| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L1 | Accepted-AOC Accepted being lowest quoted tenderer | |
| 2 | L2₹52.7 L+₹1.1 L (2.08%)Rejected-AOC | L2 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 3 | L3₹54.5 L+₹2.9 L (5.56%)Rejected-AOC M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | L3 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 4 | L4₹54.6 L+₹3.0 L (5.85%)Rejected-AOC | L4 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 5 | L5₹55.0 L+₹3.4 L (6.55%)Rejected-AOC | L5 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| Sl No | Description | Qty | Unit | Bharat Sales Corporation L7 | M/s A.K Construction L1 | M/S MALHOTRA ENGINEERING WORKS L5 | DINESH ELECTRICALS L2 | Ambrish Builders L4 | M/s Sohanil Construction L6 | ms shanti sons L8 | SALUJA CONSTRUCTION CO L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully sub main wiring of any type/size complete with MCB DBs MCB, isolators wooden batten, concealed/surface conduit/casing caping etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed. | 1,730 | RM | 50 ₹86,500 | 5 ₹8,650 Lowest | 10 ₹17,300 | 15 ₹25,950 | 5 ₹8,650 Lowest | 55 ₹95,150 | 10 ₹17,300 | 5 ₹8,650 Lowest |
| 2.00M&L for concealed sub main wiring using FRLS/FRLSH PVC insulated, unsheathed stranded copper conductor cable single core of following sizes of voltage rating upto and including 1100 volts drawn in and including rigid PVC concealed conduit of dia not less than 20 mm dia medium grade with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required and making good the disturbed surface shall deemed to be included in the quoted unit rate. | |||||||||||
| 2.01 | 2x4.0 sq. mm + 1x4.0 sq. mm earth wire | 250 | RM | 340 ₹85,000 | 200 ₹50,000 | 385 ₹96,250 | 270 ₹67,500 | 210 ₹52,500 | 95 ₹23,750 Lowest | 250 ₹62,500 | 175 ₹43,750 |
| 2.02 | 2x6 sq. mm + 6x sq. mm earth wire | 300 | RM | 420 ₹1,26,000 | 270 ₹81,000 | 425 ₹1,27,500 | 350 ₹1,05,000 | 310 ₹93,000 | 225 ₹67,500 | 340 ₹1,02,000 | 220 ₹66,000 Lowest |
| 2.03 | 2x10 sq. mm + 10x sq. mm earth wire | 150 | RM | 650 ₹97,500 | 400 ₹60,000 | 700 ₹1,05,000 | 550 ₹82,500 | 450 ₹67,500 | 365 ₹54,750 Lowest | 600 ₹90,000 | 520 ₹78,000 |
| 2.04 | 4x10.0 sq. mm +1x10.0 sq. mm earth wire | 80 | RM | 1,060 ₹84,800 | 750 ₹60,000 | 1,210 ₹96,800 | 900 ₹72,000 | 600 ₹48,000 | 595 ₹47,600 Lowest | 690 ₹55,200 | 880 ₹70,400 |
| 3.00M&L for surface sub main wiring using FRLS/FRLSH PVC insulated, unsheathed stranded copper conductor cable single core of following sizes of voltage rating upto and including 1100 volts drawn in and including non metallic PVC rigid, medium grade not less than 20mm dia surface conduit / non metallic PVC casing and caping with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. | |||||||||||
| 3.01 | 2x2.5 sq. mm + 1x2.5 sq. mm earth wire | 250 | RM | 180 ₹45,000 | 180 ₹45,000 | 260 ₹65,000 | 200 ₹50,000 | 160 ₹40,000 | 65 ₹16,250 Lowest | 230 ₹57,500 | 140 ₹35,000 |
| 3.02 | 2x4.0 sq. mm + 1x4.0 sq. mm earth wire | 250 | RM | 240 ₹60,000 | 200 ₹50,000 | 385 ₹96,250 | 250 ₹62,500 | 200 ₹50,000 | 95 ₹23,750 Lowest | 260 ₹65,000 | 175 ₹43,750 |
| 3.03 | 2x6 sq. mm + 6x sq. mm earth wire | 350 | RM | 320 ₹1,12,000 | 270 ₹94,500 | 425 ₹1,48,750 | 350 ₹1,22,500 | 300 ₹1,05,000 | 225 ₹78,750 | 340 ₹1,19,000 | 220 ₹77,000 Lowest |
Tender Value
₹85 L
EMD Value
₹1.5 L
Closing Date
6 Sept 2025, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
REPAIR/ MAINT/ UPKEEP OF SECONDARY DISTRIBUTION/ EARTHING INFRASTRUCTURE AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
2025_MES_724180_1
82011/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class C and Category b(i)
6 documents required · 6 mandatory
₹1,000
GE (West) Prayagraj
₹1.5 L
Yes
3 Nov 2025
2 Aug 2025
13 Sept 2025
2 Aug 2025
6 Sept 2025
23 Aug 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .