Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.5 Cr+₹3.5 L (2.37%)Rejected-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹1.5 Cr+₹3.5 L (2.37%) | L2 | Rejected-AOC Other than Lowest Bidder |
| 3 | L3₹1.6 Cr+₹16.6 L (11.2%)Rejected-AOC | ₹1.6 Cr+₹16.6 L (11.2%) | L3 | Rejected-AOC Other than Lowest Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in Category b(ii) |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
10 Oct 2023, 6:00 pmClosed
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh Pin-160003
PROVISION OF INFRASTRUCTURE FOR SPECIAL POWER SUPPLY WITH ASSOCIATED WORKS NEAR RAMP OF CERTAIN BUILDINGS AT AF STN CHANDIGAH
2023_MES_611868_2
CWE/AF CHD/CHD/T-11/2023-24
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Chandigarh
₹2.2 L
19 Dec 2023
14 Sept 2023
17 Oct 2023
14 Sept 2023
10 Oct 2023
25 Sept 2023
Amount
Building Work New constr/Addn/Altn
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified & directed.
Excavation in trenches n.exc 1.5m wide & n.exc 1.50m in depth for foundation , etc or for shafts, wells, cess pits, man holes,pierholes or for laying cables etc n. exc 10 sqm on plan & getting out in soft/loose soil. complete all as specified & directed.
M&L PCC 1:5:10 Type E2 (40 mm graded stone aggragate) as in fdn, filling and mass concrete. complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified & directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed.
M&L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM (1:6). complete all as specified & directed.
M&L Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified & directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire 0.9 mm dia. complete all as specified & directed.
Ditto all as per item No 1.08 here-in-before but 6 to 8mm dia. complete all as specified & directed.
Ditto all as item No 1.08 here-in-before but 5mm dia and over up to and including 10 mm dia in stirrups, spaces and binders etc complete all as specified & directed.
M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished flat surface of concrete. complete all as specified & directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvves including sup-ports, overhangs, etc. also splays between floors and beams, etc rough finished flat surface of concrete. complete all as specified & directed.
M&L form work to chullah hoods, chajjas, troughs and similar items including edges rough finished flat surface of concrete complete all as specified & directed.
M&L Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter rough finished flat surface of concrete complete all as specified & directed.
M&L Form work to sides of pillars, posts, struts, piers, columns and stanchions for rectangular or square rough finished flat surface of concrete complete all as specified & directed.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide rough finished flat surface of concrete. complete all as specified & directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified & directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
Ditto all as per item No 1.18 here-in-before but as in Chajjas etc complete all as specified & directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified & directed.
M&L for hard core of gauge n. exc 63mm broken stone or boulders deposited spread & leveled in layer not exc 15cm thick, watered and rammed. to a true surfaces complete all as specified & directed.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified & directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished surface even and fair ( w/o using extra cement)complete all as specified & directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished surface even and smooth ( w/o using extra cement) complete all as specified & directed.
Supply only Liquid water proofing compound complete all as specified & directed.
M&L for rendering 5 mm thick on fair faces of brick work on concrete surfacs in CM (1:3) on ceiling surface finished even and smooth ( w/o using extra cement) complete all as specified & directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified & directed.
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint over new surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (to be approved by the GE) (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified & directed.
M&L for preparation of new plastered surfaces and apply two coats of water based distmper over 1mm thick wall care putty to smoothening the surface by using sand paper complete all as specified & directed.
M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in Plinth Protection 75 mm thick finishing the surface even and smooth wihout using extra cement complete all as specified & directed.
M&L 40mm thick PCC (1:2:4) type B-0 as in DPC to horizontal or vertical surfaces including necessary formwork complete all as specified & directed.
M&L for cleaning of plastered or concrete surfaces of any description and applying water proofing treatment to roof surfaces consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) A layer of minimum 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.
M&L for 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring/padding finished even and fair complete all as specified and directed.
M& L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & directed.
M & L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured)complete all as specified & directed.
M & L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & directed.
M & L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & directed.
M&L Treating the soil along with external perimeter of building at the rate of 2.25 Ltr of emulsion per metre of the perimeter wall complete all as specified & directed.
S & F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified & directed.
M & L for powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all as per architectural drawings complete all as specified & directed.
S & F for Prelaminated particle board 12mm thick , interior grade, prelaminated both sides with decorative choice lamination , fixed with screws to aluminium/ timber frame work complete all as specified & directed.
S & F Sheet glass 5.50mm thick ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified & directed.
S & F Door closer hydraulically regulated, designation No. 3, aluminium bady universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified & directed.
S & F 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified & directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified & directed.
Supply and fixing 150mm long, extruded aluminium alloy handles, fabricated type, anodized complete all as specified & directed.
Supply and fix, sliding door bolts 250mm long, of extruded sections aluminum alloy, anodized, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminum, dia of bolt 10-12mm complete all as specified & directed.
S&F Aluminium Mortice lock 4 levers, vertical type, size 100 mm complete all as specified & directed.
M & L for 15 mm thick Screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified & directed.
M & L for acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors complete all as specified & directed.
Demolition of cement concrete in ground floor & paving n.exc 15cm below orabove ground level complete all as specified as directed.
M&L PCC 1:4:8 Type D2 (40 mm graded stone aggragate) as in fdn, filling and mass concrete complete all as specified & directed.
M&L preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for complete removal of old existing treatment from external surfaces of walls by wire brushes and applying 1mm thick cement wall care putty to obtain smooth regular/even finish surfaces by using sand paper and applying two coats of Cement base paint complete all as specified & directed.
M&L for complete removal of old existing treatment from internal surfaces on walls by wire brushes and applying 1mm thick cement wall care putty to obtain smooth regular/even finish surfaces by using sand paper and applying two coats of water based distemper complete all as specified & directed.
M & L for acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, as in dados/skirting over and including 10mm thick backing coat in CM 1:4 complete all as specified & directed.
M & L for Cutting out concrete blocks, slabs, brickwork or stone masonry (in alternate course), forming tooth-ings for and bonding new work in CM 1:4 into old work, including new materials entering old wall ( Type B1,1:2:4 using 20mm garded stone aggregate complete all as specified & directed.
M & L for Cutting opening in cement concrete walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc with or without reinforcement complete all as specified & directed.
M&L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:4 complete all as specified & directed.
M&L for Making good under cills or over arches, lintels and bressummers. including all-pinning when necessary complete in cement mortar 1:4 complete all as specified & directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410- W gde E-250 quality A complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (approved by the Engineer-in-Charge) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
M&L for Prepration of new steel Surfaces of any description, over 10cm in width or girth and applying two coast of synthetic emamle paint over one coat of red oxide primer complete all as specified & directed.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified & directed.
M&Lfor PCC in surface channels and drains type C2 (1:3:6 using 40 mm graded stone aggregate complete all as specified & directed.
M&Lfor MS framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; cable duct cover, framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290,Gde-E-165 complete all as specified & directed.
M&Lfor MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment for cable duct cover and similar work Fe.290.Gde-E-165 complete all as specified & directed.
Removal of surplus excavation soil to a distance exc 250 mtr but n.exc 500mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
INTERNAL ELECRIFICATION WORK
M & L for point wiring complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated sheathed FRLSH colour code 1100 volts grade drawn through in and including non metalic rigid PVC concealed conduits with all standard fittings such as Tee junction, bends, including new sunken terminal boxes duly epoxy painted for mounting switches/sockets etc complete with 3 mm thick PVC laminated sheet and incl 1.5 Sqmm multi stranded copper conductor PVC insulated shearthed FRLSH colour code cable 1100 volts grade for earth continuity for One light/fan point controlled by one way switch complete all as specified and directed
Ditto all as per item No 2.01 here-in-before but for One three pin 5 amp socket outlet multipurpose on independent board complete all as specified and directed
Ditto all as per item No 2.01 here-in-before but for One three pin 5 Amp switch socket cum on same board complete all as specified and directed
Dittp all as per item No 2.01 here-in-before but with 2.5 sqmm cable insulated for 3 pin 16 amp multipurpose outlet including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board complete all as specified and directed
S&F Switch piano, flush type single pole, one way 5 Amp complete.complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed.
S&F Socket outlet 3 pin, 5A, flush type complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and direceted.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and direceted.
S & F wiring for circuit/Sub main wiring along with earth wire with two single core 2 x 4 Sqmm (nominal area) PVC insulated and sheathed cables with stranded copper FRLSH conductor in and including PVC rigid concealed conduit of size 20 mm or higher ISI marked including one run of continuous PVC insulated FRLSH multi stranded copper cable of size 1 x 4.0 Sqmm earth wire for earth continuity conductor complete all as specified and direceted. Note : 02 runs of power cable of size 4sq mm, 01 run of 4sq mm earth continuity wire and 01 run of PVC conduite shall be considered as 01 RM for payment purpose.
S&F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and direceted.
S&F exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers complete all as specified and directed
S & F ceiling fans complete with blades, down rods and connected accessories 230 volts 1200 mm sweep min air delivery 210 CFM with BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and connecting up with twin twisted flexible copper conductor cable with suitable size incl 25 mm dia GI pipe medium grade and fixing clamps of suitable length/size complete all as specified and as directed.
Supply and fixing DB sheet metal enclosure double door for MCBs, company made, SPN 240 Volts 8 ways with IP 42 protection complete as specified and directed.
Supply and fixing MCB SP 240 Volts 6 Amps to 32 Amps 'B' curve complete all as specified and as directed.
Supply and fixing, MCB SPN 240 Volts 40 to 63 amps complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level earth plate surrounded by 15 cm thick and packed alternate layers of charcoal dust and common salt, earth lead wire 4.0 mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES Sch Part-1 (2009), complete all as specified and as directed.
EXTERNAL ELECRIFICATION WORK
Material and labour for XLPE insulated, armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, cross sectional area 95 sqmm 3.5core complete all as specified and as directed.
Material and labour for XLPE Insulated , armoured heavy duty electric power cables 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and as directed.
Suppy, installing, connecting, commissioning and testing of energy effficient transformer (level 2 of IS 1180) , of capacity 315 KVA outdoor type, step down 11/0.433 KV, core type oil immersed, copper wound, natural oil cooled with external cooling tubes/radiators, having 3 phase 50 Hz AC supply, DYn-11 design, off load tap changer on HT side to vary secondary voltage ±7.5% in steps of 2.5% as per IS 1180 (Pt-I to III) with all standerd accessories including HT and LT bushing, cable box on LT side, including first filling of new transformer oil (of di-electric strength not less than 50 KV) upto required level in conservator tank complete all as specified and as directed by Engr-in-Charge with and including the following :-
(a) One No 100 mm dia, dial type thermometer with resetting device vapour pressure type having range 0 to 120 degree centigrade. (b) Rating plate and terminal marking plate. (c) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing. (d) Oil level gauge with max & min level marking. (e) Oil filter valve. (f) Oil drain valve. (g) Lifting hooks. (h) Oil conservator with filling hole and cap. (j) Air relief valve plug. (k) Four solid cast steel detachable rollers (l) Earth bushing for neutral outside the LT cable box for providing independent earthing for neutral. (m) Clear view type silica gel breather with first fill of fresh bluish color silica gel.
M & L gang operated air break switches with vertical isolation complete with drop out fuse unit triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 200 Amps, 11000 volts complete with GI operating pipe of heavy duty grade 25mm dia of suitable length complete all as specified and as directed .
M & L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised iron strip of size 32x6 mm dia by means of bolts, nut check nuts and washers of GI or steel, earth wire protected by galvanized iron pipe 40 mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/Sqm complete all as specified and directed.
M & L for Lightning arresters for 11000 volts expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supplying and laying, factory made unreinforced precast cement concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
M&L locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protection prependicular to the direction of cable adjacent to each other complete all as specified and directed.
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L GI pipe light grade 100 mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc as per site requirement complete all as specified and directed.
M & L PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate for transformer foundation including form work etc complete all as specified and directed.
Supply and laying 80 mm outer dia, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Ditto All as per item No 3.15 here-in-before but of size 50 mm dia complete all as specified and directed. Note for item No 3.15 and 3.16 :- Pipes shall be fixed with drain wall with MS clamps made from 35x3 mm flat iron dully painted with two coats of enamelled paint over a coat of primer and 10 mm dia 150 mm long anchor fasteners ( two nos for each clamp), clamps shall be fixed at every 02 mtr distance. Unit rate quoted shall be deemed to include the cost of the same.
S & F HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories sutable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
Supply, installation, testing and commissioning of LT cubical panel (CPRI Approved) of suitable size factory made, compartment type, dust and vermin proof (IP-65) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm thick MS Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs made from 50mm X 50mm X 6mm angle iron for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double doors openable type inclusive locking arrangement & dully powder coated with approved shade and with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable glands and heavy duty aluminium thimbles for incomming & out going cables complete all as specified and with & including the following:-
SPECIAL POWER SUPPLY WORKS
Supply, installation. testing and commissioning of Aviation Static Special Power unit 75 KVA capacity suitable for operating at 0 degree to 50 degree centigrade temperature and encloser protection IP-4X with input voltage - 415V AC ± 10%, 3PH, 50Hz ±3Hz and output as under :- (a). AC - 208 Volts phase to phase and 115 Volts phase to neutral and frequency 400Hz , 3 phase 4 wire Type: Static, Control Circuitry: solid state IGBT Based, Voltage Regulation: ±0.08%, frequency Stability: ±0.08%, THD <3% for linear loads, Response time: Less than 4 cycles, Input Power Factor: >0.92, Load Power Factor: Unity to 0.8 Lag with in specified maximum output power ratings, Touch Screen Digital Metering Display for Input Voltage, Current, Frequency and output Power, Voltage, Current, Frequency with Data logging Facility with USB Interface. (b). DC -16 KW /27 Volts /600Amps Control Circuitry: solid state IGBT Based, Voltage Regulation (Line/Load): ±0.8%, Ripple: 5% RMS at rated voltage. Touch Screen Digital Metering Display for Input Voltage, Current, Frequency and output Voltage, Current all as directed. (c) Backup - Battery Backup: 25-30 minutes with SMF Lead Acid Battery of 12V/120Ah-Qty. 80 Nos complete including making connections with suitable size copper strips with copper nuts bolts & washers etc including mains connection with copper strips/ copper cables of appropriate size complete all as specified and directed. Make : M/S APLAB/ M/S GEORATOR / M/S K&B/ M/S GROW CONTROLS/ M/S P2 POWER.
Supply , install, testing and commissioning of Main Distribution Panel dully powder coated indoor wall mounting type fabricated out of 2mm thick CRCA sheet and 40x40x5 mm size angle iron for frame work, front door openable type with and incl locking arrangement suitable for 3 phase 415 volts with R-Y.B Phase Indication, copper bus bars epoxy insulated with color coding and mounted on epoxy insulators and 200A , 4 Pole , 50KA MCCB with adjustable thermal and magnetic release conforming to IS/IEC 60947-2 & IEC 60947-2 -01 No and including internal wiring with suitable size copper cable & circuit protection MCBs all as specified and directed. complete all as specified and as directed.
Supply , install, testing and commissioning of secondary distribution panel board dully powder coated indoor wall/floor mounting type fabricated out of 2mm thick CRCA sheet and 40x40x5 mm size angle iron for frame work, front door openable type with and incl locking arrangement suitable for 3 phase 415 volts with R-Y.B Phase Indication, copper bus bars epoxy insulated with color coding and mounted on epoxy insulatorswith with 200Amp , 4 Pole , 50 KA MCCB with adjustable thermal and magnetic release conforming to IS/IEC 60947-2 & IEC 60947-2 - 01 No and 600A DC , 2 Pole Circuit breaker, 200A/5P & 600A/2P Industrial Plug & Socket: 1No each complete all as specified and as directed.
Supply, laying, connecting and testing of 1100 volts grade 4 Core 120 Sqmm size copper cable and two run of single core 300 Sqmm size core flexible copper cable EPR Insulated cable annealed tinned copper conductor and cases laid up inner PCP shielded nylon housed reienforced outer HOFE PCP shielded with 6 pin NATO connector on each end and wheel mounted manually rolling cable drum complete all as direted. Note : 01 run of the cable of size 4 core 120 sqmm and 2 runs of 300 sqmm single core cable shall be considered as 01 RM for payment purpose.
M&L for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 3.5 mtr deep below ground level) with top edge of the plate not less than 2.75 mtr below normal ground level connected to copper strip earthing lead of size 25 x 3.15 mm thick by means of bolts, nut check nuts and washers of copper or brass, earth strip protected by galvanized iron pipe 32 mm bore (medium grade) connected to test point all as shown in electrical plate No. 3 of SSR - 2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/Sqm and MS frame taking out unserviceable earthing etc, complete all as specified and directed.
Leo Air and Power Solution pvt Ltd.
Choice india
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .