Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹52.9 L+₹4.5 L (9.19%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹56.4 L+₹8.0 L (16.5%)Rejected-AOC 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹57.0 L+₹8.6 L (17.7%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L4 | Rejected-AOC REJECTED |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Nov 2023, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
MAINT OF MISC B/R AND E/M WORKS INCLD PLUMBING WORK, SUNKEN REPAIR, WPT, REPAIRS TO WINDOWS AND OTHER CONNECTED ITEMS OF CERTAIN BLDGS AT INS HAMLA UNDER GE(NW) BHANDUP
2023_MES_623318_1
8297/B
Open Tender
Civil Works
Item Rate
270 days
Hamla
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹90,000
Yes
11 Feb 2024
14 Oct 2023
25 Nov 2023
14 Oct 2023
23 Nov 2023
2 Nov 2023
14 Oct 2023 - 24 Oct 2023
Amount
Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials out side MD and including necessary scaffoldings complete all as specified and directed.
M&L for 10mm thick ready mix plaster , on fair faces of brick work or concrete surfacesl; finished even and smooth including necessary scaffolding complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on wall complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed.
M&L for preparation of old surfaces of walls including washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat oil bound distemper with roller complete all as specified and directed.
M & L for complete removal of existing treatment by scrapping / washing down with water and applying two coats of oil bound distemper over a coat of primer, applying with roller complete all as specified and directed.
M & L white cement based Wall care putty not less than 1mm thick on wall/ceiling new or old surfaces of any description finished even and smooth complete all as specified and directed.
M&L 5 mm thick ready mix plaster over concrete surfaces of ceiling surfaces finished even and smooth including necessary scaffolding complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling etc complete all as specified and directed
M & L for 20 mm (15+5mm) thick ready mix plaster using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified and directed. Note : Water proofing compound shall be measured & paid seperately.
M&L for for preparation of new plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and including necessary scaffolding complete all as specified and as directed.
M&L for preparation of old surfaces of walls/slab projections by brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots including washing down,with water and applying one coat of 100% antifungal acrylic emulsion paint in approved shade etc all as per manufacturers instructions including necessary scaffoldings etc,complete all as specified and as directed.
M & L for preparation of old decorated plastered or unplastered surfaces of walls, cornices etc by washing down, brooming down or steel wire brushing, scrapping down, smoke soot, moulds, moss effloresence salts and trading oil and greasy spots complete removal and applying one coat of cement base paint complete all as specified and directed .
M & L for cutting out cracks (not exc 5mm) to V-section in existing wall/chajjas and cleaning out and filling up with crack seal including necessary scaffoldings complete all as specified and as directed.
M&L for Removal of plant growth by injection with chemical glyphospate solution ( 4 % conceneration ) @ 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm. The area shall then be sprayed with solution 25ml glyphosphate ( 4% concent) dulited with 1 ltr of water. All roots / plants shall be removed completely and making good the distrubed surface and painted with cement base or acrylic paint complete all as specified and directed.
M&L for preparation of old/new decorated wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint. complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement or lime mortar including all quoints, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks, built in CM 1 : 6, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed.
M&L chipping, removing carefully concrete surface by low impact hamer/bracker without damaging the structure incl preparation of old surfaces of reinforcement bars as per manufacturer's instruction and disposal of debris out side MOD land and applying anticorrosive protective coating for steel reinforcement surfaces and allpying epoxy bond coat of approved make over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new mortar, by brush application and building up the profile of structural members by using polymer modified mortar of approved make, upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
Removing loose concrete carefully by low impact hammer bracker or manually by chisel and hammer machanisuem including necessary scaffolding and removal of debris out of MD land Complete all as specified and directed. REHABILITATION WORK ITEMS 19 TO 22 Note : 1. Rehabilitation works is to be carried out by the authorised rep / applicator of the manufacturer and will render certificate at the stages to the effect that work / methodology has been executed / adoped as per the prescribed norms. 2. The rate for rehabilitation works includes necessary scaffolding, form work, steel props, and safety works like barricade, safety net, dust net etc as per site requirement.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 40mm in thikness) with prebatched, prepacked, single component ready to use microconcrete of approved make at any level and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications complete all as specified and directed.(Note : Reinforcement only shall be measured and paid separately).
M&L for providing mild steel TMT bars in 10mm & over various structural RCC elements like column, beams and Slab etc. including cutting, bending, fixing the bars, tying with binding wires etc. complete all as specified and directed. Note: (1) Including Anchoring of reinforcement bars . (2) This item is applicable for new RCC and also for additional bars requied in the existing RCC structures in repairs.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed.
S&F 160mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to walls etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to walls etc complete all as specifed and directed.
S&F 75mm bore PVC soil waste pipe pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc including taking down of any type complete all as specifed and directed.
S&F 160mm dia PVC bend any radius with or with out access doors etc, completed as specified and directed.
S&F 110mm dia PVC bend any radius with or with out access doors etc, completed as specified and directed.
S & F 110 mm bore PVC (SWR) Branch piece, single (single Y) equal or unequal of any radius with access door complete all as specified and directed.
S & F 75 mm bore PVC (SWR) Branch piece, single (single Y) equal or unequal of any radius with access door complete all as specified and directed.
S & F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed.
S & F Bands, straps, supports, hold fasts or stays for wooden post, two or three way and securing complete conforming to Fe-290 Gde E-165 complete all as specified and directed.
Resecuring or easing & adjusting without taking down door shutter of any description exc 1.00 but n exc 2.00 Sqm each complete all as specified and directed.
Taking down door / window shutter of any description exc 1.00 but n exc 2.00 sqm each and refixing in the same opening after easing, adjusting & renewal of unserviceable screws etc complete all as specified and directed.
Supply & fixing in repairs aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed
M&L in repairs PVC valveless, syphonic action type, 10 ltrs cap flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32mm dia and fixed in repairs complete all as specified and directed.
M&L connector PVC 450mm long complete all as specified and directed.
Dismantling floor, hearth or wall tiling any description and thickness including cement mortar bedding (but not backing) and removing rubbish off the premises.
M&L PCC 30mm thick type B0, 1 : 2 : 4 (12.5mm graded aggregate) in sub flooring complete all as specified and directed..
M&L non-skid coloured joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry over and including provision of bedding layer 15 mm thick in CM 1 : 4 complete all as specified and directed.
M&L glazed ceramic jointless coloured tiles in vertical surface 350x250x7mm / 450 x 350 x 7mm set and jointed in neat cement slurry over and including provision of bedding layer 10mm thick in CM 1 : 3 complete all as specified and directed.
M&L vitrified ceramic tiles 10mm thick light shade (Square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors over and including provision of cement screed bedding layer 20 mm thick in CM 1 : 4 etc set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
Taking up or down steel tubing 15mm bore of pipe and connections including cleaning for refixing etc as required complete all as specified and directed..
All as per item no.43 above but 20mm bore of pipe complete all as specified and directed.
M&L tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia complete all as specified and directed.
All as per item no.45 above but 20mm bore dia complete all as specified and directed.
S&F PVC cabinet mirror in repairs of size 600X450 mm complete all as specfied and directed.
Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified and directed.
M&L for cement concrete type C-1, 1:3:6 (20 mm graded aggregate) 75 mm thick as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
S & F for Forming construction Joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
Demolition of Reincorced concrete in chajjas and similar suspended, slab facia drop etc work complete all as specified and directed.
Flush cutting of Rcc chajjas, fins with reinforcement up to 150 mm depth by norms of Rcc mechanical cutting machine, complete all as specified and directed.
S&F premoulded FRP Chajjas with 2 to 2.5 mm FRP thickness on both sides with manglore clay type finished with 150 mm drop on front, sides and 60 mm collar on back side including necessary fixtures complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq. M each complete all as specified and directed.
S&F extruded Powder coated aluminium section as in window, ventilation,door (powder coated 50 micron in blackcolour) with movable, openable or fixed type shutter or any pattern as directed, aluminumsection medium weight of series B or size as directed by the Engr in charge cut to size , jointed toghter including rubber beading and all necessary fitting complete all as specfied and directed. Note :- (i) Only aluminum sections measured and paid in this item. (ii) Rate quoted by the contractor shall deemed to be inclusive of all neecssary fittings and fixture such as roller,handle,locks etc (iii) Glass pane and XPM jali measured and paid under supply only rate.
S & F aluminium grill conforming to DG- 102 of approved make, (10mm X 5.2mm) thick of approved design or equivalent as approved by Accepting Officer and fixing with and including 'F/U' channel not less than 1.5mm thick and fixed in repairs complete all as specified and directed.
Supply only sheet glass 4.8 mm thick in glazing with rubber and aluminium beading/packing with rubber gasket complete as specified and directed.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Taking down Chowkhats or frames with shutter (without taking off shutter from frames) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed.
S&F II nd class Hard Wood plain, solid straight chawkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, completed as specified and directed.
S&F MS flat iron as in hold fast and similar work as specified Gde Fe 290 Gde E-165 completed as specified and directed.
M&L PCC Block for hold fast and similar work etc 1 : 2 : 4 type B-1(using 20mm graded stone aggregate) complete all as specified and directed.
M&L Plain framed,35 mm thick panelled shutter with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm II nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred bends for securing glass etc. size of members of shutters as specified in SSR, Part I, section -8, clause 8.20(a) supplied and fixed to chowkhats.
S&F stainless steel butt hinges 100mm size complete all as specified and directed.
S & F 150mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed.
S&F150 mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
M&L 300mm long Aluminium alloy, anodised, sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixed complete all as specified and directed..
S&F 300 mm Push spring type stainless steel floor door stopper complete all as specified and directed.
M&L for preparation of over wood based surfaes of any description, not otherwise described oer 10cm width or girth one coat of pink primer and application of two coats of synthetic enamel paint on new wooden surfaces completed as specified and directed.
Supply & Fixing in repairs sheet glass 4.8 mm thick in glazing n exc 0.5 sqm each with rubber and aluminium beading/packing with rubber gasket complete as specified and directed.
Supply only pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed.
M&L stop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions in repairs complete all as specified and directed.
All as per item No.76 above but angle cock Chromium plated 15mm bore dia complete all as specified and directed.
M&L bib tap brass 15mm bore dia chromium plated long shank fancy type with curtch or butterfly handle , screwed down, screwed for iron pipes complete in repairs complete all as specified and directed.
S&F health faucet (Hand wash for EWC) first quality including CP bracket to hold the faucet with CP pipe of suitable length in wall all as per manufacture instructions and as directed.
M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 1000 ltrs capacity complete all as specified and directed..
M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 2000 ltrs capacity complete all as specified and directed..
M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete .25mm dia complete all as specified and directed.
M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia complete all as specified and directed
M&L for post constn, antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete as specified and directed.
M&L for providing and injecting chemical chloropyrphos emulsion conforming to IS-3244(with 20% EC) for post construction antitermite treatment along external wall below concrete or masonry apron @ 2.25 litre per running meter including drilling and plugging note complete all as specified and directed.
M&L for post construction antitermite treatment at point of contact of wood work by chemical emulsion ( in oil or kerosene based solution) @ 0.5 ltr/hole by drilling 6mm dia hole at a downward angle of 45 degree at 150 mm centre to cetre and sealing the same complete all as specified and directed.
S & F Tubular towel rail / curtain rod 20mm dia Aluminium anodised & fixed in repairs complete all as specified and directed.
S&F in repairs Aluminium brackets for tubular towel rail 20mm dia complete all as specified and directed.
Dismantling of boarding ,any description and in any position complete all as specified and directed
M&L for 18/19mm thick prelaminated particle board with teak wood beading, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws for kitchen cabinets or shelves, drawers of any shape and size having particians(vertical or horizontal) including fixing with screws and fixing of all necessary fittings like hinges of any type, Handles rollers or shelves, magnets. etc. to timber complete all as specified and directed.
M&L for 2nd class hardwood moulding n. exc 6 sqcm as in cornices, picture rails and the like such as in prelaminated particle board complete all as specified and directed.
Supply only stainless steel roller of size 25mm x 12mm, 505mm length suitable for baskets complete all as specified and directed.
Supply only Magnet of suitable size fixed for cabin leafs, drawers etc, complete all as specified and directed.
M&L, 18 to 20 mm thick M/C and M/C polished Kota stone slab in single piece in jambs and in double piece in cills on vertical surfaces and over 15mm thick cement mortar 1:3 backing coat jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing and necessary edge moulding before fixing of kota stone complete all as specified and directed.
M&L for providing 4 mm thick APP modified memberane in repairs over (Inaccessible) RCC roof with the following specifiations :- (a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :- (i) Membrane weight >3.6 Kg/Sqm . (ii) Net wooven polyster weight >160 gm/Sqm (iii) Softening point of membrane > 150o C (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane. (d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane
M & L for Machine cut Kot stone slab flooring 20-25mm thick over and including provision of screed bed 20mm thick in CM 1 : 6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & mirror polishing complete all as specified and directed.
M&L for providing stages wise waterproofing treatment to sunken portion surface area bottom & sides of toilets as under. Stage 2: Providing 15 mm thick plaster in CM 1:3 mixed with integral water proofing chemical of approved make in the proportion /quantity all as per manufactures instructions. Stage 3 : Primer - Mix Primer of approved make with water in ratio 1:1 @ 250 gms/sqm and apply the primer on the plaster surfaces Stage 4 : Application of 1 st coat of water proofing compound of approved make without dilution with water@1kg/sqm by brush all as per manufactures instructions. Stage 5: Laying 50 GSM fyber glass cloth over the 1st coat while the coated surface is still tacky Stage 6: After 6 to 7 hours interval apply second coat i.e final coat of water proofing compound of approved make without dilution with water by brush as per manufactures instructions.@1kg /Sqm Stage 7: Providing 10mm thick protective plaster in CM 1:3 mixed with water proofing compound of approved make @ 250ml/50kg cement all as manufactures instructions.
M&L WC connector 110 mm PVC SWR for WC complete all as specified and directed.
Supply only PVC connector 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
M&L in repairs Stainless steel floor trap, plain with grating removeable & refixable type including jointing with solvent cement 75mm dia of outlet complete all as specified and directed.
S&F in repairs 40mm bore high density polythene pipes (HDPE) of pressure rating 6 Kg / cm2 fixed complete to walls, ceiling or in floors etc complete all as specified and directed.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white with Plastic water closet seat, black, closed pattern withflat bottom, and cover and mild steel chromiumplated or aluminised hinging device all as specified and directed.
Resecuring or easing, greasing & adjusting without taking down door shutter or rolling shutter of nay description exc 2.00 Sqm each including replacement of unserviceable lever, lock, handle, covering etc as required for smooth operation complete all as specified and directed.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc complete all as specified and directed.
Taking down carefully copper/alumunium Sub main wiring from the position and removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc complete all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs etc complete all as specified and directed.
Taking down of existing ceiling fans, opening / dismantling of fan & fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement of burnt Copper Winding, capacitors, bearings, bushes, canpoy, condensor, clamp, safety pin, rubber bush and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with two coats of synthetic enamel paint after prepartion of surfaces,complete all as specified and directed. (For Single Phase Induction Type Motor Ceiling Fans)
Taking down of existing ceiling fans, opening / dismantling of fan & fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement Stator Copper Winding, bearings,and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep ,complete all as specified and directed. (For BLDC Ceiling Fans)
Supply and Fixing in Replcement Of BLDC 5 star Ceiling fan Printed Circuit Board(PCB) with Suitable existing make only Complete all as specified and directed by the Engr-in-Charge.
Supply Only Of BLDC 5 star Ceiling fan Remote(Including 02 Batteries) with Suitable existing make only Complete all as specified and directed by the Engr-in-Charge.
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn Completely in and including PVC casing caping fixed on the surfaces of Walls/RCC slab/ ceiling/columns/beams etc with all accessories, fittings, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed
All as per item No 111 above but for one 3 pin switch socket 5 Amp single pole one way on same board with other switches including continuous 1.5sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed.
All as per item No 111 herein above but for one 3 pin switch socket 5 Amp independent complete all as specified and directed.
All as per item No111 above but for 3 pin switch socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
All as per item No 111 above but for 3 pin switch socket outlet 15 Amp independent with cable 4.0 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core partly concealed in wall through Existing/Laying new PVC conduit(as directed by Engr-in-charge) and concealed accessories and partly surface on ceiling, beams and cloumns through casing caping and accessories of size 20/25mm complete with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light/Fan point controlled by one switch complete all as specified and directed.
All as per item No.116 above but for one 3 pin socket 5 Amp single point pole one way on same board with other switches including continuous 1.5 sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed by the Engr-in-Charge.
All as per item No 116 above but for one 3 pin socket 5 Amp independent complete all as specified and directed
All as per item No.116 above but for 3 pin switch socket outlet 15 Amp independent with cable 4.0 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
Supply and Fixing in Replcement Of Old unserviceble Electric insulated backelite/Acrylic White Cover sheet 3 mm thick with existing switch board size 28x30 cm or 30x28 cm as per existing size including independend socket boards along with cutting and make holes for Mounting switches/sockets piano type Complete all as specified and directed by the Engr-in-Charge.(Note : The rate quoted by the contractor shall also include charges for Cutting sheet and Replacement of old sheet with new suitable size screws and Reconnecting of switches /socket connections)
Supply and fixing ceiling fan electronic regulator 100 watt step type 230V, all as specified and directed.
Supply and fix in repair switch piano type 5 Amp single pole one way complete all as specified and directed.
Supply and fix in replacement of switch modular type 6 amp single pole one way 230 V all as specified and directed.
Supply and fix in replacement of switch modular type 16 amp single pole one way 230 V all as specified and directed.
Supply and fix in replacement of socket outlet multi purpose 5 pin 6 Amp modular type complete all as specified and directed.
Supply and fix in replacement of socket outlet multipurpose 3 pin 16 Amp and 3 pin 6 amp modular type 2 in 1 complete all as specified and directed.
Supply and fixing in replacement of ceiling fan regulator modular type 120 watts all as specified and directed.
Supply and fix in replacement of ceiling rose surface backelite three terminal complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 8 Module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 6 Module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 3/4 Module complete all as specified and directed.
Supply & fixing modular Plastic Surface PVC box 6/8 Module complete all as specified and directed.
Supply & fixing modular Plastic Surface PVC box 3/4 Module complete all as specified and directed.
Supply & fixing in Replacement of U/S Ceiling fan/Exhaust fan capacitor 2.5 micro farad capacity complete all as specified and directed.
Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and ocket complete with one single pole MCB MCB 20 Amp complete all as specified.
Supply and fix in repairs Triple pole and earth enclosure with a three pin and earth plug and ocket complete with one Triple pole MCB MCB 40-63 Amp complete all as specified.
Supply and fix in repairs 25 Amp a two pin and earth Aluminium Die cast metal clad plug top for Geysers and AC'S complete all as specified and Directed by the Engr-in-Charge.
Supply and fix in repairs 16 Amps rated Three pin PVC plug top for Geysers and AC'S complete all as specified and Directed by the Engr-in-Charge.
M&L in repairs for sub main wiring two run of size 2.5 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 2.5 sqmm PVC insulated copper conductor earth wire in PVC casing caping of suitable size (three run of 2.5 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring all as specified and directed.
M&L in repairs for sub main wiring two run of size 4 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 4.0 sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (three run of 4 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed.
M&L in repairs for sub main wiring two run of size 6 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 6 sqmm PVC insulated copper conductor earth wire in PVC casing caping of suitable size (three run of 6 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring all as specified and directed.
M&L in repairs for sub main wiring Four run of size 10 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 10 sqmm PVC insulated copper conductor earth wire in PVC casing caping of suitable size (Five run of 10 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring all as specified and directed.
Supply and fixing in replacement To surface mounting slim/Box type LED flat panel 2' x 2' LEDs 36/40 watts Inlcuding Replacement of Unserviceable LED Drivers and Multistrip LEDs Suitable to Fitted on False ceiling by cutting to complete all as specified and directed.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 20 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 10 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
S & F in replacement of U/S Halogen light fitting with Die cast aluminium painted black housing with mounting cradle along with protractor having inside 500 W halogen lamp surronded by High purity anodized aluminium reflector with bright hammered ,Toughened glass permanently fixed to housing using silicon sealant finish including holder connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in replacement of U/S 500W Glass Halogen lamp complete all as specified and directed.
S & F in replacement of u/s LED Glass Halogen lamp 500 Watt complete all as specified and directed.
Supply and fixing in replacement of LED lamp with acrylic cover 15-18 watt Pin or Threaded type complete all as specified and difected.
Supply and fixing round/Square shape 15 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing round/Square shape 18 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix MCCB 100 Amps 3 Pole, with breaking capacity 25 KA along with spreader termnals replacement of old unservceable one complete all as specified and directed.
Supply and fix MCCB 63 Amps 3 Pole, with breaking capacity 16 KA along with spreader termnals replacement of old unservceable one complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted MCB DB TPN 415 Volts 4 way double door Horizontal type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 8 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 12 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 8 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 4 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed.
Supply and fix MCB TPN 240 volts 40 to 100 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SPN 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fixing in replacement of Exhaust fan Metal Lower(Flip cover Outside) Suitable for Exhaust fan 300 mm size and 450 mm size over the out side surface of Kitchen/Bathroom wall on building Complete all as specified and directed. Note : The rate quoted by the contractor shall arrange the ladder for fixing the lower at any height of floor the building with necessary manpower
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 25 x 4 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe Connection with the existing earth chamber etc. with 25x4 mm size galvanised iron strip complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 53,915.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
M/s Mukesh Engineers
KRISHNA ENGINEERS
mp construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .