Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.4 Cr+₹6.5 L (4.69%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | ₹1.4 Cr+₹6.5 L (4.69%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.5 Cr+₹9.5 L (6.87%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹1.5 Cr+₹9.5 L (6.87%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹1.5 Cr+₹10.5 L (7.58%)Rejected-Finance | ₹1.5 Cr+₹10.5 L (7.58%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹1.5 Cr+₹12.6 L (9.12%)Rejected-Finance | ₹1.5 Cr+₹12.6 L (9.12%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.6 L
Closing Date
12 Sept 2024, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
ADDN ALTN TO BLDG OR MD ACCN AT ICHHAMATI LINE UNDER GECENTRAL DELHI CANTT10
2024_MES_658545_1
CEDZ/TOKEN-14 OF 2024
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt-10
As per NIT
8 documents required · 8 mandatory
₹1,000
GE Central
₹2.6 L
Yes
23 Nov 2024
8 Jun 2024
14 Sept 2024
8 Jun 2024
12 Sept 2024
27 Jul 2024
8 Jun 2024 - 15 Jun 2024
Amount
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc incl remove all debris in 2 KM form site complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces , applied in two layers i.e.. Ist layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd ( top ) layer of 5 mm thick rendering in cement mortar (1:4 ) mixed with WPC finished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately.)
M&L for rendering 10 mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified.
M&L for Rendering 5 mm thick in CM 1:3 on ceiling concrete surfaces finished even and fair without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of walls and providing and applying wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Two coats of Acrylic Smooth exterior paint of required shade applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper over and including priming coat complete all as specified and directed.
M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper over and including priming coat complete all as specified.
M&L for old decorated surfaces (plastered or unplastered) of wall and complete removal of existing treatment by rubbing , brooming down, washing with water etc and applying two coat of oil bond distemper on wall complete all a specified.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing , brooming down, washing with water etc and providing and applying plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
M&L for Preparation of old surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified.
Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (single layer) all as specified and directed.
Demolition Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) all as specified and directed.
Removing soil excavated material or mud-phuska etc. exc. 1.5Km but n exc 5km and depositing where directed all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as specifiedd & directed.
M&L for roof treatment as per the description below including dismantling/taking down existing roof treatment complete:- a) Preparation of roof surfaces by removing all loose material /dust extra for carrying out water proofing treatment. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 kg/Sqm and apply two coat of silver shield bitumestic aluminum paint complete all as specified and directed.
S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on and including 20 mm thick cement and sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
Supply only integral water proofing compound (ISI marked).
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., all as directed.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks, old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed.
Dismantling of wall and ceiling/cup board, board (fibre, pulp, AC boards etc) any thickness including cover fillets, removing the wiring all as specified and directed.
S&F factory made 18mm thick 100% solid WPC (Wood polymer Composite) Laminated Board of required size comprising of virgin PVC resin of K value 57-60 (Suspension Grade), Calcium Carbonate and natural fibers (Wood powders/rice hisk/ wheat husk) and non toxic additives, made from Extrusion process WPC foam sheet Single Extruded (Inner) with having minimum density not less than 650 Kg/cum having good screw holding capcity (screw withdrawal strength of 2000 N (Face) & 1100 N (Edge) Minimum Compressive strength of 50 N/mm2, an resistance of spread of flame of class A category with property of being Termite/Borer free. Water/moisture proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixing stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-in-Charge. Material test certificate and authentication should be compulsory provided by te manufacturing company: For WC/Bathroom/ Toilet/ Kitchen and Cabinets.
S&F of Stainless steel auto closing hinges openable at 0 degree for kitchen cabinet shutters and bed room cub boards complete all as per specified and directed.
S&F of stainless steel handles 100 mm size for kitchen cabinet shutters and bed room cub boards complete all as per specified and directed.
S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed.
S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws.
S&F 1.6 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M & L for 2nd Second class hard-wood in scantlings clean swan timber and fixed all as specified & directed.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame)
Taking down chowkhat or frame exceeding 1.5 Sqm and not exceeding 4 Sqm each with shutter (without taking off shutter from the frame)
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
Providing 30mm thick FACTORY-MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /Cum Manufactured by an ISO-9001-2015 certified Company, Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (Confirming as per IS:4020). The door should be water proof, termite proof,fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through Other hardwares shouldbe fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawings.” Note: Fixture/fittings shall be measured & paid under relevant item
S&F Factory Made double rebated extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicityindex of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge.Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made
S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 50 x 100 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicityindex of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge.Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made
M&L aluminium alloy powder coated windows including aluminium coated frames sliding track, bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double riveted and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter sliding type with aluminium sections as per series-A (15mm) 3 track of Jindal section number for sliding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrangement spring action and glazing clips joint cleats rubber gaskets etc including provision of 5.5 mm thick tinted frosted glass of superior quality and stainless steel wiremesh including all standard fittings complete all as specified and directed.
S&F aluminium ventilator partly glazed/ gauzed including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws , Stainless steel wire mess , 3mm thick sheet glass etc. provision for fixing the exhaust fan complete all as specified and as directed
S & F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
S&F MS butt hinges medium weight 100 mm size fixed with MS screws.
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws.
S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer
M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified
M & L for preparation of Old or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S&F for stainless steel plate rack of size 90x80x25 cm depth made out of 1mm thick sheet complerte all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, complete of size 15mm bore all as specified and directed
All as per item No. 52 above but 20 mm bore .
All as per item No. 52 above but 40 mm bore .
Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as directed
All as per item No. 55 above but 20 mm dia
All as per item No. 55 above but 40 mm dia
S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as directed.
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate) as required for concealed water tubing etc cutting exceeding 10cm girth but not exc. 20 cm all as directed.
Supply and fix vitreous China wash hand basin with pedestal white of size 550X400mm including waste chain and plug and porcelain stopper and waste pipe & Brass chromium plated waste coupling including all necessary fitting and fixtures complete all as specified
S&F in repair vitreous China wash down water closet pan (pedestal pattern) white incl 'P' or 'S' 100 mm trap and making good the disturbed surface to match with the existing complete all as specified and all as directed.
Supply only plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device, complete all as specified and directed.
Supply only PVC low level white flushing cistern valveless syphonic action type 10 lts capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified and directed.
S & F in repairs 15 mm dia 600mm long PVC connections with brass check nut complete all as specified and directed.
S & F in repairs Glass Corner Shelf 6mm thick including CP railing radius 250mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with CP railing complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Health faucet, CP brass with 1.50m long flexible pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F for 15 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S&F for 20 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F in repairs Chromium plated brass overhead shower with arm complete all as specified and directed.
S & F in repair concealed brass chromium plated stop valve fancy type suitable for 15mm bore of pipe with long shank and cup complete all as specified.
S&F in repairs Brass chromium plated mode 2 in 1 WHB mixture model Quarter half turn (SOLO) of as complete all as specified & directed.
S&F in repairs brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) as all specified and as directed.
S&F in repairs Brass chromium plated mode 2 in 1 sink mixture model Quarter half turn (SOLO) of as complete all as specified & directed.
S&F in repairs chromium plated soap dish fancy type complete all as specified and directed .
S & F in repair towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embedded in cement mortar 1:3 with MS screws etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) as in sunken floors, paving and any position and any thickness up to double story building complete all as specified and directed.
M & L for PCC 1:5:10 type E-2 (using 40mm graded aggregate) use as in sunken floor finished even and fair without using extra cement complete all as specified and directed.
Supply only for broken brick coarse aggregate n.exc 40mm deposited, spread and levelled in layers watered and rammed to a true surfaces complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
S & F for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm ( size 450 mm x 450 mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
S & F for Vitrified ceramic tiles light shade 10 mm thick (squqre/rectangular), polished area of each exceeding 0.42 sqm but not exceeding 1.00 sqm ( size 600 mm x 1200 mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar (1:4) all as specified and directed.
All as per item no. 86 except on vertical surfaces as in skirting etc over 10mm thick backing coat in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350 x 250 x 7mm / 450 X 350 X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for 18-20 mm thick Jet Black Granite (single piece in one direction and edges chamfered) work (table rubbed and polished) in steps, jambs, pillars window-cill, cooking platforms and including 15mm thick screed bed in cement mortar (1:4) pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed.
M&L for machine cut polished Kota stone 20-25mm thick as in floor, tread, riser, pillar fixed with neat cement slurry over screed bed of 20mm thick in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge
M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth without using extra cement, complete all as specified.
M & L for 40 mm thick cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fair using extra cement, complete all as specified.
Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone graded agg) as in louvers and jallies 25mm thick designed as fort pattern (measured solid) including all moulding but excluding frame and set in CM1:4 all as per sample shown and directed by engineer-in -charge.
Material and labour for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick including formwork for sides of slab etc. (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
S&F TMT steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, tank cover for polyethylene and polyethylene ball including taking out existing unserviceable overhead tank of any description including fitting and fixtures complete all as specified. (ISI Marked)
S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter including all fittings complete all as specified and directed.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors and on walls, soil, waste, vent pipe in any length with or without ears ,110mm bore complete all as specified and directed.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors and on walls, soil, waste, vent pipe in any length with or without ears 75 mm bore complete all as specified and directed. .
S&F for PVC (SWR) bends & Tee any radius, 110 mm bore complete all as specified and directed.
S&F for PVC (SWR) bends & Tee any radius, 75 mm bore complete all as specified and directed.
S&F for PVC (SWR)door plates , Y & T junction 110 mm bore with ovel access door complete all as specified and directed.
S&F for PVC (SWR)door plates , Y & T junction 75 mm bore with ovel access door complete all as specified and directed.
S&F for 100 PVC (SWR) bends with door plate complete all as specified and as directed.
S&F for 75 mm PVC (SWR) bends with door plate complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified and as directed.
S&F in repair 20 mm dia stainless steel tube for curtain rod including pair of suitable S.S brackets approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and directed.
Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm incl welding complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed
S&F 3.15mm dia plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and directed.
Demolition Brickwork or stone/ boulder masonry, built in lime cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified .
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in Cm 1:4 all as specified and directed.
All as per item No. 119 here in before but except brick.
M&L Providing cement concrete in coping type B-1 ,1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified.
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of any dia complete including removal of debris from site and deposited in low lying area.
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates incl packing under and haunching against the sides for 200mm internal Salt glazed stoneware drain pipes after they are laid and tested complete all as specified (thickness of concrete bed 150mm).
M&L for 200mm bore DWCPE drain pipes laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed.
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal Salt glazed stoneware drain pipes after they are laid and tested complete all as specified (thickness of concrete bed 150mm).
M&L for 150mm bore DWCPE drain pipes laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed.
M&L for PCC 1 : 2 : 4, type D2, using 40mm graded stone aggregates, as in foundation complete all as specified.
M&L for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finsihed even and smoth without using extra cement complete all as specified.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B1 using 20mm graded stone aggregate finished smooth and reforming benching as required for 150mm/200mm dia pipes complete all as specified.
M&L SFRC Factory made Precast cement concrete manhole cover' area of each cover exceeding 0.20 sqm but not exceeding 0.75 sqm 100 mm thick Type B1 1:2:4 concreting including grove and hook arrangement for lifting and placing in position and side covered by MS Sheet complete all as specied and directed by Engineer-in-Charge
M&L SFRC Factory made Precast cement concrete manhole cover' area of each cover not exceeding 0.20 sqm 50 mm thick Type B1 1:2:4 concreting including grove and hook arrangement for lifting and placing in position and side covered by MS Sheet complete all as specied
Surface dressing not exc 15 cm deep in soft / loose soil complete all as specified and as directed by Engr in charge
M&L for 75mm thick cement concrete type D-2 1:4:8 (40mm graded aggreate) filling and mass concrete
S&F Endura colours paving tiles 300cm X 300cm x 15-20mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 all as specified and directed.make: Johnson
M&L Providing cement concrete in coping type B-1 ,1:2:4 (using 12.5mm graded stone aggregate) complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified.
M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified.
M&L for sunken floor treatment as per the description below including dismantling of floor size not exceeding 4.00 Sqm each for WC/Bathroom and removing out the cinder/concrete filling from the sunken portion :- (a) Cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc (b) Supply and apply a glass fibre reinforced acrylic modified cementitious coating system with base coat of SikaTop & Seal-107 @ 1.5 kg/sqm over glass fibre reinforced Sika Fab -I and Top coat with Sika Top Seal-107 @ 1.5 kg/sqm etc complete. (c) Rendering 15 mm thick cement mortar 1:3 mixed with water proofing compound with Sika Plastocrete plus on fair faces of concrete surfaces finished even and smooth without extra cement for sunken slab (Note :- WPC shall be measured and paid separately) (d) Providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall complete. (e) Filling of sunken floors by 40mm graded Brick bats and finished with 50mm thick PCC 1:2:4 type B1 complete as directed. Note: The treatment work shall be executed by authorised manufacturer/applicator as approved by GE.
Demolition of cement concrete in ground floor and paving not exeeding 15cm thick below and above ground level complete all as specified and directed.
Description of Work / Item(s)
Amount
Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including all fittings such as switches, ceiling roses, pendants, regulator, sockets etc. and making good disturbed surfaces of walls, floor etc.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
Taking down old MCCB,TPN DBs , SPN DBs,SP MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed.
M&L for point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely)
One bell point controlled by one by one way switch (switch to be measured and paid separtely)
One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
All as per item No. 4.03 above, but on same board
One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately)
M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid in concealed New PVC conduit and conduit accessories complete all as specified and directed.
S &F in repair Submain wiring with two run single core 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandd copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20mm dia non metalic rigid in concealed new PVC conduit and conduit accessories complete all as specified and directed.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Suppy & fixing DBOXx MCB Protected Socket 15 Amps , PVC Plastic Base (white) with Plug top 25 Amps & MCB SP 32 amps complete all as specified and directed.Make : Anchor Roma /Legrand/indoasian or equivalent Note : 15 A switch to be provided near wash basing and separate socket to be provided near geyser rate to be included in quoated rate same for AC also.
M&L ceiling rose 3 phase PVC polycorbonate,isolated body.
M&L bell ding dong AC,230 volts,single pole all as specified and directed by Engr in Charge.
M&L for angle Lamp holder with metalic ring, pvc/ polycarbonate type back plate with LED bulb 09 watt, 900 lumens out put, 6500K suitable for B-22 base all as per directed
Supply and fix LED batten luminaire surface mounted ,4 feet system wattage of not less than 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 4000 to 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 5 years of replacement warranty on fittings complete all as specified and directed. Note : All servicable fittings will be deposited to MES yard.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 8 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 4000 to 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed with 5 years of replacement warranty on fittings complete all as specified and directed. Note : All servicable fittings will be deposited to MES yard.
Supply and fix not less than 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire with unbreakable poly carbonate materials with 1x12 watt LED bulb B22 Base, complete all as directed. Note: LED bulb shpuld not be paid separately.
Taking down carefully existing Geyser of any size and make from its position after disconnecting electric connection and checking it for its serviceability servicable geyser will be refix along with all asseries and unserviceable geyser will be repaired and refix as directed by EIC.
S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element 1.5 KW and not less than 5 star rating. Against def
S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
Taking down carefully the existing ceiling fan of 1200mm from its position after disconnecting electric connection and checking it for its serviceability as specified and directed. The same will be deposited to MES store.
Taking down carefully the existing Exhaust fan any size from its position after disconnecting electric connection and checking it for its serviceability and servicable fan will be refix and unservicable fan will be repaired and refix as specified and directed.
Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 900 RPM, steel body including metalic blade , single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing Ventilating Fan 250 mm sweep, 900 RPM, non metallic resin body, single phase 230 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
M&L for breaking old existing wall and making a provn for fixing of 300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
Supply and fixing ceiling fans (remote controll operated) complete with blade, down rods, electronic regulator and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM with service value not less than 7.5 CMM/W , BEE five star rated voltage range 140 - 280 volts power factor > .9 and THD < 20 % with brushess direct current motor (BLDC) all as specified and directed by Engr in Charge. Note : Down rods length should be as per site requirement.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed.
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete
M&L MCB ISOLATOR SPN 40 Amp.
S&F MCB SP 6-32 Amps 240 volts 'B' curve series 10 KA 50 HZ complete all as specified and directed.
GIAN ENGINEERS (BID ID -3093639)
Global Enterprises (BID ID -3093838)
M/S Chhavi Constructions Co (BID ID -3081631)
tarun construction co (BID ID -3093016)
CHOPRA BUILDERS (BID ID -3094278)
JYOTI ENTERPRISES (BID ID -3084692)
GIAN ENGINEERS (BID ID -3093639)
JYOTI ENTERPRISES (BID ID -3084692)
CHOPRA BUILDERS (BID ID -3094278)
M/S Chhavi Constructions Co (BID ID -3081631)
tarun construction co (BID ID -3093016)
Global Enterprises (BID ID -3093838)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .