| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.4 L+₹1.7 L (7.61%)Rejected-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹23.6 L+₹1.8 L (8.12%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-AOC Not Being L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Feb 2024, 6:00 pmClosed
Garrison Engineer, Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai
REPAIR AND REPLACEMENT OF EXTERNAL ELECTRIFICATION AND ALLIED SERVICES AT AF TECH AREA, DOMESTIC AREA AND OD TECHNICAL AREA DOMESTIC AREA, MH OTD P/H, ASC BUTCHERY, FURNITURE YARD UNDER GE AVADI
2024_MES_637046_1
8168
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer, Avadi
₹80,000
Yes
19 Mar 2024
11 Jan 2024
20 Feb 2024
11 Jan 2024
12 Feb 2024
27 Jan 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning, filling in, with soil obtained from excavation including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches Fine seived excavated dry soil including spreading / leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B of size 230x115x75mm for cable protection all as specified and as directed.
Laying only XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5 / 4 of the following sizes cross-sectionl area including taking down of old unserviceable cable complete all as specified and as directed:- Note : All size of LT UG cables will be issued by the department under schedule ''B" for free for fixing. Transportation of LT UG cable from store yard to work site to be in and included in quoted rate by the contractor.Earth work including excavation ,returning Filling,removing,soil coushioning,brick covering for mechanical protection of cable etc will be measured and paid separately under respective items of schedule.
16 sq mm 2 core
16 sq mm 4 core
35 sq mm 3.5 core
50 sq mm 3.5 core
70 sq mm 3.5 core
95 sq mm 3.5 Core
120 sq mm 3.5 Core
185 sq mm 3.5 Core
Finding and rectification of electrical fault by checking of external/internal(LT) elect supply feeder, street light feeder,under ground cables using elect tools, equipments and safty devices after arranging elect shut down of feeders from sub station to remove elect faults like tightning of loose connection,removing of any electric short,meggring of cable,excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightning of cable lugs etc all as required at site complete all as specified and as directed. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices. (ii) Any major materials used for rectification of faults like Cables,MCB/MCCB of any size/type etc will be measured and paid seperately . (iii) Rate including hiring of fault finding equipments and Earth Work. (iv) Works should be completed with in 03 hrs
Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of following sizes : Note: Earth work including excavation ,returning Filling,removing,sand coushioning,brick covering for mechanical protection of cable and Jointing Kit will be measured and paid separately under relevant Item.
(a) LT UG Cable 3.5/ 4 core 25 Sqmm to 3.5 core 50 Sqmm
(b) LT UG Cable 3.5 core 70 Sqmm to 3.5 core 120 Sqmm
(c ) LT UG Cable 3.5 core 150 Sqmm to 3.5 core 185 Sqmm
Supply and Fixing of Straight through joints heat shrink type for underground cable suitable for LT XLPE/ PVC sheathed/ armoured heavy duty cables with aluminium conductor all as specified and as directed of following sizes:-,
3.5/ 4 core, 25 sqmm to 50 sqmm
3.5/ 4 core, 70 sqmm to 120 sqmm
3.5/ 4 core, 150 sqmm to 185 sqmm
Supply and errectioning of ACSR conductor of any size for LT over head line and jumpers on PCC/RCC/Steel pole including binding wires line connecting up etc of any size including taking down the old unserviceable one complete all as specified and as directed .
Material and labour for Cross arms bracing supports clamps and back pates fabricated from structural steel sections including nuts, bolts, washers, welding ,bending, cold or hot drilling holes for insert bolts in any shape or size as indicated and as directed and inclusive of one coat of redoxide primer and one finishing coat of aluminium paint including taking down old unserviceable one complete all as specified and as directed.
Material and labour for Shackle type porcelain vitreous white, brown or green insulator in replacement having working pressure 1100 Volts of 90mm dia 75mm height including galvanized mild steel strip of size 31x3mm ,size 12mm dia insulator nuts, bolt and washers including taking down old unserviceable one complete all as specified and as directed.
Material and labour for Pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 Volts grade including taking down old unserviceable one complete all as specified and as directed.
Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- Make of MCCB: Havells,L&T,C&S or Equvalent (i) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 Nos. Note : MCCB shall be front handle operated.
Material and labour for 1100 volts grade heavy duty cable PVC insulated , PVC sheathed , fire resistant, round ,copper conductor, 3 core industrial cable of size 1.50 sqmm including taking down the old one complete all as specified and as directed. Make: Havells,Paragon,Gloster or Equvalent
All asper Item No 15 above but of size 2.50 sqmm including taking down the old one complete all as specified and as directed. Make: Havells,Paragon,Gloster or Equvalent
Repair and welding work the existing panel board door with provision of new door by taking down the old rusted door and provided hinges for door, if necessary and lock arrangement with provision of suitable size of sliding bolt and cleaning the welding surfaces by rubbing and polishing with two coat of synthetic enamel paint to match with existing colour all as specified and as directed.
Repair to the existing LT panel board with provision of new lugs,bolt , nuts and washers suitable for size of cable from 4/3.5 core x 10 Sqmm to 240 Sqmm by taking down the old burnt/rusted lugs, bolts , nuts and washers in necessary quantity as per site requirment including cleaning the busbars, provision of insulation sleeves to busbars where ever required complete all as specified and as directed.
Material and labour for GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of following sizes including taking down old unserviceable one complete all as specified and as directed. Make: TATA,Jindal(Hissar),Kalinga or Equvalent.
(a) Bore of tube 25mm
(b) Bore of tube 40mm
(c ) Bore of tube 50mm
Material and Labour for preparation of old painted surfaces ,removing dust and other deposited materials by scraping from LT panel inner and outer surface of front and rear doors including all compartment of MCCBs,busbar chamber,cable tray etc with one coat of same existing colour synthetic enamel paint by means of spray gun complete all as specified and as directed.
Material and Labour for preparation of old painted surfaces ,removing dust and other deposited materials by scraping from busbar chamber inner and outer surface of front and rear doors including compartment of MCCB,busbar chamber with one coat of same existing colour synthetic enamel paint by means of spray gun complete all as specified and as directed.
Material and Labour for preparation of old painted surfaces ,removing dust and other deposited materials by scraping from LT tubular pole of 7.5 Mtr long above ground level , painting of pole with one coat of black paint upto 1 Mtr from bottom and painting the rest of the pole with one coat of aluminium paint including cross arms cable protection pipe clamps etc , including writing the MES No with white paint over black band of paint at a level of 1.2 m above ground level on each pole complete all as specified and as directed.
Material and Labour for preparation of old surface of PCC electric pole 7.5 m long above ground level applying two coats of cement based paint on pole and painting two coats with aluminium paint on cross arms, clamps, etc, including writing the MES No with white paint over black band of paint at a level of 1.2 m above ground level on each pole complete all as specified and directed.
Material and Labour for MCCB 160 amps ,4 pole 415 volts ,3 phase ,50 Hz AC with adjustable thermal setting & 36 KA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 36 KA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer including taking down old unserviceable one complete all as specified and as directed. Make : Havells,L&T,C&S or Equvalent
All as per Item No 24 above but of capacity 200 amps including taking down old unserviceable one complete all as specified and as directed.Make : Havells,L&T,C&S or Equvalent
All as per Item No 24 above but of capacity 250 amps including taking down old unserviceable one complete all as specified and as directed. Make : Havells,L&T,C&S or Equvalent
All as per Item No 24 above but of capacity 400 amps including taking down old unserviceable one complete all as specified and as directed. Make : Havells,L&T,C&S or Equvalent
Supply and Fixing of LED street light fitting,230 V,AC, 45 W, LED, outdoor type,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 65/ 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed .
Supply and Fixing of LED street light fitting,230 V,AC, 60 W, LED, outdoor type,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 65/ 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed.
Supply and Fixing of LED flood light fitting,230 V,AC, 120 W, LED, outdoor type,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed .
Supply and Fixing of LED post top lantern,230 V,AC, 40 W, LED, outdoor type,360 degree indirect light,CCT not less 6000K high pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 65 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED with driver,lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete fixed on existing / New bracket and making connections including taking down the old one complete all as specified and as directed .
Supply and Fixing MCB,240V,10KA,'B' curve,single pole,current carrying capacity 5Amps, suitable for fixing in SMC box for control street/flood lights and making connections including taking down the old one complete all as specified and as directed . Make : Havells,L&T,C&S or Equvalent
Supply and Fixing of pole mounted Sheet Moulded Compound(SMC) Box weather proof type with hinged type door off white color of size 380x225x140 mm for 3 phase comprising of 1 No MCB 6A and suitable size 3 No bakelite base Phase link,1 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs complete fixed on pole with suitable clamps, bolts and nuts including taking down the old one complete all as specified and as directed. Make : Sintex,Finolex, Universal or Equvalent
Cutting/clearing and removing the vegetation/bush/creepers growth any nature/type around/on the electric panel/feeder pillar box/busbar chamber so as to keep clean the area for easy access to carry out repair/maintenance works in electric panel/feeder pillar box/busbar chamber etc, removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.
Material and Labour for plain cement concrete1:3:6 using, type C1 20mm graded stone aggregate for coping of pole including demolition of old concrete form work and complete all as specified and as directed.
Material and labour for LED Driver, AC, 85 to 265 Volts range, suitable for 45 watts street light including taking down the old one complete all as specified and as directed.
Material and labour for LED Driver, AC, 85 to 265 Volts range, suitable for 60 watts street light including taking down the old one complete all as specified and as directed.
Material and labour for LED Driver, AC, 85 to 265 Volts range, suitable for 120 watts street light including taking down the old one complete all as specified and as directed.
Pruning of tree branches and making clear HT line to the minimum distance of 30 mtrs span for 3/6 conductors and removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.
Supply and fixing Indicator lamp of any type / model / capacity in LT panels panels including taking down old unserviceable one complete all as specified and as directed.
Supply and fixing Multifunction meter with RS port of any type / model / capacity in LT panels including taking down old unserviceable one complete all as specified and as directed.
muthu constructions
PSK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .