n.exc 1.5m in wide n.exc 1.5m depth, for foundations etc or for shafts, wells, cesspits, manholes getting out in soft/loose soil all as specified and as directed.
M&L for PCC 1:4:8, type D2 using 40mm graded stone aggregate as in foundation all as specified and as directed.
M&L for precast cement concrete block masonary 1:3:6 type C-1, using 20mm graded stone aggregate with solid blocks exc 10cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work on concrete surfaces in cement mortar 1:6 to be finished even and smooth without using extra cement all as specified and as directed.
M&L for returning filling including spreading levelling watering and well ramming in layers not exc 25cm all as specified and as directed.
S& F in repair CP jet spray/ health faucet complete all as specified and as directed.
M & L for drilling and fixing Teflon nozzles in RCC members, including drilling hole 12mm dia, 50 to 100 mm deep holes in structural members at the interval of 300 to 500mm in staggered manner or as directed by Engineer in charge in RCC structural element. Cleaning of holes by air blower prior to fixing nozzles. Inserting 12 mm dia Teflon nozzles in cleaned hole. External end of nozzles to be machine to receive outlet of grouting gun., fixing it inside the holes by applying thixotropic of approved make as specified to ensure complete sealing, curing the system for minimum 12 hours, cutting the nozzles by chiesel after completion of grouting without damaging the structure,complete all as specified and as directed.
M&L for injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer MONOPOL of approved make as specified by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including mixing of materials, mixing of material components (Part a & b) in the required quantities as per manufacturer's instruction by weigh batching, grouting (fill the grouting gun with concrete penetrating corrosion inhibitor of approved make to maintain the pressure at exit (2 to 3 kg/cm2) by monitoring pressure guage at exit, grouting the material through prefixed nozzles in the structural elements @ 100ml per nozzle, repeat the process for all the nozzles all as specified and as directed.
M&L for injecting at site, cement slurry grout, in the ratio 1:2 (1-Cement, 2-Water) including super plasticizer (Supercom-100) as specified 250 ml/50 Kgs bag. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/sqcm etc. complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled all as specified and as directed.
M & L for anticorrosive treatment by using approved make as specified to reinforcement by application of two coats on exposed reinforcement in two coats with time interval of minimum 4 (four) hour between each coat. The application shall be by brush all as specified and as directed. Note:- Exposed treated surfaces of reinforcement shall be measured.
Providing and applying structural grade epoxy latex bond coat of approved make as specified prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete / new cement mortar as per manufacturer's instructions, complete all as specified and as directed.
M & L for chiselling the crack to a 'V' groove of 10mm x 10mm for all type PCC & RCC surfaces, clean the groove to remove all loose plaster & wash with water and apply polymer bonding agent of approved make followed by flexible polymer based putty,complete all as specified and as directed.
Providing and applying jacketing around damaged member of columns with Micro concrete of approved make at level for thickness more than 40mm including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and as directed. Notes: Reinforcement shall be measured and paid separately.Rates including jacketing, formwork and micro concrete.
M&L for Building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (one part cement, 3 parts graded cleaned prepacked river sand, 10% latex mortar of approved make by weight of cement, water cement ratio 0.50 in 20 mm average thickness including leveling profliling etc.complete all as specified and as directed.
M&L for Building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (one part cement, 3 parts graded cleaned prepacked river sand, 10% latex mortar of approved make by weight of cement, water cement ratio 0.50 up to 40 mm average thickness each layer not exceeding 20 mm with epoxy latex based bond coat before every layer, including leveling profliling etc. complete all as specified and as directed.
S & F Sheet glass assembly consisting of 8 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long all as specified and as directed.
S & F in repair 150 mm ordinary pattern door spring all as specified and as directed .
S & F in repair door stopper of aluminium alloy body with rubber shoe 75 mm long all as specified and as directed.
S &F in repair 200 Ltr capacity PVC loft tank of rectangular type suitable to fix in kitchen all as specified and as directed.
S & F in repair 15 mm board CP stop valves screwed both ends for iron pipe or for unions and fixed all as specified and as directed.
S & F in repair 15 mm dia ball valves high pressure of PMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed all as specified and as directed. (Minimum weight 15 mm-142 gms)
S & F MS Framed work such as grills,gratings etc. with ends of bars shouldered and/or riverted ,or forged into spikes ;frames guard bars ; barred iron doors;ladders;framed balusters;walk ways ;railings ;framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed.
S & F aluminium angle as in nossing in stairs all as specified and as directed.
M&L for writing letters/bldgs Nos or figures (Block,Roman or indian) on wall 10cm height using synthetic enamel paint or circular/black painted,black background all as specified and as directed.
S & F stainless steel work as in staircase railing/balcony railing all as specified and as directed.
Dismantling stone slab of any description or thickness in floors, aprons laid bedded and pointed in any mortar all as specified and as directed.
Dismantling boarding ,any description,fixed in any position with nails all as specified and as directed.
Dismantling water tank exc 250 ltr and not exc 500 ltr capacity and removing to store all as specified and as directed.
Dismantling water tank not exc 250 ltr capacity and removing to store all as specified and as directed.
Schedule 'A' Part II - E/M portion
Taking down aluminium/copper point wiring (light, fan, socket or power ) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good the disturbed surface complete all as specified and as directed .
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Taking down unserviceable existing LT Panel / Meter Box with 100 Amps MCCB of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Taking down existing DB SPN 8 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M&L for point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed multistranded copper conductor single core cable drawn through and including PVC Conduit concealed of suitable size medium grade ISI marked with all accessories such as bends, elbow,branded modular junction boxes /MS boxes made out of 1.6 mm thick MS sheet factory painted rectangular as required concealed in wall with top cover modular of required size, fixed with screws, for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed multistranded copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed, for the following :-
a) One light point controlled by one switch
b) One fan/ exhaust fan point controlled by one switch and regulator
c) One 3 pin socket, 5 Amps on the same board, with cables 1.5 sq. mm size
d) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size
e) One light point controlled by two 2-way switches, with cables 1.5 sqmm.
f) One call bell controlled by one push button with cables 1.5 sqmm
M&L for point wiring complete with FRLS 1100 Volts grade, two runs of 2.5 sqmm copper cable through PVC conduit concealed with one run of 2.5 sqmm PVC insulated and unsheathed multistranded copper conductor cable as earth continuity wire connected to common earth dolly complete all as specified and as directed.
S&F switch modular type single pole 6 Amps one way(ISI Marked) with one module cover all as specified and as directed.
S&F modular type switch two way (ISI Marked) with one module all as specified and as directed.
S&F switch socket combination 2 in 1, 3 pin, 6 Amp modular type(ISI marked) with three module all as specified and as directed.
S&F switch socket combination 5 in 1 pin 5 / 16A, modular type(ISI Marked) with three module all as specified and as directed.
S&F bell push modular type(ISI Marked) with one module all as specified and as directed.
S&F Ding dong Bell (ISI Marked), AC, 230 volts, single pole 50 HZ AC all as specified and as directed.
S&F ceiling rose three terminal,ISI Marked, 230 volt 50 HZ AC all as specified and as directed.
M & L for submain wiring with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC CONDUIT 25 mm dia in Ivory/Grey colour medium grade etc fixed on concealed including provision of 01 run of 6.0 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 6.0 sqm including 01 run of PVC conduit shall be measured as one length.
Supply and fix in repair of MCB DB, single pole and neutral with suitable Amps rated busbar double door 8 way 230 volt 50 HZ AC all as specified and as directed.
S&F in repair of MCB SP 06 to 32 Amp 230 volts, 50Hz,Breaking Capacity 10 KA complete all as specified and as directed.
M&L for RCCB Double pole, 30mA 25 Amps 230V 50Hz AC complete all as specified and as directed.
Supply, install, testing and commissioning of factory made LT panel CPRI appoved wall mounted made out of CRCA sheet of 2 mm thick indoor type double door compartmentalised construction totally enclosed weather, dust and vermin proof with front opening hinged door locking arrangement 415 volt 3 phase 4 wires AC 50 Hz having aluminium busbar for phases and the neutral insulated with PVC sleeves, suitable chamber for fixing single phase electric meter -9 Nos complete, and epoxy powder coat of spray paint over a coat of red oxide primer complete all as specified and directed.Panel shall be fitted semi concealed on wall. INCOMING (a) Including provsion of MCCB 415 volts 4 pole 25 KA breaking capcity thermal magnetic of 125 Amps - 01 Nos. (b) R -Y-B phase LED incating lamps - 03 Nos (c) 200 Amp TPN main aluminium busbar OUTGOING (a) Including MCB SP & N 32 Amps breaking capacity 10 KA 'C' Curve - 09 Nos (b) Space for mounting single phase energy meter - 09 Nos (c) Copper flexible wires of 6 Sqmm size for all feeders/meter connection.
S & F in repairs 1 Phase KWH Meter, electronic type 5-30 Amps tamper proof including PVC sealing and connecting cable on Meter panel in item No.18 above complete all as specified and as directed. Note:Old Electric meter shall be deposited in MES store.
Fixing only LED Tube light fitting 18/20 watt and should be connecting up with twin core twisted flexible copper cable including PVC square box, clamp and necessary fittings complete all as specified and as directed. Note: LED Tube light fittings shall be issued under Sch 'B' free for fixing.
Fixing only LED Tube light fitting 19/10 watt and should be connecting up with twin core twisted flexible copper cable including PVC square box, clamp and necessary fittings complete all as specified and as directed. Note: LED Tube light fittings shall be issued under Sch 'B' free for fixing.
S&F in repair of deluxe stepped type electronic fan regulator modular type with 2 module complete all as specified and as directed.
S&F in repair of lamp holder, PVC/polycarbonated type with back plate suitable for batten fitting including 9 W LED lamp -01 Nos complete all as specified and as directed.
M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified and as directed.
Supply and fix in repair Exhaust fan (Square type) 230V single phase plastic body, sweep size (mm) 250 connecting up including provision of necessary wall opening and connected cement works and cable from ceiling rose or connector to exhaust fan etc complete all as specified and as directed. Note: Old exhaust Fan shall be deposited in E/M store
Supply and Fix in repairs louvers of exhaust fan (aluminium) upto 300 mm sweep any make complete all as specified and as directed. Note: Repairs of louvers shall be at any storey quarter or building
Supply and Fix in repair Ceiling Fan motor with body complete suitable 1200 mm Sweep matching to blade of existing ceiling fan all as specified and as directed.
Supply and Fix in repair Fan Blade set of three suitable of any make and sweep up to 1200 mm sweep matching to existing ceiling fan all as specified and as directed.
M/S jvsr constructions
pk janardhanan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .