Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹12.3 L+₹2.4 L (24.7%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹13.8 L+₹3.9 L (39.6%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹16.3 L+₹6.4 L (64.7%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹17.0 L+₹7.1 L (71.8%)Rejected-Finance CHHANI NANAK TEHSIL MANDAL PHALLAIN JAMMU J K 180003 | JAMMU | JAMMU | J K | 180003 | L5 | Rejected-Finance Other than lowest bid |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
23 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ MAINT AND ATTENDING COMPLAINTS (ELECTRIC WORKS) DAY TO DAY FOR CERTAIN BLDGS IN NEW SOLANKI LINE, OLD SOLANKI LINE, SJ VIHAR, RAINA PARK, NEW ASSEY LINE, DBN VIHAR, THIMMAYA PARK, MAP JINDAN ROAD, PURAN ROAD OFFRS QTRS, NEW AND OLD PLASSEY LI
2021_MES_477644_1
GE/JULL/ET-41/2021-22
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹68,000
Yes
23 Nov 2021
25 Sept 2021
30 Oct 2021
25 Sept 2021
23 Oct 2021
11 Oct 2021
60 days
Amount
Attending complaints of no supply in light or power circuit due to burning/ disconnecting of any wire i.e. neutral phase or tripping of MCB or un-serviceability of any item such as switch socket MCB etc, rectification of fault including any petty repair required to restore the electric supply for checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of fuse, small pieces of wires etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws or switches, sockets, switch board, ceiling fans/ exhaust fans etc., required to make the item functional during 0900 Hrs to 1800 Hrs by deploying electrician alongwith helper including necessary tools complete all as specified and directed. Notes:- (a) Replacement of electrical fittings/ fixtures shall be measured and paid for separately under respective item of BOQ. (b) Repairs/ faults in any one quarter/ one occupancy shall be considered as one complaint (one measuring unit) even if repair is involved in more than one light point or fitting. However, all fitting/ fixtures replaced shall be measured & paid.
(c) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (d) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (e) Contractor shall ensure that the deployed electrician & helper will carry functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge. (f) Contractor shall be responsible for collection of all ON LINE complaints and handing over the same to JE E/M after rectification duly signed by user with details of stores fixed and to put the status ON LINE after attending/ complete of the job.
Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing in repairs bell push switch flush type 5 Amps, SP, 240 volts including taking down existing bell complete all as specified
Supply and fixing in repair socket out let 3 pin, 6 pin 15 Amp, flush type including taking down existing socket complete all as specified.
Supply and fixing in repairs socket out let 5 Amp, 5 pin flush type including taking down existing socket complete all as specified.
Supply and fixing in repairs socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, flush type including taking down existing socket complete all as specified
Supply and fixing in repairs switch piano flush type, 5 Amps, 240 Volt AC single pole, two way including taking down existing switch complete all as specified.
Supply and fixing in repairs bell electric AC (Ding Dong) 240 volt SP including taking down existing bell complete all as specified
Supply and fixing in repairs lamp holder insulated body with back plate suitable for batten fittings including taking down existing lamp holder complete all as specified.
Supply and fixing in repairs fan step regulator, electronic type, single phase, 300 watt including connection complete after dismantling/ removing unserviceable regulator all as specified.
Supply and fixing in replacement ceiling rose surface type bakelite 65 x 50mm three terminal including taking down complete all as specified and directed.
Supply and fixing in replacement copper wire PVC insulated 1.5 Sqmm single core stranded complete including taking down existing wire all as specified.
Supply and fixing in replacement copper wire PVC insulated 2.5 Sqmm single core stranded complete including taking down existing wire all as specified.
Supply and fixing in replacement copper wire PVC insulated 4 Sqmm single core stranded complete including taking down existing wire all as specified.
Supply and fixing in repair energy saving bulk head light luminaire with opal diffuser LED 10 watt 6000 K, power factor more than 0.90, IP-65 class-I protection with high efficiency BIS marked LED electronic driver, surge protection 2 KV, operative on 140 volts to 270 volts AC supply complete prewired, connecting and testing complete all as specified and directed. Notes:- (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii) Contractor shall produce LM-79 and LM-80 Report of NABL accredited Laboratory from manufacturer. (iii) Products must be made in India only.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 6 Sqmm PVC insulated with green insulation including taking down existing sub main wiring of any type complete all as specified.
Material and labour for sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation including taking down existing sub main wiring of any type complete all as specified.
Supply and fixing in repairs sheet metal enclosure for DBs when MCBs to be used, SPN 8 ways 240 V, with 200 Amps rated bus bar, double door all as specified
Supply and fixing in replacement DB's 4 way TPN double door suitable for MCB FP 'A' frame of rating 100 Amps and having breaking capacity 16 KA and MCB SP 6-32 Amps 10 KA (as per site requirement) in outgoing circuits complete pre-fitted, with neutral bar and earth bar complete all as specified. Note : Rates of MCCB and MCB are deemed to included in quoted rates
Supply and fixing in repairs MCB four pole, 415 volts of rating 63/100 Amps having breaking capacity 10 KA suitable for DB vertical complete all as specified.
Supply and fixing in replacement MCB SP 5 to 32 Amps, 240V, 10 KA including taking down existing MCB complete all as specified.
Supply and fixing in replacement MCB SPN 6 to 32 Amps, 240V, 10 KA including taking down existing MCB complete all as specified.
Attending complaints for non functional tube light/ wall security light 4 x 24 W/ 28 W/ 36 W/ 40 W fitting due to any reason such as loose connection or un-serviceability of any part such as ballast, side holders complete all as specified and directed. Note: Supply only of items such as ballast, side holders 28/36/40 watt shall be measured and paid under respective items.
Supply and fixing in replacement Deco Ultra Slim linear LED lighting fixture with co-extruded polycarbonate body environmental friendly energy efficient ready to use pack 18/ 20W LED 6000K complete all as specified and directed
Supply and fixing in repairs LED tube 4 feet 20 watt retro fit type wide distribution angle, self ballasted with built in driver including making connection, 2100 lumens 6000 K, power factor more than 0.90, IP-20 class-I protection, surge protection 2 KV, operative on 140 volts to 270 volts AC supply, having thermally conductive material for heat dissipation, products must be made in India only, complete all as specified and directed.
Supply and fixing in repair energy saving tube light LED luminaire with diffuser LED with & including CRCA MS box batten and 2 feet 9 to 12 watt (max) retro fit tube rod having terminally conductive material Lumen output 1000 lumens (min) 6200 K, power factor more than 0.90, IP-20 class-I protection, with built LED driver, surge protection upto 2 KV, operative on 140 volts to 270 volts AC supply, products must be made in India only, Complete prewired, connecting and testing complete all as specified and directed.
Supply and fixing in repair energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 35 watt LED for bldg security lights with high efficiency electronic driver, having IP-65 protection, surge protection min 2 KV power factor more than 0.95 complete operative on AC supply 140 volts to 270 volts pre-wired and product should be made in India only complete all as specified. Notes for Srl item No. 24 to 27: (i) Contractor shall provide 2 years written warranty for the LED fixture complete including driver from the certified date of completion from the local office bearer of manufacturers. (ii) Contractor shall produce LM-79 & LM-80 Report of NABL accredited Laboratory duly signed by the office bearer of manufacturer.
Supply and fixing in repair city 1 new decorative wall light fixture made up of polycarbonate, suitable for lamp type 1 x 9 watt retrofit LED lamp including 9 watt LED lamp of same make as fitting complete all as specified.
Attending complaints of not working/ abnormal noise of fans/ exhaust fan due to loose connection of any wire i.e. neutral/ phase not working of circuits or un-serviceability of any item such as capacitor, rubber real, wire etc rectification of fault including any sort of petty repair required to make the fans functional during 0900 Hrs to 1800 Hrs by deploying electrician with helpers including necessary tools complete all as specified.
Supply and fixing in repairs condenser 2.50 MFD including taking down existing complete all as specified.
Supply and fixing in repairs condenser 3.15 MFD including taking down existing complete all as specified.
Supply and fixing in repairs rubber reel for ceiling fan including nut & bolt including taking down existing rubber real complete all as specified.
Supply and fixing in repairs flexible cord of size 23/ 0.0076 sqmm including taking down existing cable complete all as specified.
Supply and fixing in replacement plastic laminated bakelite sheet top cover 3mm thick make hylum of size 9 x 11 inches or equivalent fixed with nickel polished screws with washers including making hole as per site requirement including taking out complete all as specified and directed
All as per srl item No. 34.00 here-in-before but 5 x 11 inches
All as per srl item No. 34.00 here-in-before but 8 x 5 inches
Supply and fixing in replacement MCCB FP 63 Amp, 415V with adjustable thermal magnetic release upto 16 KA breaking capacity including taking out complete all as specified and directed
Supply and fixing in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amp 240 V 10 KA including top plug complete all as specified and as directed.
Supply and fixing in replacement white modular switch 1 way 6 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed.
Supply and fixing in replacement white modular switch 1 way 16 Amp, 250 volt 1 module including taking down existing switch complete all as specified and directed.
Supply and fixing in replacement fan step regulator, 120W, 2 module including taking down complete all as specified and directed.
Supply and fixing in replacement modular socket, 6A, 2/3 pin combined 2 module including taking down complete all as specified and directed.
Supply and fixing in replacement modular socket, 6A/16A, 2/3 pin combined 2 module including taking down complete all as specified and directed.
AGGARWAL ENGINEERING CO
UNITED ENGINEERING CORPORATION
CHOUDHARY AND SONS
KULDEEP SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .