| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹12.0 L+₹25,805 (2.20%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹12.4 L+₹64,270 (5.48%)Rejected-Finance 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹12.9 L+₹1.2 L (10.4%)Rejected-Finance ATAL JI KI GALI SHINDE KI CHHAWANI LASHKAR GWALIOR MADHYA PRADESH 474009 | GWALIOR | MADHYA PRADESH | 474009 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹13.6 L+₹1.9 L (16.1%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
2 Dec 2020, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (MES) DANAPUR CANTT
PROVEN OF SECURITY LIGHT WITH POLES AT MANEKSHAW SPORTS COMPLEX IN AGE EM UNDER GE DANAPUR CANTT
2020_MES_392498_1
GE/DNR/T-57 OF 2020-21 / 8436/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER
₹29,000
18 Dec 2020
4 Nov 2020
5 Dec 2020
4 Nov 2020
2 Dec 2020
18 Nov 2020
4 Nov 2020 - 17 Nov 2020
Amount
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated,FRLS screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 25 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed. (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this BoQ ).
All as per ser item No 1 above but of cross sectional area 10 sqmm 4.0 core complete as specified and directed
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and directed.
Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. Note :- Thickness of sand shall be measured 18 mm thick after punning of sand
Supply and laying sub class B bricks of size 25cmx15cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and directed.
M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting 40 mm bore GI pipe all complete all as specified and directed. (Note :- GI pipe will be measured and paid respective item of BoQ).
M & L for PCC work providing PCC type B2 (1 : 2 : 4) with 40 mm graded aggregate in foundation for pole foundation/coping and finishing the surface even and smooth without using extra cement complete as specified and directed.
M & L for PCC work providing PCC type C2 (1 : 3 : 6) with 40 mm graded aggregate in foundation for pole foundation and finishing the surface even and smooth without using extra cement complete as specified and directed.
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts and screw as specified, type 410 SP-55, 11 Metre long including painting all external exposed steel surfaces with two coats of aluminium paint over a coat of red oxide zinc chrome primer and all internal surfaces & external surfaces in contract with concrete with two coats of black bituminous paint and painting of bottom portion of the pole upto 0.75m from top of the copping with two coat of synthetic enamel paint over a coat of red oxide primer and writing pole no with synthetic enamel white paint on black colour circle of suitable size complete all as specified and directed. (Note: Excavation & Earth work and PCC foundation/base shall be measured and paid separately under relevant items of this Sxhedule 'A')
M & L for cross arms, bracing clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size complete with welding, binding, two coats of aluminium paint over a coat of primer for fixing flood lights complete all as specified and directed.
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 32x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 40 mm bore (Medium grade) for LT panel/FPB complete all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all as specified and directed.
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised Iron 4.00 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Medium grade) for poles/panel including connecting to pole all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all as specified and directed.
Supply and fixing LED flood light luminaires 200 Watts IP 66 type with lens incl standard fittings pressure die cast aluminium housing with heat reistant toughened front glass housing with epoxy powder coated finsh and complete with control gear box and all accessories duly prewired and connecting to junction box and testing including three years on site warranty from manufacturer complete all as specified and directed. (Make : Bajaj, Cat No: BARFEG 200W LED/ Crompton Greaves, Cat No: LSFO-200-CDL/60 or equivalent model of Havells/Philips).
Supply and fixing pole mounted junction box/bus bar chamber for loop connection of street light cable of size 295x195x100 mm with 63 amps aluminium busbar wrapped with PVC sleeves and maintained the colour code and provision of making holes with GI nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and suitable arrangement for fixing one no MCB complete all as specified and directed. Make: Sintex , Cat No: GSJB3020 or equivalent model of Hensel/Rittel.
S&F MCB, Single pole, 6 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and directed (Make : Legrand/ Hager/ABB/Siemens).
M&L for one run of 1.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed. Make : Plaza/MESCAB/Polycab/Havell's.
Supply, erection, testing and commissioning KIOSK outdoor type LT feeder pillar box of minimum size 900mm(height) x 600mm (breath) x 500mm (depth) platform mounted, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos copper bus bar for distribution system and type tested at CPRI fabricated .The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, double door front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel angle iron legs of minimum size angle iron 25x3 mm . The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947 and including complete internal wiring with 1.5 sqmm copper wire and copper strip/wire from busbar to MCB input and MCB to cable connector of suitable length including PCC (1:3:6) type C-2 as in foundation of suitable size (30 cm below ground level & 40 cm above ground level) including necessary excavation and earth work complete all as specified and directed alongwith comprising of the following accessories :-
NOTE: Rate of earthwork and PCC are deemed to be inclusive in this item.embedded in PCC foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed comprising of the following fitment accessories :
BUS BARS AND INTERNAL CONNECTIONS :The bus bars shall be made of Copper strip ,63 Amps rated of minimum length 450 mm wrapped with PVC sleeves and maintained the colour code and provision of making holes with copper nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar - 04 Nos
Incoming (a) MCCB 4 pole 415 volts 50 Hz adjustable thermal magnetic release of rating 63 Amps having breaking capacity 25 KA - 01 No (Make : Legrand/Siemens/L&T)
(c) LED Pilot Lamp (for Incomers) suitable for 230/240 Volts AC supply complete with integral circuit & cluster LED of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (Make : Legrand/Siemens/L&T)
Outgoing (a) MCB TPN of rating 32 Amps having breaking capacity 10 KA - 03 Nos (Make : Legrand/Siemens/L&T).
(b) MCB SPN of rating 25 Amps having breaking capacity 10 KA - 02 Nos (L&T/Legrand/Siemens)
(b) Spare pocket for 01 Nos MCB.
AAY JAY ENTERPRISE
M/s KUMAR ENTERPRISES
RAJ AND SONS
Rama Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .