Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance F 2 87 88 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹95.3 L
Closing Date
2 Mar 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Atul Bhardwaj
OFFICE OF THE EX. ENGINEER (ELECT.)-WZ OLD ZONAL BUILDING, Ist FLOOR, VISHAL ENCLAVE RAJOURI GARDEN, NEW DELHI-110027
Construction of Bharat Darshan Park at Panjabi Bagh ward 02-S in West Zone under Waste to Art.
2021_SDMC_71047_1
EE/Elect/WestZone/2020-21/21
Open Tender
Electrical Works
Works
60 days
West zone
Subhead Provision of CCTV Surveillance system, LED Screen and PA System
2 documents required · 2 mandatory
₹500
Yes
Commissioner SDMC
Exempted
17 Mar 2021
23 Feb 2021
3 Mar 2021
23 Feb 2021
2 Mar 2021
23 Feb 2021
150 days
Amount
S/I/T/C of 2MP varifocal lens Bullet IP Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:25 fps or better ** Lens: 2.8 to 12mm Varifocal lens Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
S/I/T/C of 2MP PTZ Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate:25 fps or better ** Lens: 30 X ZOOM Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
S/I/T/C of 32 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :160Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 2 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL
SITC of 6 TB surveillance HDD
SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
Supply Installation testing Commissioning of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
S/I/T/C of LED Monitor full HD complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 400 NITS min. Video I/P port a) Min. 02 Nos HDMI 1920x1080. b) Min 01 No VGA Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz Installation at site with connections and along with all accessories of 42 INCHES etc. complete as required with min. 3 year onsite warranty.
P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-55 weather proof pole box of inner dimension 300mm X 200mm X105 mm(NS) complete with suitable arrangment for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN channel with 2 nos. of MS clamps with SS back plate of suitalbe size with Danger monogram property printed on the cover etc as reqd.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD- 63 MM and ID 51 MM)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm.
Supply Installation testing and Commissioning of Pigtails 1 meter with Splicing and testing.
Supply Installation testing and Commissioning of optical media converter gigabit SC to SC type up to 10 km.
Supply Installation testing and Commissioning of LIU boxes complete with all accessories etc. as required of 12 ports
Supplying and laying of Optical Fiber Single Mode Cable (6-Fiber) on surface or in existing conduit etc complete i/c connections etc complete as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.Logo/Name of manufacturer shall be embosed on the pole, galvanization as per relevant IS.(c) 8.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick.
(c) 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm(L) x 600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -1160 mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1600 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts of size 20 mm dia,750mm long J type i/c 2 nos. ,template anchor plate of size 225mmx225mmx3mm and providing DWC HDPE pipe for cable entry & exit as required for 7 m and 8 mtr pole
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts of size 16 mm dia,600mm long,j type i/c 2 nos. ,template anchor plate of size 225mmx225mmx3mm and providing DWC HDPE pipe for cable entry & exit as required for 3 m and 5 mtr pole
Big Screen Supplying, Installation, Testing and Commissioning of IP65 (front) Out door LED video wall having aluminium diecast cabinet material complete with 6 mm pixel pitch having brightness of 5500 nits Viewing Angle (horizontal/vertical) 160°/ 140°, contrast 4000:1, Physical density 27777dot/m2, The display shall be compactable with various formats like M.S. office, PDF, PPT & Movies with suitable controller for operation on 230V, 50 HZ AC supply. the life span of video wall shall not be less then 1,00,000 hrs. and OSD shall be 16/32 bit OSD. Video wall should be operated through existing PC/Laptop/IP LAN Port . The board shall operate as per given format complete with computer compatibility etc complete as required.
Supplying and installation of All in One Desktop computer having features, Dispay Size - 21.5 inch, Core I5, 10th generation, FHD, RAM-4 GB, One TB SDD, Window-10 (Original), MS office, wireless Key board & mouse etc complete as required.
Design, fabrication, supplying, installation of structural Iron frame work of Angle Iron 50mm x 50mm x 6mm thick on top and M.S pipe of 12" dia on bottom with base plate 10 mm thick duly grouded with CC foundation of size 900 mm x 900mm x 1200 (deep) for installation / fixing of LED wall and for withstand the wind pressure upto 150KMPH at height 18 ft (aprrox) from ground i/c cutting, hosting welding, grinding and installation/fixing by CC or dash fastner as the case may be and applying one coat of steel primer and two or more coat of synthetic enameled paint etc complete as per direction of Engineer-in-charge as reqd.
PA System
SITC all weather proof loudspeaker for speakers for otdoor ground , having sound LF, HF - 1" exit Max SPL not less than 128db /1m (peak), with continuous RMS power of 45 - 55 Watt RMS with programme power of 90 – 110 Watt RMS & peak power of 180 - 220 Watt RMS with minimum sentivity of 97db, Nominal Impedance : 8 ohms, nominal dispersion : 90 x 60, in birch plywood paint finish with wall mount bracket , suitable size MS frame box cover for protection etc. complete as required.
Supply installation testing & commissioning of Professional total 16 channel audio mixer with 16 mic inputs; 2 line inputs 2 stereo inputs; with inbuilt effects and equalizer, graphic EQ etc. complete as reqd.
Supply installation testing & commissioning of Dual Channel Power Class H/ D amplifier for Subwoofer & Main Speakers & outdoor speakers 2000 watt , Damping factor > 450, as required.
Supply Installation testing & Commissioning of 18" Gooseneck cardioid Microphone, polar pattern cardioid, Frequency Range 70-18000 Hz, Sensitivity18mV/Pa, Impedance >2000 ohms. Complete with desk stand with switch etc. as reqd.
Supply, laying & Fixing of Speaker Lines: 2-Core, 2.5 sq mm High definition Speaker Cable, PVC insulated in PVC jacket laid in existing conduits as reqd.
Annual Maintenace
comprehensive maintainance of whole system for another four years after completion of 1 year warranty or defect liability period.
2nd year @5% Part-A (S.No-1 to 16)+Part-B (S.No 1 to 2)+Part C(All Items)
3rd year @6% Part-A (S.No-1 to 16)+Part-B (S.No 1 to 2)+Part C(All Items)
4th year @7% Part-A (S.No-1 to 16)+Part-B (S.No 1 to 2)+Part C(All Items)
5th year @8 Part-A (S.No-1 to 16)+Part-B (S.No 1 to 2)+Part C(All Items)
MASTER ELECTRIC STORE
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .