Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.5 L+₹2.5 L (11.0%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹25.8 L+₹2.8 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹27.8 L+₹4.8 L (20.9%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹28.5 L+₹5.6 L (24.2%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
1 Jun 2020, 6:00 pmClosed
CWE (AF) Jorhat
HQ CWE (AF) Jorhat, AF Stn Jorhat, Jorhat, Assam - 785 005
83871/E8 Special Repairs to NCs (E) accommodation at AF Stn Jorhat under GE (AF) Jorhat
2020_MES_342524_1
83871/E8
Open Tender
Civil Works
Item Rate
270 days
Jorhat
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE (AF) Jorhat
₹58,000
Yes
17 Jun 2020
4 May 2020
6 Jun 2020
4 May 2020
1 Jun 2020
18 May 2020
Amount
Dismantling of plain or corrugated steel sheeting any gauge, thickness complete all as specified and directed
S&F for plain sheeting 0.80 mm thick galvanised with zinc coating 120 gms per sqm as in ridge, hips, valley gutters etc fixed with "L" or "J" type or crancked hook bolts in roof, walls etc complete all as specified and directed.
S&F for 0.63 mm thick galvanised, corrugated MS sheeting with two corrugatings side lap, fixed with "L" type or "J" type or cranked hook bolts as applicable in roof, walls etc all as specified and directed.
M&L for preparing new zinc(or galvanised) surfaces to receive painting, by coating with mordant solution including washing and cleaning etc all as specified and directed.
M&L for preparation of new decorated surfaces of roof sheet of any description (plain or corrugated) exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note : Camaflouge type : dimension exc 2.5 RM but n. exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE), for external surfaces of sheets only.
M & L for preparation of old painted surfaces of CGI roof sheet of any description (plain or corrugated) exc 10 cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note : Camaflouge type : dimension exc 2.5 RM but n. exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE), for external surfaces of sheets only.
Dismantling wall and ceiling boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards / Blankets / Slabs, any description and any thickness including cover fillets, cornices, etc., complete all as specified and as directed.
Dismantling of timber scantlings, 40 Sqcm and over in Section, in any Position, in Unframed Work, complete all as specified and as directed.
Dismantling timber fillets, rails, posts, rafters, purlings, etc., under 40 Sqcm in Section, in any position, as in unframed work, complete all as specified and as directed.
M&L for second class hardwood in scantling, wrought timber, fixed as in unframed work with nails in any position, complete all as specified and as directed.
M&L for second class hardwood plain fillets, square, rectangular or triangular in section, clean swan, fixed with nails, cross sectional area exc. 13.0 Sqcm but n. exc. 25.0 Sqcm (as in STUDS), complete all as specified and as directed.
M&L for 4 mm thick plywood (3 Nos ply) grade BWR, type BB fixed to timber frame work with screw complete all as specified.
M&L for two coats of synthetic enamel paint over a coat of pink primer including preparation of new wood base surfaces of any description, over 10cm width or girth
Taking down chowkhats or frames, exc. 1.50 Sqm but n. exc. 4.00 Sqm each with shutters (without taking off shutters from the frames), complete all as specified and as directed.
Taking down chowkhats or frames, n. exc. 1.50 sqm each with shutters (without taking off shutters from the frames), complete all as specified and as directed.
Taking down shutter, exc. 1.00 Sqm but n. exc 2.00 Sqm each, complete all as specified and as directed.
S&F for 2nd class hard wood plain solid straight chowkhats and frames wrought, frame rebated on the solid, rounded or chamfered, put together with glue pinned at joint.
S&F for glazed and skeleton shutter 35 mm thick 2nd class hard wood, divided into square, with plain chamfered or round mitred and rebated sash bar, any numbers prepared to receive glass, gauge etc edges of framing plain or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chowkhat.
S&F for factory made plain framed paneled shutter (two panel) 35 mm thick with locking rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneered on both face, size of rail and style as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated 2nd class hard wood.
S&F for Solid PVC Door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S Square tube with rebated, suppling and fixing in opening as per specification and drawing.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement suppling and fixing in the frame at site as per specification and drawing.
S&F for stainless steel wire cloth, 0.50mm nominal dia of wire and average width of aperture 1.0 mm and fixed with tinned tacks of mild steel wire strapes etc complete all as specified and as directed.
S&F in repairs stainless steel wire cloth, 0.50mm nominal dia of wire and average width of aperture 1.0 mm and fixed with tinned tacks of mild steel wire strapes, fixing etc. complete all as specified and as directed.
S&F 150mm long aluminium handles, cast type anodised
S&F for mild steel butt hinges 100mm size, medium weight, cold rolled ISI marked and fixed, complete all as specified and as directed.
S&F for 250 mm aluminums anodized sliding door bolts, ISI marked, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed
S&F for 200 mm long aluminium anodized barrel tower bolt of extruded section complete.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads
S&F for sheet glass 4 mm thick ordinary quality and glazing with oil putty or wooden bead exc 0.5 sqm in each pane complete all as specified and directed.
M & L for powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (01 No.). hinges type B-21, 100mm long (02 Nos.) suitable handle (01 No.) complete all as specified and as directed.aluminium glazed window shutter sliding type with frame including 5mm thick plain/tinted (for ventilator) glass, handle, locking arrangement, Daco grill (DG-102), complete all as specified and directed.
Disconnecting existing PVC water tank not exc 250 litres setting aside for cleaning etc. and hoisting if required reconnecting and refixing in position.
S&F for rotational moulded polyethylene (HDPE) water storage tank n. exc 250 ltr capacity (cylindrical vertical with closed top), black in colour, three layered construction, hoisted and fixed in position all specified in MES Schedule Part-I, including lowering of unserviceable water storage tank with float valve of any description, complete including taking down old unserviceable one all as specified and as directed.
S&F in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 15 mm bore.(Make : Prayag)
M&L for GI tubing 15 mm bore "medium grade " with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old unserviceable one complete all specified and directed.
M&L for GI tubing 20 mm bore "medium grade" with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old unserviceable one complete all specified and directed.
S&F in repairs 15 mm bore (ISI marked) stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions.
S&F in repairs bib tap 15mm dia, standard of PTMT, any colour, screwed for iron pipe and fixed, complete all as specified and as directed.
Demolition of brick work built in CM including all quoins, arches, pillars, etc. of any descriptions, keep serviceable bricks in safe custody for re-use as in staging of size (0.9mtr x 0.9mtr x 0.9mtr) complete all as specified and as directed
M&L for brick work with sub-class ‘B’ bricks (with old size bricks), straight or curved on plan exc. 6.0 mtr mean radius, built in CM 1:6, complete all as specified and as directed.
M&L for 150 mm thick PCC 1:2:4, type B2 (using 40mm graded crushed stone aggregate) as in sub base of flooring and hardstanding complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in floor finishing top of stagging even and smooth with using extra cement all as specified and directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surfaces, finishing the surfaces fair and even, complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces or on newly plastered wall surfaces including preparation of surfaces.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
M&L for dismantling asbestos cement (corrugated, semi corrugated etc) sheet in roof coverings all as directed.
M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates.
M&L for preparing new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint (first quality) over a coat of red oxide primer complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw as specified.
M&L for cement concrete (1:4:8), type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass-concrete complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar all as specifed and directed.
Demolition of cement concrete in ground floor and paving n.exc 15cm thick below or above ground level.
M&L for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of flooring and hardstanding
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular area) of each tile exceeding 0.06 Sqm but not exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed by matching cement all as directed.
M&L for Glazed ceramic coloured tiles in vertiacal surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in colour cement match.
M&L for 20mm thick screed bed or bedding layer of CM (1:6) for laying tiles.
M&L for 10mm thick CM (1:4) of backing coat to received tiles on vertical surfaces of brick or concrete masonry.
M&L for cement concrete tiles 20cm x 20cm x20mm thick, machine pressed, set and jointed in neat cement slurry with grey cement and pigment over and including screed bed 20mm thick in CM (1:6) as in path, complete all as specified and directed.
Taking down cement plaster any description of brick / concrete surfaces all as directed.
S&F for wire netting 0.9 mm dia and 12mm mesh lathing to wood or metal studding joints etc in wall ceiling stanchion beams etc including all laps cutting and waste
M&L for lath plastering 15mm thick in CM 1:6 on one side of lathing, finishing plastered surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for lath plastering 20mm thick on other side of lathing in two layers, 1st layer 12mm thick in CM 1:4 and 2nd layer 8mm thick in CM 1:4, finishing plastered surfaces even and smooth without using extra cement including mixing of Water Proofing Compound (WPC) as per manufactuerer’s instructions, complete all as specified and directed.
M&L for applying two coats oil bound distemper over a coat of primer including wall care putty on new plastered surface of walls
All as per item No. 62 above but for old surfaces of wall including removal of old treatment complete all as specified and directed.
M&L for preparation of newly plastered surfaces on walls over 10 cm width or girth and applying two coats of acrylic base exterior paint over a coat of primer as per manufacturer's instructions (camaflouge type : dimension exc 2.5 RM but not exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE)).
M&L for preparation of old decorated/painted concrete surfaces on walls over 10 cm width or girth and applying two coats of acrylic base exterior paint over a coat of primer as per manufacture instructions (camaflouge type : dimension exc 2.5 RM but n.exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE)).
M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling & mass concrete for foundation.
M&L for Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 mtr mean Radius, built in CM 1:4, complete all as specified and as directed.
M&L for PCC 1:2:4 type, B0 (using 20mm graded crushed stone aggregate) as in benching, rounded or chamferred on edges etc complete all as specified and directed.
M&L for extra forming fair finished to drain or channel 15 cm innner girth in cement concrete surface using extra cement, including forms, mouldes, mitred ends etc complete.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finishing the surfaces even and smooth using extra cement complete all as specified and directed.
M&L for providing pre cast cement concrete 1:2:4 type B1 set in CM (1:4) as in cover slab and similar articles with plain faces complete all as specified and directed.
M&L for MS TMT bar 6 to 8 mm dia cut to length bent to shape required including cracking bending and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips etc completed as specified and directed.
S&F 150mm dia salt glazed stoneware drain pipe laid in trenches and jointed etc complete as specified and directed (depth upto 1.5 mtr).
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C2 for 150mm dia pipe.
Constructionof brick masonary septic tank 25 users capacity concrete all as specified and show on drawing (Ref Drg No. AF/TD/STRU/236 heet 1/2 & 2/2).
Soakge wells of size 1.2 M dia x 3.0 M deep in ordinary soil foundation in PCC 1:3:6, wells of honey combined and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in CM (1:4), RCC cover slab in M-25 / RR masonry / filing with brick bats complete all as shown on drawing No. AF/TD/6/92-1/1 dt 18 Dec 1992.
M&L for 50mm thick PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in flooring complete all as specified and directed.
M&L forming construction joints 65mm deep x 10mm wide filled with sealing compound grade 'B' complete all as specified and directed.
Taking down carefully old unserviceable aluminium copper point wiring (light, fan,socket or power etc) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket outlet, bulk head fittings, tube light fittings, MCBs, DBs etc and making good the disturbed surface complete all as specified and as directed.
M & L for point wiring complete with 1.5 sqmm PVC insulated cable FRLS, 1100 volts grade as per IS-694 stranded copper conductor cable drawn through and including PVC cassing and capping (not less than 20 mm wide) complete with all fittings and acessories and 1.5 sq mm stranded copper conductor cable PVC insulated cable FRLS 1100 volts grate for earth continuity conductor for to common earth & connecting to earth dolly for one light / fan point controlled by one way switch, fabricated terminal box made out of PVC with screws and washers for housing switches, socket outletes, fan regulators etc. for one LED tube light/LED lamp/Bldg security light controlled by one way switch all as specified and directed .
All as per item No. 80 here-in-above but one ceiling fan/exhaust fan controlled by one way swithc
All as per item No. 80 here-in-above but one switch socket out let point 5A on indepndent board.
All as per item No. 80 here-in-above but for point wiring with 2.5 sqmm single core stranded copper conductor and one run of 1.5 Sqmm copper conductor, stranded for earth wire for one switch socket out let point, 15/16 amps on the independent board.
Supply and fix 18 watt LED light with batten for LED tube light 4 ft, suitable for single phase 230 volts. 50 Hz AC supply and mounted on wall or ceiling complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sq mm (nominal area) of make havells cat No LHEXBTP71N1S002 or equibalent model in Bajaj/Crompton Greaves/Philips.
M&L for lamp holder, polycarbonate type with back plate alongwith 9/10 watt LED Lamp. Complete all as specified and as directed.
S&F for compact building security light luminaire 25 watt LED light including bracket made out of 40 mm bore light grade GI pipe ISI marked bent to required shape not less than 1.2m. (ISI marked) duly fixed with MS clamps of 3 mm thick - 02 Nos. nut bolts etc complete all as specified and directed. Make : Havells cat No. ENDURA PEARL 25W MP or equibalent in Bajaj/Crompton Greaves / Philips.
S&F for switch piano flush type single pole, one way 5 Amps (ISI marked) complete all as specified and directed.
S&F for ceiling rose, 3 pin polycarbonate isolated body ISI marked complete all as specifed and directed.
S&F switch socket combination 5 pin, 5 Amp flush type ISI marked complete all as specifed and directed.
S&F switch socket sombination 5 in 1. 3 pin, 5A & 15A flush type universal, 240 V all as per relevant IS complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. 120W, 230V ISI (Marked) complete all as specified and directed.
Taking down only ceiling fan 1200mm/1400mm sweep any make carefully after disconnecting electrical connection ceiling cable end. dismantling blades and removing fan and blades for refixing all as specified and directed.
Hanging of ceiling fan 1200mm/1400mm sweep any make removed from item No. 92 above and making electrical connection to fan after cleaning of blades and fan complete all as specified and directed.
S&F in repairs sheet metal enclosure concealed to the wall for 8 way Distribution Boards (DB's), double door, single pole & neutral with 100 amps rated bus bar, suitable for fixing MCBs/RCBs all as specified and directed.
S&F in repairs sheet metal enclosure concealed to the wall for 4 way Distribution Boards (DB's) , double door, VTPN with 250 amps rated bus bar complete all as specified and directed.
S&F for MCB FP, 125 Amps capacity 415 Volts complete all as specified and directed.
S&F for MCB's SP, C curve, 5-10 amps 10 KA, 240 volts all as specified and directed.
S&F for MCB SPN/DP, C curve, 20-32 Amps, 10 KA 240 Volts all as specified and directed.
M&L for submain wiring alongwith earth wire of size 2x4.0 sq mm + 1x4.0 sq mm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as requied as specified and as directed including taking down old un servicable sub main wairing all as specified and as directed. Note : Two runs of PVC wire ,one run of earth wire and one run of PVC conduit shall be measured and paid as one length.
Material and labour for Earthing complete with galvanized steel earth plate electrode 600x600x6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4 mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Pt-I including necessary excavation and earth work, PCC (1:3:6) type C-1 with 50mm thick precast RCC (1:2:4) type B-1 cover slab (reinforced with 8mm dia deformed bar @ 15cm C/C both ways and suitable handle of 10 mm dia round bar including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (medium grade) wire mesh, lugs complete in all respect, GI earth strip protected by 15 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed including disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and directed. Note : GI earth wire and protection pipe upto 7.5 mtr shall be deemed to be included in the quoted rate.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including taking down old unserviceable one. (from existing panel to VTPN DB.
Excavation in trenches in soft/loss soil n.exc 1.5 m wide and n. exc 1.5 mtr depth and getting out, including trimming the sides and forming botton surface to required levels for drain,manhole or laying cables in soft/loss soil complete all as specified.
Sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punning thickness up to 18 cm and consolidation complete all as directed. Note : Punned thickness only shall be mearured for payment
Returning, filling in trenches in layers n.exc 25 cm after laying of cables including spreading, levelling and well remming in soft / lose soil complete all as specified and directed.
Removing surplus excavated material soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 mtr above the starting point for soft/lose soil complete as directed
Supply & laying common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenched for protection of cables (LT) al as specified and as directed
LESS SCHEDULE OF CREDIT (NOTE : The bidders are required to quote the same amount as inserted in estimated rate column against the group of credit items. For details refer Schedule of Credit including notes therein of tender documents.
RUPANJAL BORBORUAH
M/S GOPAL ROY AND CO
M/S SR CONSTRUCTIONS
NIHAR ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .