GEMC-511687782764196
Awarded to ESTEEM INDUSTRIES INC
₹1.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Table Top Autoclave | ESTA-112 | - | 1 NOS | ₹1.4 L | 142,900 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: Esteem
Model: ESTA-112 2EF EPIP JHARMAJRI INDUSTRIAL AREA BADDI SOLAN HIMACHAL PRADESH 174103 | SOLAN | HIMACHAL PRADESH | 174103 | Make: Esteem
Model: ESTA-112 | L1 | Qualified | |
| 2 | L2₹2.8 L+₹1.3 L (92.4%)Qualified Make: BioEra
Model: ICANCLAVE AUTOCLAVE 23 LITERE INDIA | Make: BioEra
Model: ICANCLAVE AUTOCLAVE 23 LITERE | L2 | Qualified | |
| 3 | L3₹2.8 L+₹1.4 L (95.9%)Qualified Make: REICO
Model: REICO 23 JAGATPURA JAIPUR RAJASTHAN 302017 | JAIPUR | RAJASTHAN | 302017 | Make: REICO
Model: REICO 23 | L3 | Qualified | |
| 4 | L4₹4 L+₹2.6 L (179.9%)Qualified Make: Jindal
Model: Jindal Table Top Autoclave 4 26 SITE IV SAHIBABAD IND AREA DISTT GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Make: Jindal
Model: Jindal Table Top Autoclave | L4 | Qualified | |
| 5 | Disqualified Make: Tanco
Model: Tanco20 PASCHIM VIHAR WEST DELHI DELHI 110063 | WEST DELHI | DELHI | 110063 | Make: Tanco
Model: Tanco20 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 Sept 2018, 10:00 amClosed
Table Top Autoclave ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Configuration Type: Table top or bench top steam steriliser * Sterlizer chamber capacity (usable volume) 22 17-25 Type of cycle processes available: B-process B-process
N- process Sterlizer Chamber Type Circular Circular
Rectangular Steriliser chamber material SS 316 or better grade steel * Working Pressure of Chamber 2.2 * Design Pressure of Chamber 3.8 * Chamber pre- heating facility: Equipped with electrically heated jacket for preheating true true
false 1/5 on standby mode: Type of Steriliser Chamber Door: Hinged Door Radially Opening Door
Sliding Door
Hinged Door Steriliser Chamber door Locking facility: At least two locking bolts * Steriliser Chamber door Operation: Manual Manual
Automatic (with manual override facility in case of auto mechanism failure) Door sealing: By elastomeric rubber gasket suitable to withstand temperature upto 140 degree C & pressure upto 20-30 psi * Inlet Air Filtration: Yes
Atmospheric air shall enter the sterilisation chamber after its filtering by a disposable air filter provided in the equipment. * Air Filter efficiency: >= 99.998% * Sterilising Cycle Processes available: 121 degree C Wrapped
134 degree C Wrapped
134 degree C Flash/Rapid open instrument cycle
134 degree C textile
Test programs: Bowie & Dick
Leak Test 121 degree C Wrapped
Leak Test Steriliser has water circulation system so that no drain point and fixed water inlets are required: Yes Yes Water Storage Tank: Inbuilt water reservoir with Storage capacity of 3-5 litre with easy access for cleaning to avoid biofilm available: Yes * Steriliser have inbuilt steam generator designed for integrated energy storing system for building up power for sterilisation load in shot time: true * Type of control system available for Steriliser cycle operation: Microprocessor based PLC system specifically designed for * 2/5 sterilisation operations
with CPU processor with battery back up
digital input/output controls
analog measuring inputs & COM ports for printer and PC connectivity. Automatic process checking
self checking of safety devices and failure correction should be possible by the control system. Power Source: 220 Volt
50 Hz AC electric supply * Power supply: 220 volt
50 Hz AC electric supply single phase * Number of Trays in sterillser chamber 2 2
3
4
5 (or higher) Sterilliser Loading Type: Front loading Front loading
Top Loading Audio- visual Alarm facility available for notifying: Temperature sensor failure
Pressure sensor failure
Phase time out
Door improperly closed
Power failure (no alarm if duration of power failure < 10 sec)
Safety device malfunctioning
Low water level Temperature sensor failure
Low water level Accessories
Consumables & Warranty Accessories: Each Tabletop autoclave unit shall be supplied along with: One Rack unit with 5 levels and one set of suitable sized instrument trays. * Warranty 3 3
5 (or higher) Consumables: Sterilizer unit to be supplied with consumables sufficient to carry out sterilization cycles (No) sufficient for 100 sterilization cycles sufficient for 50 sterilization cycles
sufficient for 100 sterilization cycles (or higher) Overall Size Overall Height: 460 * Overall Width: 570 * 3/5 Overall Depth: 670 * Quality and Certifications Compliance of Chamber for Chamber Pressure Equipment Directives (PED) AND EN 13445 norms: false true
false Quality Compliance available for quality systems as per as per ISO 9001:2000
EN ISO 13485:2003
ISO 14001:2004: true true
false Certifications: US FDA
European CE US FDA
European CE * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devanarayanan P perumal 605006
Indira Nagar 1 15
601294
GEM/2018/B/85401
GeM Contract
Table Top Autoclave
GeM Contract
15 days
Puducherry; Pondicherry
PRODUCT
Awarded to ESTEEM INDUSTRIES INC
₹1.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Table Top Autoclave | ESTA-112 | - | 1 NOS | ₹1.4 L | 142,900 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Table Top Autoclave ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Configuration Type: Table top or bench top steam steriliser * Sterlizer chamber capacity (usable volume) 22 17-25 Type of cycle processes available: B-process B-process | - | - | - |
| N- process Sterlizer Chamber Type Circular Circular | - | - | - |
| Rectangular Steriliser chamber material SS 316 or better grade steel * Working Pressure of Chamber 2.2 * Design Pressure of Chamber 3.8 * Chamber pre- heating facility: Equipped with electrically heated jacket for preheating true true | - | - | - |
| false 1/5 on standby mode: Type of Steriliser Chamber Door: Hinged Door Radially Opening Door | - | - | - |
| Sliding Door | - | - | - |
| Hinged Door Steriliser Chamber door Locking facility: At least two locking bolts * Steriliser Chamber door Operation: Manual Manual | - | - | - |
| Automatic (with manual override facility in case of auto mechanism failure) Door sealing: By elastomeric rubber gasket suitable to withstand temperature upto 140 degree C & pressure upto 20-30 psi * Inlet Air Filtration: Yes | - | - | - |
| Atmospheric air shall enter the sterilisation chamber after its filtering by a disposable air filter provided in the equipment. * Air Filter efficiency: >= 99.998% * Sterilising Cycle Processes available: 121 degree C Wrapped | - | - | - |
| 134 degree C Wrapped | - | - | - |
| 134 degree C Flash/Rapid open instrument cycle | - | - | - |
| 134 degree C textile | - | - | - |
| Test programs: Bowie & Dick | - | - | - |
| Leak Test 121 degree C Wrapped | - | - | - |
| Leak Test Steriliser has water circulation system so that no drain point and fixed water inlets are required: Yes Yes Water Storage Tank: Inbuilt water reservoir with Storage capacity of 3-5 litre with easy access for cleaning to avoid biofilm available: Yes * Steriliser have inbuilt steam generator designed for integrated energy storing system for building up power for sterilisation load in shot time: true * Type of control system available for Steriliser cycle operation: Microprocessor based PLC system specifically designed for * 2/5 sterilisation operations | - | - | - |
| with CPU processor with battery back up | - | - | - |
| digital input/output controls | - | - | - |
| analog measuring inputs & COM ports for printer and PC connectivity. Automatic process checking | - | - | - |
| self checking of safety devices and failure correction should be possible by the control system. Power Source: 220 Volt | - | - | - |
| 50 Hz AC electric supply * Power supply: 220 volt | - | - | - |
| 50 Hz AC electric supply single phase * Number of Trays in sterillser chamber 2 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 (or higher) Sterilliser Loading Type: Front loading Front loading | - | - | - |
| Top Loading Audio- visual Alarm facility available for notifying: Temperature sensor failure | - | - | - |
| Pressure sensor failure | - | - | - |
| Phase time out | - | - | - |
| Door improperly closed | - | - | - |
| Power failure (no alarm if duration of power failure < 10 sec) | - | - | - |
| Safety device malfunctioning | - | - | - |
| Low water level Temperature sensor failure | - | - | - |
| Low water level Accessories | - | - | - |
| Consumables & Warranty Accessories: Each Tabletop autoclave unit shall be supplied along with: One Rack unit with 5 levels and one set of suitable sized instrument trays. * Warranty 3 3 | - | - | - |
| 5 (or higher) Consumables: Sterilizer unit to be supplied with consumables sufficient to carry out sterilization cycles (No) sufficient for 100 sterilization cycles sufficient for 50 sterilization cycles | - | - | - |
| sufficient for 100 sterilization cycles (or higher) Overall Size Overall Height: 460 * Overall Width: 570 * 3/5 Overall Depth: 670 * Quality and Certifications Compliance of Chamber for Chamber Pressure Equipment Directives (PED) AND EN 13445 norms: false true | - | - | - |
| false Quality Compliance available for quality systems as per as per ISO 9001:2000 | - | - | - |
| EN ISO 13485:2003 | - | - | - |
| ISO 14001:2004: true true | - | - | - |
| false Certifications: US FDA | - | - | - |
| European CE US FDA | - | - | - |
| European CE * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devanarayanan P perumal 605006 | - | - | - |
| Indira Nagar 1 15 | - | - | - |
Exempted
16 Nov 2018
22 Sept 2018
contract_GEMC-511687782764196.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_601294.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .