| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.4 LAdmitted-Finance | -32.10% | ₹16.4 L | L1 | Admitted-Finance |
| 2 | L2₹16.9 LAdmitted-Finance | -30.00% | ₹16.9 L | L2 | Admitted-Finance |
| 3 | L3₹17.4 LAdmitted-Finance | -27.79% | ₹17.4 L | L3 | Admitted-Finance |
| 4 | L4₹18.1 LAdmitted-Finance | -25.00% | ₹18.1 L | L4 | Admitted-Finance |
Tender Value
₹24.1 L
EMD Value
₹48,220
Closing Date
25 Feb 2026, 4:00 pmClosed
Er Gurjeet singh
XEN Paddar
Refer to BOQ
2026_PWDJK_302251_1
e-NIT No. 53 of 2025-26 Dated 04-02-2026
Open Tender
Civil Works
120 days
Paddar
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD Division Paddar
₹48,220
5 Mar 2026
4 Feb 2026
26 Feb 2026
4 Feb 2026
25 Feb 2026
4 Feb 2026
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil :
Hand packed stone filling including Cost of stone
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)20% plum
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc. complete 40mm thick with 20 mm nominal size stone aggregate.
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand
Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level
Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fastenersshall be paid for separately):Second class deodar wood
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second class Kail wood 35 mm thick
Providing and fixing panelling or panelling and glazing in panelled or panelledand glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to bemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. Second Class kail wood
Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws.Second class Kail wood 30mm thick
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mmfor doors, windows and clerestory windows with ISI marked M.S. pressed butthinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge : Second class Kail wood
Providing and fixing wooden moulded beading to door and window frames withiron screws, plugs and priming coat on unexposed surface etc. complete: 9.40.1 2nd class teak wood 9.40.1.1 50 x 12 mm
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platforms.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Columns, pillars, piers, abutments, posts and struts.
20mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 coarse sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface.
Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with nuts and screws etc. complete 9.98.1 300x16 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 9.99.4 150x10 mm
Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 9.99.3 200x10 mm
Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing aluminum handles ISI marked anodized (anodic coatingnot less than grade AC 10 as per IS: 1868) transparent or dyed to requiredcolour and shade with necessary screws etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete 11.52.2 Size of tile 600x600 mm
Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels 8.2.2 Granite of any colour or shade 8.2.2.2 (Area of slab over 0.5 sqm)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
Providing and fixing bright finished brass hard drawn hooks and eyes 14.35.3 200 mm
Dismantling wooden, trusses, purlins and rafters, GI sheet and ceiling, all wooden items i.e. lining, column/posts and beam etc. including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead as per direction of engineer in charge
Skilled labour
unskilled labour
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and below
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : Of area of 3 sqm. and below
Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:4:8 or leaner mix (i/c equivalent design mix)
Carriage of material by Mechanical Transport & Head Load including loading / unloading and stacking at site
Sand for an average distance of 02 km by MT & 100 mtr by Head Load
Stone aggregate below 40 mm nominal size lead upto 60 km by MT & 100 mtr by Head Load
Steel for an average distance of 100 mtr by Head Load
Cement for an average distance of 100 mtr by Head Load
Bricks for an average distance of 230km by MT & 100 mtr by Head Load
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3pin 5/6 A socket outlet
15/16amp switch
6 pin 15/16 socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following way single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way ( 4+18), (Double door) SPN Type
Supplying and fixing 5A to 32A rating,240/415 V. 10 KA."C" curve, miniature circuit breaker for inductive load of following poles in the existing MCB DB complete with Connections, testing and Commissioning etc. as required.
Single pole
single pole and Nuetral 63 Amp
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm
Supplying and Fixing of 16 sq. mm twin core aluminium cable all along the wall surface unarmoured.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
BOQ_980787.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid