Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.9 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹29.5 L+₹2.9 L (11.0%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹33.0 L+₹6.3 L (23.8%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | 4₹34.5 L+₹7.9 L (29.7%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | 5₹34.6 L+₹8.0 L (30.1%)Rejected-Finance | 5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIR / MAINT OF SUMMER APPLIANCES AND CERTAIN MISC AIR CONIDITIONING WORKS IN WEST WING TECH AREA AFS GWALIOR
2024_MES_683848_1
8900/1569/GWL/E8
Open Tender
Civil Works
Item Rate
270 days
GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹90,000
Yes
31 Dec 2024
14 Nov 2024
14 Dec 2024
14 Nov 2024
12 Dec 2024
28 Nov 2024
Amount
Disconnecting,dismantling and taking out the defective/ non functional desert cooler of any description and in any position and any location , strip opening of desert cooler, cleaning servicing oiling & greasing etc of desert cooler taking out and removing unserviceable/defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, reassembling & testing of the desert cooler complete all as specified and directed. Note :- (i) The replacement of defective/ nonfuctional parts shall be measured & paid separatly as ` supply only' under respective item of schedule A and fixing charges for new items are deemed to be included under quoted rate. (ii) The rate for above items are deemed to included for transportation to & from of vertical pumps/fan motor to workshop as approved by Engr-in-charge for necessary repairs, alignment and testing of pump and motor at workshop & replacement of necessary unserviceable screws/nuts, bolts/washer/packing etc with new one.
Supply only of the following parts for existing desert cooler of any description, any capacity, any make and in any position complete all as specified and directed. Note :- (i) Make of the parts must be same as per existing desert cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under respective item of schedule A here-in-before
15 mm dia PVC flexible water pipe complete set for one desert cooler
PVC distributor 3 way for 15 mm dia water distribution.
1.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade.
2.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade.
Regulator for three speed motor as per site requirement.
Submersible pump PVC body for desert cooler single phase, 230 volt AC flow rate 1100LPH, Max head 1850 mm Make:- Balaji or equivalent as approved
Desert Cooler evaporation panels (side and back panels) of any description and sizes for different size of desert coolers made to shape and size with using 20 SWG guage PGI sheets as per requirement incl necessary moulding etc to suit the existing desert cooler openings complete all as specified and directed as per site requirment.
Aluminium fan blade (set of three blades) for desert cooler motor of any description suitable for existing motor.
Wood wool pads of required size as apporved (three in each) for desert cooler of any size.
Desert cooler fan motor copper winding of existing make/model/ capacity/sweep, 900 RPM as per site requirement including making connection complete all as specified and directed Make - Crompton.
Desert cooler fan motor copper winding of existing make/model/ capacity/sweep, 1200 RPM as per site requirement including making connection complete all as specified and directed Make - Crompton.
Desert cooler fan motor copper winding of existing make/model/ capacity/sweep 1400 RPM (Exhaust fan kit with fan blade) including making connection complete all as specified and directed Make - Cromption
Chicken wire mess having hexagonal wire mesh (three for each cooler front and both side) 15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads of existing size suitable for any desert cooler.
Front grills of existing shape and size and made out of 20 SWG PGI sheet suitable for any desert cooler as required on site.
15mm bore ball brass valves high pressure with polythene float and fly nut complete
15mm bore Gun metal gate valve with iron wheel head, screwed both end for iron pipe Make NMC/BIR/Leader
PVC connection pipe 15mm size 450mm length complete with PTMT nuts on both ends.
5A plug top as per requirement, Make : Anchor or equavalent.
15 A plug top as per requirement, Make : Anchor or equavalent.
Disconnecting,dimanling and taking out the non functional Water Coolers of any description, any capacity to workshop cleaning , servicing, checking,replacement of unserviceable parts including testing to the entire satisfaction of Engineer - in - Charge complete all as specified and directed. Note :- Nut, bolts, screws are to be replaced and rates are inclusive under quoted rate, Labour for gas charging as required is inclusive under quoted rates . Replacement of new parts shall be measured and paid separately under relevant item of Sch 'A' as Supply only.
Supply only of the following parts for existing water cooler of any description, any capacity, any make and in any position complete all as specified and directed. Note :- (i) Make of the parts must be same as per existing water cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A here-in-before
Base tray stainless steel for 40 ltrs capacity
Base tray stainless steel for 60 ltrs capacity
Base tray stainless steel for 150 ltrs capacity
Side cover set of 3 stainless steel for 40/80 ltrs capacity
Side cover set of 3 stainless steel for 60/120 ltrs capacity
Side cover set of 3 stainless steel for 150/150 ltrs capacity
Water Reservior tank with chiller made of stainless steel incl copper tube for 40/80 Ltrs capacity
Water Reservior tank with chiller made of stainless steel incl copper tube for 60/120 Ltrs capacity
Water Reservior tank with chiller made of stainless steel incl copper tube for 150/150 Ltrs capacity
Water tank chiller's top cover made of stainless steel for 40/80 ltrs capacity
Water tank chiller's top cover made of stainless steel for 60/120 ltrs capacity
Water tank chiller's top cover made of stainless steel for 150/150 ltrs capacity
Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 40/80 ltrs capacity
Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 60/120 ltrs capacity
Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 150/150 ltrs capacity
Relay unit currrent type suitable for 40 to 150 Ltr Cap water cooler as per existing make and model.
Relay pin type (Potential type) suitable for 40 to 150 Ltr Capacity water cooler as per existing Make and Model.
Thermostat 220 volts suitable for 40 to 150 Ltr as per existing make and model
Over load protector of existing make suitable for 40 to 150 Ltr water cooler
AC electric condenser motor as per existing make and model suitable for 40 Ltr water Cooler.
AC electric condenser motor as per existing make and model suitable for 60 Ltr water Cooler.
AC electric condenser motor as per existing make and model suitable for 150 Ltr water Cooler.
Brass nipple 15 mm dia for inlet and out let connection of water cooler any type/size incl PVC connection 15 mm dia with brass coupling on both ends
Drain pipe PVC flexible ¼" dia .
End circle clip for Drain pipe 1/4" dia
Flexible Wiring kit of PVC insulated copper condutor cable of existing size.
CP brass push cock 15mm dia (ISI marked) inner/outer threaded as directed
Harmetic sealed unit compresssor of existing make and model suitable for capcity 40/80 Ltrs of water cooler incl vaccum testing and filling of refrigerant gas to required pressure is included under relavent item of Sch 'A' complete all as directed by Engineer - in - Charge.
Harmetic sealed unit compresssor of existing make and model suitable for capcity 60/120 Ltrs of water cooler incl vaccum testing and filling of refrigerant gas to required pressure is included under relavent item of Sch 'A' complete all as directed by Engineer - in - Charge.
Harmetic sealed unit compresssor of existing make and model suitable for capcity 150/150 Ltrs of water cooler incl vaccum testing and filling of refrigerant gas to required pressure is included under relavent item of Sch 'A' complete all as directed by Engineer - in - Charge. Note : The cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under respective item of schedule 'A'.
Fan blade suitable for 40/80 ltrs capacity
Fan blade suitale for 60/120 ltrs capacity
Fan blade suitable for 150/150 ltr capacity
Disconnecting,dimanling and taking out the non functional Refrigerator of capacity 165 to 340 ltrs of any description, Servicing , checking,replacement of unserviceable parts including testing complete all as specified and directed. Note :- Replacement of new parts and shall be measured and paid separately under relevant item of Sch 'A' as Supply only.
Supply only of the following new parts for existing refrigerator of any description, any capacity of 165 to 340 ltrs & any make and in any position complete all as specified and directed.
Main door gasket magnetic type
Thermostat switch with knob 230 volt suitable for single door refrigerator
Thermostate switch with knob 230 volts suitable for double door refrigerator of capacity 165 to 360 ltrs
Overload relay suitable for referigerator of capacity 165 to 340 Ltr Capacity as per existing Model.
Freezer Zone door suitable for existing make and Model.
Pin type/screw type bulb Make Philip/bajaj/Crompton
Condensor water drain off tray of pvc same as per existing model complete
Door switch 230 volts
Chiller tray plastic suitable for 165 to 340 Ltr Capacity.
Refrigerator freezer coil suitable for as per existing for 165 ltr to 230 ltrs capacity
Refrigerator freezer coil suitable for as per existing for above 230 ltr to 360 ltrs capacity
Bulb holder assembly complete
Inner PUF Insulation for 165 to 230 ltr capacity
Innter PUF Insulation for above 230 ltr to 360 ltr capacity
PVC inner cabinet moulded in shape suitable for capacity 165 to 230 ltrs
Condesner coil for 165 to 230 ltrs capacity
Condesner coil for above 230 to 360 ltrs capacity
Fan motor suitable for double door refrigerator as per existing.
Thermostat suitable for referigerator of capacity 165 to 230 ltr as existing
Thermostat suitable for referigerator of capacity above 230 and upto 360 ltr as existing
PCB for 165 to 230 ltrs capacity as per existing Make and Model
PCB for above 230 to 360 ltrs capacity as per existing Make and Model
Timer for double door refrigerator as per existing make.
Capilary suitable for referigerator of Capacity 165 to 360 ltr as per existing
Sealed unit compressor suitable for referigerator of capacity 165 Ltr to 230 Ltr as per existing Make and Model incl vacuum testing and filling of refrigerant gas to the required pressure complete to the entire satisfaction of Engr - in - Charge , Gas charging, brazing to suction and discharge line is included relevant item of Sch 'A'.
Sealed unit compressor suitable for referigerator of capacity above 230 Ltr to 360 Ltr as per existing Make and Model incl vacuum testing and filling of refrigerant gas to the required pressure complete to the entire satisfaction of Engr - in - Charge , Gas charging, brazing to suction and discharge line is included in relevant item of Sch 'A' .
Vegetable tray of refrigerator suitable for capacity 165 to 360 Ltr Capacity.
Supply of Refrigerant gas (R-134A) in cane complete all as specified and directed.
Supply of Refrigerant gas (R-600A) in cane complete all as specified and directed.
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed
Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed
S&F PVC insulated & sheathed copper round cable 1100 volts of size 4.0 sqmm 3 core incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed.
All as per item No 10 here-in-before but of Size 4.0 sqmm 4 core
All as per item No 10here-in-before but of Size 4.0 sqmm 5 core
Preventive maintenance & routine servicing of split AC of any type/size/make /model & capacity up to 3TR in any position / work shop as convenient indoor & out door unit by cleaning of dust from condenser,air filter, cooling coils by pressure pump , liquid line filter/capillary tube /expansion valve, refrigerent inlet /out let pipe by Nitrogen and Ethylene tri chloride(ETC),and checking of all electrical components and compressor etc. Replacement of minor parts such as nut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed. Note:- (i) Contractor has to provide sufficient manpower minimum 02 Technician and 04 helper for resolving timely complaints. (ii) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.
Preventive maintenance & routine servicing of Window type AC of any type/size/make /model & capacity at any position including cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers incl replacment of unserviceable parts of capacity 1.5/2.0 TR of single phase AC etc and testing complete all as specified and directed. NOTE :- (i) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit.
Supply only following items of Air conditioning split/window type AC of capacity 1.5/2/3TR of any make/model/ capacity including checking of defects and rectified complete all as specified and directed .
Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC supply.
Supply only in replacement with new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply
Supply only in replacement with new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ AC supply
Supply only in replacement with new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply
Supply only in replacement with new Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC supply
Supply only in replacement with new Running capcitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC supply
Supply only in replacement with new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC supply
Supply only in replacement with new PVC braded drain pipe of size 15 mm inner dia
Supply only in replacement with new PVC braded drain pipe of size 20 mm inner dia
Supply only in replacement with new PVC braded drain pipe of size 30 mm inner dia
Supply only in replacement with new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unit suitable for Split AC/Window AC 1.5/2.0 TR of capacity, model and make as per existing all as directed.
Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR inverter type of capacity, model and make as per existing all as directed.
Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR capacity Non inverter type, model and make as per existing all as directed.
Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for Split AC 3.0 TR cassete type of any model and make as per existing all as directed.
Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB and display unit suitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing all as directed.
Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR complete all as specified and directed.
Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR complete all as specified and directed.
Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 3TR complete all as specified and directed.
Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type Cassete AC 3TR including complete all as specified and directed.
Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site
Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site
Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Single Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site
Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Three Phase complete all as specified and directed at site. Make :- LG/Blue star/ Voltas or as per existing make of AC at site
Supply only in replacement with new capillary tube of size as per sample suitable for split AC 1.5TR/2TR/3TR and window type AC of any make complete all as specified and directed.
Supply only in replacement with new Liquid line copper filter as per sample suitable for 1.5/2 TR split/window AC.
Supply only in replacement with new Liquid line copper filter as per sample suitable 3 TR split AC.
Supply only in replacement with new Over load Relay as per sample suitable for any type split type 1.5/2 TR Capacity.
Supply only in replacement with new Over load Relay as per sample suitable for any type split type 3 TR Capacity.
Supply only in replacement with new Condenser side fan blade as per sample suitable for existing Split type AC's of Capacity 1.5/2 TR.
Supply only in replacement with new Condenser side fan blade as per sample suitable for existing Split type AC's of Capacity 3 TR.
Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split AC's any make as existing.
Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5 /2 TR Capacity as per existing make and model.
Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TR Capacity as per existing make and model.
Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5/2 TR capacity inverter type as per existing make and model.
Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TR capacity inverter type as per existing make and model.
Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 1.5 / 2 TR Capacity.
Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 3 TR Capacity.
Supply only in replacement with new flapper suitable for Split AC as per sample for capacity 1.5 to 3 TR
Supply only in replacement with new PVC Grills as per sample and for any make window AC.
Supply only in replacement with new Thermostate switch with knob 230 volts for Window AC
Supply only in replacement with new Check valve any dia for upto 3 TR capacity Split AC's as per sample.
Supply only in replacement with new Expansion valve complete set as per sample suitable for 1.5 / 2 TR Spllit AC.
Supply only in replacement with new Expansion valve complete set as per sample suitable for 3 TR Spllit AC.
Supply only in replacement with new Ventury as per sample made of thermo-coal insulation suitable for Window AC .
Supply only in replacement with new Pre-air filter made up of PVC for indoor unit as per sample of split AC suitable for any capacity make and description complete
Supply only in replacement with new Brass service valve of 5/8" dia with flare unit as per sample for split type AC.
Supply only in replacement with new Brass service valve of 3/8" dia with flare unit as per sample for split type AC.
Supply only in replacement with new Brass service valve of 1/2" dia with flare unit as per sample for split type AC.
Supply only in replacement with new Brass service valve of 1/4" dia with flare unit as per sample for split type AC.
Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacity and reassembling, fixing and testing the dismantled AC in new location / position after making necessary cutting/opening and making good in window frame complete all as specified and directed. Note- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge (ii) Gas for charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A'.
Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase and reassembling, fixing and testing incl installation of split / window AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing's etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge. (ii) Gas for charging of gas if required shall be measured and paid seperatly under appropriate item of schedule A
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 3/8" bore
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 5/8" bore
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/4" bore
Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/2" bore
Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed.
Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 3 TR split AC complete all as specified and directed .
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample complete suitable for 1.5 TR Split Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A'
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 2 TR Split Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A'
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 3 TR Split AC Single Phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A' .
Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per sample complete all as directed and suitable for 2 TR Single Phase Window Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A'
Supply and fixing in replacement with new Rotary compressor as per sample complete and suitable for 1.5 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A'
Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed and suitable for 2 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A'
Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed and suitable for 3 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A'
Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch 'A' .and suitable for 3 TR Split AC Three phase 230 volts of existing make.
S&F in replacement with new out door cover at any location and floor made of MS Angle and GI Sheet with proper fixing screw to cover the entire out door unit as per sample , fixed on wall with neccessory grouting MS bolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed.
Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB.
S & F in replacement with new Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps.
Supply and fixing in replacement with new 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing in replacement with new SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing in replacement with new TPN / FP 32 Amp 415V 10KA 'B' curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fixing in replacement with new power contactor MNX-12 of rating 12 amps four pole suitable for 415 volts for AC.
S&F in replacement with new contactor MNX18 Amp rating 18 Amps suitable for 220 Volts with 1 NO+1NC auxilary contacts complete all as specified and directed.
S&F in replacement with new contactor MNX 40 Amp rating 40 Amps suitable for 220 Volts with 1 NO+1NC auxilary contacts complete all as specified and directed
M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed.
S&F in in replacement with new electronic timer including testing time range from 3 seconds to 120 seconds suitable for 240/415 volts 50 HZ complete all as specified and directed
S & F in repair Voltage Monitor three phase protection device for three phase system having protection against High, Low Voltage , Single Phasing and Reverse phase sequence as per sample Make : Voltas or equavalent.
Repair / Maint of PCB of any type AC as per Sample suitable for 1.5 / 2/ 3 TR split / window AC complete all as specified and directed by Engr - in - Charge.
M/s Shanti Enterprises (BID ID -3187090)
Uma engineers (BID ID -3181307)
GUPTA ENGINEERING WORKS (BID ID -3187553)
M/S Rakesh Verma (BID ID -3187088)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .