Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹33.1 L Quoted ₹34.1 L | L1 | Accepted-AOC BEING L1 BIDDER |
| 2 | L2₹36.7 L+₹2.7 L (7.92%)Rejected-Finance RONGMEN BLOCK IV NEAR UMROI MILITARY STATION P O BARAPANI SHILLONG 793103 | SHILLONG | RI BHOI | MEGHALAYA | 793103 | ₹36.7 L+₹2.7 L (7.92%) | L2 | Rejected-Finance OTHER THAN L1 BIDDER |
| 3 | L3₹37.3 L+₹3.3 L (9.63%)Rejected-Finance ADDITIONAL SECRETARIAT COMPOUND SHILLONG EAST KHASI HILLS MEGHALAYA 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹37.3 L+₹3.3 L (9.63%) | L3 | Rejected-Finance OTHER THAN L1 BIDDER |
| 4 | L4₹37.4 L+₹3.4 L (9.87%)Rejected-Finance | ₹37.4 L+₹3.4 L (9.87%) | L4 | Rejected-Finance OTHER THAN L1 BIDDER |
| 5 | L5₹38.0 L+₹3.9 L (11.5%)Rejected-Finance PINE DALE PINE MOUNT RIDGE SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹38.0 L+₹3.9 L (11.5%) | L5 | Rejected-Finance OTHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | M/s A L Traders L5 | M/s Nishi Kumar Das L4 | HAMZA CONSTRUCTION CO L6 | M S Umesh and Co L2 | SUNITA DEVI L3 | S K Construction L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. | 886.95 | Cum | 200 ₹1,77,390 | 250 ₹2,21,737.5 | 150 ₹1,33,042.5 | 145.11 ₹1,28,705.31 | 75 ₹66,521.25 Lowest | 132 ₹1,17,077.4 |
| 2.00 | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. | 2 | Cum | 400 ₹800 | 350 ₹700 | 300 ₹600 | 165.75 ₹331.5 | 110 ₹220 Lowest | 500 ₹1,000 |
| 3.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and as directed. | 532.17 | Cum | 100 ₹53,217 | 80 ₹42,573.6 | 45 ₹23,947.65 | 35 ₹18,625.95 | 30 ₹15,965.1 Lowest | 110 ₹58,538.7 |
| 4.00 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. | 356.78 | Cum | 150 ₹53,517 | 100 ₹35,678 | 90 ₹32,110.2 | 45 ₹16,055.1 | 30 ₹10,703.4 Lowest | 120 ₹42,813.6 |
| 5.00 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. | 5 | Cum | 7,000 ₹35,000 | 8,000 ₹40,000 | 6,200 ₹31,000 | 4,999 ₹24,995 | 5,500 ₹27,500 | 4,500 ₹22,500 Lowest |
| 6.00 | Supply and fixing/laying 40mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed. | 100 | RM | 350 ₹35,000 | 300 ₹30,000 | 420 ₹42,000 | 425 ₹42,500 | 250 ₹25,000 Lowest | 350 ₹35,000 |
| 7.00 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed.
Note :- Only punned down sand shall be measured. | 266.09 | Cum | 800 ₹2,12,872 | 900 ₹2,39,481 | 800 ₹2,12,872 | 999 ₹2,65,823.91 | 650 ₹1,72,958.5 Lowest | 980 ₹2,60,768.2 |
| 8.00 | M&L for burnt clay class B bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | 29.86 | Per 1000 | 13,000 ₹3,88,180 | 10,000 ₹2,98,600 Lowest | 12,000 ₹3,58,320 | 13,950 ₹4,16,547 | 11,000 ₹3,28,460 | 11,000 ₹3,28,460 |
| 9.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and as directed. | 500 | RM | 260 ₹1,30,000 | 180 ₹90,000 | 380 ₹1,90,000 | 239.51 ₹1,19,755 | 240 ₹1,20,000 | 170 ₹85,000 Lowest |
| 10.00 | All as item No 9 but of size 16Sqmm 2 core | 200 | RM | 210 ₹42,000 | 192 ₹38,400 | 280 ₹56,000 | 192.99 ₹38,598 | 250 ₹50,000 | 150 ₹30,000 Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
16 Apr 2026, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG PIN 793002
REPAIR/MAINT OF LT OVER HEAD LINES AND LT UG CABLES AND LT PANEL AND MCCB AND RELAYS AND ALLIED WORKS HAPPY VALLEY AND SE FALLS AREA UNDER GE SHILLONG
2026_MES_757775_1
GE/SHL/TOKEN-06 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE SHILLONG
₹78,000
Yes
3 Jun 2026
26 Mar 2026
17 Apr 2026
26 Mar 2026
16 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. | - | Cum | - | - |
| - | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and as directed. | - | Cum | - | - |
| - | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in hard/dense soil complete all as specified and as directed. | - | Cum | - | - |
| - | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. | - | Cum | - | - |
| - | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. | - | Cum | - | - |
| - | Supply and fixing/laying 40mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed. | - | RM | - | - |
| - | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed.
Note :- Only punned down sand shall be measured. | - | Cum | - | - |
| - | M&L for burnt clay class B bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | - | Per 1000 | - | - |
| - | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and as directed. | - | RM | - | - |
| - | All as item No 9 but of size 16Sqmm 2 core | - | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_848799.xls
BOQ • 0.36 MB
TENDERDOCU06.pdf
Tender Documents • 1.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .