Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹29.7 L+₹19,468 (0.66%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹31.5 L+₹2.0 L (6.71%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹32.9 L+₹3.4 L (11.5%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Rejected being not lowest bidder | |
| 5 | L5₹34.9 L+₹5.4 L (18.4%)Rejected-Finance B 17 SHRIRAM INDUSTRIAL ESTATE G D AMBEKAR ROAD WADALA MUMBAI CITY MAHARASHTRA 400031 | MUMBAI | MAHARASHTRA | 400031 | L5 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR/MAINTENANCE TO LT POLE, ACSR OVERHEAD LINES AND MAINT OF SUB STN AT VARIOUS LOCATION UNDER E/M II IN GE (CENTRAL) KIRKEE
2022_MES_530531_1
CWE/KKE/TOKEN-09 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹98,000
Yes
22 Jul 2022
13 Jun 2022
6 Jul 2022
13 Jun 2022
4 Jul 2022
27 Jun 2022
14 Jun 2022 - 20 Jun 2022
120 days
Amount
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard / dense soil complete all as specified and directed by Engr-in-Charge .
Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in hard / dense soil complete all as specified and directed by Engr-in-Charge
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge
M&L for sand/fine dust cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
S & L precast unrainforced concrete LT cable cover, class LV, type flat , size 250mm x 150mm x 40mm complete for protection of underground cable complete all as specified and directed by Engr-in-Charge
Surface Excavation n. exc. 30 cm deep and avaraging 15cm deep and getting out any type of soil complete all as specified and directed by Engr-in-Charge
M&L for providing hardcore of gauge n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge
M&L for coloured machine pressed precast concrete interlocking paver block glossy finish (Two colour combination ) any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade with grey cement and pigment laid over sand cuhsion complete all as specified and directed by Engr-in-Charge
Supply and errect in true vertical position LT electric pole, Octogonal Pole, hot deep galvanised, with base plate of 220x220x12 mm thick, 07 Mtrs Long, top dia 70mm, bottom dia- 135mm, thickness of sheet- 3 mm, including Single arm GI bracket, inbuilt cable junction box with door, connection plate, MCB 6A, duly connecting existing LT UG cable, cable lugs, work included necessary earth work and RCC foundation as per manifacturers recommendation complete all as specified and directed by Engr-in-Charge Note: Earth work, PCC foundation as per manifacturer recommendation included in the unit rate.
Supply and errect in true vertical position LT electric pole, Octogonal Pole, hot deep galvanised, with base plate of 220x220x12 mm thick, 08 Mtrs Long, top dia 70mm, bottom dia- 135mm, thickness of sheet- 3 mm including Single arm GI bracket, inbuilt cable junction box with door, connection plate, MCB 6A, duly connecting existing LT UG cable, cable lugs, work included necessary earth work and PCC foundation as per manifacturers recommendation complete all as specified and as directed. Note: Earth work, PCC foundation as per manifacturer recommendation included in the unit rate.
Supply and errect in true vertical position steel tubular swaged poles in replacement complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410 SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete all as specified and directed by Engr-in-Charge Note: Excavation and earth work ,PCC in foundation /plinth block/coping shall be measured and paid separately
M&L for dismantling electric pole any type any size and removing from site complete all as specified and directed by Engr-in-Charge
M&L for disconnecting LT XLPE cable of any size from LT Panel or any location as directed for finding fault and M&L for defect rectification underground cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. complete all as specified and directed by Engr-in-Charge Note: (i) The fault locating equipments will be brought to site within the 12 hours of instruction from Engr-in-Charge. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered from the dues to the contractor. (iii) Rates included necessary earth work for opening cable for ready to jointing.
Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 25-50 sqmm , 3.5/4 core , complete all as specified and directed by Engr-in-Charge
All as per item Ser No 15.00 above but cable of size 70-120 Sqmm, 3.5 core.
All as per item Ser No 15.00 above but cable of size 150-185 Sqmm, 3.5 core.
All as per item Ser No 15.00 above but cable of size 240-300 Sqmm, 3.5 core
M&L for repair/maint of any size any capacity LT panel board, outdoor/indoor type, duly cleaning complete panel internally and externally, carrying out necessary repair work, replacement of unserviceable MCCB, MCB, meters, indicators complete all as specified and directed by Engr-in-Charge Note: (i) Quoted rates includes minor items like cleaning material, insulators, sleeves, gasket, welding work, cable lugs, insulation tape etc and excluding MCCB, MCB, meters, indicators. (ii) Quoted rates includes necessary earth work for disconnecting LT cable. (iii) Contractor should report to MES Rep for necessary shutdown for the respective feeder and should insure safety to avoid any untowards incident. All T&P and safety eqpts should be provided to worker at no any extra cost.
Supply only following items incorporate in Item No 19.00 above as replacment of old unserviceable items:- Note: fixing charges included in the item No 19.00.
Supply only MCCB of 4 pole 63 Amps 415 Volts with breking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 100 Amps 415 Volts with breking capacity 25 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 125 Amps 415 Volts with breking capacity 25 KA complete with thermal and magnetic release all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 160 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 200 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 250 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 320 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release complete all as specified and directed by Engr-in-charge.
Supply only MCCB of 4 pole 630 Amps adjustable type, 415 Volts, with breking capacity 36 KA with thermal and magnetic release all as specified and directed by Engr-in-charge.
Supply only Voltmeter, digital type, as per existing
Supply only Ameter, digital type, as per existing
Supply only PVC Insulated, Single core, copper conductor cable 4 Sqmm size
Supply only PVC Insulated, Single core, copper conductor cable 6 Sqmm size
Supply only PVC Insulated, Single core, copper conductor cable 10 Sqmm size
Supply, installation, commissioning and testing of outdoor type LT Box, having 4 Nos Aluminium bus bar of 400 Amps capacity suitable for 3 phase 4 wire, 415 volts AC supply, duly powder coated painting and canopy complete all as specified and directed by Engr-in-Charge Note: (i) Size of the box not less than 600x600x400 mm cubicabl type. (ii) The LT Box made out of 3.00mm thick CRCA mild steel sheet , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top (iii) Cost for suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. included in the unit rate.
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections etc complete all as specified and directed by Engr-in-Charge
Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of 10 sqmm 2 core , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed by Engr-in-Charge for the following items:-
All as per item No 23 above but for 10 Sqmm 4 core cable
All as per item No 23 above but for 70 Sqmm 3.5 core cable
All as per item No 23 above but for 95 Sqmm 3.5 core cable
All as per item No 23 above but for 120 Sqmm 3.5 core cable
All as per item No 23 above but for 150 Sqmm 3.5 core cable
All as per item No 23 above but for 300 Sqmm 3.5 core cable
All as per item No 23 above but for 400 Sqmm 3.5 core cable
Note for Item No 23.01 to 23.08: (i) During earth work for laying of cable, any damage to the existing services will be made serviceable without any extra cost within 24 hrs. (ii) Credit of Sch for cable has not been considered for complete qty because conversion of ACSR will be done at some places and credit shold be ACSR. (iii) contracor should visit the site before quoting the rate for understaniding the scope of work.
S&F for 100 mm bore tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed by Engr-in-Charge for the following items:-
All as per item No 24 above but for 80 mm bore
All as per item No 24 above but for 50 mm bore
M&L for cutting through existing bituminous road /PCC/floor/ along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finishes complete all as specified. Note: GI Pipe will be measured and paid seperately in respective item.
M&L for cement concrete 1 : 4 : 8 type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work all as specified and directed
M&L for cement concrete 1 : 2 : 4 type B-1 using 20 mm graded aggregate as in foundation ,filling and mass concrete necessary form work all as specified and directed by Engr-in-Charge.
S&F in repair of street light juction box of size 200mm x 160mm x 98mm, top hing door type, complete with 4 way connector - 01 No,6 Amps SP MCB - 01 No, fixing on street/security light pole of any type with suitable MS clamp, nut, bolts, washers and cable gland for each connection complete all as specified and as directed by Eng-in-Charge.
M & L for spreading evenly stone aggregate of size 40 mm in Sub Stn area complete all as directed by Eng-in-Charge.
M&L in replacement of Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed by Eng-in-Charge.
S&F Gate Light fittings, decorative type, LED 40Watt, all including fixing material on gate posts complete and connected to neares electric pole all as specified and as directed by Eng-in-Charge.
S&F Energy efficient LED street light fittings, 90 Watt, die-cast aluminium body with power LED and dirver with IP66 protection and 10KV built-in-surge protection device complete all as specified and as directed.
S&F street light bracket made out of GI tubing 40mm bore, 1.5 metre long bent to shape as directed, including suitable MS clamp with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete all as specified and as directed by Eng-in-Charge.
S&F LED bollard light fittings, LED 10Watt, all including fixing material and earth work complete and connected to neares electric pole all as specified and as directed by Eng-in-Charge.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular of size 6 Sqmm all as specified and as directed by Eng-in-Charge
All as per item No 35 above but of size 10 Sqmm.
S & F in repair LED flood light fittings for area lighting 150 Watt made out of pressure dia cast aluminium housing with IP66 protection and 10 KV SPD all as specified and as directed by Eng-in-Charge.
Leo Enterprises
Veekay Enterprises
ONKAR ELECTRIC AND GENERAL STORE
Urja Techniques India Pvt. Ltd.
M/S. OM ENTERPRISES
SHAILENDRA B TULSANI
SBS Enterprises
M/S. Niksun Electro-Infra Private Limited
Rama Electricals
KESARI AND SONS
Techmat trading solution
Star Electrical
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .