Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹47.5 LAccepted-Finance | L-1 | Accepted-Finance Being L-1 Bidder | |
| 2 | L-2₹51.6 L+₹4.1 L (8.63%)Rejected-Finance | L-2 | Rejected-Finance Being Other than L-1 Bidder | |
| 3 | L-3₹52.6 L+₹5.1 L (10.7%)Rejected-Finance | L-3 | Rejected-Finance Being Other than L-1 Bidder | |
| 4 | L-4₹53.7 L+₹6.2 L (13.0%)Rejected-Finance | L-4 | Rejected-Finance Being Other than L-1 Bidder | |
| 5 | L-5₹54.9 L+₹7.3 L (15.5%)Rejected-Finance 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L-5 | Rejected-Finance Being Other than L-1 Bidder |
| Sl No | Description | Qty | Unit | Shree Mahavir Associates L5 | M/s Bapujee Builders and Traders L4 | R K Traders L1 | TECHNO SOFT SOLUTIONS L2 | M/s M M Engineering Systems L7 | chauhan syndicate L3 | B.Veerabhadra Rao L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed. | 33 | Cum | 390 ₹12,870 | 300 ₹9,900 Lowest | 350 ₹11,550 | 450 ₹14,850 | 300 ₹9,900 Lowest | 455 ₹15,015 | 450 ₹14,850 |
| 2.00 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. | 32 | Cum | 190 ₹6,080 | 250 ₹8,000 | 150 ₹4,800 | 140 ₹4,480 Lowest | 150 ₹4,800 | 255 ₹8,160 | 160 ₹5,120 |
| 3.00 | Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed. | 1 | Cum | 390 ₹390 | 450 ₹450 | 300 ₹300 Lowest | 350 ₹350 | 350 ₹350 | 410 ₹410 | 320 ₹320 |
| 4.00 | Supply and Laying Double Wall corrugated (DWC) HDPE pipe 50mm outer dia for protection go UG cable as per IS: 16205 (part 240 of 2017 complete all as specified. | 100 | RM | 390 ₹39,000 | 450 ₹45,000 | 350 ₹35,000 | 450 ₹45,000 | 320 ₹32,000 | 460 ₹46,000 | 300 ₹30,000 Lowest |
| 5.00 | Supply and Laying Double Wall corrugated (DWC) HDPE pipe 90mm outer dia for protection go UG cable as per IS: 16205 (part 240 of 2017 complete all as specified. | 100 | RM | 790 ₹79,000 | 850 ₹85,000 | 700 ₹70,000 Lowest | 750 ₹75,000 | 850 ₹85,000 | 770 ₹77,000 | 780 ₹78,000 |
| 6.00 | Supply and fixing GI Pipe light grade with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable of following sizes of dia bore complete all as specified and directed.
(a) 80 mm dia | 6 | RM | 820 ₹4,920 Lowest | 990 ₹5,940 | 900 ₹5,400 | 950 ₹5,700 | 950 ₹5,700 | 1,200 ₹7,200 | 880 ₹5,280 |
| 7.00 | (b) 40 mm dia | 6 | RM | 580 ₹3,480 | 690 ₹4,140 | 600 ₹3,600 | 650 ₹3,900 | 500 ₹3,000 Lowest | 685 ₹4,110 | 650 ₹3,900 |
| 8.00 | S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER /400 VOLTS/ LT CABLE CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. | 5 | Each | 550 ₹2,750 | 559 ₹2,795 | 450 ₹2,250 | 430 ₹2,150 | 400 ₹2,000 Lowest | 488 ₹2,440 | 550 ₹2,750 |
| 9.00 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. | 3 | Each | 350 ₹1,050 | 350 ₹1,050 | 300 ₹900 | 380 ₹1,140 | 250 ₹750 Lowest | 488 ₹1,464 | 350 ₹1,050 |
| 10.00 | Supply,laying, testing and commissionnig of UG HT cables, 11000 volts grade, 3 core x 95 sqmm (Earthed), XLPE insulated and PVC sheathed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. | 12 | RM | 1,800 ₹21,600 | 1,800 ₹21,600 | 1,600 ₹19,200 Lowest | 1,800 ₹21,600 | 1,800 ₹21,600 | 1,850 ₹22,200 | 1,680 ₹20,160 |
Tender Value
Refer Docs
EMD Value
₹96,500
Closing Date
2 Sept 2026, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
UPGRADATION OF TRANSFORMER 250 KVA TO 400 KVA ALONGWITH ALLIED E/M WORKS IN ARMY PUBLIC SCHOOL LOCATION UNDER GE (I) GOS
2026_MES_766651_2
GE/GOS/TOK/30 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GOS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹96,500
8 Oct 2026
12 Aug 2026
5 Sept 2026
12 Aug 2026
2 Sept 2026
19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed. | 33 | Cum | - | - |
| 2 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. | 32 | Cum | - | - |
| 3 | Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed. | 1 | Cum | - | - |
| 4 | Supply and Laying Double Wall corrugated (DWC) HDPE pipe 50mm outer dia for protection go UG cable as per IS: 16205 (part 240 of 2017 complete all as specified. | 100 | RM | - | - |
| 5 | Supply and Laying Double Wall corrugated (DWC) HDPE pipe 90mm outer dia for protection go UG cable as per IS: 16205 (part 240 of 2017 complete all as specified. | 100 | RM | - | - |
| 6 | Supply and fixing GI Pipe light grade with all fittings for passing of cables fixed to pole / wall / laid under floor or roads including all fixing accessories complete for protection of cable of following sizes of dia bore complete all as specified and directed.
(a) 80 mm dia | 6 | RM | - | - |
| 7 | (b) 40 mm dia | 6 | RM | - | - |
| 8 | S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER /400 VOLTS/ LT CABLE CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. | 5 | Each | - | - |
| 9 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. | 3 | Each | - | - |
| 10 | Supply,laying, testing and commissionnig of UG HT cables, 11000 volts grade, 3 core x 95 sqmm (Earthed), XLPE insulated and PVC sheathed, steel wire armoured, with multi stranded aluminum conductor, heavy duty conforming to latest relevant IS, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. | 12 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_878687.xls
BOQ • 1.07 MB
tender_docs.pdf
Tender Documents • 1.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .