| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.8 L+₹70,825 (1.44%)Rejected-Finance 1106 TIMES SQUARE ARCADE OPP RAMBAUG THALTEJ SHILAJ ROAD AHMEDABAD 380059 | AHMEDABAD | AHMEDABAD | GUJARAT | 380059 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹52.1 L+₹3.0 L (6.15%)Rejected-Finance MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN PARTICULAR CAT | |
| 5 | Rejected-Technical NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | - | Rejected-Technical NOT ENLISTED IN PARTICULAR CAT |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
10 Oct 2020, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE REPAIR MAINT OF MODERNISED INFRASTRUCTURE INCLUDING CERTAIN ALLIED WORKS AT AFS SULUR
2020_MES_377332_1
8357
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF SULUR
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
22 Oct 2020
14 Sept 2020
12 Oct 2020
14 Sept 2020
10 Oct 2020
28 Sept 2020
14 Sept 2020 - 26 Sept 2020
60 days
Amount
SCHEDULE A BOQ
Comprehensive maintenance including repairs but excluding defective componets /spare parts (However the rate for labour element is deemed to be included) as required for all the modernised infrastructure as described below under GE (AF) Sulur as follows:- (a) Servicing and maintenace /repair and replacement of defective components /spare parts of PLC based control panels including all accessories modem, antenna etc. installed at various pump houses, OHTs and Master control station for monitoring of water supply.
(b) Repair/maintenance by disconnecting connection for cleaning, lubricating, greasing for wear and tear complete servicing,refixing,lathing installing and commission as directed by Engr-in Charge of all motorised and solenoid valves, Pressure Switches, Ultrasonic and magnetic Level sensors, (c) Servicing and maintenace /repair of defective components of PLC based control panels including all accessories, modem, antenna etc. installed at various locations for the monitoring of street light circuits.. The scope of work also covers: (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of items covered under this AMC) (ii)Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of items covered under this AMC)
(iii) SCADA reports related to all the systems to be mailed to AGE/JE on every week (1) To attend break down maintenance and replacement of unservicable spare parts as required at site complete all as specified and directed by Engineer in charge Note : All components/spare parts replaced shall be measured and paid seperatly as supply only item mentioned in schedule ,fixing charges shall be deemed to be include in this item,nothing extra shall be admissible on this account. (2) All the calls related to unservicability/ break down of the system should be attend with in 8 hours, if failed to rectify the system within the stipulated time, a penalty @ Rs. 500 per day shall be deducted from the dues of the contractor. (3) The quoted rate shall also inclusive of 1 Engineer/ supervisor per day, minimum 2 Technician per day, Software Engineer one visit per month. If extra manpower is required for smooth functioning of mentioned system, rate for same deemed to be inclusive in quote rate. (4) All the charges for the communications, i.e. 01 Nos broad band connection with static IP at Kalpa Pump House and GPRS enabled data cards used in all PLC based panel related to this scope of work.
Comprehensive maintenance including repairs but excluding spare parts (However the rate for labour element is deemed to included) as required for all the modernised infrastructure under GE(AF) Sulur as follows
(a) Servicing and maintenace /repair and replacement of defective components /spare parts of PLC based control panels with all accessories modem, antenna complete with electrical connection panel installed at various locations for DG set control and monitoring. (b) Servicing and maintenace /repair and replacement of defective components /spare parts of PLC based control panels with all accessories modem, antenna complete with electrical connection panel installed at various locations for the monitoring of LT feeders. (c) Servicing and maintenace /repair and replacement of defective components /spare parts of AMR panel installed at various locations for the monitoring of Energy meters. The scope of work also covers : (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer of PLC based Panels only.
(ii)Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer/ Developer of SCADA only.The scope of work also covers:- (i) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of items covered under this AMC) (ii) SCADA reports related to all the systems should be mailed to AGE/JE on every week (1)To attend break down maintenance replacement of unservicable spare parts as required at site complete all as specified and directed by Engineer in charge Note (i) All components/spare parts replaced shall be measured and paid seperatly as supply only item mentioned in schedule ,fixing charges shall be deemed to be include in this item,nothing extra shall be admissible on this account. (2) All the calls related to unservicability/ break down of the system should be attend with in 8 hours, if failed to rectify the system within the stipulated time, a penalty @ Rs. 500 per day shall be deducted from the dues of the contractor. (3) The quoted rate shall also inclusive of minimum one Engineer/ supervisor per day, visit of software Engineer one visit per month. If extra manpower is required for smooth functioning of mentioned system, rate for same deemed to be inclusive in quote rate. (4) All the charges for the communications, GPRS enabled sim cards used in all PLC based panel related to this scope of work
Note for item Srl No 2 and 3:- (a). The servicing of Motorised valve, PLC base control Panels, communication Panels, shall be done by authorized representative of the Manufacturer only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him . (b) Any changes to the Programmable Logic Controller(PLC), e.g. Changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer (OEM) of PLC based Panels only. The programmer shall submit a letter from the manufacturer as proof of his being an authorized representative of the manufacturer. The programmer shall also submit a signed report on original letter head of the manufacturer (OEM) that servicing has been carried out by him.
(c) Any changes to the SCADA software, e.g. Changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized representative of the Manufacturer of PLC based Panels only. The technician shall submit a letter from the manufacturer as proof of his being a authorized representative of the manufacturer. The technician shall also submit a signed report on original letter head of the manufacturer that servicing has been carried out by him.
Comprehensive maintenance of CMDS including operation of CMDS equipments, data collection, assigning of task through concerned JE, updation of feed backs of services carried out, compiling of entries related to MES services from different sources, preparation of daily, weekly, monthly summary of services of different categories, submission of reports to concerned AGEs/GE as per laid down format complete all as directed. Note:- (a) The operator must have thorough knowledge in operation of computer and shall be smart enough to deal with customers of MES regarding registration, lodging, assigning of complaint of user to concerned JEs, updation of jobs/ complaints after carried out by the contractor on daily basis, etc. (b) Operator is responsible for compilation of user complaints in category wise like E&M, B&R & BS from different sources like manual registers, Wats App groups, CMDS lodged entries, etc and submission of report to concerned AGEs/ BSO weekly and monthly or as directed by GE. (c) In case of any failure in functioning of CMDS or task mentioned in above Para (a) & (b), a penalty @ Rs 500/- per day shall be deducted from the dues of the Contractor. (d) Contractor/ operator shall also be responsible to collect the completion/ update of work from concerned contractor/ JE and keep record of the same as directed. (e) The cost of stationery, printer and cartridge required shall be deemed to be incl in the quoted rate till the completion of the contract.
Supply only PLC (Programmable Logic Controller) complete all as specified and directed Make :Mitsubishi/SIEMENS/ or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only I/O module for Programmable Logic Controller complete all as specified and directed Make :Mitsubishi, Siemens or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only HMI for Programmable Logic Controller all as specified and directed Make :Mitsubishi, Siemens or existing make/brand of defective components/ spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Relay 24V DC with base complete all as specified and directed. Make : IDEC/Leone or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only water Level Controller PCB-10 Level complete all as specified and directed. Make: Splash/ICS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Pressure switch 0-10 Kg/sqcm complete all as specified and directed. Make : Danfoss/Indfoss or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Coil for Solenoid Valve 25mm 230 V AC complete all as specified and directed.Make: JOHNSON CONTROLSROTEX/AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MS spiral gear for gear box or actuator of 50 mm dia sizewith necessary gaskets, nuts, bolts and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Coil for Solenoid Valve 10 mm 230 V AC all as specified and directed.Make: JOHNSON CONTROLSROTEX/AVCON/DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Cast Aluminium Top cover for Actuator suitable for 50/80/100mm dia of Butterfly Valve complete all as specified and directed
Supply only Capacitor for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm bore of Motorized Butterfly Valve complete all as specified and directed
Supply of SMPS input 230 V/AC, Output 24V DC complete all as specified and directed. Make: NHP/TELEMEACHNIQUE or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only single phase Preventor complete all as specified and directed Make - Minilec or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only LED Indicator Colour/Red complete all as speicifed and directected. Make TELEMEACHNIQUE/ESBEE/TEKNIC or existing make/brand of defective components/ spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only key pad base HMI for Programmable Logic Controller complete all as specified and directed Make :Mitsubishi, Siemens or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Relay 24 V AC with base complete all as specified and directed : Make IDEC/Leone or existing make/brand of defective components/ spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only solenoid Valve 10mm 230VAC Complete all as specified and directed.Make: JOHNSON CONTROLSROTEX/ AVCON/ DANFOSS or existing make/ brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Magnetic Level switch complete all as specified and directed. Make: MAHALAXMI/ CRYSTAL or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Pressure gauge 0-100 Pascal complete all as specified and directed. Make Fiebag/Manometer or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Butterfly valve for 50 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Butterfly valve for 100 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Resistor for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm bore motorized Butterfly Valve complete all as specified and directed
Supply only Limit switch for Actuator suitable for 50 / 80 / 100 / 150 / 200 mm dia of motorized Butterfly Valve complete all as specified and directed
Supply, Installing, Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 meters, Accuracy : 0.5 % minimum Supply Voltage : 24V, DC Output : 4-20 MA complete all as specified and directed Make: BANNER/NIVELCO/VISIONTEK/MAESTRO/E+H/SIEMENS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only diesel Level Sensor complete all as specified and directed
Supply only power contactor 250 A 4P complete all as specified and directed Make: Schnider/Siemens/ABB/L&T or existing make/ brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr depth and n exc 1.5 mtr wide and getting out in soft/ loose all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25 Cms thick after laying and testing of cable complete all as specified.
Removing of excavated material to a distance not exceeding 50 meter and depositing where directed at level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
Supply only 2 core 1.5 sqmm armoured cable with copper conductor complete all as specified and directed Make : FSC/POLYCAB/FINOLEX/ PRIMECAB/DELTON and as approved by Engineer-in-Charge.
Supply only 4 core 1.5 sqmm armoured cable with copper conductor complete all as specified and directed Make : FSC/POLYCAB/FINOLEX/ PRIMECAB/DELTON or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only 6 core 1.5 sqmm armoured cable with copper conductor complete all as specified and directed Make : FSC/POLYCAB/FINOLEX/ PRIMECAB/DELTON or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only 5 pair 0.5sqmm armoured communication cable with copper conductor complete all as specified and directed.
Supply only joint kit complete all as specified and directed Make : Clip - Seal or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MCCB 4P 63 Amps, 25 KA with nuts, bolts, washers and lugs complete all as specified and directed. Make : L&T, ABB, Schneider
Supply only water Level Controller PCB-5 Level complete all as specified and directed. Make: Splash/ICS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only solenoid Valve 25mm, 230 V AC complete all as specified and directed. Make: JOHNSON CONTROLSROTEX/AVCON/ DANFOSS or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MS spiral gear for gear box or actuator of 100 mm dia sizewith necessary gaskets, nuts, bolts and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Electric motor suitable for actuator of 50/80/100mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MS spiral gear for gear box or actuator of 80 mm dia sizewith necessary gaskets, nuts, bolts and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Butterfly valve for 80 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Cast Aluminium Top cover for Actuator suitable for 150/200mm dia of Butterfly Valve complete all as specified and directed
G.I. tubing light grade 50mm bore for protection of cable under roads, crossings/culverts incl jointing at ends complete all as specified and directed Make: Prakash Surya/ Jindal/ Tata/ Ravindra and as approved by Engineer-in-Charge.
Comprehensive maintenance for SCADA severs:- a). At Kalpavihar: HP make CPU, LG make 40” monitor, Key board & mouse- HP make, HP Laser jet printer DLink broad band modem, DLink Ethernet switch b). Repair/ maint of any other hardware installed for monitoring of SCADA system also covered under this item. all as directed including necessary updation, antivirus etc. upkeep the service for the mentioned period.
Supply only MCB 2P 16Amps complete all as specified and directed
Supply only UPS 1 KVA UPS complete all as specified and directed Make : APC/TATA liebert/ Lumnious/ Numeric or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only UPS Battary complete all as specified and directed
Supply only LT CTs complete all as specified and directed
Supply only Electric motor suitable for actuator of 150mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MS spiral gear for gear box or actuator of 150 mm dia sizewith necessary gaskets, nuts, bolts and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Butterfly valve for 150 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Motorized actuator suitable for 50/ 80/ 100 mm bore of Butterfly valve complete all as specified and directed. Make: Hassel Hoffner/Rotork/ SD Tork/ Emerson or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Hand Wheel for Actuator suitable for 50/80/100 mm dia of Butterfly Valve complete all as specified and directed
Supply, Installation, Testing and Commissioning of GPRS communication Modem along with suitable external antenna, patch chord and mounting accessories. (i) GSM - Quadband (ii) GPRS - Class 10. (iii) Voice/Data/FAX/SMS facility (iv) TCP/IP - Full ( FTP & E Mail add) Functional Features (i) Input/output Digital -01 (ii) Down load over the air iii) At command set ( GSM 07.05, GSM 07.07 and Wave com)>300 (iv) Auto restore -time reset.
Voice ,Data and SMS Features (i) Data circuit synchronous , transparent and non transparent up to 14,400 bits (ii) Automatic tax group 3 ( class 1 & class 2) (iii) MNP @ V, 42 BIS (iv) Text & PDU SMS (v) Point to point SMS ( MT/MO) (vi) UC S2 character set management
(vii) Din rail mounting (viii) casing- Metal/plastic (ix) Operating status LED INTERFACES (i) SIM Plug in card reader - 1.813 V (ii) PS 232 on 15 Pin Sub.D connector (iii) Pin power supply connector -04 pin DC (iv) SMA Antenna connector Temp Range (i) Operating range - 20+55 degreec/ -25 to 70 degree C (ii) Power supply -5 to 32 V DC (iii) Protection Class-IP 55 (iv) Certification -CE Certification, GCG Certification, ROHS Compliance. (v) Programming /Parameterization 01 modem - Direct. Make: MOTOROLA / VISIONTEK /MAESTRO/ SOLPRO/ MARSH AUTOMATION/ INTEGRATED CONTROL SYSTEM
Supply only 9DB Antenna GPRS Modem complete all as specified and directed
Supply only Temprature Sensor complete all as specified and directed : Make: Existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MCB 4P 60Amps complete all as specied and directed.
Supply only Electric motor suitable for actuator of 200mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only MS spiral gear for gear box or actuator of 200 mm dia sizewith necessary gaskets, nuts, bolts and washers complete all as specified and directed. Make: Ritetork or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Butterfly valve for 200 mm bore with necessary gaskets, nuts, bolts,and washers complete all as specified and directed. Make L&T or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Motorized actuator suitable for 150 mm bore of Butterfly valve complete all as specified and directed. Make: Hassel Hoffner/Rotork/ SD Tork/ Emerson or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only single phase modbus compatible energymeter Module complete all as specified and directed : Make Adept or existing make/brand of defective components/spare parts or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only controller for AMF panel complete all as specified and directed Make: L&T/Siemens/ EPCOS/ GE/Crompton and Greaves or any reputed suitable make and as approved by Engineer-in-Charge.
Supply only Hand Wheel for Actuator suitable for 150/ 200mm dia of Butterfly Valve complete all as specified and directed
Supply, Installation, Testing and Commissioning of outdoor type power coated PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel made out of 1.6mm thick CRCA sheet for control and monitoring of 01 Nos Ultra Sonic Level Sensor, 02 Nos of motorised valves along with provision of arrangement for controlling of one more motorised valve as future expansion. The panel shall consist of the following equipments; (i) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC . (ii)4" LCD HMI (iii) Transformer with regulated output voltage of 230V +/-5%, (iv)SMPS of Suitable rating (v) Set of Control Relays and suitable MCB (vi) audio visual generator (vii) Suitable No. of LED Indicators for easy visualisation (vii) Selecetor Swtiches (ix) Push Buttons / Illuminated Push Buttons(x) 0.5 sq.mm multistrand internal wiring with ferruling and suitable lugs. (xi) Ethernet Card 6020 (xii)Media Converter (xiii)Ethernet Switch(xiv)LIU(Light Interface Unit)box patch chord and mounting accessories with following specification. Communication: Primary- OFC, Stand by: GPRS Make of Control Panel: RUBIX AUTOMATION / INTEGRATED CONTROL SYSTEMS /MARSH AUTOMATION
NOTE : The unit quoted rate shall be inclusive of the following :-
The cost of communication for a period of 12 months from the date of completion of work.
Creating additional screens in the existing SCADA system for monitoring and controlling the motorised valves.
Excavation , earth work , Provision of PCC plinth etc required for erection of panel
Supply and fixing 6F HDPE sheathed armoured uni-tube SM optical Fibre cable with central loose tube with jelly compound and high quality electro chromium coated corrugated steel type laid over head on existing available supports all as specified and directed Make : Polycab / Plaza / Havells.
Note :- Due to security reason, it will be the responsibility of the contractor to submit the list of labour i.e Site Engineer, Supervisor and killed labour before commencement of work to the Engineer-in Charge for police verification. Labour employed by the contractor against the work should carry photo identity card issued by the contractor.
CIMCON SOFTWARE INDIA PVT. LTD.
Kuriako Mathai and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .