Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.0 L+₹56,514.50 (2.41%)Rejected-Finance | L2 | Rejected-Finance Not Being lowest | |
| 3 | L3₹25.5 L+₹2.0 L (8.70%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance Not Being lowest | |
| 4 | L4₹26.4 L+₹3.0 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Not Being lowest | |
| 5 | L5₹27.7 L+₹4.3 L (18.2%)Rejected-Finance | L5 | Rejected-Finance Not Being lowest |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
23 Sept 2021, 6:00 pmClosed
GARRISON ENGINEER
Garrison Engineer (AF) Air Force Station Tambaram, Chennai - 600 046
REPAIRS AND MAINTENANCE TO AC / CGI SHEET ROOFING, WPT TO RCC SLAB , FALSE CEILING, FLOORING ,PLASTERING AND SEEPAGE TO CERTAIN BLDG IN MAIN CAMP AT AF STATION TAMBARAM
2021_MES_470855_1
GE(AF)/TAM/8452/E8
Open Tender
Civil Works
Item Rate
270 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF TAMBARAM
₹56,000
Yes
12 Oct 2021
26 Aug 2021
25 Sept 2021
27 Aug 2021
23 Sept 2021
11 Sept 2021
27 Aug 2021 - 2 Sept 2021
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as directed
Dismantling structural steel framed trusses of any type not exceeding 10m span all as directed by Engineer-in-Charge.
Dismantling plain or corrugated steel sheeting of any gauge, thickness, including nainital or similar pattern roof coverings etc all as directed by Engineer-in- charge
Dismantling asbestos cement (corrugated, semicorrugated) sheets of any description in roof coverings all as directed by Engineer-in- charge.
S&F mild steel work as in wind ties for roof including securing bolts and similar work conforming to Fe-290 Gde E-165 all as directed by Engineer-in- charge.
Fixing only mild steel work as in wind ties for roof NOTE: Serviceable flat iron obtained from dismantling shall be fixed under this item after proper cleaning
S&F Mild steel structural steel work as in roof trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe-290 (Gde E-165) all as directed by Engineer-in- charge
All as per Sl. item No 8 here-in-before but fixing only NOTE: Serviceable structural steel members obtained from dismantling shall be fixed under this item after proper cleaning including necessary welding as required at site.all as directed by Engineer-in- charge
S&F Mild steel steel work as in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240
S&F welded steel wire fabric of weight not exceeding 4 Kg per Sqm complete to wood or steel frame members all as directed by Engineer-in- charge
Dismantling boarding of any description ,fixed in any position with nails
Dismantling Single layer Mangalore pattern or similar tiles in roofing
S&F in repair 4mm thick desinger pattern AC ceiling board of size 595mmx595mm with powder coated GI frame work of grid 600mmx600mm of Make Everest fixed with 4/6mm dia GI wires hanged from roof truss with and including applying two coats of oil bound distemper
S&F in repair for powder coated galvanized snap grid frame work of size 605X605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels (gyptec) 9mm of size 600X600mm fixing with staples on snap grid by means of GI wire not less than 4mm dia hooks and rawl plugs etc C/C of Make: Gyptec/ Armstrong or equivalent complete all as specified and directed.
S&F in repair anodised aluminium snap grid standard frame work for false ceiling of grid size 605mmx605mm and including providing 12mm thick perforated particle board /tiles for insulation and accoustic purposes ,600mmx600mm in size,fixed to aluminium frame work all as specified and directed
M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified and directed
M& L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 all as specified and directed
S&F 0.80 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, in roofs, walls etc, with grade of zinc coating 275, fixed with L-type or J-type or cranked hook bolts all as specified and directed.
All as per item No 19 above but bent to curve (of any radius)
S&F in repair,2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts all as specified and directed.
S&F 0.63 mm thick plain, galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings with grade of zinc coating 275 all as specified and directed.
S&F 6 mm thick asbestos cement corrugated or semi-corrugated sheets in roofs, walls etc fixed with L-type or J-type or cranked hook bolts all as specified and directed.
All as per item No 23 above but fixing only AC sheets . NOTE : Serviceable AC sheets obtained from dismantling shall be fixed under this item after proper cleaning with new hooks and nuts all as specified and directed.
S&F Asbestos cement one piece plain angular ridge 6mm thick, fixed with L-type of J-type or cranked hook bolts all as specified and directed.
All as per item No 25 above but except AC ridge sheet NOTE : Serviceable AC sheets obtained from dismantling shall be fixed under this item after proper cleaning with new hooks and nuts.
M&L for preparing new Steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
M&L for preparing old Steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
S&F Multi rib TMT profile high tensile, 550 MP yield strength, colour coated galvalume steel sheets 0.45 mm thick as in roof covering having maximum pitch of 250mm centre to centre and minimum 28mm crest depth in length, as per site requirement fixed with self drilling/self taping screws, EDPM seal end lap 100mm and side lap one corrugation complete all as per the Manufactures instruction and as directed.
All as per item No 29 here in before but plain sheet as in ridge sheet having width 600mm all as specified and directed.
M&L for Plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in copings, bed plates,roof bands etc including weathering, slightly rounded or chamfered angles and throating as directed
M&L for mild steel plates, guesset plates and the like (plain or chequred) channels, square cut or notched forming holes, without any attchement , grade Fe -290 (Gde E 165) all as specified and as directed
S&F Mild steel screw bolts (machine made), diameter of shank 16mm to 20mm , with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 15 cm and not exceeding 22.5 cm long
M&L for removing existing water proof treatment of any description and cleaning the roof surface with wire brushes ,depositing of unsolvent materials and depositing of the same as directed to a distance not exceeding 50m and applying oil bound bitumen primer @ 0.20Kg/Sqm and providing 4mm thick APP modified water proofing membrane wighing not less than 4.0 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160gm/sqm including (minimum) 10cm side over lays and 15cm end lap torch sealed and bonded and applying a coat of blown grade hot bitumen 90/15 over and below the membrane finished with solar reflective bitumenous aluminium paint @ 0.1Kg/sqm all as specified and directed
M&L for Rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound at the rate of 3% by weight of cement on roof surfaces finished fair and even .NOTE: WPC shall be measured and paid seperately under relevant item
Supply only integral water proofing compound
M&L for Plain cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in in roof padding,kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed Note :(WPC will be measured and paid separately)
Demolition of unreinforced cement concrete in above ground floors and pavings not exc 15 cm thickness complete all as specified and directed.
Demolition of unreinforced cement concrete in pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC type B-1, 1:2:4 using 20mm graded stone aggregates 40mm thick as in roof padding complete all as specified and directed
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing unserviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for PCC type B-1, 1:2:4 using 20mm graded stone aggregates 50mm thick as in Floor finishing complete all as specified and directed
M&L screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cm 1:6 complete all as specified and directed
M&L screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cm 1:6 complete all as specified and directed
M&L 10mm thick Cement Mortar 1:4 for backing coat on walls complete all as specified and directed .
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile complete all as specified and directed.
M&L for joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles complete all as specified and directed.
M&L light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile complete all as specified and directed.
M&L light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm,as in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile complete all as specified and directed.
M&L Glazed Ceramic coloured tiles 6-7mm thick square/ rectangular) of size 300 X 200mm in vertical surfaces such as skirtings,dados etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles icomplete all as specified and directed.
M&L Glazed Ceramic coloured light coloured tiles 8-10mm thick square/ rectangular) of size 300x450mm in vertical surfaces such as skirtings,dados etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles icomplete all as specified and directed.
M&L 18 to 20mm thick pre mirror polished granite slab of approved colour ,machine cut bedded jointed and pointed with white cement slurry complete all as specified and directed.
M&L for rendering 20mm thick in CM 1:4 as in wall and slab complete all as specified and directed.
M&L for PCC 1:5:10 Type E-2 using 40mm graded stone aggregate as in sunken filling complete all as specified and directed.
M&L for PCC type B-1, 1:2:4 using 20mm graded stone aggregates 30mm thick as in base to floor complete all as specified and directed
S&F for 4mm thick APP modified membrene fixing on the wall and floors of sunken slab with torch application complete all as specified and directed.
S&F of 25mm dia GI Pipe medium grade as in spouts complete all as specified and directed.
Taking down old cement plaster including racking out joint hacking for keys and scrubbing down with water etc., on wall surfaces all as specified and directed.
M&L for 15mm thick Rendering in CM 1:4 on fair faces of brick work or concrete surfaces all as specified and directed.
M&L for 10mm thick Rendering in CM 1:6 on fair faces of brick work or concrete surfaces all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on wall complete all as specified and directed
M&L for preparation of newly plastered surfaces and applying two coats of OBD over a coat of alkali resistance primer on wall complete all as specified and directed
M&L PCC 1:4:8, Type D2 (using 20 mm graded stone aggregate), 75 mm thick, as in sub base all as specified and directed
M & L sand filling under paver blocks including watering and consolidation all as specified and directed
M&L rubber mould machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness,M-35 Grade with grey cement and pigment all as specified and directed
S&F for Chequered cement concrete tiles 30cm x 30cm x 20-25mm thick, set, jointed and pointed in neat cement slurry in floors Pattern, size and shade pointed with grey cement and pigment all as specified and directed
Mahathi Constructionss
kcs builders
prabhakaran
vrk constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .