| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L1 | Accepted-AOC Awarded as first lowest bidder (L1) | |
| 2 | L2₹40.6 L+₹1.7 L (4.44%)Rejected-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L2 | Rejected-AOC Awarded as second lowest bidder (L2) | |
| 3 | L3₹43.6 L+₹4.7 L (12.0%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L3 | Rejected-AOC Awarded as third lowest bidder (L3) | |
| 4 | L4₹44.2 L+₹5.3 L (13.7%)Rejected-AOC | L4 | Rejected-AOC Awarded as forth lowest bidder (L4) | |
| 5 | L5₹44.4 L+₹5.5 L (14.0%)Rejected-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L5 | Rejected-AOC Awarded as fifth lowest bidder (L5) |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
1 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR AND MAINT OF CHILLED CENTRAL PACKAGE SPLIT WINDOW TYPE AC AT HEMRL UNDER GERD PASHAN PUNE
2021_MES_413240_2
GERD/PSN/TOKEN/31 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹80,000
Yes
28 Apr 2021
4 Mar 2021
3 Apr 2021
5 Mar 2021
1 Apr 2021
15 Mar 2021
5 Mar 2021 - 13 Mar 2021
60 days
Amount
Material and labour for disconnecting and dismantling of compressor of central Air conditioning plant by putting plates to the suction and discharge valve by taking down the crank shaft and re installed in the position with correct alignment after cleaning, overhauling testing and commissioning of Compressor including removing unserviceable /damaged internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reeds, Cylinder liners, Loading / unloading system compressor spring, Washers nut bolts, Gaskets, shaft seal, unserviceable flanges sockets "O" ring, cutting, metalising, grinding, balancing the crank shaft if required and reassembling the compressor including changing the compressor oil, leak testing with Nitrogen, repairing leakages and charging F-22 gas, testing/ commisioning complete of Make "ACCEL / Accelsabro / Kirloskar" Model No. SMC-2-65, SMC-4-65, SMC-6-65, SMC 8-65" including fixing of unserviceable parts as ordered here in after in respective items of Schedule “A” as supply only including supply and fixing minor required items charging of compressor oil and refrigerant completely including transportation to work shop and back and performance testing for 08 hours to achieve desired performance parameter complete all as specified and directed by Engineer-in-charge.
Material and labour for disconnecting and dismantling of compressor of central Air conditioning plant by putting plates to the suction and discharge valve by taking down the crank shaft and re installed in the position with correct alignment after cleaning, overhauling testing and commissioning of Compressor including removing unserviceable /damaged internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reeds, Cylinder liners, Loading / unloading system compressor spring,Washers nut bolts,Gaskets,shaft seal, unserviceable flanges sockets "O" ring, cutting, metalising, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with Nitrogen, repairing leakages and charging F-22 gas, testing / commisioning complete of Make "ACCEL / Accelsabro / Kirloskar" Model No. SMC-6-100, SMC-8- 100 and AC 470" including fixing of unserviceable parts as ordered here in after in respective items of Schedule “A” as supply only and fixing minor required items charging of compressor oil and refrigerant completely including transportation to work shop and back and performance testing for 08 hours to achieve desired performance parameter complete all as specified and directed by Engineer-in-charge. unserviceable parts as ordered here in after in respective items of Schedule “A” as supply only including supply and fixing minor required items, charging of compressor oil N-68 shetal and refrigerant completely including transportation to work shop and back and testing all as per item 01 above complete all as specifed and directed by Engr-in-charge. Notes for item No 1.0 & 2.0 here-in-before:- (i) Refrigerant Gas (R-22) and compressor oil required shall be paid separately as supply only under respective item of Sch (A). (ii) The cost of labour charges for fixing of spare parts in compressor charging of oil and gas including minor spare parts if any required at the time of repair is deemed to be included in the quoted rate of the item. (Iii) Major Spares for overhauling of compressor will be measured and paid separately under item no 3-4. (iv) Cost of additional minor spares,accessories,fasteners deemed assential for make machine fully serviceable is deemed to be included in quoted rate
Supply only following spare part of compressor superior quality (Make : Voltas / Accel / Kirloskar type SMC 2-65 / 4-65/6-65 and 8- 65 model) complete all as specified and directed :- (a) Piston assembly aluminium alloy complete(Piston withpiston pin, piston rings and scraper rings complete).
(b) Piston pin & Piston rings.
(c) Suction and discharge valve with valve retaining plates and ring plates, spring guides, valve bolts and Nuts complete.
(d) Main bush bearing with bushing collar for crank shaft as per existing.
(e) Gasket Set (Packing kit) for compressor including top cover, side cover, end cover and bearing cover complete.
(f) Connecting rod alumunium alloy with small end and big end bearings complete.
(g) Rocker including cylinder, springs, spring holder, retainers, spring guide complete.
(h) Suction strainer as per existing specifications.
(j) Neoprene 'O' ring set for compression with aluminium washer complete kit.
(k) Oil strainer and oil filter complete
(l) Guide for Discharge valve.
(m) Oil pump assembly complete as per existing specifications.
(n) Suction and discharge reed with 'O' ring complete.
(o) Cylinder liner cast steel as per existing specifications.
(p) Safety valve assembly complete.
Supply only following spare of superior quality for compressor of SMC-8-100 / SMC 6-100 complete all as specified and dirceted :- (a) Cylinder liner cast steel as per existing specifications.
(b) Connecting rod alumunium alloy with small end and big end bearings complete.
(c) Piston assembly aluminium alloy complete(Piston withpiston pin, piston rings and scraper rings complete)
(d) Piston pin & piston ring.
(e) Oil Strainers and oil filters complete
(f) Rocker including rocker arm including unloading cylinder, rocker springs, rocker spring holder / retainer with and including, Spring guide complete.
(g) Guide for discharge valve.
(h) Discharge valve assembly complete.
(j) Neoprene 'O' ring set compression rings and O rings complete set with aluminium washer complete kit complete.
(k) Safety valve assembly complete.
(l) Suction valve ring plate with reeds /Discharge valve ring plate with reeds complete.
(m) Solenoid Valve 1/4", 220 volts complete.
(n) Main bush bearing for crank shaft as per existing specifications complete.
(o) Suction strainer as per existing existing specifications complete.
(p) Filter Cartridge for compressor complete.
(q) Oil pump assembly as per existing existing specifications complete.
Supply and fix in repairs wornout crankcase heater of compressor of Make : Accel Type -SMC-2-65, SMC-4-65, SMC-6-65, SMC-8-100, AC-470 or as per existing specifications complete all as specified and directed.
Supply and fix in repairs shaft seal assembly for vaious models of compressors of Make : Accel / Kirloskar complete all as specified and directed.
Material and labour for descaling of shell and tube type water cooled condenser of capacity 15TR to 30 TR with and including MS shell and intergral copper tubes with safety valve with cleaning agent including nitrogen flushing / descaling compound and through cleaning with descaling nylon brush with rod and circulating by descaling pump including repalcement of gasket sets, nuts and bolts and leakage testing after descaling / cleaning of condenser unit complete all as specified and directed.
Material and labour for descaling of shell and tube type water cooled condenser of capacity 31TR to 75TR with MS shell and intergral copper tubes with safety valve with cleaning agent including nitrogen flushing / descaling compound and through cleaning with descaling nylon brush with rod and circulating by descaling pump including repalcement of gasket set , nuts and bolts and leakage testing after descaling / cleaning of condenser unit complete all as specified and directed.
Material and labour for chippinging of insuation and opening of end plate for cleaning and washout of foreign material and scale and deposits of chiller unit direct expansion , shell and tube type15TR to 30TR TR capacity with cleaning agent including nitrogen flushing and through cleaning with brush with rod suitable size and dia and recirculating and complete cleaning nylon brush including replacement of gasket sets, nuts , bolts and EPDM insulation on both ends, faces matching to existing chilar insulation complete all as specified and directed.
Material and labour for chippinging of insuation and opening of end plate for cleaning and washout of foreign material and scale and deposits of chiller unit direct expansion , shell and tube type 31TR to 75TR capacity with cleaning agent including nitrogen flushing and through cleaning with brush with rod suitable size and dia and recirculating and complete cleaning nylon brush including replacement of gasket sets, nuts , bolts and EPDM insulation on both ends, faces matching to existing chilar insulation complete all as specified and directed.
Material and labour for disconnecting electrical connections motor located at the top of cooling tower, keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting/dismentaling all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of T&P for servicing of cooling tower, 15 TR to 60 TR capacity including comprising of following complete all as specified and directed :- (i) Cleaning /scrapping of inner and outer surface of FRP basin, repair of damaged portion if any incuding FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts, joining all parts of basin complete, (ii) servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and making the necessary alignment with motor, (iii) replacement of bearings of suitable capacity if any after necessory work including greasing and replacement of nuts, bolts and preventing leakage if any by means of suitable adhesive etc complete all as specified and directed, (iv) taking out PVC fills blocks, cleaning and refixing as per existing location and channel direction, (v) servicing of spray header and sprinkler assembly complete & (vi) repair of water strainer complete.
All as per item No 40.0 here-in-before but for 60TR to 150TR capacity. Note for item Nos 40 & 41 here in before : The cost of labour charges for replacement of major spares and cleaning of PVC Fills and refixing including minor spare parts required for complete operation at the time of repair is deemed to be included in the quoted rates. Major spares required for repalcements will be measured and paid for separately as 'supply only' under respective items of Sch 'A' here-in-after.
Supply only following spare part for cooling tower of capacity 15 TR to 150 TR Make : Kool Drop / MIHIR / ADVANCE / HIMGIRI complete all as specified and directed to be replaced under item Nos 40 & 41 :- (a) PVC fill (big size) in colums of size 60cm x 30cm x 15 cm or next higher size as per existing specification and requirement.
(b) PVC fill (small size) in colums of size 60cm x 15cm x 15cm or next higher size as per existing specification and requirement.
(c) Roler bearing/Pedestal bearing for fan motor as per sample of make SKF or as per existing.
(d) Ball / Roller bearing for Sprinlkler top and Bottom Hub for 15 TR to 150 TR capacity.
(e) Sprinkler Hub top and bottom portion with PVC pipe and cap complete set for capacity 15TR to 60TR.
(f) Sprinkler Hub top and bottom portion with PVC pipe and cap complete set for capacity 61TR to 150TR.
(g) PVC nozzles and sprinkler pipe .
Supply and fixing in repairs toggle switch one way 5 Amps including control wiring and lugs if any complete all as specified and directed.
Material and labour for disconnecting electrical connections, refrigerent piping and water piping and servicing, repair and over hauling of AHU for Air handling unit of capacity 3000 Cfm to 12000 Cfm, sectionalized construction of capacity 7.5 TR to 30 TR including removing dust, dirt, foreign material deposited on cooling coil fins with suitable ditergent, cleaning / de-carbunising of pre and post air filters of shaft and reinstalled in same position with correct alignment after cleaning /repairing, removing all rust from shaft by machinery work, polishing maching to existing and rebalancing of shaft including servicing and testing of blower drum assembly for proper functioning and balancing including replacement of defective spares including supply and fixing minor spares required to achive noise free operation including testing, commissioning complete for achieving desired performance complete all as specified and directed.
Material and labour for disconnecting electrical connections, refrigerent piping and water piping and servicing, repair and over hauling of AHU for Air handling unit of capacity 12001 Cfm to 13000 Cfm, sectionalized construction of capacity 31 TR to 60 TR including removing dust, dirt, foreign material deposited on cooling coil fins with suitable ditergent, cleaning / de-carbunising of pre and post air filters of shaft and reinstalled in same position with correct alignment after cleaning /repairing, removing all rust from shaft by machinery work, polishing maching to existing and rebalancing of shaft including servicing and testing of blower drum assembly for proper functioning and balancing including replacement of defective spares including supply and fixing minor spares required to achive noise free operation including testing, commissioning complete for achieving desired performance complete all as specified and directed. NOTE FOR ITEM NOs 50&51:- Spares required to be replaced for serving of AHU shall be measured and paid for separately as 'supply only' under respective item of BOQ here-in-after.
Supply only roller bearing / ball / taper bearing for blower motor as per sample of make SKF or as per existing make for AHU of capacity 7.5 TR to 60 TR (Make : Kool Drop / AIRCON / ZECO) complete all as specified and directed.
Supply only roller bearing / ball / pedestal bearing for blower shaft as per sample of make SKF or as per existing make for AHU of capacity 7.5 TR to 60 TR (Make : Kool Drop / AIRCON / ZECO) complete all as specified and directed.
Material and labour for servicing and cleaning of cooling coil 4 rows to 6 rows deep of capacity 7.5 TR to 60 TR with cleaning agent and removing the oil and dust from fins and cooper tubes/ pipes complete and checking of copper tubing for leakage maching/ repairing /brazing of leakaged tubes complete including sealing of joints complete all as specified and directed.
Material and labour for repair of spray water type dehudification system of Air Handling Units complete by pressurized cleaning of spray water header with nozzle complete including replacement of following unservicible spare parts complete all as specified and directed :- (a) Spray water nozzle, (b) Flexible PVC pipe Heavy duty of 20 mm dia complete from water tank to dehumidifier pump, (c) GI pipe medium grade of 20mm dia with fittings and (d) Rewinding & repairing dehumidifier pump 1 Phase, 240V 0.5 HP to 1 HP capacity - 01 No.
Material and labour for disconnecting electrical and water connection of hot water generator of capacity 10 KW TR to 50 KW of 15 TR to 60 TR AC plant and sealing ends carefully, dismentling and taking out complete generator, dismentling terminal heater plate, rods replacement of gasket set and reassembling, testing and commisssioning the hot water generator after repair including to and from transportation from site to workshop and back all as directed including fixing of unserviceable parts as ordered here in after in respective items of Schedule “A” as 'supply only' including supply and fixing minor required items and testing for 08 hours to achieve desired conditionand temperature to the entire satisfaction of Engr-in-charge complete all as specified and directed NOTE FOR ITEM NOs 55 & 56 here in before :- Spares required to be replaced shall be measured and paid for separately as 'supply only' under respective item of BOQ here-in-after
Supply only spare part for hot water generator of capacity 10KW TR to 50KW of Make as per existing make availale at site complete all as specified and directed :- (a) Heater Rod 3KW, suitable for 3 PH, 415V AC supply as per sample.
(b) Heater Rod 9KW, suitable for 3 PH, 415V AC supply as per sample.
(c) Terminal heater plate suitalble for a and b Nos ofheater rods including control circuit.
(d) Thermostate and control switch ON/OFF assembly control auto and manual paramerters.
Material and labour for repairs to condenser / chiller pump including dismantling of Pump and segregating its parts for repairs and maintenance, replacement of spare parts requiredto be replaced including grinding, polishing, bend removing etc including spray painting with two coats of synthetic enamel paint and reassembling of pump after repair work & testing complete complete all as specified and directed for the following capacity pump:- Notes : (i) The cost of minor spares, accessories, fasteners if any required to make the pump fully serviceable, cost of labour charges for replacement of unserviceable spare parts is deemed to be included in the quoted rate. (ii) Spare parts required to be replaced will be measured and paid separately as 'supply only' under relevent item of BOQ. (a) Pump 3 HP to 7.5 HP.
(b) Pump above 7.5 HP to 15 HP.
Supply only following srare parts of pump set complete all as specified and directed :- (a) Shaft bearing 3 to 5 HP pump set as per existing.
(b) Shaft sleeve 3 to 5 HP pump set.
(c) Impeller 3 to 5 HP pump set.
(d) Impeller Key 3 to 5 HP pump set.
(e) Shaft bearing 5 to 7.5 HP pump set
(f) Shaft sleeve 5 to 7.5 HP pump set
(g) Impeller of 5 to 7.5 HP pumpset
(h) Impeller Key 5 to 7.5 HP pump set.
(j) Shaft bearing of pumpset above 7.5 HP up to 10 HP.
(k) Shaft bearing for 10 HP up to 15 HP pumpset .
(l) Shaft sleeve of pumpset above 7.5 HP up to 10 HP.
(m) Shaft sleeve for 10 HP up to 15 HP pumpset.
(n) Mechanical Couplings for Pumpset 3 HP up to 5 HP pumpset
(o) Mechanical Coupling for Pumpset 7.5 HP up to 15 HP pumpset .
Material and labour for disconnecting from main supply carefully squirrel cage induction motor 3 Phase, 415V AC from existing foundation and taking to workshop for servicing and necessary repair including replacement of unserviceable parts as ordered including supply and fixing minor required items like nuts, Bolts , washers, carry out Misc repairs and reassembling, testing and commisssioning the motor after repair including transportation from site to workshop and back all as specified and directed for the following capacity motor :- NOTE : (i) Cost of labour for replacement of bearigs shall be deemed to be included in qouted rate. Bearings shall be measured and paid for separately as 'suply only' in respective item of BOQ. (a) 1HP to 2 HP.
(b) 3 HP to 5 HP.
(c) 7.5 HP to 15 HP.
(d ) 16 HP to 40HP.
Supply only Ball bearing for squirral cage induction motor of capacity 1 HP to 20 HP
Supply only Ball bearing for squirral cage induction motor of capacity 25 HP to 75 HP
Material and labour for disconnecting the electrical and mechanical connection of burnt electrical motor from the site / location, transporting to and from to work shop, rewinding of electrical motor/ pump motor winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing by dismantling and removing the burnt cut copper winding wire, cleaning the slots of startor with petrol and brushes and heating the coil and remove air bubbles complete stator / roter after rewinding and reassembling all parts including reinstalling connection to original position and testing on full load complete all as specified and directed for different capacity of motor as per following :- (a) 1 HP to 2 HP.
(b) 3 to 5 HP.
(c) 7.5 HP to 15 HP.
(d ) 16 HP to 40 HP.
(e) 50 HP to 100 HP.
Material and labour for repair of liquid line globe valve any size and specification neoprane gland / "O" ring /packing /taflon packing sheet etc of various sizes complete including testing and commissioning complete all as specified and directed.
Supply and fix in repair 25 mm bore liquid refrigerant line Gun-metal, globe or gate valve, ISI marked, with iron wheel head, screwed both ends for iron pipe including necessary cutting, welding/brazing required complete all as specified and directed.
Supply and fix in repair 40 mm bore liquid refrigerant line Gun-metal, globe or gate valve, ISI marked, with iron wheel head, screwed both ends for iron pipe including necessary cutting, welding/brazing required complete all as specified and directed.
Supply and fix in repair 50 mm bore liquid refrigerant line Gun-metal, globe or gate valve, ISI marked, with iron wheel head, screwed both ends for iron pipe including necessary cutting, welding/brazing required complete all as specified and directed.
Supply and fixing in repairs 50 mm dia bore of C-1 butterfly valve ISI marked with maching double flanges , gasket, necessary hardware complete all as specified and all as directed. Make :- Audco/ Kirloskar/ Zoloto/ L&T/ Tata/ Leader.
Supply and fixing in repairs 80 mm dia bore of C-1 butterfly valve ISI marked with maching double flanges , gasket, necessary hardware complete all as specified and all as directed. Make :- Audco/ Kirloskar/ Zoloto/ L&T/ Tata/ Leader.
Supply and fix in repairs 100 mm dia bore CI Sluice valve with stainless steel spindle PN-I.6 confirming to ISI marked including jointing material nut bolts packing complete all as specified and directed. Note : Any addition alteration required for fixing of new Sluice valve is deemed to be included in quoted rate. Make :- Audco/ Kirloskar/ L&T/ Venus/ KSB/ Upadhyaya.
Supply and fix in repairs 80 mm dia bore CI Sluice valve with stainless steel spindle PN-I.6 confirming to ISI marked including jointing material nut bolts packing complete all as specified and directed. Note : Any addition alteration required for fixing of new Sluice valve is deemed to be included in quoted rate. Make :- Audco/ Kirloskar/ L&T/ Venus/ KSB/ Upadhyaya.
Supply and fix in repairs 65 mm dia bore CI Sluice valve with stainless steel spindle PN-I.6 confirming to ISI marked including jointing material nut bolts packing complete all as specified and directed. Note : Any addition alteration required for fixing of new Sluice valve is deemed to be included in quoted rate. Make :- Audco/ Kirloskar/ L&T/ Venus/ KSB/ Upadhyaya.
Supply and fix in repairs of thermal expansion valve suitable for 50 TR to 90 TR chilled water Central type AC plant system all as per sample, including brazing at both ends all as required complete all as specified and directed.
Supply and fix in repairs of thermal expansion valve suitable for 15 TR to 45 TR chilled water Central type AC plant system all as per sample, including brazing at both ends all as required complete all as specified and directed.
Material and labour for locating and identifing gas and oil leakage and removing the leakage by repairing, brazing, flaring of tubings of central type AC Plant of capacity upto and including 28TR including leakage testing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and directed. Note : Nitrogen gas and refrigerant will be measured and paid separately as 'supply only' under respective item of BOQ.
Material and labour for locating and identifing gas and oil leakage and removing the leakage by repairing, brazing, flaring of tubings of central type AC Plant of capacity 31TR to 90TR including leakage testing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and directed. Note : Nitrogen gas and refrigerant will be measured and paid separately as 'supply only' under respective item of BOQ.
Material and labour for checking and testing of electrical control panel of AC Plant for interlock panel wiring, detecting the fault / defects including replacement of minor burnt wires, lugs, terminals and making panel in workable condition including testing complete all as specified and directed.
Material and labour for taking down of old broken GI ducting and providing GI sheet 22 guage with TDF flanged rectangular/square duct made of "L" shaped hollow profile including all accessories such as corners, cleats, carriage bolts, gaskets and appropriate sealent on longitudinal joints complete including GI sheet cover 28 guage all as directed and connecting / matching to the existing ducting system, including necessary brackets / supports of suitable size MS angle and applying painting to supports with two coats of synthetic enameled paint over a coat of primer including preparation os steel surfaces complete all as specified and directed. Note : Insulation will be measured and paid for separaterly.
Material and labour in repairs for ducting insulation made of fiber glass wool roll of density 24 kg/cum of thickness of insulation 50 mm including jointing with propper sealing against any leakges and applying rubber based adhesive CPRX compound, sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide to make the insulation leak proof, securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 metre complete all as specified and directed.
Material and labour for spray painting to air conditioning plant equipments refrigerant / water suction / discharge / liquid piping of any specification with synthetic enameled paint of best quality including prepration of steel surface including concealed fitments e.g., condenser , chillar, valves etc as per IS colour Code of Cental Air Cinditioning plants including writing MES / SM No complete all as specified and directed.
Supply and fix in repair wet and dry bulb thermometer at A/C plant room complete all as specified and directed.
Material and labour for dismentling and taking out completely Air dryer / chemical dehumidifier of MAKE BRY AIRCON of capaciity 200 CFM, 42 TR air handling units 3 Ph 415V AC for following repairs, overhauling, servicing, balancing, assembling, reinstalling in same position with correct alignment and comissioning, testing for proper functioning complete for achieving desired performance complete all as specified and directed comprising of followigs repairs :- (i) cleaning of hot air /fresh air ducting to the humidifier filters, (ii) removing dust, dirt, foreign material deposited on cooling coil fins with suitable ditergent, (iii) cleaning / de-carbunising of pre and post air filters, (iv) remove all rust from shaft/ dampers by machinery work and rebalancing of shaft and dampers, (v) pressurized cleaning of spray water header/ nozzle, (vi) checking and testing of panel wiring, control wiring, relays, controllers, detecting the fault/defects including replacement of minor burnt wires, lugs, terminal, etc., (vii) removing drying sagregatting refilling of silca gel pads/container required to meet desired RH and temperture control complete.
Material and labour for removal of existing perished insulated materials from conditioned air ducts and provision of duct insulation 19mm thick in non AC area except AHU with elastomeric Nitrile rubber class 1 with insulation density between 40kg/cum to 55 kg/cum and withstand maximum surface temperature of 85 deg.C and minimum of 50 Deg.C duly cladding with non metallic double layer laminated aluminium coated with UV protection 230 microns thickness complete all as specified and as directed comprising of following :- (a) Cleaning of duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage, (b) The adhesive shall be rubber based,solvent based contract adhesive free from benzune with maximum tear strength resistance, (c) Covering material shall be insulatd with 30 mm to 50 mm overlaps on all horizontal and logitudinal joints, (d) Tthe joints shall be secured with plasitc rivets in the overlap area. All joints and overlaps must be finished with manufacturer recommended PSA Tape, mm in Non AC area except AHU.
Material and labour for removal of existing perished insulated materials from conditioned air ducts and provision of duct insulation thickness 25 mm for AHU room insulation with elastomeric Nitrile rubber class 1 with insulation density between 40kg/cum to 55 kg/cum and withstand maximum surface temperature of 85 deg.C and minimum of 50 Deg.C duly cladding with non metallic double layer laminated aluminium coated with UV protection 230 microns thickness complete all as specified and as directed comprising of following :- (a) Cleaning of duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage, (b) The adhesive shall be rubber based,solvent based contract adhesive free from benzune with maximum tear strength resistance, (c) Covering material shall be insulatd with 30 mm to 50 mm overlaps on all horizontal and logitudinal joints, (d) Tthe joints shall be secured with plasitc rivets in the overlap area. All joints and overlaps must be finished with manufacturer recommended PSA Tape, mm in Non AC area except AHU.
Taking down old perished insulated materials from chilled water pipe and Material and labour for chilled water pipe insulation of thickness 9 mm for pipe below 50 mm dia bore with closed cell elastomeric Nitrile rubber class 1 thermal conductivity not less than 20deg.C insulation density between 40kg/cum to 55 kg/cum and duly cladding with non metallic 3 layered laminated of aluminium UV protection and a polymer backing complete all as specified and as directed for the following :- (a) Cleaning the pipe surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage, (b) The adhesive shall be used for bonding the seams securely together including butt and longitudinal joints, fittings and coverings must be closed with adhesive, (c) The adhesive shall be specially formulated fot the pipe insulation application and supplied by the insulatin manufacturer and have excellent bonding to porous and non porous surfaces, (d) the joints shall be secured with plasitc rivets in the overlap area. All joints and overlaps must be finished with manufacturer recommended PSA Tape,
Taking down old perished insulated materials from chilled water pipe and Material and labour for chilled water pipe insulation of thickness 19 mm for pipe above 50 mm dia bore with closed cell elastomeric Nitrile rubber class 1 thermal conductivity not less than 20deg.C insulation density between 40kg/cum to 55 kg/cum and duly cladding with non metallic 3 layered laminated of aluminium UV protection and a polymer backing complete all as specified and as directed for the following :- (a) Cleaning the pipe surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage, (b) The adhesive shall be used for bonding the seams securely together including butt and longitudinal joints, fittings and coverings must be closed with adhesive, (c) The adhesive shall be specially formulated fot the pipe insulation application and supplied by the insulatin manufacturer and have excellent bonding to porous and non porous surfaces, (d) the joints shall be secured with plasitc rivets in the overlap area. All joints and overlaps must be finished with manufacturer recommended PSA Tape,
Supply only R-22 Refrigerant gas in returnable company sealed cylinder of 61kg each with manufacturer's test certificate complete all as specified and directed. Make : Mafron/Feron or equivalant as approved by GE. Note : (i) Hire charges of cylinder shall be deemed to be included in quoated rates. (ii) Charging of refrigerant Gas shall be measured and paid under respective item of BOQ or whereever required.
Supply only Nitrogen Gas at required pressure for leak testing of central AC plant filled in standard size cylinder at required pressure complete all as specified and directed.
Supply and charging of compressor oil N-68 after flushing out old oil of compressor and testing & commissioning complete all as specified and directed.
Supply and fixing in repairs "V" belt of size C-120 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size C-116 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-61 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-70 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-71 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-72 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-74 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-75 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-76 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-80 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-81 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-83 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-85 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-86 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-89 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-90 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-97 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-102 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-110 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size B-132 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-32 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-45 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-47 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-60 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-69 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-71 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs "V" belt of size A-85 for power transmission of existing specification / cross section complete all as specified and directed.
Supply and fixing in repairs pressure diffrential control cutout for central type A/C plant and testing complete all as specified and directed of following size :-Engineer-in-Charge. (a) Oil pressure cutout MP-55
(b) High pressure cutout MP-1
(c) Low pressure cutout MP-5
Supply, installation, testing & commissioning in repairs water cooled scroll type compressor 15 TR of semihermatically sealed scroll motor with internal overload protector, compressor mounted on existing base including connecting with existing refrigerant pipe line , integral refrirant piping and wiring accessories as required complete all as specified and directed including comprising of following :- Auto /Manual single phasing protection, Compressor restart protection, 10 sec - time delay between system, Short circuit protection, 5 degree C anti freeze protection, Display on micro control indicating compressor on crank case heater on / off, Entering/ leving water temperature' Scroll chiller unit shall be suitable for 415 + 15% 50 C/S 3 phase AC supply, and Refrigerant used shall be R-22 or suitable for existing system as mentioned in specifications of manufacturer. Make :- Voltas/ Blue Star/ Tecumseh.
Supply and fixing in repairs pilot solenoid valve assembly for central type AC plant as per sample complete all as specified and directed.
Supply and fix in repairs water pressure gauge 4" dia with tube to match and stop cock for range 0 to 150 PSI complete all as specified and directed.
Supply and fix in repairs pressure gauge 4" dia suitable for refrigerent R-22 and compressor oil including 1/4" copper pipe end to U shape with flair nuts/adopter at both ends,range of gauge -30 to 300 PSI complete all as specified and directed.
Supply and fix in repairs thermometer to condenser/chiller, inlet or outlet water pipes including addition alteration to pipe line for fixing thermometer Range 0-100 degree F / degree centigrade complete all as specified and directed.
Supply and fixing in repairs water presuure gauge 0 to 7 kg / cm2 any type Make Febig or as per existing complete all as specified and directed.
Supply and fix in repairs pressure relief valve of condenser 3/8" BSP threaded suitable for 300 PSI complete all as specified and directed.
Supply and fix in repairs worn out HRC fuses (Cylindrical / DIN type / Bolted) conforming IS 13703 Part - II with high breaking capacity suitable for existing holders complete all as specified and directed for the following capacities :- (a) 66 Amps to 160 Amps.
(b) 200 Amps to 400 Amps.
Supply and fix in repairs single phase preventer in electric panel board at central type AC plants all as per direction of Eng-in-charge complete all as specified and directed.
Supply and fix in repairs 3 pole power contactor , coil voltage 230 Volts/415 Volts for following capacity motors complete all as specified and directed:- (a) 12 Amps to 25Amps
(b) 50 Amps to 90 Amps.
(c) 150 Amps to 225Amps.
Supply, fabrication, erection, testing and commissioning in repairs 100 mm dia bore of MS pipe C class conforming to IS : 1239/3589 heavy class including all fittings like anchor fasteners, pipe supporting frame structure, couplings, bends, elbows, tees, thrust block complete all as specified and directed.
Supply, fabrication, erection, testing and commissioning in repairs 80 mm dia bore of MS pipe C class conforming to IS : 1239/3589 heavy class including all fittings like anchor fasteners, pipe supporting frame structure, couplings, bends, elbows, tees, thrust block complete all as specified and directed.
Supply and laying in repairs 100 mm dia bore medium grade galvanised steel water tubes ISI marked with screwed socket joint together with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs and unions etc laid in trenches including testing complete all as specified and directed.
Supply and laying in repairs 80 mm dia bore medium grade galvanised steel water tubes ISI marked with screwed socket joint together with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs and unions etc laid in trenches including testing complete all as specified and directed.
Supply and laying in repairs 50 mm dia bore medium grade galvanised steel water tubes ISI marked with screwed socket joint together with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs and unions etc laid in trenches including testing complete all as specified and directed.
Material and labour for servicing of window type /Split type AC 1.5 TR/2.0 TR at site, cleaning evaporator, condensing coil by using carbon tetra chloride, combing the evaporator, condensor fins,greasing all the moveable parts of fan motor, testing the wiring of whole AC, checking all parts, cleaning the air filter and replacing the unserviceable spare parts, including cleaning the tray and refixing the back AC in position by providing proper packing for better effects, testing and commissioning of AC including marking of SM/MES No. complete all as specified and directed.
Material and labour for disconnecting of water cooler of capacity 40 litre / 80 litre / Hr from electric and water connection at site and servicing the water cooler by cleaning condensor by using carbon tetra chloride combing the evaporator condensor fins, cleaning of water storage tanks greasing all the moveable parts of fan motor, testing the wiring and checking all parts and replacing the unserviceable spare parts including cleaning the tray and fixing back water cooler in position, testing and commissioning of water cooler marking of SM/MES No. complete all as specified and directed by Engr-in-charge.
Supply and fixing in repais compressor for water cooler of capacity 40 litres/80 litres and soldring to unit including replacement of filter including testing and comissioning including disconnecting and taking out old unserviceable sealed unit compressor from water cooler and soldering to unit, complete all as specified and directed by Engr-in-Charge. Make : Blue Star/ Voltas/ Hitachi/ Usha.
Material and labour for labour for recharging of refrigrant gas R-134 and compressor oil for water cooler including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc; and testing system on full load capacity complete all as specified and as directed.
Material and labour in repairs for rewiring of condenser fan motor of water cooler 1 / 32 HP with supper enemalled copper wire of appropriate gauge of Make Devi Dyal or equivalant as approved by GE including insuation, refixing and testing at location complete all as specified and as directed.
Material and labour in repairs for relay with over load protection for water cooler any capacity complete all as specified and directed. Make : Sriram or as per existing as approved by GE.
Material and labour in repairs for thermostat for water cooler all as specified and directed. Make : ANNAPURNA or as per existing as approved by GE.
Material and labour in repairs for running capacitor 36 mfd, 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for running capacitor 10 mfd, 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for starting capacitor 80-100 mfd 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for starting capacitor 40-60 mfd 230 volts complete all as specified and directed. Make : EPCOS or as per existing as approved by GE.
Material and labour in repairs for sealed unit compressor for refrigerator of capacity 186 to 310 litre and testing complete all as specified and directed. Make : Tecumseh/ Voltas/ Hitachi/ Blue Star/ Daikain.
Material and labour for recharging gas R-134 and compressor oil for refrigerator including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc, testing complete on full load capacity complete all as specified and directed.
Material and labour in repairs relay starting cum over load protection for refrigerator complete all as specified and directed by Engr-in-Charge. Make : ANNAPURNA / INDFOSS / RANUTROL
Material and labour in repairs thermostat switch suitable for 165 litre / 286 litre / 310 litre refrigerator model S-1051 complete all as specified and directed by Engr-in-Charge. Make : ANNAPURNA / INDFOSS / RANUTROL.
Material and labour in repairs for sealed unit compressor from window type air conditioner capacity 1.5 Ton including pressure testing complete all as specified and directed. Make :- Hitachi/ Blue Star/ Voltas/ Tecumseh.
Material and labour for charging refrigerant gas R-22 or suitable for system and compressor oil for window type AC 1.5 ton including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc; and testing complete system on full load capacity all as specified and as directed.
Material and labour in repairs for rewinding of condenser fan motor capacity 1/10 HP of window type AC with supper enameled copper wire of same gauge Make Devi Dyal or equivalant as approved by GE including refixing and testing of fan motor complete all as specified and directed.
Material and labour for disconnecting and taking out old unserviceable sealed unit compressor from split air conditioner of cap 1.5 TR/2.0 TR and fixing new compressor pressure testing complete all as specified and directed by Engineer-in-Charge. Make :- Hitachi/ Blue Star/ Voltas/ Tecumseh.
Material and labour for rewinding of condenser fan motor of split type AC with supper enameled, copper wire of same gauge of Make Devi Dyal or equivalant as approved by GE including refixing and testing complete all as specified and directed by Engr-in Charge.
Material and labour for charging of refrigerant gas R-22 and compressor oil in split type AC 1.5 /2.0 TR capacity including vaccumising the complete system, detection of leakage, brazing etc, testing on full load all as specified and directed by Engineer-in-Charge.
Material and labour in repairs for PCB of 1.5 Ton / 2.0 Ton capacity window /split type AC with remote control kit ,connecting up and testing on load complete all as specified and directed.
Supply and fixing in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps from wall surface and fixing (AC Socket) for Window/Split AC all as directed and specified by Engr-in-Charge.
Supply only refrigerant Gas R-22, complete all as specified and directed.
KESARI AND SONS
shakti engineering and electrical works
PAMS ENTERPRISES
M/s Vijay Airconditioning Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .