| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.4 L+₹1.2 L (6.34%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹22.5 L+₹4.3 L (23.7%)Rejected-Finance B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹23.6 L+₹5.3 L (29.3%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹28.0 L+₹9.8 L (53.8%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Garrison Engineer Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR / MAINTENANCE OF LT FEEDER PILLAR BOX, POWER FEEDER PANEL AND ALLIED WORKS AT GE DRONACHAL
2023_MES_597502_1
8771/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bhopal
Class-D, Category b (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
Garrison Engineer Dronachal
₹60,000
Yes
25 Jul 2023
22 May 2023
21 Jun 2023
22 May 2023
19 Jun 2023
6 Jun 2023
23 May 2023 - 2 Jun 2023
Amount
Supply, installed, test and commissioning of automatic power factor control panel 150 KVAR, having 12 Banks, panel fabricated with 3.15mm thick CRCA sheet with angle iron frame of 40 x 40 x 6mm, duly painted with two coats of synthetic enamel paint over a coat of red oxide with following:-
(i) Aluminium bus- bar 400 Amps,supported with suitable size Porcelain insulators , suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set (ii) MCCB, TPN, 36 KA, 320A adjustable type suitable for capacitor bank-1No iii)APFC Relay with Auto mode -1No. iv) Capacitor MPP-H , 3 Phase, 415Volts, 50HZ 150KVAR ie ( 25x5+10x1+5x2 +3x1+2x1=150KVAR) V) MCB with contactor for Capacitor switching vi) Bank ON/OFF indication lamps vii) Cooling fan ,SP, 230 Volts.-1Nos / As required. Make shall be L&T / Mehear/ EE / CG/ Neptune.
Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , Panel shall be grouted in PCC foundation complete all as specified and directed with following accessories:-
Excavation in trenches in soft/loose of any type soil not exceeding 1.5m deep and not exceeding 1.5 m wide and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested , complete all as specified and directed at site.
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 Cm deep over the cable complete all as specified and directed.
Supply laying bricks old size sub class B bricks common burnt bldg bricks laid in trenches for cable protection complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.3mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point complete all as specified and directed or indicated including testing on completion. NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above groung level.
M&L cutting PCC/floor/road and taking out cable and making good, with material as per existing after laying of pipe for cable protection including Cement concrete work in pavement/ hard-standing of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or lessall as specified and directed size of trench not more than 0.30 x 0.30 cm complete all as specified and directed.
S&F in replacement of GI Pipe medium grade on wall/floor for cable protection with fixing arrangement size 50mm dia complete all as specified and directed.
Taking out old unserviceable LT under ground cable of any size and rating complete all as specified and directed.
Supply and Laying XLPE heavy duty armoured electric under ground cable aluminum conductor 1100 volts grade in trenches/on pole through sleeves etc for the following size complete all as specified and directed.
Cross sectional area 70 Sqm 3.5 Core.
Cross sectional area 50 Sqm 3.5 Core.
Supply and fixing earth continuity conductor or main earthing lead 32 x 6 mm GI strip laid in pipe/ fixed to poles or any other indicated situation including jointing by using GI nuts, bolts, washer and saddle in addition to welding complete and all as specified and directed.
M&L for outdoor/indoor LT panel board/Capacitor Panels/feeder pillar boxes with welding of front/Back side covers ,necessary hinges, locking system with 300mm long MS sliding door bolt 16mm dia, rubber gasket of appropriate size including proper fixing with nut bolts etc with minor spare parts and spray painting with one coat of synethetic enamel paint outer & innner side with two coat of lime wash on plinth of panel board including connected accessories in any size complete all as specified and directed by Engineer-in-charge.
Supply and replace MCCB ,4 pole, 50 Hz capacity (thermal adjustable type) complete all as specified and directed for following capacity
400 Amps with 36 KA rupturing capacity
250 Amps with 36KA rupturing capacity
200 Amps with 36 KA rupturing capacity
160 Amps with 36 KA rupturing capacity
100 Amps with 16 KA rupturing capacity
Supply and replace MCCB ,3 pole, 50 Hz capacity 36 KA rupturing capacity (thermal adjustable type) complete all as specified and directed for following capacity
Trimming/Cuting of bushes and grass of Substations/MES Installations and surrounding of Panel board feeder piller boxes at various location and dumping/staging 50 mtr from existing point complete all as specified and directed.
Testing of cpacitor and taking out old unserviceable cpacitor of any capacity form capacitor panel from substations located at Dronachal area complete all as specified and directed.
Supply and fixing long life mixed dielectric capacitors 440V, 3 phase,50Hz confirming to IEC-60831-1 & 2, with over pressure device for disconnection, having low energy losses (≤ 0.2W/KVAR), resistance to high temperature range (- 25°C + 70°C) of following KVAR (including safety cap) with minimum 1 year warranty, including all wiring work for making capacitor functional in all respect complete all as specified and directed for following KVAR :- Make : Neptune Ducati (Model :LL-M capacitor) or equivelant in Mehar/Schinder/Malday.
Taking out old unsv MCB/Multifunctional meter of any size any description and issuing under schedule of credit.
S&F in existing panel, LED multifunction meters for showing parameters, V,A,F,PF,kW,kVA,kVAR,kWh,kVARh,Runhours etc complete all as specified and directed. Make : Neptune model No : M-9 power analyser or equivalent in L&T modelA, RS485 port
S&F in existing panel of MCB TP 40A 10kA complete all as specified and directed. Make : Legrand/L&T/Havells
S&F in existing panel of MCB TP 63A 10kA complete all as specified and directed. Make : Legrand/L&T/Havells
S&F in existing panel of MCB SP 10A 10kA complete all as specified and directed. Make : Legrand/L&T/Havells
Taking out old unsv LED indication lamp on-off switch of any size any description.
S&F in existing panel LED indication lamps(Pilot lamp 22.5mm, metalic) with integral curcuit LED suitable for operating at 200 V AC SP (R/Y/B Phase) complete all as specified and directed. Make : L&T / C&S/Legrand
S&F in existing panel,LED type Start push button, flush illuminated actuator, with integral circuit LED, suitable for operating range 220V AC complete all as specified and directed. Make: L&T/C&S/Legrand
S&F in existing panel,LED type Stop push button, flush illuminated actuator, with integral circuit LED, suitable for operating range 220V AC complete all as specified and directed. Make: L&T/C&S/Legrand
S&F in existing panel, Rotary switch ( Auto-Manual) 3Phase,2KW, 25Amp capacity complete all as specified and directed. Make: L&T/C&S/Legrand
Taking out old unsv APFC relay of any size any description complete all as specified and directed.
S&F in existing panel, automatic power factor controller for automatic switching of capacitor of minimum 8 Stages, site programmable (single phase controller) complete all as specified and directed. Make : Neptune (Model :- RM series RM-8 ) or equivalent in legrand
S&F in existing panel, automatic power factor controller for automatic switching of capacitor of minimum 8 Stages, site programmable, (three phase controller) complete all as specified and directed. Make : Neptune (Model :- NAAC 3P series and code No : NAAC-3P-8) or equivalent in legrand
M & L for Calliberation of APFC Relay fixed in existing panel complete all as specified and directed.
Taking out old unsv capacitor duty contactors of any size any description complete all as specified and directed.
S&F in existing panel, capacitor duty contactor 3 pole, AC with auxililiary contacts 1NO + 1NC, 2NC including AC coil with operating voltage 220V complete with all accessories and making all connection including wiring complete all as specified and directed. suitable for following capacity :- Make : L&T/C&S/Legrand
S&F in repair power contractor rating AC1 , 80 Amps to 125 Amps, 415 Volts including fitting in exist panel with electrical connection complete all as per directed by Engr-in-charge. Make : C&S cat part No TC1-D65004 or equivalent in L&T/ Havells/ Indo Asian
S&F in repair change over switch 200 Amps 415 V, AC 23 A 4 pole type CO2- 200 confirming to IEC 60947-3 direct handle version fitting in exist panel with electrical connection comple Make: L&T/Havells/C&S/Indo Asian
Supply and replacement of Existing LT panel front/back door with 3.0mm thickness MS sheet powder coating paint including locking arrangement complete all as per directed by Engr-in-charge
Supply and replacement of LT panel busbar in repair as per existing size and PVC shrinkable sleeving with RYB colours for 4 Nos busbar complete all as per directed by Engr-in-charge.
S&F inreplacement current transformer 200/5 ratio 240 Volts complete
S&F inreplacement current transformer 400/5 ratio 240 Volts complete
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable flat 6 Sqmm complete all as specified and directed.
Repair only automatic transfer switch 250 Amps and replacement of handle and necessary spare parts including testing complete all as specified and directed.
M&L for fixing the name board fabricated with MS Sheet 2mm thick of size 1.5x3 feet and fixed with suitable GI Clamp on 2/4 pole structure including writing the detail of Sub Stn and feeder etc with blue background & white colour Letter as directed by Engr -in Charge.
Supply and installation , testing & commissioning self supporting totally enclosed factory fabricated LT bus bar panel box made out of 3.15mm thick MS sheet with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neorprene rubber gasket , epoxy powder coated including danger plate, earth strip, ventilation louvers , bottam detachable gland plate complete with suitable size zinc chromium plated nuts, bolts, and washers etc outdoor type cubicle panel board suitable for 3 phase 4 wire ,415 volt ,50 HZ and 40 mm x 40 mm x 6 mm angle iron frame, weather proof ventilated with locking arrangement incl of PCC pedestal , comprising the following & including taking down the existing Feeder pillar panel board:-
(i) Aluminium bus- bar 400Amps,supported with suitable size Porcelain standlock with suitable size brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase & neutral . - 01 Set
(ii) MCCB with microprocessor release ,4 pole, 250amps ,36 KA, 415 Volts, 50 Hz Adjustable - 01 No
ROYAL CONSTRUCTION
SAMEER ELECTRICAL SUPPLIER
PRAGATI ELECTRICALS AND ELECTRONICS
UMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .