Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC | L1 | Accepted-AOC approved |
Tender Value
₹1.4 L
EMD Value
₹2,858
Closing Date
23 Mar 2021, 6:00 pmClosed
Executive Engineer (E)
O/o The Executive Engineer ( Electrical) 1ST Floor, Bhopal House, Lalbagh Lucknow
Providing Electrical Installation for false ceiling for O/o Director and ADG at first floor in the O/o Advisor Telecom ,U.P. East, LSA, CTO Bldg., GPO Compound, Hazratganj, Lucknow and minor EI work in O/o DirectorElectrical,DDG Term office Viram kh
2021_BSNL_72395_1
30/TEDL/BSNL/LKO/2020-2021 Dated 04/03/2021
Open Tender
Electrical Works
Item Rate
15 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Lucknow
₹2,858
4 Jun 2021
5 Mar 2021
25 Mar 2021
5 Mar 2021
23 Mar 2021
5 Mar 2021
SH-I:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 5-32A 'C' Series single pole
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (b) 3x4 sq mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (a) 180 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (b) 200 mm X 150 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (b) 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. © 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (d) 6 pin 15/16 A socket outlet
SITC of 2' X 2' size Completely Diffused high efficiency 36 W LED Luminaire recessed mounting complete with accessories etc. installed directly on false ceiling with suitable chain & fastener i/c connections etc.as required.(Philips/Havell's or ss make)
Supplying and fixing of 400mm sweep oscilating type cabin fan suitable for operation on 230 volts 50 Hz AC supply complete with accessories such as wire mesh guard, built in speed regulator flexible copper wire of suitable capacity for connection, mounting arrangement, testing & commissioning etc. as required.(M/s,Havells/ Crompton or SS make)
Dismantalling of old batten wiring,switch board etc of ADG room complete as reqd.
Shifting of 1.5 TR split AC indoor unit i/c dismantalling of copper pipe and reconnecting after necessary extension of pipe etc complete as required
Supplying and fixing of 20 mm flexible steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing extra copper pipe line both 1/4" gas line and 5/8" for liquid line OR suitable dia match with existing split AC i/c brazing etc complete as reqd.
Supplying and laying 3 core 2.5 sqmm PVC insulated and sheathed flexible copper cable suitable for above AC units wherever required including termination required.
S/F suitable dia plastic dranage pipe etc complete as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .