Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L1 | Accepted-AOC L1OK | |
| 2 | L2₹8.5 L+₹2.3 L (36.0%)Rejected-AOC | L2 | Rejected-AOC OK |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
HQ CWE (AF) BHISIANA
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY ALONG WITH CONNECTED ITEMS AT AF STATION ABOHAR UNDER GE AF BHISIANA
2022_MES_532304_1
CWE(BHI)/BHI-20/2022-23
Open Tender
Civil Works
Item Rate
180 days
AF Bhisiana
AS PER COVER 1
6 documents required · 6 mandatory
₹500
Yes
GE AF Bhisiana
₹20,000
Yes
26 Aug 2022
20 Jun 2022
29 Jul 2022
20 Jun 2022
27 Jul 2022
4 Jul 2022
20 Jun 2022 - 27 Jun 2022
Amount
S&F in replacement of factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps suitable foundation, complete all as specified and as directed.
S&F in replacement of Switch air break gang operated tripple pole mechanically operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers "Navtal" lock consisting of mild steel channel, HT post top insulator copper alloy high pressure asembly with drop out expulsion fuses for phases, operating rod of 25mm dia medium grade G.I pipe complete confirming to IS-1018 of 1972 with continous current rating 200Amps, 11000 volts grade, complete all as specified and as directed.
S&F in replacement of underground cable XLPE insulated screened armoured and PVC bedded HT 11000 volts grade (heavy duty) with aluminium conductor 3 core, 150 Sqmm, laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Material and labour for disconnection and dismantling of existing transformer of capacity up to 100-200 KVA for repair work and refixing and reconnecting the same complete all as directed as under:- (i) Replacement of gasket, nuts bolts and washer. (ii) Replacement of neoprene rubber washer. (iii) Replacement of silica gel. (iv) Replacement of copper lugs including ACSR jumpers from HT OH line to primary side of TF. (v) Cleaning of bush insulator LT/HT side. (vi) Tightening of connection of earthing lead to neutral & body. (vii) Replacement of MS cable box cover as per requirement at site. (viii) Replacement of HT & LT bush. (ix) Replacement of HT & LT bush copper Rod.
Supply & Fill in replacement for filling of new transformer oil up to minimum level, break down value of transformer oil should not be less than 50 KV, complete all as specified and as directed.
Material & Labour for filtration/dehydration of transformer oil up to break down valve reaching upto 50 KV dilectric strength, complete all as specified and as directed. NOTE : Contractor will arrange filtration plant machine at site of transformer.Dehydration work will be carried out in working condition and electric supply will be taken from same transformer.
Material and labour for preparation of old steel surfaces and applying one coat of synthetic enamel paint to steel surface Transformer /voltage stabilizer/isolation Transformer after disconnecting the electrical connections and reconnecting LT cables after painting including writing of MES No. complete all as specified and as directed. Note: Spray paint to be used for painting surface of appliance after removing the old paint.
M&L for replacement of oil temperature Gauge including nuts, bolts and gasket including taking down complete upto 200 KVA, complete all as specified and as directed.
Opening/stripping off voltage stablizer of capacity 50 KVA to 150 KVA including draining off oil, washing & cleaning duct, dirt & sludge deposit etc. from all parts. Removing damaged/deffective parts requiring replacement,making internal connection servicing of bushings and reassembling the voltage stablizer after repair and replacement work including new cork gasket, packing nuts, bolts, washer, etc. complete all as specified and as directed. Note : Servicing will be done by reputated company rep at site only.
M&L for calibration/overhauling/servicing of relay any type voltage,current(e.g. Earth fault relay/Over current relay,etc) for 11 KV HT panel.The setting of these relays should be as per the PSPCL norms so that primary sub station individual breaker/feeder should be tripped and fault is not travelled back to MRS and subsequently to PSPCL.The calibration of relay is to be done by Add SE Protection Division (PSPCL ) deptartmnt and it is to be submitted to the AGE E/M sub divn .All the calibration should be done in the presence of Engineer-in-charge or JE E/M Note :- Any relay and HRC Fuse required during the work which should be measured in quoted rate.
Disconnecting the existing servicing electric supply from HT 11KV VCB system of any make type taking out switch gear from SF-6 circuit breaker (any type)/VCB/,cleaning from inside and out side by using CRC-26 spray or any other cleaning agents which can improve the electrical conductivity or properties,greasing whereever required overhuling of switchgear ,checking the fixed/moving contacts of all the 3 phases adjusting electrical/electronic/mechanical components all as per mfg instruction manual and standard practice & reassembling the same after necessary servicing repair including testing and commissioning in its original position & necessary connection etc all as specified and directed.This work is to be get done from company authorised sales and supplier dealers and complete all as specified and as directed.
S&F in replacement of earthing complete with galvanised steel steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than 1.5 mtrs below nominal ground level connected to galvanised strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No 3 of SSR Part I connected to earthing test point and testing on completion. all as specified and as directed. Note:- the cast of excavation and earth work PCC pit and PCC cover with handle, funnel & watering pipe, wiremesh,charcoal dust and common salt and earth strip up to 7.5 mtrs long shall be deemed included in the unit rate for earthing complete all as specified and as directed.
All as per item No. 13 above but size of earthing strip 32x6 mm
S&F in replecement cable route indicator made out cast iron and embedded HT/LT cable and size of the cable on the plate of size 80mm dia 5 mm thick and grouting legs of suitable size including grouting in PCC foundation of suitable size, complete all as specified and as directed.
S&F in replecement MCCB 350 Amp 4 Pole of rupturing capacity 36 KA, complete all as specified and directed.
S&F in replecement MCCB 200 Amp 4 Pole of rupturing capacity 36 KA, complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 Pole of rupturing capacity 25 KA complete all as specified and directed.
S&F in replacement MCCB 125 Amp 3 Pole of rupturing capacity 16 KA, complete all as specified and directed.
S&F in replacement MCCB 100 Amp 3 Pole of rupturing capacity 16 KA, complete all as specified and directed.
S&F in replacement MCCB 63 Amp 4 Pole of rupturing capacity 16 KA, complete all as specified and directed.
S&F in replacement Time switches with battery backup 3P module, 24 hours programm, programable every 30 min, backup of 100 hrs current capacity 16 Amps complete all as specified and directed.
S&F in replacement of 170 watts LED Flood light for highly efficient LED Flood light with lens made of pressure die cast aliminium housing, extruded aluminium heat sinks & enclosed with toughened glass IP-66 fitted on the wall/ roof top/pole/ High Mast tower etc. with the help of nuts,bolts, clamps PCC work including connection with 2.5 Sqmm 3 core copper wire, complete all as specified and as directed. Note :- All T&P i.e ladder, tools, safety gloves etc will be provided by the contractor without any extra cost.
All as per item 23 above but capacity 100 watt
Supply & Fixing in replacement of Driver for flood light 170/100 Watts, complete all as specified and as directed.
All as per item No 25 above but capacity 35/60 watt
S&F in replacement of Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
All as above item No 27 but capacity 60 watt
S&F in replacement of S&F in repairs PVC junction box of size 25x20x15cm with hinged door including locking arrangement, 04 Nos aluminium bus bar complete with necessary clamp, nut, bolt including single pole MCB of 6 Amp, complete all as specified and directed by Engr in charge.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 185 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 95 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 70 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 50 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 35 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 25 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 16 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
S&F in replacement of LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 10 Sqmm 2 core laid in ducts/through pipes, in floor, on poles, in trenches, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and as directed.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches, complete all as specified and as directed.
Supplying & laying old size sub calss 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable, adjacent/abutting each other, complete all as specified and as directed.
M&L for Prepration of old Steel Surfaces and applying two coat of synthetic enamel white paint to Steel tubular Pole height of pole 9/11 mtr from ground level alternative in and 1 mtr height from ground level Yellow and black strips of 30 CM height each including numbering of Pole No with black paint, complete all as specified and as directed.
M&L for Trimming/cutting of trees branches.bushes obstructing the HT/LT poles / street light making clear distance of 3 RM from the pole all around of poles/light , complete all as specified and as directed.
M & L for making bore under road width under PCC foundation or road for laying of cable putting GI pipe for protection of cables, complete all as specified and as directed.
Supplying & fixing in replacement GI pipe light grade 50 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as requited, complete all as specified and as directed.
S&F in replacement of GI tubing light grade of 100 mm dia for cable protection on pole/wall/floor or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, complete all as specified and as directed.
Material and Labour for painting of LT Panels including cleaning of exposed surface with brush and emry paper including two coat of painting with smoke grey paint, including cleaning of all terminals with CRC Sprey and provides locking arrngement, any size of LT Panel, complete all as specified and as directed.
S&F in replacement of Synthetic Insulating Mat for Electrical Instrument of size 2.5mx1mx12mm, complete all as specified and directed.
S&F in replacement of LT cable end termination joint kit size 6 sqmm to 16 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable end termination joint kit size 25 sqmm to 50 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable end joint kit size 70 sqmm to 95 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable end joint kit size 120 sqmm to 185 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable straight through joint kit size 6 sqmm to 16 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable straight through joint kit size 25 sqmm to 50 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable straight through kit size 70 sqmm to 95 Sqmm, complete all as specified and as directed.
S&F in replacement of LT cable straight through kit size 120 sqmm to 185 Sqmm, complete all as specified and as directed.
S&F in replacement of Cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 50 sqmm to 95 sqmm
S&F in replacement of Cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185 sqmm
S&F in replacement of Cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185 sqmm
S&F in replacement of Cableend jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
S&F in replacement of Cable end jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm.
M&L for point wiring (concealed) on wall complete with FR PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 2.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic heavy grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes,modular switch plates and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-Charge.
S & F socket modular type 16 Amps, 3 pin combine, 2 module,240 volts all as specified and as directed by EIC. Make : Legrand Cat No. 675555 or equivalent in Leader, Anchor, Crabtree.
S & F switch modular type 16 Amps, 1 module,240 volts all as specified and as directed by EIC. Make : Legrand Cat No. 675511 equivalent in Acchor roma, Crabtree.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .