Loading…
Loading…
Tender Value
₹5.1 Cr
EMD Value
₹10.3 L
Closing Date
4 Aug 2026, 11:00 amClosed
Provision of Digital Axle Counter in parallel with overlap Track circuit at IB over Khurda Road Division.
ST-OT-AXLECOUNTER-KUR-576~ECOR
ST-OT-AXLECOUNTER-KUR-576
Open
Works - General
12 Months
Khordha, Odisha
₹0
₹10.3 L
4 Aug 2026
13 Jul 2026
21 Jul 2026
A-EXECUTION OF SIGNALLING WORKS: RATES ARE INCLUSIVE OF:1.All
B-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All
C-SUPPLY & EXECUTION OF DRAWING WORK : RATES ARE INCLUSIVE
4.Transportation of released materials from one site to another site or store of concerned SSES/(In-
charge) or as advised by Sr.DSTE/KUR.
Item- 1 EXECUTION OF SIGNALLING WORKS
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, Installation and Commissioning of Set 32.00 695020.00 22240640.00
Single Section Digital Axle Counter (SSDAC)
Phase Reversal type as per RDSO Specification
No. RDSO/SPN/177/2012 (Version-3) and latest
if any along with Installation accessories as
given below. (i) Single Section Digital Axle
Counter Phase Reversal type as per RDSO
Specification No. RDSO/SPN/177/ 2012
(Version- 3) and latest if any. Each Set consists
of following: - a) High frequency TX Coil and
RX Coil with Cables (Each Set consists of Web
Mounting type TX Coil 2 Nos., RX Coil 2 Nos.
along with 10 mtrs. Cable) = 2 Sets. One Set
will be submitted with SSDAC during
installation and one Set will be kept as Spare
with the Consignee. b) Track Side Digital Axle
Counter unit 2 nos. c) VR Box 2 Nos. Each duly
wired with 2 nos. of 24V, 6F/6B, 1000ohm Q
type relays. d) Clamp with deflector plates and
hardware etc. 4 nos. e) Reset Box 2 nos. f) All
other Equipment/Subsystem/literature as
available in Standard Set as per RDSO
Specification. (ii) Mushroom/Location Box
suitable for housing Track side equipment = 2
nos. Inspection by RDSO.
2 2 Excavation of trenches of 1.0 Meter depth and Kilometre 18.00 88821.00 1598778.00
width 0.3 Meter detailed below including
clearing of roots and trees etc. for all types of
soil. This work also includes covering of cables
laid in trench and backfilling, ramming,
consolidation of soil as well as disposal of extra
soil after cable is laid as specified in
Guidelines on Signalling Cable laying given by
RDSO and any latest circular issued by
CSTE/ECoR/BBS. Note: Before refilling of the
trenches, the cable laid are to be tested and
recorded for its insulation value and after
satisfaction of site Engineer the refilling
process should start and after monsoon the
route is to be attended for backfilling the rain
cuts, wash out of soils where ever found.
3 3 Supply & Erection of Polyolefin Cable Channel Numbers 6000.00 2120.02 12720120.00
of size width (Int/Ext) 240/340mm, Length
approx. 1 Meter, weight per mtr. Should be not
less than 8 Kg (Top & bottom). Material-
Polyolefin-Engineering plastic with fire
protection class K-1 in accordance with DIN
53438 part-II, breaking load Minimum >=12
Kilo Newton or latest at room temperature for
laying signalling/Telecom/Power Cables,
Channel attachable to each other with male
female swallow tail connectors and having
suitable detachable cove. Technical
specification and testing Parameter /Procedure
as per RDSO- Ref No. STC/Cable-laying
practices Vol-IV dated 09.05.2018. Inspection
of polyolefin cable channel by RITES.
KHURDA ROAD DIVISION-S AND T/ECOR
4 4 Excavation of trenches in all kinds of soils Metre 500.00 335.00 167500.00
including soft rocky area and clearing of track
etc. to a depth of 1.0 M and width of 0.3 M for
track crossing /pucca road/level crossing
gate/platform/station circulating area or any
other place as advised by site Engineer
including transportation and laying of
DWC/RCC/Split RCC/G.I. pipes with or without
coupler. This includes repairing of track/pucca
road/level crossing gate/ platform/station
circulating area surface to original position by
ramming and concreting wherever required
soon after the work is over. DWC/RCC/GI pipes
shall be supplied by the Railway. DWC pipes
wherever required shall be supplied in 6 Mtr.
length and shall be cut to size as per
requirement. All other materials including
cement are to be supplied by the contractor.
5 5 Excavation of trenches including clearing of Metre 1000.00 255.00 255000.00
roots of trees etc., in rocky area up to a depth
to be indicated by Railway Engineer at site as
per the site condition [Minimum 0.6 meter]
and width 0.3 Mts. at the bottom. This includes
concreting & plastering as per the instructions
of site Engineer and complete back filling by
digging earth from a lead of 30 Mtr. In case
0.8-meter depth or higher is achieved no
concreting is required, otherwise concreting
up to 100 mm thickness should be done. All
materials required for the above works shall
be supplied by the Contractor.
6 6 Cutting of masonary floor/walls at station Numbers 20.00 6108.00 122160.00
building/ signal goomty/ Gate lodge at a depth
of 0.5 mtr. to 1.0 mtr at places to be indicated
by site Engineer for entering of cables inside
the building. Only G.I pipes supplied by
Railway and all materials as clamps, bolts &
nuts as instructed by site Engineer supplied by
tenderer. This includes repairing of masonary
floors/walls after the cables are taken inside.
Cement, Sand required for the work shall be
supplied by the tenderer and also
transportation of G.I Pipe from Store by the
7 7 Transportation and fixing of perforated G.I. Metre 300.00 2653.00 795900.00
Pipes on bridges, culverts, drains or in
trenches or any other place as per instruction
of site Engineer with clamps at 1.5 mts.
interval on steel girder bridges or at places
advised by site Engineer. This includes
supplying of G.I. Pipes, 80/100/150 mm dia.
Specn. No. IS:1239/2004, or latest medium
gauge with threaded collars (Make -TATA
/JINDAL) by tenderer. This also includes 100
mm thick concreting on GI pipes as required
and instructed by site Engineer and all other
materials required for the work shall be
supplied by the tenderer. Note: The G.I. pipe
shall be perforated by drilling 7 mm dia holes
length wise in zig-zag manner staggered at a
distance of 300 mm. G.I. Pipes before and
after perforation and bridge fixtures supplied
by the tenderer will be inspected by
representative of Railway before use. The
bridge fixtures will be supplied by tenderer for
fixing of GI pipes on girder bridges only. (1) GI
pipes of 100 mm Dia
KHURDA ROAD DIVISION-S AND T/ECOR
8 8 Laying of Signalling/4 Quad/ 6 Quad/ Power Kilometre 70.00 24389.00 1707230.00
Cable/Telecom cables/ Jelly filled cables of all
sizes in excavated trench, through
GI/RCC/DWC pipes etc. wherever required.
This includes transportation of cables from the
stores to work site and transportation of empty
cable drums with left over cables from site to
the stores at. The length of cable laid includes
the length of cable coil for termination
purpose. NOTE: The cables are to be carefully
handled during loading, un-loading and
transportation to work site. Any damage found
in the cable after final testing, in view of
mishandling of cables, shall be made good by
the Tenderer. Cable should be maggered
before and after laying and recorded in a
register and submitted to the site Engineer.
9 9 Transportation, excavation of pit, casting of Numbers 40.00 19438.00 777520.00
foundation, plastering and erection of Steel
Apparatus case (full size) with fixing of E-Type
lock, wiring, cable entry, termination
clamping, filling cable pit with sand, painting
and lettering etc., as per Drg.No.
S&T/CON/SK/16. This includes earth work
and/or masonry work required for securing the
apparatus case as per site condition. Railway
will supply apparatus case with 'E' type lock
only from Railway stores at. Tenderer will
supply all wiring materials, PBT Terminals,
fuses, fuse blocks, bus bars, hylum sheet ISI
mark [6mm thickness], wood plank board of
good quality [minimum 3/4" thick, Cement and
transport all the materials to site of work at his
own cost. The wiring materials such as wire
coils, PBT terminals, fuses, fuse block, etc.
should be used from RDSO approved sources.
1) Modification of inside arrangement of
Apparatus cases if required for fixing of
relays/transformers etc. shall be done by the
contractor. Extra shelf, if any, shall be
deposited to the Railway stores by the
contractor. 2) All cables shall be terminated by
providing copper eyelet of suitable size. Note:-
(i) If location box foundation is available at site
20% of the cost is to be deducted. (ii) 40%
payment shall be released after erection of
location boxes.
10 10 Supply, Transportation and Installation of Numbers 40.00 12306.00 492240.00
earth electrode (make TATA or Jindal as per
Rly. practice) including MS flat for signalling
equipments on lever frame, apparatus cases,
signal, relay racks, cable termination rcak,
block instrument etc. (supply & installation of
earth electrode as per drawing no.
RE/S&T/DRG/Tender/SK/398/94 for apparatus
cases, signal post & other equipments as per
instruction on earthing of S&T equipment.
Laying of earth lead mild steel flat of size
35mmx6mm and fixing of lead MS flat (make
TATA/Jindal or Similar) to earth electrode and
lever frame, signal post & apparatus cases as
per Drg. No. CORE/S&T/ALD/SK/591/2008,
592/2008 and 593/2008 respectively and
instructions on earthing at S&T equipment and
providing cement enclosure for earth
electrode as per drawing no.
RE/S&T/Sig./Tender/SK/13/85 Alt. A) NOTE:
This includes testing of earth value and
indicating the same on the Earth enclosure by
paint. Inspection by representative of
KHURDA ROAD DIVISION-S AND T/ECOR
11 11 Alteration of wiring in existing apparatus cases Numbers 40.00 3583.00 143320.00
full/half. This includes supply of all materials in
connection with alteration in wiring. All the
materials shall be supplied by the contractor
at his own cost. This includes entry of cables,
sand filling and masonry work involved.
Lettering and painting to be done by the
contractor at his own cost. Railway shall
supply only relays and relay bases.
12 12 Alteration of wiring in existing Relay rack/ CT Numbers 40.00 28281.00 1131240.00
rack/composite relay rack. This includes supply
of all types of wires, eyelets, nuts & bolts,
bunching material, ferrules, ARA terminals,
fuses & fuse blockes by the contractor at his
own cost. Lettering & painting to be done by
the contractor at his own cost. Wire (RDSO
Approved Sources) to be inspected by the
representative of Railway before use.
13 13 Fixing of relay bases and wiring, bunching, Per Relay 200.00 783.00 156600.00
fixing of relays, wiring in Old relay
racks/location box and also carrying out any
alteration in existing relay rack duly wiring
and connecting New to old and Old to old
relays by standard wires (RDSO Approved
Sources) as per Circuit diagram. Fuses of
bases, condensers, ND fuses, LED indicator &
its wiring for relay rack. All materials required
for this work will be supplied by the contractor
from RDSO Approved Sources. Relays with
accessories will be supplied by the Railway.
Schedule B-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All taxes., 2.Supply of
sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of materials to site.,
4.Transportation of released materials from one site to another site or store of concerned SSES(In
charge) or as advised by Sr.DSTE/KUR
Item- 2 SUPPLY OF SIGNALLING MATERIALS.
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply of Single Section Digital Axle Counter Set 6.00 588820.00 3532920.00
(SSDAC) Phase Reversal type as per RDSO
Specification No. RDSO/SPN/177/2012
(Version-3) and latest if any along with
Installation accessories as given below. (i)
Single Section Digital Axle Counter Phase
Reversal type as per RDSO Specification No.
RDSO/SPN/177/ 2012 (Version- 3) and latest if
any. Each Set consists of following: - a) High
frequency TX Coil and RX Coil with Cables
(Each Set consists of Web Mounting type TX
Coil 2 Nos., RX Coil 2 Nos. along with 10 mtrs.
Cable) = 2 Sets. One Set will be submitted
with SSDAC during installation and one Set will
be kept as Spare with the Consignee. b) Track
Side Digital Axle Counter unit 2 nos. c) VR Box
2 Nos. Each duly wired with 2 nos. of 24V,
6F/6B, 1000 ohm Q type relays. d) Clamp with
deflector plates and hardware etc. 4 nos. e)
Reset Box 2 nos. f) All other
Equipment/Subsystem/literature as available
in Standard Set as per RDSO Specification. (ii)
Mushroom/Location Box suitable for housing
Track side equipment = 2 nos. Inspection by
RDSO. (NOTE: The material is to be used as
spare, so there is no need of installation &
commissioning.)
KHURDA ROAD DIVISION-S AND T/ECOR
2 2 Supply of Relay AC Immune, plug-in type, Numbers 200.00 6428.00 1285600.00
style 'QNA1', Neutral line, 24V DC 8F/8B
contacts, Front and back contacts metal to
carbon, complete with plug board, retaining
clip and connectors conforming to BRS : 931A,
IRS : S - 60, IRS : S - 34, IRS : S-23 (As
applicable). Interlocking code: ABDGH.
Inspection by RDSO.
3 3 Gallant Power AC to DC converter Input-230V Numbers 64.00 40120.00 2567680.00
AC, Output-(-) 48V DC/10A(500Watt) with built
in diode, digital volt/Amp meter and all
required protection circuits. (Model No-PS-
4810RV2). Inspection by RITES.
4 4 Supply of double walled corrugated pipe 6 mtr Numbers 90.00 4117.00 370530.00
in length, 120 mm outer dia and 103 mm inner
dia, with one suitable coupler conforming to
RDSO Specification No. RDSO/SPN/204/2011
Version 1.1 Amdt 1 or latest for underground
cable protection. Colour-Orange. Note: If
required, the DWC pipe shall be supplied split
in two halves. Inspection by Representative of
5 5 Supply of Steel Apparatus case 'large Size' as Numbers 13.00 42507.00 552591.00
per Drg. No - CON/SK/1/1/86 and Spec.No.
IRS:S-10/78 (adv) with latest amnd. with "E"
type lock and key of ward No-32 with handle.
Inspection by RITES.
Schedule C-SUPPLY & EXECUTION OF DRAWING WORK : RATES ARE INCLUSIVE OF:1.All taxes.,
2.Supply of sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of
Schedule materials to site., 4.Transportation of released materials from one site to another site or store of
concerned SSES/(In-charge) or as advised by Sr.DSTE/KUR. (Item Directory - Not Applicable) (Item
Directory - Not Applicable) (Item Directory - Not Applicable)
Item- 3 SUPPLY & EXECUTION OF DRAWING WORK
S No. Item Description of Item Unit Qty Rate Amount
1 1 Compilation, preparation, correction, updating, Per Page 400.00 25.00 10000.00
printing and supply of Final station working
rules with contractor's stationery, tools, plants
and materials. Note: Final SWR to be
submitted in 2 sets for each station. NOTE: Per
page should be treated as Page.
2 2 Alteration of Existing Location Box Drawings Sheet 100.00 451.00 45100.00
(Including Contact Analysis, Fuse Particulars
etc) and submission of Three paper copies for
approval. NOTE: Sheet should be treated as
3 3 Alteration of Existing Goomty Drawings Sheet 500.00 901.00 450500.00
(Including Relay Disposition Chart, Contact
Analysis, Fuse Particulars, CT Rack Particulars
and Floor Plan etc) and submission of Three
paper copies for approval. NOTE: Sheet should
be treated as per sheet.
4 4 Supply of Original Tracing in A-3 Size. NOTE: - Sheet 600.00 71.00 42600.00
For Drawings larger than A-3 Size, payment
shall be made in multiples of A-3 Size. NOTE:
Sheet should be treated as per sheet.
5 5 Supply of Amonia Prints in A-3 Size. NOTE: - Sheet 1800.00 19.00 34200.00
For Drawings larger than A-3 Size, payment
shall be made in multiples of A-3 Size. NOTE:
Sheet should be treated as per sheet.
6 6 Alteration of Existing SWRD & submission of Station 16.00 2596.00 41536.00
Three paper copies for approval For a Four-
Line Station. NOTE: Station should be treated
as per station.
KHURDA ROAD DIVISION-S AND T/ECOR
7 7 Design of Location Box Drawings (Including Station 16.00 1763.00 28208.00
Contact Analysis, Fuse Particulars etc) and
submission of Three paper copies for approval
For a Four-Line Station. NOTE: Station should
be treated as per station.
8 8 Supply of Original Tracing of Location Box Station 16.00 2644.00 42304.00
Drawings (Including Contact Analysis, Fuse
Particulars etc) after incorporating all the
corrections. For a Four-Line Station. NOTE:
Station should be treated as per station.
9 9 Supply of Eight sets of Amonia Print of Station 16.00 2821.00 45136.00
Approved Completion Location Box Drawings
(Including Contact Analysis, Fuse Particulars
etc). For a Four-Line Station. NOTE: Station
should be treated as per station.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022..pdf
ATTACHMENT
LISTOFANNEXURES..pdf
ATTACHMENT
SPECIALCONDITIONOFCONTRACT.pdf
ATTACHMENT
TENDERFORMSSECONDSHEET.pdf
ATTACHMENT
TENDERFORMSFIRSTSHEET.pdf
ATTACHMENT
TENDERFORMSTHIRDSHEET_1.pdf
ATTACHMENT
SCOPEOFWORK.pdf
ATTACHMENT
IBHLIST.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .