Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.3 L+₹90,660 (2.80%)Rejected-Finance 61 C INDRA NAGAR BATWARA BATWARA SRINAGAR JAMMU KASHMIR 190004 UDYAM JK 21 0017961 01AACFC7985Q1ZX B R B | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹34.3 L+₹2.0 L (6.07%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.7 L+₹3.4 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹37.9 L+₹5.6 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
9 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS, C/o 56 APO
REPAIR/REPLACEMENT OF VARIOUS OUTDOOR LUMINARIES AND CONNECTED ITEMS AT BB CANTT SRINAGAR
2023_MES_622692_2
864/WS-73/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BB Cantt
As per tender
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹70,000
Yes
20 Jan 2024
18 Nov 2023
14 Dec 2023
18 Nov 2023
9 Dec 2023
25 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 mtr in wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Dry sand cushioning to underground cable provided with layer of 8cms thick before laying the cable and 15cms thick after laying and stretching the cable and punned to 18 cm thick complete all as specified and directed . Note: Only punned thickness shall be measured for payment purpose.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
M&L for Cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
M&L PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work,2/4 poles structures platforms repairs and finishing the surfaces fair in forms complete all as specified and directed.
M&L for 150 mm thick cement concrete (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in floor/ hard standing in power grid, 2/4 pole structure, complete all as specified and as directed.
M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length (RYB) in repair/maintenance of cables joints or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
Dismantling of old unsv solar street lights fittings alongwith galvanised steel pole and refixing the same after repair complete all as specified and directed. Note :- spare parts i.e solar lights/poles/panels/batteries reqd for repair to solar street lights paid and measured separetely.
Supply and fixing in replacement LED solar street light fiting 16 W including galvanised steel poles 6 Mtr in length in built lithium ion battery (having 3 days battery backup), solar panel, charge controller with dusk down sensor complete (excavation and earth work shall be measured and paid seperately) type 20 W 12 V DC outdoor type with decorative post top for 360 degre indirect light IP-65 protection with impact and corrosion resistant complete all fixing arrgangements complete all as specified and directed.
Supply and fixing in replacement LED solar street light fiting 20 W including galvanised steel poles 6 Mtr in length in built lithium ion battery (having 3 days battery backup), solar panel, charge controller with dusk down sensor complete (excavation and earth work shall be measured and paid seperately) type 20 W 12 V DC outdoor type with decorative post top for 360 degre indirect light IP-65 protection with impact and corrosion resistant complete all fixing arrgangements complete all as specified and directed.
S&F in replacement of solar batteries 40 to 60 AH, 12 Volts, complete with all reqd connection for functionig the existing solar lights complete all as specified and as directed .
Dismantling of old unsv solar batteries 40 to 60 AH, 12 Volts, complete with all reqd connection and refixing the same after repair for functionig the existing solar lights complete all as specified and as directed.
S&F in replacement of solar panel plages of capacity 60 Watt, 12 Volts polycrystalline solar panel complete all as specified and as directed .
S&F in replacement of solar street light 40 W led motion sensor, waterproof with 2750 luens and having a backup 20 hrs complete all as specified and directed.
S&F in replacement of solar street light 50 W led motion sensor, waterproof with 2750 luens and having a backup 20 hrs complete all as specified and directed.
M&L for repair /replacement of following accessories of high mast lights:-
Indicating light in Green, Red , Yellow
Terminal block up to 6 way
Combined multimeter voltmeter and ammeter
Selctor switch
Timer On/Off
Contractor with control cable of 1.0 Sqmm copper cable multistanded unsherthed (FRLS)
Control gear box with fitting with Winch double drum type having operating speed and gear ratio as per manufacturer design working manually / electrically alongwith stainless steel wire rope 6mm dia two point suspension system all as per manufacturer design upto 20 Mtr height with single phase motor of suitable size complete all as specified and directed
Lantern carriage ring suitable for 9X120W capacity
Lightning arrester spikes with earth wire/strip complete
Contactor 32 amps 4 pole
XLPE armoured Copper cable 10 sqmm 3.5 core
Supply & laying LT cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 Volts graded of cross section area :-
6 sqmm, 2 core.
4 sqmm, 2 core.
Supply & laying in replacement of PVC insulated armoured round sheathed copper conductor cable 4 sqmm size 12 core complete all as specified and directed
M&L in repair of stay assembly complete having stay rod 16/20mm dia with accessories as shown in electrical plate No. 1 (including loop type insulator, stay clamps) complete all as specified and directed. Note :- Excavation and concrete shall be measured and paid separately.
M&L in replacement of digital relay with over current/over voltage/earth fault protection for MRS panel as per sample complete all as specified and directed by Engr-in-charge
Material and labour in repair/replacement of following unserviceable accessories of 15 KVA three phase UPS, reinstalling the same at site with testing complete all as specified and directed :-
Rectifier of UPS
Invertor of UPS
Static by pass switch of UPS
Dry batteries (12 V 80 Ah)
Material and labour in repair/replacement of following unserviceable accessories of 20 KVA three phase UPS, reinstalling the same at site with testing complete all as specified and directed :-
Rectifier of UPS
Invertor of UPS
Static by pass switch of UPS
Maint free batteries (12 V 150 Ah)
M&L in Repair/maintenance of following spares parts of shadowless Operation Theater lights as per existing fittings and make complete all as specified and directed :-
Light Head
Cantiliver assembly
Mounting and fixing assembly
Cold light source filter
Cold light reflection mirror
Complete LED Dome as per existing model and make
M&L for topping up of graded course aggregate 20mm to 40 mm of nominal size in base of 2/4 pole (electrical poles) structure and electrical sub stations/panels etc complete all as speciried and directed.
Demolition of cement concrete (unreinforced) in ground floor & pavings n exc 15 cm thick below or above ground level complete all as specified and as directed.
Demolition of cement concrete in any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M/S Charan Singh and Sons
M/S M.A.S ELECTRICALS
M/S REDLY ENGINEERS
M/S Khan Hussain & Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .