Pardeep
Executive Engineer (E), Madhuban
REPAIR and COMPREHENSIVE ANNUAL MAINTENANCE
2026_HBC_558150_1
20265E536D78 0B5E 4CC1 90F3 08FEAF1E28B057HHC
Open Tender
Electrical Works
Works
150 days
Karnal Sonepat Jhajjar Sirsa
2 documents required · 2 mandatory
₹17,700
₹2.8 L
Yes
3 Nov 2026
3 Nov 2026
14 Nov 2026
3 Nov 2026
13 Nov 2026
3 Nov 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | HSR PART
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] | 4 | Each | 145 | ₹580 |
| 2 | [23.28.3.1]Supplying, installation, Testing and Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 1. Powder coated die cast / Extruded aluminum Body including trim 5-7 watt [Rate] | 60 | Each | 700 | ₹42,000 |
| 3 | [37.4.3]All in all comprehensive maintenance after defect liability period of the passenger/bed cum stretcher /goods elevator having various speed as per OEM guidelines and maintenance manual including car with all car accessories, hoist way accessories and complete with machine room accessories but excluding replacement of diffused battery bank of ARD system as per following details 3. 10 Passenger, 680 Kg Elevator up to 5 Stops [Rate] | 120 | Job P. Month | 8,660 | ₹10,39,200 |
| 4 | [37.4.4]All in all comprehensive maintenance after defect liability period of the passenger/bed cum stretcher /goods elevator having various speed as per OEM guidelines and maintenance manual including car with all car accessories, hoist way accessories and complete with machine room accessories but excluding replacement of diffused battery bank of ARD system as per following details 4. 13 Passenger, 884 Kg Elevator up to 5 Stops [Rate] | 732 | Job P. Month | 9,851 | ₹72,10,932 |
| 5 | NS PART
Providing NOC from Chief Electrical Inspector Haryana for 10/13/16 passengers Lift including 3rd party Insurance for one year from reputed Insurance companies registered with IRDAI complete reqd. Fees and all other documentation formalities as required. | 71 | Each | 13,408 | ₹9,51,968 |
| 6 | Repair of lift bearing no. Equipment: ELN2002948 (Make- ORBIS) with replacement of below mentioned parts including repair and overhauling charges complete in all respect upto the entire satisfaction of the Engineer-in-charge of the work.
1. Supply of Emergency Alarm
2. Supply of Car Light
3. Supply of ARD Main Card
4. Supply of ARD Charging Card
5. Supply of ARD Battery
6. Supply of Car Shoe Liner
7. Supply of CWT Shoe Liner
8. Supply of Car Fan | 1 | Each | 59,505 | ₹59,505 |
| 7 | Providing and fixing SMF VRLA Battery Set (12V,12 Ah) for Automatic Rescue Device (ARD) of Lift, including , wiring, connectors, testing and commissioning, complete in all respects. | 90 | Each | 2,929 | ₹2,63,610 |
| 8 | Repair of lift bearing no. Equipment: ELN2203467 (Make- ORBIS) with replacement of ARD Batteries 6 Nos, SMPS, Full Length Door Curtain with Accessories, Emergency Alarm, Intercom Unit and 6 Nos Car LED Light including repair and overhauling charges complete in all respect upto the entire satisfaction of the Engineer-in-charge of the work | 1 | Each | 56,018 | ₹56,018 |
| 9 | Repair of lift bearing no. Equipment: ELN2203468 (Make- ORBIS) with replacement of ARD Batteries 6 Nos, ARD Contactor ( 415 V ), Door Drive, LOP Push Button ( UP/Down ) 5 Nos, Emergency Alarm, Intercom Unit, Safety Switch, Pit Switch and 6 Nos Car LED Light including repair and overhauling charges complete in all respect upto the entire satisfaction of the Engineer-in-charge of the work. | 1 | Each | 75,851 | ₹75,851 |
| 10 | Repair of lift bearing no. Equipment: ELN2203469 (Make- ORBIS) with replacement of ARD Batteries 6 Nos, Photo Cell Switch 2 Nos, SMPS, Limit Switch 2 Nos, ARD Main Card, ARD Contactor ( 415 V ) and 6 Nos Car LED Light including repair and overhauling charges complete in all respect upto the entire satisfaction of the Engineer-in-charge of the work. | 1 | Each | 68,239 | ₹68,239 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_638151.xls
BOQ • 0.35 MB
8F59D5Z182547.pdf
Additional Documents • 9.33 MB
OT0182547.pdf
Other Document • 2.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .