Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L1 | Accepted-AOC ok | |
| 2 | L2₹9.0 L+₹20,312.84 (2.31%)Rejected-AOC | L2 | Rejected-AOC ok |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
31 Aug 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
Provision of associated work services for portable water supply from NMC in TXR at AF station Sonegaon Nagpur
2020_MES_361673_2
8336/E8
Open Tender
Civil Works
Item Rate
180 days
Sonegaon
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon, Nagpur
₹17,000
Yes
17 Sept 2020
14 Aug 2020
1 Sept 2020
14 Aug 2020
31 Aug 2020
17 Aug 2020
14 Aug 2020 - 14 Aug 2020
60 days
Amount
Excavating over areas, n exc1.5 m deep and getting out soft/loose soil all as specified and directed.
Excavating over areas, exc1.5 m deep and getting out Hard/dense soil all as specified and directed.
Excavating over areas, exc1.5 m deep and getting out Hard/dense soil all as specified and directed.
Excavating in trenches nexc1.5m wide and nexc 1.5m in depth for foundation of poles,stays, laying of UG cables/pipes & getting out in soft/loose soil complete all as specified and directed
Excavation in trenches nexc 1.5m wide and nexc 1.5 m in depth and getting out in any type of soil for laying of cable all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick Hard dense soil all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick soft/loose soil all as specified and directed
Removing excavated material (soil) n exc 50 and depositing where directed at a level n exc. 1.5 m above the starting point
Removing excavated material (soft/disintegrated rocks) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for providing dry river sand as in sand cusioning for underground cable protection incl punning down sand in layers complete all as specified and directed. Note- Only punning thickness of sand shall be considered for measurement purposes.
Supplying and laying common burnt clay sub-class B bricks of size 230 mm X 113 mm X 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed
M & L road cutting of size 30 cm width x 45 cm width for laying of cables incl making good road with necessary returning filling and bituminous portion with concrete and bituminous mixture and cemented portion with PCC 1:2:4 , 15 cm thick from top and matching the surfaces with existing all as specified and directed.
M&L for brick masonry with subclass B bricks 6 metre mean radius in cement mortar 1 : 6 all as specified
M&L for PCC coping 1:2:4 type-B1 using 20 mm graded stone aggregate all as specified.
M&L for rendering with 15 mm thick in cement mortar 1:4 on fair surfaces of brickwork or concrete surfaces finished even and smooth surface without using extra cement all as specified and directed
M&L for PCC (1:4:8) type-D2, using 40 mm graded stone aggregate as in sub base, filling and mass-concrete complete all as specified and directed.
M&L for M30 (20mm graded aggregate) Reinforced cement concrete (design mix) for RCC wall for UG sump etc all as specified and directed.
M&L for M30 (20mm graded aggregate) Reinforced cement concrete (design mix) for Floor Slabs supported on beams, RCC dome etc all as specified and directed.
M&L for M30 (20mm graded aggregate) Reinforced cement concrete (design mix) for Cover Slabs supported on beams, RCC dome etc all as specified and directed.
M&L for M30 (20mm graded aggregate) Reinforced cement concrete (design mix) for RCC beam for UG sump etc all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, fair finished surface all as specified and directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter rough finished surface all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc.fair finished surface all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, lintels, cantilevers butcurved surface etc. also splays between floors and beams, etc.fair finished surface all as specified and directed.
S&F for TMT bars 10mm dia and over, cut to length, bent to shape required including craking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.
S&F for TMT bars 6 to 8mm dia, cut to length, bent to shape required including craking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.
- Ditto -all as per item no- 27 but 5 mm dia and over upto and including 10 mm dia as in Stirups,spacers and binders etc
M&L for 230 mm wide PVC Water Bar alround at construction joints make: FOSROC, SIKA, SIKA NATURAL)
M&L for 12mm thick rendering CM 1:3 on fair faces of brick work or concrete surface using water proofing compound/admixture confirming to IS 2645-1964 (WPC shall be measured separately).
M&L Preparation new plastered surfaces of walls and applying one coats of water proof cement base paint (Make : Dr. fixit, Pedilite & FOSROC)
Supply only Liquid water proofing compound/admixture confirming to IS 2645-1964 (Make : Dr. fixit, Pedilite & FOSROC)
M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, ncluding bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') all as specified and directed for adder and manhole.
M&L for MS Plates (chequered) channels, square cut or notched or circular(ordinary and counter sunk) forming holes, with rivetted, bolted or welded attachment all as specified and directed for opening or manhole.
Preparation to new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coat of Synthetic enamel paint over a redoxide etc.
S & F 100mm AC vent pipe with ACCOWL are to be provided in sump and height of AC pipe shall be 1.2m from top of slab and the cowl to be protected with moisquito proof wire net and fixed complete all as specified and directed
M&L Preparation new plastered surfaces of walls and applying three coats of white wash.
M&L Preparation new plastered surfaces of cover slab and applying three coats of white wash.
Supply and Laying GI pipe Light grade (ISI marked) 50 mm bore with connecting accessories, laid under road / drain / fixed on wall etc for protection of cables complete all as specified and directed.
Supplying, laying, testing and commissioning cable XLPE insulated aluminium conductor, stranded, armoured, PVC sheathed , LT 1100 volt grade , heavy duty as per IS 7098 and providing suitable legs and cable glands, laid in trenches/ ducts/ fixed to wall / roof/ poles incl taking down existing cables complete all as specified and directed of following size : (a) 50 sqmm , 3.5 core
S&F MCCB 100 A 415 Volts 16KA breaking capacity, AAN frame fixed on existing panel in power house/ feeder pannel and connecting up all as specified and directed in the process of MCCB, minor drilling, clamping, screw, nut bolt included in quoted rate (Havells / Hager / Legrand)
Supply and laying of GI tube with medium grade with all fittings incl cutting for branch line & making threads complete fixed to wall / flooring / ceiling etc or laid in trenches all as specified (a) 20 mm bore
Supply and laying of GI tube with medium grade with all fittings incl cutting for branch line & making threads complete fixed to wall / flooring / ceiling etc or laid in trenches all as specified (a) 40 mm bore
Supply and laying of GI tube with medium grade with all fittings incl cutting for branch line & making threads complete fixed to wall / flooring / ceiling etc or laid in trenches all as specified (a) 40 mm bore
Supply and fix gun metal globe or gate valves with iron wheel head screwed both ends for GI pipe all as specified : (a) 20 mm bore
Supply and fix gun metal globe or gate valves with iron wheel head screwed both ends for GI pipe all as specified : (a) 40 mm bore
Supply and fix gun metal globe or gate valves with iron wheel head screwed both ends for GI pipe all as specified : (a) 50 mm bore
Supply and laying of GI tubing heavy grade with all fittings incl cutting for branch line & making threads complete fixed to wall / flooring /ceiling etc or laid in trenches all as specified (a) 65 mm bore
Supply, install, testing and commissioning horizontal submersible pumping set electric driven of capacity 7.5 HP having suction 65 mm & delivery 50 mm size suitable for 3 phase , 415 volts 50 Hz AC supply incl necessary submersible cable, PCC foundation Nuts/ Bolts & washers complete all as specified & directed. (Make- Kirloskar model No- KOS- 1065+M or equivalent )
S &F DOL starter of 5HP/ 7.5HP incl relays, contractor etc after taking down removing all electric connection and fitted the same to its orginal position complete all as directed
M/s Rahul Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .