| 1 | L1₹96.7 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹1.2 Cr+₹18.4 L (19.0%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 3 | L3₹1.2 Cr+₹22.2 L (22.9%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L3 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 4 | L4₹1.3 Cr+₹32.8 L (33.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 5 | L5₹1.4 Cr+₹42.8 L (44.1%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L5 | Rejected-Finance Other than lowest tenderer hence rejected |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
12 Jan 2022, 6:00 pmClosed
CWE MAMUN
HEADQUARTERS CWE MAMUN PATHANKOT 145001
PROVN OF ENERGY EFFICIENT LIGHTING SYSTEM, PREPAID METERS, INTERNAL ELECTRIFICATION, HOT WATER AND EXTERNAL ELECTRIC SUPPLY IN MAMUN MIL STN UNDER GE NORTH MAMUN
2021_MES_493122_1
CWE/M-21/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE NORTH MAMUN
Category b ii
6 documents required · 6 mandatory
₹1,000
GE NORTH MAMUN
₹2.2 L
Yes
5 Feb 2022
10 Dec 2021
14 Jan 2022
10 Dec 2021
12 Jan 2022
31 Dec 2021
Amount
Supply, Install, Testing and commissioning of Solar cum electric Water heating System (Evacuated tube collector) based on direct transfering of heat ,thermosyphon circulation,of capacity 300 LPD suitable for bathing purpose consisting of following components all as specified and as per manufacture design:-(a) Evacuated tube collector assembly suitable for 300 LPD (b) Stainless steel hot water tank with a heat resistant protective coating and insulated with polyurethane foam with scarificial anode and electric back up with minimum 2KW element (c ) Collector stand (d) Tank stand assembly (e)Internal Piping for cold and hot water incl lagging to pipes all as specified (f) open vent pipe for pressure build up (g) Instrument (one temp guage, strainer& water meter) (h)Gate valve for cold and hot water piping of suitable size (j) complete arrangement for mounting the collector panels incl necessary plinth/foundation of suitable size complete all as specified and as directed.
Material and labour single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amp including flushing into the wall and making good the disturbed surface complete all as specified and directed.
Supply & fixing GI tubing medium grade 20 mm bore complete with all accessories such as tee,bends, short bends, nipple etc including connecting and fixed on floor/wall complete all as specified and as directed.
Supply and fixing hot water pipe 20 mm bore complete duly insulated with glass wool 25 mm thick of density 144kg/cum conforming to IS-9842 lagging to pipe all around and providing aluminium cladding 0.1mm thick on the pipe section all as specified and as directed.
Supply and Fixing brass Angle valve heavy duty cast copper alloy polished bright fancy type chromium plated(ISI Marked) conforming to IS-781 of size 20 mm bore all as specified and as directed.
Supply and Fixing brass Bib Tap heavy duty cast copper alloy polished bright fancy type chromium plated(ISI Marked) conforming to IS-781 of size 20 mm bore all as specified and as directed.
Supply and fixing rotational moulded polythylene water storage tanks ,triple layer, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 ltrs including 20mm dia ball brass with float valve complete all as specified in SSR Part - I including complete arrangement for mounting the tank on angle iron (65x65x6mm) stand of height not less than 2.0meter complete all as specified and directed.
Material & Labour for Point wiring (Surface) with 4.0 Sq. mm (nominal area) PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor IS-694 drawn through and including PVC rigid concealed conduit alongwith continuous earth wire 4.0 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to sheet metal enclosure complete all as specified and directed. Note :- Proper colour code will be used for wiring as per the electrical rule and as directed.
Supply and Install electric water heater storage type 25 Ltr capacity 5 Star rated ABS body having wall mounting arrangement incl thermostate, indicators, Air release valve, syphon assly, thermally insulated stainless steel tank of glass lined inside and heating element and mounting on wall with suitable size of anchor bolts with complete connection of water & testing and all as specified and directed.
Supply and Install electric water heater storage type 50 Ltrs capacity 5 Star rated ABS body having wall mounting arrangement incl thermostate, indicators, Air release valve, syphon assly, thermally insulated stainless steel tank of glass lined inside and heating element and mounting on wall with suitable size of anchor bolts with complete connection of water & testing and all as specified and directed.
Supply & Fixing stainless steel braided flexible connection pipe of size 15mm bore and 300mm long with GI hexagonal adopters/Nuts on both sides, ISI Marked suitable for cold and hot water complete all as specified and directed.
Supply, install, testing & commissioning of Microprocessor based single phase tamper proof with sealing option based smart prepaid energy meter with provision of conversion into post paid at the time of emergency,surface mount type and of rating 240 Volts, 50 HZ, of range 10-60 Amps, conforming to IS16444 with LCD display and various instantaneous & billing parameters with suitable range wide area network Communication suitable for outdoor suitable Range data accumulator and compatible for Prepaid online energy monitoring through remote software / data export complete all as specified and as directed.
Supply, install, testing & commissioning of Microprocessor based three phase temper proof with sealing option based smart prepaid energy meter with provision of conversion into post paid at the time of emergency,surface mount type and of rating 415 Volts, 50 HZ, of range 10-60 Amps, confirming to IS16444 with LCD display and various instantaneous & billing parameters with suitable range wide area network Communication suitable for outdoor suitable Range data accumulator and compatible for Prepaid online energy monitoring through remote software / data export complete all as specified and as directed.
Material & Labour for sub Main Wiring using 3 x 6.0 Sqmm FRLS PVC insulated unsheathed /multi stranded copper conductor cable(Phase, neutral and earth wire) drawn through and incl PVC flexible pipe of suitable size including making connection of cable with MCBs through proper size copper/brass thimbles complete all as specified and directed. Note: Two run of submain wire (phase and neutral), and one run of earth including PVC flexible conduit and accessories will be measured as one run.
Supply, install, commissioning & testing of Outdoor suitable Range accumulate Protocal and the data transfer to the existing installed Software incl hosting, GPRS charges of sim card of DCU for 2year warranty from date of completion complete all as specified and as directed. Note:- (a)The cost of pole /fixing /mounting arrangement on which the accumulator to be installed and SMPS power supply is deemed to be included in the unit quoted rates. (b) Above referred data accumulator/DCUs/Gate ways must have internal memory to store data of minimum 100 single/three phase meters data should have inbuilt battery backup of minimum six hours. (c) Bidder will provide necessary sim card/infratructure for comminication and GPRS charges for two year period.
Supplying, Fixing, Commissioning and testing of configuration of Cloud Hosted multi user web based software for automatic meter reading & generate monthly energy data with following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would also support offline meter data entry. The meter data management system would capture and provide the follwing data:
(a) 30 min instantaneous data from all the meters for instantaneous & kWh & demand (b) Monthly and quarterly data for cumulative energy and demand. (ii) Billing Module: The billing module would collect the data from the meter data management module, calculate billing determinant and make monthly energy data available to admin and end users. (iii) Occupation and vacation Module: The System would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (iv) Customer portal: The system would include a customer portal for the resident/ occupant to log in and view their own energy / billing data & generate online recharge coupon for meter recharge. (v) Energy Accounting Module: The system would include features of energy accounting. the system would be able to account for total energy block wise. (vi) Communication module: The system should provide conmmunication of energy data and bills via app, print, email, etc methods (vii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process. (viii) Excel Export : The system would support export of metering and billing data in excel format (ix) Training: 15 days training would be provided to MES staff to operate the Module. Make : HPL/ L&T /Secure
Supply, installation and testing of computer PC with Core i5 processor second generation, 8 GB RAM, Hard disk 500 GB, 1-CD/DVD combo drive RW type 4-USB port, 1-serial port 9 Pin D type, TFT (17") monitor with licensed operating system (Window 2007)/2008) and UPS system with 1000 VA maint free battery and connecting cable pair etc. including installation of necessary softwares for operating system complete all as specified and directed.
Supply and Fixing laser jet printer with single function black & white with USB connection with printing speed of min 40 pages per minute with 512MB RAM complete all as specified and directed.
Supply, installation, commissioning and testing of dedicated Software creation for the project including tariff , kwh slab and all the futuristic smart meters requirement. one time cost and can configure N number of meters using the same software. Software updating, improvements, additional new requirements includes in the software completea all as specified and directed.
Supply & Fixing surface mounted Decorative,uplight light fitting including for 9 W LED lamp and with decorative diffuser and mounting clips and lamp holder , wall mounting arrangment and all as specified and directed.
Supply & Fixing LED batten light fitting, 20W, square batten , 6500K, 2000 Lumen , 4ft length comprising of extruded channel in aluminium housing with frosted extruded ribbed diffuser to get glare free, smooth light distribution & integrated electronic driver 230 V etc. incl PVC square or round block complete with all accessories and making connection from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
Design, supply, erecting, installing, testing and commissioning of solar PV plant with cumulative capacity of 10 KW with and including on grid connection and fixing accessories, fasteners, nuts, bolts, of stainless steel -304 Grade, complete with and including following all as per specified and directed by GE. (a) Solar Module of size as per manufacturer. (b) IEC/MNRE approved Mono-crystalline type module. (c) Module wattage not less than 450Wp. (d) Technical specification shall be approved before placing order. (e) Module Efficiency not less than 20.7%, each (f) Module weight as per manufacturer recommendation. (g) The make of solar panel shall be indigenous & MNRE approved. Certificate for the same along with technical specification shall be produced before placing order.
(h) Contractor is advised to visit the site before quoting rates. Note:- The linear performance warranty for 25 Years with 3% for first year degradation and 0.55% from year 2 to 25, certification IEC61215Ed2, IEC61730-1, IEC61730-2. and condition prevailing at Mamun (Punjab) comprising sub components/ sub system and meeting the technical specifications as given in Particular Specifications here-in-after and as listed below, complete all as specified and directed
Design, supply, fixing support structure of MS hot dipped galvanised (80microns) including PCC foundation for civil works (excavation, grouting PCC etc.) and fixing the mounting arrangement suitable for 10 Kw solar module on ground for solar tree/parking shed to withstand minimum horizontal wind speed at 170Km/Hr, the mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum speed without sacrificing the output from solar PV panels. Nuts, bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere & weather prevailing in area. All fasteners shall be of stainless steel of grade SS316. Two Nos of anti theft fasteners of stainless steel on two diagonally opposite corners of each modules shall be provided, complete all as specified and directed..
Design, supply, erecting, installing, testing and commissioning of solar PV plant with cumulative capacity of 25 KW with and including on grid connection and fixing accessories, fasteners, nuts, bolts, of stainless steel -304 Grade, complete with and including following all as per specified and directed by GE. (a) Solar Module of size as per manufacturer. (b) IEC/MNRE approved Mono-crystalline type module. (c) Module wattage not less than 450Wp. (d) Technical specification shall be approved before placing order. (e) Module Efficiency not less than 20.7%, each (f) Module weight as per manufacturer recommendation. (g) The make of solar panel shall be indigenous & MNRE approved. Certificate for the same along with technical specification shall be produced before placing order.
(h) Support structure of MS hot dipped galvanised (80microns) including PCC foundation for civil works (excavation, cutting, grouting PCC etc.) and fixing the mounting arrangement suitable for PV solar mudules on roof top & in PCC blocks & to withstand minimum horizontal wind speed at 170Km/Hr, the mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum speed without sacrificing the output from solar PV panels. Nuts, bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere & weather prevailing in area. All fasteners shall be of stainless steel of grade SS316. Two Nos of anti theft fasteners of stainless steel on two diagonally opposite corners of each modules shall be provided, complete all as specified and directed.. (j) Contractor is advised to visit the site before quoting rates. Note:- The linear performance warranty for 25 Years with 3% for first year degradation and 0.55% from year 2 to 25, certification IEC61215Ed2, IEC61730-1, IEC61730-2. and condition prevailing at Mamun (Punjab) comprising sub components/ sub system and meeting the technical specifications as given in Particular Specifications here-in-after and as listed below, complete all as specified and directed
Supply, fixing,testing and commisioning Solar Grid Tied String Inverter 10 Kw complete all as specified for above solar module and all as specified and directed.
Supply, fixing,testing and commisioning Solar Grid Tied String Inverter 25 Kw complete all as specified for above solar module and all as specified and directed.
Supply, fixing, testing and commisioning Array Junction Box (DCDB) with fuse, MCB and surge protection device suitable for 10 Kw solar modules and invertor complete all as directed and directed.
Supply, fixing, testing and commisioning Array Junction Box (DCDB) with fuse, MCB and surge protection device suitable for 25 Kw solar modules and invertor complete all as directed and directed.
Supply, fixing, testing and commisioning ACDB (AC Distribution Board) Panel with MCB for incoming and outgoing, multi function energy meter and surge protection device suitable for 10 Kw solar modules and invertor complete all as directed and directed.
Supply, fixing, testing and commisioning ACDB (AC Distribution Board) Panel with MCB for incoming and outgoing, multi function energy meter and surge protection device suitable for 25 Kw solar modules and invertor complete all as directed and directed.
Supply, fixing, testing and commisioning Solar DC tin coated Copper Cable 4mm² single core, 1800V DC and including suitable size heavy duty in PVC Conduit/ tray and fixing with clamps, lugs etc. complete all as specified and directed.
Supply, fixing, testing and commisioning MC4 Connector Complete all as specified and directed.
Supply,Laying,Connecting and testing cable PVC insulated electric cable 1100 volts AC with stranded copper conductor of size 6 Sqmm 4 core laid in suitable size PVC conduit/ Channel tray complete all as specified and as directed.
Supply,Laying,Connecting and testing cable PVC insulated electric cable 1100 volts AC with stranded copper conductor of size 25 Sqmm 4 core laid in suitable size PVC conduit/ Channel tray complete all as specified and as directed.
Supply and fix LT 3 Phase-4W direct connected Energy Meter 10-60 Amps, Accuracy class-1.0 with Polycarbonate meter box with hing type locking arrangement. The meter must be having LCD type display complete all as specified and directed.
Supply, installation, testing and commissioning of lightening arrestor having coverage area suitable of 10/25 KW solar system including all accessories, complete all as specified and directed.
Material & Labour for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip of 25x4mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI light grade pipe 40mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth strip & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Material & Labour for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts and washers of GI up to test point, GI light grade pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth wire & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Supply & fixing LED street light 45W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing, powder coated pressure die cast aluminimum housing, IP 65 protection, high power LED street light with heat resistent toughened glass lens including brackets made of GI pipe of suitable dia medium grade, bend to shape at an angle of 65 degree not less than 1.2mtr long with 2 Nos. of M.S clamp fabricated out of MS flat of size 50 x 6 mm on pole, including nuts, bolts, washers etc and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and as directed. Notes:- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 for 50000 burning hours 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. PCB used shall be MC PCB type 8 The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
Supply & fixing LED street light 60W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing, powder coated pressure die cast aluminimum housing, IP 65 protection, high power LED street light with heat resistent toughened glass lens including brackets made of GI pipe of suitable dia medium grade, bend to shape at an angle of 65 degree not less than 1.2mtr long with 2 Nos. of M.S clamp fabricated out of MS flat of size 50 x 6 mm on pole, including nuts, bolts, washers etc and making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and as directed. Notes:- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 for 50000 burning hours 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. PCB used shall be MC PCB type 8 The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
Supply & Fixing flood light 120Watt operating voltage 140-270V , epoxy powder coated die cast aluminium housing, operating temparature -10º C to +45º C, Average life: 50000Hrs, , high efficiency long life LED module mounted on MC PCB, lumens efficacy of >120Lm/W, PC lens with toughned glass, independent potted IP67 electronic LED driver, short circuit protection, Over voltage protection, surge voltage protection upto 10KV with built in SPD, CCT (Colout correlated temperature of fixture shall be 5700K+/-300K including necessary mounting arrangement with suitable size of angle iron, M.S Clamps, nuts, bolts, washers etc and making electrical connections with pvc insulated sheathed 3 core 1.5 sqmm copper conductor from flood light to junction box complete all as specified and as directed.
Material and labour for errection of steel tubular pole 9mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including paintng with 2 coats of aluminium paint and 30cm strip painting in alternative green & white colour strips of 30cm height upto 1.5 mtr above from the coping complete and writting of pole No. with black paint all as specified and directed .
Supply,Laying,Connecting and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core laid in trenches/on wall/floor complete all as specified and directed
All as per Srl item No 42 Above but of size 10Sqmm, 4Core.
All as per Srl item No 42 Above but of size 16Sqmm, 4Core.
All as per Srl item No 42 above but for size 35 Sqmm X 3.5 core.
Supply & Fixing Street light panel, Pole mounted outdoor type cubical panel suitable for maximum load of 6KW, 440 Volts ,3 phase, 4 wire, 50 cycles per second comprising of Incoming MCB TPN , 415 V, 40 Amp -01 , Contactor TP ,415 V of rating 32 Amps - 01, Digital Timer 24 Hr - 01 No , Toggle Switch - 01 No including necessary mounting arrangement with suitable size MS clamps, nuts, bolts and washers complete all as specified and directed.
Supply & Fixing in replacement of GI tubing, light grade 40 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe on Pole/wall, nuts, bolts washers shall be deemed to be included in the quoted rates)
All as mentioned in item No 49 here in above but 50 mm bore
Supply & Fixing junction box water proof outdoor type made out of 2mm thick CRCA sheet of external dimensions 250 x 250 x 105 mm single door type hinged with locking arrangement front operated with one number MCB 06 Amps capacity for housing 3 phase and neutral busbar, cable glands and connecting the incoming/outgoing cables including necessary mounting arrangement with suitable size MS clamps, nuts, bolts and washers complete all as specified and directed.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as mentioned in item No 55 here in above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Material & Labour of brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
Material & Labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles, foundation and making good to disturbed surface of road /floor complete all as specified.
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for structure foundation including necessary form work and finished the surface complete all as specified and directed.
JCC ENGINEERS PRIVATE LIMITED
Vijay Kumar Contractor and Engineers
KULBHUSHAN AGGARWAL
SATISH AND CO
Standard engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .