Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | Rejected-Technical NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | - | Rejected-Technical Document not found ok due to not enlisted in appropriase category c (ii) |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
28 Mar 2024, 6:00 pmClosed
GE AF TECH AREA AGRA
GE AF TECH AREA AGRA
COMPREHENSIVE MAINT AND REPAIR TO LIFTS GANTRY AND CRANES INSTALLED UNDER GE AF TECH AREA AGRA
2024_MES_644812_1
8200-1576/E8
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
330 days
GE AF TECH AREA AGRA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TECH AREA AGRA
₹30,000
Yes
24 Sept 2024
1 Mar 2024
30 Mar 2024
1 Mar 2024
28 Mar 2024
9 Mar 2024
1 Mar 2024 - 4 Mar 2024
Amount
Comprehensive maintenance of 10 passenger (680 kg.) electrically operated passenger lift service to ground + 5 floors with fully automatic door with V3F drivn system at SRE building etc complete all as specified and directed. Make of lift Johnson
Comprehensive maintenance of 08 passenger(544 kg.) electrically operated passenger lift service to ground + 2 floors with fully automatic door with V3F drivn system at 251 SU building etc complete all as specified and directed. Make of lift Johnson
Comprehensive maintenance of 08 passenger(544 kg.) electrically operated passenger lift service to ground + 4 floors with fully automatic door with V3F drivn system at ATC building etc complete all as specified and directed. Make of lift Johnson Note for item 1,2&3:- (i)The entire work mentioned at item No. 1, 2 & 3 including comprehensive, preventive and periodical maintenance of lifts/ elevators shall be got executed through OEM such as M/S Johnson Lifts Pvt. Ltd. The contractor shall submit the hard copy of MOU for AMC with lifts manufacuturer to the deptt before commencement of workfor 11 months on stamp paper. (ii) Contractor shall deploy trained trademen directly employed and supervised by OEM or reputed firm. The trademen shall be quailifed to keep equipment properly and take care to maintain the elevators equipment in proper and safe operating condition. (iii) Contractor/OEM shall regularly and systematically examine, adjust, lubricate as required all elevator parts such as gear, motor, controller, V3F drive, lift cabin and all connected parts of lift and make them functional. (iv) Contractor shall attend the break downs immeadiately on receipt of complaints verbal or written by User/JE/Engr-in-charge. (v) In case of emergency, contracor shall attend to the break down within 12 hours, faiiling which a panel recovery of Rs 2000/- will be made from contractors dues. (vi) Contractor shall provide all safety equipments to his tradesmen for their safety while working on lifts/cranes and with all electrical equipments without any extra cost to department. (vii) Contractor/OEM rep shall periodically equalize the tension on the hoisting to maintain an adequate factor of safety. (viii) Contractor shall examine periodically all safety devices and make monthly, quarterly, half yearly and yearly safety tests as per OEM recommendedation. Monthly report to be submitted the concern GE office.
(ix) Any number of complains attend shall deemed to be quoted rates. (x) The detailed lift mechnic of the firm shall report to the JE concerned at the lift complaint cell for receiving the compliants at round the clock daily including sunday and holiday. (xi) Cost of minor spare parts/ rountine material reuired for above mentioned maintenace is deemed to be included in the quoted rate. No additional cost of spares is admissible for the above maintenance. Decision of the accepting officer shall be final & binding regarding minor spares/routine material. (xii) The following routine materials required for above mentioned maintenance is deemed to be included in the qouted rate, decision of the accepting officer shall be final. (a) PCB contactors, transformers,chock and other controller component (b) VVVF drive (c) Rollers, Bearings, salenoids coils (d) Relays in controller, Push button, indiactors, door contacts (e) Push buttons, Limit switches (f) Brake shoe, Liners (g) Contacts, magnetic switches, magnets (h) Door motor& Drive, encoder (j) Car door safety device, infrared screen (k) Governor, Interlocks on hoist way doors, Motors, Ropes, Travelling cable, Repairing of ARD unit.
S&F car cabin fan suitable for lift LH6092 LD2518 and LE3171 as per existing shape size and capacity complete all as specified and directed.
M&L for servicing thoroughly of EOT cranes of 2 ton capacity with replacement of unserviceable parts/items after taking down complete including load testing for satisfactorily working of cranes complete all as specified and directed by Engr-in-Charge . Note: (i) Major Parts/items which shall be replaced shall be measured and paid seperately in relevant item harein after.
M&L for servicing thoroughly of EOT cranes of 10 ton capacity with replacement of unserviceable parts/items after taking down complete including load testing for satisfactorily working of cranes complete all as specified and directed by Engr-in-Charge . Note: (i) Major parts/items which shall be replaced shall be measured and paid seperately in relevant item harein after
M&L for servicing thoroughly of HOT/TLTS cranes of 1 ton capacity with replacement of unserviceable parts/items after taking down complete including load testing for satisfactorily working of cranes complete all as specified and directed by Engr-in-Charge . Note: (i) Major Parts/items which shall be replaced shall be measured and paid seperately in relevant item harein after.
M&L checking of over head cranes any size,type , capacity and location for functioning of motors, unusual noise and nut bolt washers etc including testing for smooth functioning and inform Engr in Charge for repair if required complete all as directed by Engr-in-charge. Note: Contractor shall provide all safety equipments to his tradesmen for their safety while working on cranes and with all electrical equipments without any extra cost to the department.
S&F in replacement limit switch of suitable size of make as per existing for 2 ton capacity crane
S&F in replacement limit switch of suitable size of make as per existing for 10 ton capacity crane
S&F in replacement contactor of 40 Amps 3 pole of make as per existing.
S&F in replacement dog with spring of make as per existing
S&F in replacement bearing 2310 & 2305 with pedastal in transmission shaft of make as per existing
S&F in replacement Ratchet gear as per existing
S&F in replacement operation switch of make as per existing.
S&F in replacement emergency switch of make as per existing.
S&F in replacement gear oil for gear box of crane with suitable grade complete all as specified and directed.
Supply only brake oil for gear box of crane with suitable grade complete all as specified and directed.
S&F in replacement ARD Battery (12V-18 AH) complete all as specified and directed.
S&F in replacement Charger Battery (12V-2.5 AH) complete all as specified and directed.
S&F in replacement Pit switch with box & Cover (Round Type)complete all as specified and directed.
S&F in replacement Controller cooling fan complete all as specified and directed.
S&F in replacement PVC insulated copper Cable of size 3 core 1 sqmm complete all as specified and directed.
S&F in replacement Push Button KA131 BRAILLE UP-Orange complete all as specified and directed.
S&F in replacement Push Button KA131 BRAILLE DN-Orange complete all as specified and directed.
S&F in replacement Emergency Lamp Board (LED) complete all as specified and directed.
S&F in replacement 12 Volt Siren complete all as specified and directed.
S&F in replacement Cross Flow fan complete all as specified and directed.
S&F in replacement PVC insulated bearing oil complete all as specified and directed.
S&F in replacement Nylon Roller U Assy complete all as specified and directed.
S&F in replacement Metal Roller V Assy complete all as specified and directed.
S&F in replacement POD latch LH complete all as specified and directed.
S&F in replacement POD latch RH complete all as specified and directed.
S&F in replacement Oil Tank Assy-10mm complete all as specified and directed.
S&F in replacement Charger Unit complete all as specified and directed.
S&F in replacement Door Slipper (POD) complete all as specified and directed.
S&F in replacement Pickle skate moving Assy complete all as specified and directed.
S&F in replacement Three way intercom complete all as specified and directed.
S&F in replacement Telephone cable 4 core complete all as specified and directed.
S&F in replacement Door Rope (C.0 700mm) complete all as specified and directed.
S&F in replacement BCD interface board with GONG driver SG 602 complete all as specified and directed.
S&F in replacement DOT matrix with Dynamic scrolling complete all as specified and directed.
S&F in replacement KDS Break realising cable -05 Mtr length complete all as specified and directed.
S&F in replacement Add ON block 3 NO+1 NC (TC) complete all as specified and directed.
S&F in replacement ADD on Block 4 N/O complete all as specified and directed.
S&F in replacement ADD ON block (2NO+2NC+Siemens) complete all as specified and directed.
S&F in replacement Door Limit switch wit 2NO+2NC-LH complete all as specified and directed.
S&F in replacement Door Limit switch wit 2NO+2NC-RH complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .