| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹35.9 L+₹1.3 L (3.84%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹38.5 L+₹3.9 L (11.3%)Rejected-Finance BLDG 9 FLAT 130 MIRA CO OP HOUSING SOCIETY LTD SALISBURY PARK GULTEKDI PUNE 411037 | PUNE | PUNE | MAHARASHTRA | 411037 | L3 | Rejected-Finance Bidder not quoted L1 rates | |
| 4 | L4₹41.6 L+₹7.0 L (20.4%)Rejected-Finance | L4 | Rejected-Finance Bidder not quoted L1 rates | |
| 5 | L5₹43.0 L+₹8.4 L (24.3%)Rejected-Finance 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L5 | Rejected-Finance Bidder not quoted L1 rates |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEERS PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85883 PROVN OF STORAGE ACCN FOR COMMAND HOSPITAL (SC) UNDER GE (SOUTH) PUNE
2024_MES_639574_1
85883 CWE PUNE
Open Tender
Civil Works
Item Rate
183 days
GE (SOUTH) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹90,000
Yes
1 Apr 2024
29 Jan 2024
4 Mar 2024
29 Jan 2024
2 Mar 2024
19 Feb 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches (not exceeding 1.5 m width or not exc 10 sqm on plan) , incl dressing of sides and ramming of bottoms and lift upto 1.50m, incl getting out the excavated material and disposal of surplus soil as directed within a distance of 50m in any kind of soil complete all as specified and as directed.
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches (not exceeding 1.5 m width or not exc 10 sqm on plan) , incl dressing of sides and ramming of bottoms and lift upto 1.50m, incl getting out the excavated material and disposal of surplus soil as directed within a distance of 50m in any ordinary rock complete all as specified and as directed.
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches (not exceeding 1.5 m width or not exc 10 sqm on plan) , incl dressing of sides and ramming of bottoms and lift upto 1.50m, incl getting out the excavated material and disposal of surplus soil as directed within a distance of 50m in any hard rock complete all as specified and as directed.
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches (not exceeding 1.5 m width or not exc 10 sqm on plan) , incl dressing of sides and ramming of bottoms and lift exc1.50m but nexc 3.0m, incl getting out the excavated material and disposal of surplus soil as directed within a distance of 50m in any hard rock complete all as specified and as directed.
M&L for PCC in 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundation complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for Rough finished surface of concrete flat complete all as specified and as directed.
M&L for formwork to sides of pillars,posts, struts, piers, columns and stanchions for rough finished surface of concrete flat complete all as specified and as directed.
M& L formwork to sides and soffits of floor or roof beams, beam hunchings,girders, bressummers,lintels, cantilevers, shelves including sup- orts, overhangs,etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items cluding edges etc. complete all as specified and as directed.
M&L for formwork to Rough finished surface of concrete sides and soffits of roof slab not exceeding 200mm thick including supports, overhangs complete all as specified and as directed.
M & L for Formwork to Rough finished surface of concrete edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide complete all as specified and as directed.
M&L for mild steel bars 10mm dia and over , cut to length , bent to shape required including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) 0.9mm dia or securing with clips quality confirming to TMT bars complete all as specified and as directed.
All as per Ser. Item No 12 above but 6-8 dia bars complete all as specified and as directed.
M&L for mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length , bent to shape required including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) 0.9mm dia or securing with clips quality confirming to TMT bars complete all as specified and as directed.
M&L for RCC M-25 Design mix for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 Design mix for Columns, pillars, piers,posts and struts complete all as specified and as directed.
M&L for RCC M-25 Design mix for Beams, cantilevers, bressummers, lintels over1.5m span complete all as specified and as directed.
M& L for RCC M-25 Design mix for Chajjas complete all as specified and as directed.
M& L for RCC M-25 Design mix for Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for Treating the back fill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L for treating the soil of backfill and under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall ith backfill to be measured) of emulsion per square metre of surface area complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and as directed.
Removal of excavated material exc 1.50 Km. & n exc 5 km & depositing outside of MOD Land complete all as specified and as directed.
M & L for AAC block masonary , straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed by Engr-in-Charge.
M&L for hand cut Kota stone in flooring and window cills of required size and 15 to 20 mm thick; laid, jointed with grey cement slurry and pointed with coloured cement to match the shade of Kota stone as in floor etc. including rubbing and mirror polishing complete; laid over and including screed bed 15mm thick in CM 1:6 complete all as specified and directed. (Note: Kota stone shall be provided with bull nosing for tread slab & 2 Nos of 5mm thick anti skid grooves at one edge complete all as specified and as directed.
M&L for Prepolished machine cut Kota stone15 to 20mm thick single piece as in risers and skirting of staircase etc and of size as required at site, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of kota stone slab laid over and including 10mm thick screed bed/backing coat in CM 1:4 complete all as specified and as directed.
M&L for 100mm plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed
M&L for 100mm thick cement concrete type B- 2,1:2:4 (40mm graded aggregate) as in floors finished even and smooth with broom finish/Xpm impressions as in ramp complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1: 6 on fair faces of AAC/PCC block work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in two layers (10mm+5mm) in cement mortar 1:4 & with water proofing compound on other than fair faces of brick work/block masonry or concrete surfaces complete all as directed. (Note :- WPC will be measured separately)
M&L for rendering 5mm thick in in cement mortar 1:3 on ceilings other than fair faces of brick work/block masonry or concrete surfaces complete all as specified and as directed.
Supply only of Liquid water proofing compound complete all as specified and as directed.
M&L for rendering 15mm thick on roof surfaces in cement mortar 1: 3 & with water proofing compound on other concrete surfaces complete all as directed. (Note :- WPC will be measured separately)
M&L for water proofing treatment to RCC roof slabs, walls, chajjas etc shall be carried out as specified below and as directed by Engineer-in-Charge. (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces when concrete is green. (b) Preparing plastered surfaces of roof slab, walls, chajjas etc by brooming with broom sweeping free from dust etc and evenly applying a coat of approved bituminous primer @ 0.70 Kg/Sqm of area, complete all as specified. (c) Laying 3mm thick APP polymer modified approved membrane non woven, polyster weighing not less than 3.60Kg/Sqm with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engineer-in-Charge. Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE. (d) Finally applying two coats of solar reflective bitumastic aluminium paints on the top of membrane surfaces complete all as specified and as directed by Engineer-in-Charge.
Preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Preparation of new plastered surfaces of walls & one coat of primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio 5:4:1 followed by application applying two coats of weather proof exterior emulsion paint which gives 5 year of performance warranty complete all as specified & directed.
Preparation of new plastered surfaces on celing and applying three coats of white wash over a coat of Chalk whiting, primer complete all as specified and directed.
M&L for hardcore of (broken stone or boulder) gauge nexc 63mm , deposited, spread levelled in layer nexc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm cement concrete type C2 1:3:6 (20mm graded stone aggregate) as in plinth protection with necessary joints filled with bituminous filler material and formwork all as specified and directed.
S&F steel window with side hung shutter incl projecting type hinges with steel handle and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and as directed.
S&F steel ventilator fixed type complete with glazing bars dovetailed or welded complete all as specified and as directed.
S&F sheet glass 3mm thick ordinary quality and glazing with oil putty in square nexc 0.50sqm each pane complete all as specified and directed
M&L for MS framed work conforming to grade E-165 (Fe-290) or Fe-310-O of MS angle or other sections, such as grills, gratings with ends of bar shouldered and / or riveted or forged into spikes; framed guard bars; railings and like completed all as directed
S&F Steel rolling shutters 1.25mm thick ,gear operated type with chain wheel and hand chain as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed.
M & L for preparation of new steel surface exceeding 10 Cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide complete all as specified & directed.
M & L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including removing old paver blocks.
S & F pressed steel frames for doors with one or more rebates incl necessary hold fasts, hinges, lock strike plate etc complete with a shop coat of red oxide primer as specified size of frame 105 x 60mm filled with PCC 1:3:6 type C-0 T6 complete all as specified and as directed.
S&F 30mm thick flush shutters, solid core construction with block board core construction with block board core and plywood face panells commercial type on both faces incl 6mm thick 1st class HW (Teak wood) beading all around on edges complete all as specified and directed.
M & L for preparation of new wood surface exceeding 10 Cm width or girth and apply two coats of synthetic enamel paint over a cots of pink primer complete all as specified & directed.
S&F of 100mm long stainless steel butt hinges, medium weight and fixed complete all as spd and as directed.
S&F of powder coated 150mm size aluminium handles, fabricated type, anodised and fixed complete all as spd and as directed.
S&F in repair powder coated 200mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F in repair 150mm Floor door stopper of aluminium alloy body and tongue, powder coated with hard drawn steel spring, fixed in floor complete all as spd and as directed.
S&F of powder coated 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
M&L for non - skid Ceramic colored tiles 7 to 8 mm thick quare/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as spd and as directed.
M&L for coloured glazed ceramic tiles in vertical surface 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick plaster in CM 1:4 complete all as spd and as directed.
M&L for 20-25mm thick machine cut cudappah stone slabs, fixed independently in shelves for cooking platform and the like etc complete all as specified and as directed.
M&L for 18 to 20mm thick Granite (of any type/colour) work (table rubbed and polished) in steps, pillars;window cills/jamb, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. as counters of any radius etc laid over and including 15mm thick screed bed in Cement Mortar (1:6) complete all as spcecified and directed.
Rounding to edges of stone slabs and polishing in edges, such as in steps,shelf cooking platform, and other similar situations complete all as specifed and directed.
S&F GI tubing 15mm bore "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. of the following sizes :-
S&F GI tubing 25mm bore "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. of the following sizes :-
S&F in repair 15 mm bore pillar taps, fancy type,Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot or Cold" with long screwed shanks and fly nuts, screwed for iron pipe etc complete as specified and directed.
S & F in repair angle cock, 15mm bore brass chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC connection 45 cm long 15 mm bore with 2 Nos brass check nuts fixed complete all as specified and as directed.
S&F in repair vitreous china wash hand basin white Oval shape Under counter Basin with Fixing Accessories,CAT ID-FLS-WHT-5701Size: 560x430x195 mm of "Jaquar" or of Equivalent make complete all as specified.
S&F high density 32 mm bore polyethylene (HDPE) pipe of pressure rating 6 kgf/sqcm complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm bore single sockted pipe in any length with rubber ring joint, laid in trenches or in floor complete all as specified and as directed.
M&L for PVC (SWR) gully trap 125/110mm setting and jointing with solvant cement complete all as specified and as directed.
M&L for PVC door bend 75mm bore complete all as specified and as directed.
M&L RCC pipes class NP-3 with socketed ends laid and jointed complete of 100mm bore complete all as specified and as directed.
M&L for concrete 1:3:6 type C-2 bed to drain pipes incl packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and as directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified and directed
Demolition of stone slab/pcc tiles/paver block any description or thickness in floors/aprons etc laid dry and pointed in any mortar complete all as specified and as directed.
M&L for 150mm thick cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate as in subbase of path complete all as specified and as directed.
M&L for Cement concrete Design mix M-25 as in hard standing finished even and fair complete all as specified and directed.
Spike rolling to surface or making impression of expanded metal, while concrete is green complete all as specified and as directed.
Forming construction joilns 30mm deep and 10mm wide filled with sealing compound complete all as specified and as directed.
M&L for Providing precast cement concrete solid block masonry exc 10 cm in width and setting in cement mortar1:6 complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 & with block masonry or concrete surfaces finished even and fair complete all as as specified and directed
M&L for providing cement concrete as in surface channels and drain complete all as specified and as directed.
Extra for forming fair finish to drain or channel 30cm inner girth in cement concrete using extre cement incl forms moulds, metred/stopped ends etc complete all as specified and directed
All as per Ser. Item No. 86 above but to Add or deduct for each 25mm girth or part thereof over or under 30cm complete all as specified and as directed.
Cutting hole into existing brick wall one brick thick for connecting sewage/ drainage line and sealing/ making good with cement mortar 1:3 complete all as specified and directed
M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for One light/Fan point controlled by one way switch 6 Amps 240 volts complete all as specified and as directed.
All as per item No. 89.00 above but One 3 pin 6 Amps socket out let point on independent board complete all as specified and as directed.
All as per item No. 89.00 above but One 3 pin 6 Amps socket out let point on same board complete all as specified and as directed.
M&L for point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit complete all as specified and as directed.
S&F modular switch 1 way 10 A 1 module complete all as specified and as directed.
S&F Modular socket 6 A 2/3 Pin 2 module. Complete all as specified and as directed.
S&F Modular socket 6A/16A - 2/3 Pin 2 Module complete all as specified and as directed.
S&F modular switch 1 way 20 A 1 module with neon indicator complete all as specified and as directed.
S&F modular Fan regulator step type, 2 module complete all as specified and as directed.
S&F ceiling rose surface shall comply with IS:371-1979 Bakelite 60x 25 mm two to three terminals plates and of outside diameter not less than 63.5mm complete all as specified and as directed.
S&F ceiling fan complete with blades, down rod of suitable length and other accessories, 230 V, 1200 mm sweep BEE Five star rated with brushless direct current motor (BLDC), white/Ivory in colour all as specified and directed.
S&F exhaust fan made of sturdy engineering plastic of sweep 250 mm,single phase 230V with louvers and making hole as per the required size of the exhuast fan on wall/Aluminium window and making good the disturbed surfaces complete all as specified and directed by Engr-in-charge.
S&F in replacement of 20watt, 230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified. Make- Luker LT5M20 / Havells ENDURALINEARNEOBS20WLED865SPCWH / Bajaj BCLAB 20W WH LED P
S&F LED building security light fiitting 30/35 W,IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens complete fixing with bracket of adequate length made from GI pipe 25 mm, incl electrical connection from connector to light fitting. and fixed to wall with necessary MS clamp accessories complete all as specified and directed by Engr-in-charge.
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 way (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout and making good disturbed surface and touch up with the same finishes complete all as specified and as directed.
S&F MCCB with rating of 40 Amps, 415Volts 3 pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and as directed.
S&F MCB DB 08 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete as reqd at site complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and as directed.
S&F MCB SPN 40 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including surface, Non metalic rigid PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Note : Three runs of 04Sqmm cable including earth wire along with casing caping shall be measured as one RM)
Supply,laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 35 Sqmm 3.5 core complete all as specified and directed.
M&L for laying reinforced concrete pipes, class NP2 of dia 80 mm, 2 nos half round (for bottom and top) and before laying exacaved area shall be leveling all as specified and directed Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in the following type of strata complete all as specified and as directed by the Engineer-in-Charge.
Soft/Loose soil
Hard/ Dense soil
Soft/disintegrated Rock
Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed by the Engineer - in - Charge.
Design, supply,install, test and comissioning of free standing floor mounted, dust and vermin proof LT Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 250 ,Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkaable sleeves,with 600 mm depth of the panel. The panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc
INCOMING :- (a) MCCB 4 pole 160 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming OUTGOING :- (a) MCCB 3 pole 100 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 01 Nos Out going (b) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 01 Nos Out going (c) LT Danger notice plate -01 No (d) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
Material and labour for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore for fixing 50 mm dia pipe in road crossing etc. including the cost of making good the disturbed surface and matching with existing (Chequered tiles/Road/PCC) complete all as specified and directed by Engr-In-Charge
Supply & fix GI tubing medium grade 50 mm dia ISI marked with all fittings laid in trenches for cable protection all as specified and directed at size.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanised iron strip 32 x 6 mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 15 mm dia (medium grade) including concrete pit in PCC (1:3:6) type C-1, RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
Gauri Associates
Vijay Construction and Company
DAKSH ENGINEERS AND BUILDERS
M/s.BAJRANG CONSTRUCTION
M/s DEVRATAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .