| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.9 L+₹2.0 L (5.22%)Rejected-Finance | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹40.1 L+₹2.2 L (5.87%)Rejected-Finance | L3 | Rejected-Finance Higher than L1 | |
| 4 | L4₹40.7 L+₹2.8 L (7.50%)Rejected-Finance | L4 | Rejected-Finance Higher than L1 | |
| 5 | L5₹41.3 L+₹3.4 L (9.06%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance Higher than L1 |
| Sl No | Description | Qty | Unit | M/s Singla Trading Comapny L1 | KHANNA CONSTRUCTIONS L5 | Dashmesh Construction Company L4 | J and P CONTRACTOR L2 | MANVEER ENERGY L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling wall and ceiling board (fibre, pulp, insulation ,etc.) or insulation boards/panels/blankets, any thickness, including cover fillets complete all as specified and directed. | 240 | Sqm | 20 ₹4,800 Lowest | 28 ₹6,720 | 50 ₹12,000 | 30 ₹7,200 | 70 ₹16,800 |
| 2.00 | S & F Solid PVC Wall Lining consisting of 5mm thick wood grain printed (one side) PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
Note : Colour of paneling will be approved by GE /Engr-in-charge | 100 | Sqm | 1,360 ₹1,36,000 | 1,320 ₹1,32,000 | 1,200 ₹1,20,000 | 1,100 ₹1,10,000 Lowest | 2,000 ₹2,00,000 |
| 3.00 | S & F for 5mm thick laminated one side with wood grain printed sheet fillet of width 35mm for wall paneling frame work inclusive of fixing on to wall to make PVC Frame as per specification and draw-ing complete all as specified and directed. Note : - Colour of panneling will be decided by GE/ Engr-in-charge. | 200 | RM | 85 ₹17,000 | 95 ₹19,000 | 75 ₹15,000 | 30 ₹6,000 Lowest | 100 ₹20,000 |
| 4.00 | S&F Hangers 3mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long as in hook and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. | 110 | Sqm | 120 ₹13,200 | 50 ₹5,500 Lowest | 300 ₹33,000 | 200 ₹22,000 | 100 ₹11,000 |
| 5.00 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. | 110 | Sqm | 580 ₹63,800 | 580 ₹63,800 | 450 ₹49,500 | 300 ₹33,000 Lowest | 300 ₹33,000 Lowest |
| 6.00 | Providing and fixing 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with ellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. (Note :- Design of ceiling approved by GE ) | 110 | Sqm | 520 ₹57,200 | 450 ₹49,500 Lowest | 650 ₹71,500 | 1,500 ₹1,65,000 | 600 ₹66,000 |
| 7.00 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing rubbish from the site complete all as specified and directed. | 18 | Cum | 250 ₹4,500 Lowest | 500 ₹9,000 | 500 ₹9,000 | 400 ₹7,200 | 500 ₹9,000 |
| 8.00 | Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab as described below by any one method complete as per manufacturers instructions and directions of GE :- | 30 | Sqm | 750 ₹22,500 | 740 ₹22,200 Lowest | 750 ₹22,500 | 1,500 ₹45,000 | 1,000 ₹30,000 |
| 8.01Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment. | ||||||||
| 8.02Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment. | ||||||||
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
23 Jun 2026, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
CERTAIN B/R REPAIRS AND MAINT UNDER AGE B/R-I OF GE SGNR AT MIL STN SGNR
2026_MES_769156_1
GE SGNR/TOK-04 OF 2026-27
Open Tender
Civil Works
Item Rate
270 days
Sri Ganganagar(Raj)
D Class a(i) and for un-enlisted, refer NIT para 8
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹80,000
Yes
10 Jul 2026
2 Jun 2026
25 Jun 2026
2 Jun 2026
23 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling wall and ceiling board (fibre, pulp, insulation ,etc.) or insulation boards/panels/blankets, any thickness, including cover fillets complete all as specified and directed. | 240 | Sqm | - | - |
| 2 | S & F Solid PVC Wall Lining consisting of 5mm thick wood grain printed (one side) PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
Note : Colour of paneling will be approved by GE /Engr-in-charge | 100 | Sqm | - | - |
| 3 | S & F for 5mm thick laminated one side with wood grain printed sheet fillet of width 35mm for wall paneling frame work inclusive of fixing on to wall to make PVC Frame as per specification and draw-ing complete all as specified and directed. Note : - Colour of panneling will be decided by GE/ Engr-in-charge. | 200 | RM | - | - |
| 4 | S&F Hangers 3mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long as in hook and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. | 110 | Sqm | - | - |
| 5 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. | 110 | Sqm | - | - |
| 6 | Providing and fixing 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with ellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed. (Note :- Design of ceiling approved by GE ) | 110 | Sqm | - | - |
| 7 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing rubbish from the site complete all as specified and directed. | 18 | Cum | - | - |
| 8 | Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab as described below by any one method complete as per manufacturers instructions and directions of GE :- | 30 | Sqm | - | - |
| 8.01 | Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment. | - | - | - | - |
| 8.02 | Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_861362.xls
BOQ • 1.55 MB
GenPage1.pdf
Tender Documents • 0.86 MB
GenPage2.pdf
Additional Documents • 0.72 MB
Amd2.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .