Loading…
Loading…
Tender Value
₹2.7 Cr
EMD Value
₹5.4 L
Closing Date
25 Mar 2026, 5:30 amClosed
Engine Division, Koraput
HINDUSTAN AERONAUTICS LIMITED Engine Division, Koraput, Sunabeda- 763002
Provisioning of Decorative Light for Pathway Road of HAL Township up to a Length of 12 Kms
24861
SNC/25CAREM-1010/1
Limited
Works
Mig Complex- Engine Divn-Sunabeda-Koraput-Works
| # | Company Name | Location | Address |
|---|---|---|---|
| 1 | ENERGYGREEN TECHNOPOWER PVT LTD | BHOPAL,India | 32/2, SECTOR-E, INDUSTRIAL AREA, GOVINDPURA, BHOPAL-462023, MADHYA PRADESH,,BHOPAL,Madhya Pradesh,India,Pin-462023 |
| 2 | DIGITAL ENGINEERING PROJECTS PVT. LTD. | AHMEDABAD,India | 10, KANKARIA APT. OPP. SARDAR PATEL HO. RAMBAUG,MANINAGAR, AHMEDABAD,,AHMEDABAD,Gujarat,India,Pin-380008 |
ENERGYGREEN TECHNOPOWER PVT LTD
BHOPAL,India
32/2, SECTOR-E, INDUSTRIAL AREA, GOVINDPURA, BHOPAL-462023, MADHYA PRADESH,,BHOPAL,Madhya Pradesh,India,Pin-462023
DIGITAL ENGINEERING PROJECTS PVT. LTD.
AHMEDABAD,India
10, KANKARIA APT. OPP. SARDAR PATEL HO. RAMBAUG,MANINAGAR, AHMEDABAD,,AHMEDABAD,Gujarat,India,Pin-380008
₹0
₹5.4 L
24 Feb 2026
24 Feb 2026
24 Feb 2026
25 Mar 2026
Supply of 45 W tear drop pendant pathway luminaires complete with spun aluminium housing and pressure die-cast heat sink, ring spun aluminium with black finish powder coating, clear polycarbonate cover, mains terminal 3-way 10 A suitable for terminating up to maximum 2.5 sq. mm incoming cable, cable entry through mounting pipe, stainless steel hardware, IP65 ingress protection, potted driver BIS approved (electrical safety as per IS 15885) with high surge protection including 4 kV internal and 10 kV SPD, electrical protections against high voltage and short circuit, rated voltage 240 V, frequency 50 Hz, operating voltage range 120–270 V, current 0.657 A @ 240 V, wattage 45 W @ 240 V, reverse polarity and open voltage protection, THD 0.95, and correlated color temperature (CCT) 3000 K ( WARM WHILTE), complete in all respects as per specifications. The product must hold a valid GreenPro Ecolabel certification issued by the CII - Green Products & Services Council and to be submitted along Technical Bid.Warranty shall be 3 years . Make: Bajaj / GE Lighting / Lighting Technology / Wipro / Philips / Crompton / Havells / Jaquar / Surya / Energy Green/ orient.
Supply and installation of Bakelite sheet complete with one 16 A single pole MCB, MCB channel, and 16 sq. mm 100 A stud type connectors (4 numbers) mounted inside the pole at the door opening, suitable for safe and secure cable connection, complete in all respects as per specifications and site requirements..Make : Schneider, ABB, Legrand,Siemens
Supply of 1.1 KV 4CX50 SQ MM Aluminum Armored cable for incoming power supply from nearest existing LT panel/ Substation LT panel to Feeder piller panel( 10 Nos) of Path way Light.Make:Havells/Universal/KEI/Polycab/Gloster/Polycab/RR Cable.
Supply of 1.1 KV 4CX16 SQ MM Aluminum Armored cable for pole to pole underground cable laying including incoming from Feeder piller to pole. Make:Havells/Universal/KEI/Polycab/Gloster/Polycab/RR Cable.
Supply of 7.5 KW RF or GPRS/GSM based smart streetlight Gateway Controller system with integrated CCMC (Central Control & Monitoring Centre) software, capable of automatic scheduling of ON/OFF operations based on real-time clock and annual sunrise/sunset data, remote monitoring via 4G/2G communication, emergency wireless control, and self-protection against short circuit, over/under voltage, surge and theft. The system shall provide real-time and periodic data on voltage, current, power factor, active power, cumulative energy and lamp burning hours, generate configurable alerts (electrical faults, MCB trips, door open, relay failure, communication failure, theft, group lamp failure, etc.) forwarded to Android apps, and support AES-128 encrypted communication. Controllers shall be IP55/IP65 compliant, designed for ≥10-year life,rated at minimum twice the connected load, with external latching relay switching, auto MCB trip rectification, ISI marked Class 1.0 (or better) energy meter compliant to IS:13779, dual-band low-power modem, GPS, RF mesh networking, and wide operating temperature range.The CCMS should have manual operating option for auto ON/ OFF the feeder when the network / internal sytem failure. The CCMC shall be cloud-based, scalable (minimum 4000 devices), GIS-enabled, role-based secure, API-ready for ICCC integration, support analytics, reporting, asset and complaint management with citizen interface, mobile commissioning app, firmware upgrades, and demonstrate all specified features during technical evaluation. All hardware (including MCBs, load break switches, surge protection devices) shall comply with relevant IS/IEC standards. The above price including Rechage of 5 year SIM & free spare metrials for any defect for 3 years. Make: Crompton / Schnell/BAJAJ/HAVELLS/SURYA/ Orient.
Supply of 1.5 sq. mm × 3 core copper round flexible cable for connection from light fittings to internal junction box, complete with all required accessories, handling and installation as per site requirements, suitable for electrical installations, and complete in all respects as per specifications and directions of the Engineer-in-Charge. Make: Havells / Universal / KEI / Polycab / Gloster/ RR Cable/ Mescab.
Supply and installation of coil earthing up to 0.5 m from the street light foundation, including excavation, placement, backfilling and proper compaction, complete with supply of suitable size nuts, bolts and washers, and making proper and secure earth connection to the street light pole, ensuring effective earthing as per relevant standards, complete in all respects as per specifications and directions of the Engineer-in-Charge.complete in all respects.
Construction of M-20 grade RCC foundation (1:2:4) with nominal reinforcement for lighting poles, including provision of two numbers flexible PVC pipes of suitable diameter inserted within the RCC foundation for cable entry, complete with supply and fixing of anchor/tor rods, excavation in all kinds of soil, shuttering, concreting, backfilling, curing and all associated works, strictly as per approved drawings or as directed by the Engineer-in-Charge, complete in all respects.
Shifting, installation, testing and commissioning of pathway light poles including erection of poles using suitable equipment, tools and labour, fixing of light fittings complete with all accessories on single arm bracket, electrical connection using designed capacity and size copper conductor and Bakelite sheet arrangement, including supply and fixing of lugs, PVC insulated cable from luminaire at top to terminal block mounted at the bottom of the pole, proper earthing connection to the earth point of the pole, and complete testing and commissioning of the entire system to ensure safe and satisfactory operation, all as per specifications and directions of the Engineer-in-Charge, complete in all respects.
Installation of outdoor feeder pillar box for pathway lighting by erecting the feeder pillar on the approved cement concrete foundation and grouting it properly in the CC foundation, including making complete electrical connections of incoming and outgoing cables, and including supply and fixing of suitable size double compression glands, cable lugs, PVC insulation tape and all other necessary accessories under vendor’s scope, complete in all respects as per specifications, approved drawings and directions of the Engineer-in-Charge.
Excavation of cable trenches and laying of 1.1 kV grade underground cables along and across roads, including protection of cables by covering the trench with HDPE pipe wherever required, and providing suitable size reinforced spun concrete pipe or GI pipe where the cable passes through roads, complete with supply and fixing of aluminium lugs, PVC insulation tape, and proper end terminations, including all materials, labour, tools and equipment necessary for execution of the work; the contractor shall collect the cables from the store using own labour, tools and transportation, restore the surface to its original condition after completion of cable laying, and carry out insulation resistance (IR) testing of the cables before and after laying, all complete in all respects as per specifications and directions of the Engineer-in-Charge.The route of cable laid from Incomer to Feeder Pillar and From Feeder pillar to Pole should be followed by Cable Route tracer marker with minimum distance of 50 Mts for the said project.
Supply, installation and Testing of chemical earthing arrangement for feeder pillar using 3 meter long, 50 mm diameter, 3 mm thick copper-coated steel earthing electrode, including excavation, backfilling, and all associated works. The earthing system shall comprise approved chemical earthing compound (bentonite/graphite or equivalent) to ensure low earth resistance, along with earth enhancement material, inspection chamber with cover, watering arrangement, GI strip or wire connections, clamps, nuts and bolts, and termination at equipment. The installation shall be carried out as per relevant IS standards and site requirements, ensuring proper continuity, mechanical strength, corrosion resistance, and achieving the specified earth resistance value, complete in all respects.Make : Zeme India, Avon, Itorrent, Ashlok Safe, SG Power, Veraizen earthing, Zeme India, Laxmi Power, NCR Enterprises.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
ENIT.pdf
TENDER_DOCUMENT • 1.83 MB
NEWGCC.pdf
TENDER_DOCUMENT • 2.92 MB
BOQVIEW.pdf
TENDER_DOCUMENT • 0.21 MB
EBOQ.xlsm
TENDER_DOCUMENT • 0.02 MB
TURNOVER.pdf
TENDER_DOCUMENT • 0.33 MB
UndertakingFormat.pdf
TENDER_DOCUMENT • 0.08 MB
CHECKLIST.pdf
TENDER_DOCUMENT • 0.21 MB
EPSMandateFormat.pdf
TENDER_DOCUMENT • 0.12 MB
WORKINHAND.pdf
TENDER_DOCUMENT • 0.28 MB
Download all tender documents and submit your bid