Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-AOC AOC to lowest bid of M/s Kumar Construction Co. | |
| 2 | L2₹30.6 L+₹98,550 (3.33%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹31.5 L+₹1.9 L (6.50%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹35.2 L+₹5.6 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest |
| Sl No | Description | Qty | Unit | sohtra and co L2 | KUMAR CONSTRUCTION CO L1 | s l sharma and sons L4 | RAMAN KUMAR L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Cleaning and desludging of existing septic tanks/Soakage wells of any capacity ( 10 users to 500 users ) including inlet and outlet chambers, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means , and removing waste material/sludge etc to a distance n.exc 50 mtr including digging , burrying in ground complete all as specified and as directed,
Note :-(i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor .
(ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth.
(iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers.
(iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt. | 400 | Cum | 160 ₹64,000 | 502 ₹2,00,800 | 100 ₹40,000 | 10 ₹4,000 Lowest |
| 2.00 | Dewatering of existing septic tanks of any capacioty (10 users to 500 user) including inlet and outlet chambers and soakage well,, taking out sewage water by mechanical pump and equipment, filling in closed tank atached with tractore or truck etc and removing the same out side from population area, complete all as specified and as directed,
Note :-(i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor.
(ii) Measurement of item shall be taken as effected measurement of septic tank which is occupied by the volume of water.
(iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers.
(iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt. | 500 | Cum | 50 ₹25,000 Lowest | 500 ₹2,50,000 | 100 ₹50,000 | 50 ₹25,000 Lowest |
| 3.00 | Excavation in trenches, n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation or for shafts,wells, cesspits, manholes,pier holes etc, n.exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in any type of soil, complete all as specified and as directed. | 100 | Cum | 397 ₹39,700 | 100 ₹10,000 Lowest | 300 ₹30,000 | 100 ₹10,000 Lowest |
| 4.00 | Excavation in trenches, n.exc 1.5 mtr wide and exc 1.5 mtr in depth but n. exc 3.00 mtr in depth, for foundation , laying of pipes and cable etc or for shafts,wells, cesspits, manholes,pier holes etc, n.exc 10 sqm on plan and getting out in any type of soil, complete all as specified and as directed. | 20 | Cum | 400 ₹8,000 | 100 ₹2,000 Lowest | 400 ₹8,000 | 100 ₹2,000 Lowest |
| 5.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm, in any type of soil, complete all as specified and as directed. | 80 | Cum | 20 ₹1,600 Lowest | 50 ₹4,000 | 25 ₹2,000 | 20 ₹1,600 Lowest |
| 6.00 | Removing excavated material (soil) to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50 m from the starting point, complete all as specified and as directed. | 40 | Cum | 20 ₹800 Lowest | 50 ₹2,000 | 25 ₹1,000 | 20 ₹800 Lowest |
| 7.00 | Dismantling of cast iron drain pipes, jointed in cement mortar and taking out of trenches (if required), of 75/100mm dia pipes, complete all as specified and as directed. | 200 | RM | 5 ₹1,000 Lowest | 20 ₹4,000 | 5 ₹1,000 Lowest | 5 ₹1,000 Lowest |
| 8.00 | Demolition and breaking up of drain pipe of 150 mm to 300 mm dia (Salt glazed ware, AC or reinforced concrete) set in cement mortar, complete all as specified and as directed. | 1,710 | RM | 5 ₹8,550 Lowest | 20 ₹34,200 | 5 ₹8,550 Lowest | 10 ₹17,100 |
| 9.00 | Concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed.
Note:- (i) Thickness of bed below barrel of pipe -10 cm.
(ii) Width of bed :- outer dia of pipe plus 30 cm. | 1,190 | RM | 59 ₹70,210 | 150 ₹1,78,500 | 25 ₹29,750 Lowest | 100 ₹1,19,000 |
| 10.00 | All as per item No 9.00 here in before, but 200 mm dia of pipe. | 500 | RM | 78 ₹39,000 | 200 ₹1,00,000 | 25 ₹12,500 Lowest | 120 ₹60,000 |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
30 Dec 2025, 6:00 pmClosed
GE (North) Udhampur
GE (North) Udhampur C/O 56 APO PIN-901220
SPECIAL REPAIRS TO SEWAGE LINE AND MISC WORK OF BLDG NO P-99 TO P-109, ADM AREA OF 5171 ASC BN AND ADJOINING AREA OF JNE MD ACCN UNDER GE (NORTH) UDHAMPUR
2025_MES_743597_1
GE/U(N)-87/2025-26
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (North) Udhampur
As per NIT
6 documents required · 6 mandatory
₹500
GE (North) Udhampur
₹94,600
Yes
29 Jan 2026
8 Dec 2025
6 Jan 2026
8 Dec 2025
30 Dec 2025
23 Dec 2025
Amount
Cleaning and desludging of existing septic tanks/Soakage wells of any capacity ( 10 users to 500 users ) including inlet and outlet chambers, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means , and removing waste material/sludge etc to a distance n.exc 50 mtr including digging , burrying in ground complete all as specified and as directed, Note :-(i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor . (ii) The solid or semi solid sludge shall be burried in pits and fully covered with a layer of lime powder and earth. (iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers. (iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt.
Dewatering of existing septic tanks of any capacioty (10 users to 500 user) including inlet and outlet chambers and soakage well,, taking out sewage water by mechanical pump and equipment, filling in closed tank atached with tractore or truck etc and removing the same out side from population area, complete all as specified and as directed, Note :-(i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor. (ii) Measurement of item shall be taken as effected measurement of septic tank which is occupied by the volume of water. (iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers. (iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt.
Excavation in trenches, n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation or for shafts,wells, cesspits, manholes,pier holes etc, n.exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in any type of soil, complete all as specified and as directed.
Excavation in trenches, n.exc 1.5 mtr wide and exc 1.5 mtr in depth but n. exc 3.00 mtr in depth, for foundation , laying of pipes and cable etc or for shafts,wells, cesspits, manholes,pier holes etc, n.exc 10 sqm on plan and getting out in any type of soil, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm, in any type of soil, complete all as specified and as directed.
Removing excavated material (soil) to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50 m from the starting point, complete all as specified and as directed.
Dismantling of cast iron drain pipes, jointed in cement mortar and taking out of trenches (if required), of 75/100mm dia pipes, complete all as specified and as directed.
Demolition and breaking up of drain pipe of 150 mm to 300 mm dia (Salt glazed ware, AC or reinforced concrete) set in cement mortar, complete all as specified and as directed.
Concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed. Note:- (i) Thickness of bed below barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
All as per item No 9.00 here in before, but 200 mm dia of pipe.
Reinforced concrete pipe Class NP2 laid and jointed complete with collars internal diameter 150 mm laid in trenches and complete all as specified and as directed .
Reinforced concrete pipe Class NP2 laid and jointed complete with collars internal diameter 200 mm laid in trenches and complete all as specified and as directed .
100 mm bore cast iron soil waste and vent pipes, sand cast, in any length with or without ears, with cement joints laid in trenches or in floors etc, complete all as specified and as directed.
50 mm bore cast iron soil waste and vent pipes, sand cast, in any length with or without ears, with cement joints,laid in trenches or in floors etc, complete all as specified and as directed.
100 mm bore cast iron soil waste and vent pipes, sand cast, in any length with or without ears, with cement joints but fixed in walls, complete all as specified and as directed.
75 mm bore cast iron, soil waste and vent pipes, sand cast, in any length with or without ears, with cement joints fixed on walls, complete all as specified and as directed.
S & F Cast iron bends (any radius),diminishing pieces or tapers (larger bore measured) for 100mm bore of pipe, fixed in repair, complete all as specified and as directed.
S & F Cast iron bends (any radius),diminishing pieces or tapers (larger bore measured) for 75 mm bore of pipe, fixed in repair, complete all as specified and as directed.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100 mm Bore pipe, including bolts and nuts and securing ends of stays to wall or roof
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays 75 mm dia Bore pipe including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
S & F Cast iron oval access door, fixed in repair for 100/75mm bore of pipe, complete all as specified.
Demolition of cement concrete ( reinforced ) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed.
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes/drain etc). and similar articles with plain faces/as requied for drain cover , set in cement mortar 1:6, complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in slabs supported on wall, beams etc or similar works, complete all as specified and directed by Engr-in-Charge. NOTE: Reinforcement shall be measured and paid separately under relevant item of Sch A.
Mild steel TMT bars 8mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed.
Cleaning of CI pipes 100/75mm bore by ridding and inserting jute bag to clean out the residue material and well flushing with water, making functional upto satisfication of Engineer in charge.
PCC 1:4:8, type D-2 (40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc, complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed.
Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius, using old size bricks, built in cement mortar 1:4 , complete all as specified and as directed.
All as per item No 29.00 here in before, but except bricks. Note-Old bricks obtained against dismantling shall be used.
Plain cement concrete 1:2:4 type B-1 ( using 20 mm graded crushed stone aggregate ) as in surface channel or drain etc, complete all as specified and as directed.
Extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
15mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4, mixed with water proofing compound, and finished even and smooth without using extra cement, complete all as specified and as directed.
Supply only integral water proofing compound conforming to IS-2645, complete all as specified and as directed.
Cutting into exising manholes for connecting new drains (internal dia of pipe n.exc 200 mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) smooth finished, and reforming benching complete all as specified and as directed.
Use and waste of formwork to sides and soffits of suspended slab such as roof slab,floor slab , landings and similar work not exceeding 200mm thick (horizontal or slopping) for rough finshed surface of concrete flat, complete all as specified and as directed.
M&L loose filling with broken bricks of gauge 80 to 150mm as in soakage pits including cleaning of existing sludge and other foreign materials complete all as sepceifed and directed.
S & F Vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests excluding flushing cistern but including connection to trap, anti syphonage pipe etc, fixed in repairs, complete all as specified and as directed.
S & F Viterous china wash down water closet pan 'P' or 'S' trap (Pedestal pattern) ,white with PVC seat cover, including fixing bolts, connection to drain pipe ( or out going pipe) and to flushing pipe, antisyphonage pipe etc , fixed in repair complete all as specified and directed.
S & F PVC (SWR) bends any radius, for 110mm bore of pipe, fixed with rubber ring joint, fixed in repair, complete all as specified.
S & F 110 mm bore PVC pipe single socketed in any length with rubber ring joints, fixed to wall, complete all as specified.
S & F PVC low level flushing cistern 10 ltrs capacity , valve less, syphonic action type, white, with inlet, ball valve, float and handle including brackets, PVC 32mm dia flushing pipe etc., fixed in repairs,complete all as specified and directed.
S&F in repairs plastic water closet seat, black or white colour, closet pattern with flat bottom and cover mild steel chromium plated or aluminum plated or aluminum hinging device complete all as specified and directed.
Demolition of cement concrete of any description and in position, not otherwise described complete all as specified and as directed.
Providing 50 mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in floor/path finished even and smooth without using extra cement, complete all as specified and as directed.
S & F Viterous china Urinals, half stall large coloured make CERA including connection PVC waste pipe of adequate dia and size CP grating with hole and urinal push valve including fittings fixed in repair complete all as specified.
S & F PVC (SWR) floor trap plain with grating including jointing with solvent cement, size 75 mm complete all as specified and as directed.
Supply and fixing PVC (SWR) gully trap of size 150 x 110 mm, setting and jointing with solvent cement complete all as specified & directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
M&L Non- skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and incl 15mm thick 1:4 screed bed complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in floors 75mm thick complete all as specified and directed.
M&L for Machine pressed coloured concrete interlocking paver block glossy finish, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment complete all as specified and directed.
M &L for 25mm thick Sand cushioning /filling under floors complete all as specified and directed.
M&L for factory made coloured glossy finish chequred cement concrete tile size 30cmx 30cm x 25mm thick machine pressed set & jointed in neat cement slurry as in floors joint filled up with white grey cement & pigments over and including 15mm thick screed bed with CM 1:4 complete all as specified and as directed.
Providing precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in kerb stone and similar work, bedded and jointed in CM 1:6 complete all as specified and as directed.
sohtra and co (BID ID -3511820)
RAMAN KUMAR (BID ID -3512002)
s l sharma and sons (BID ID -3513479)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tender87.pdf
Tender Documents • 1.05 MB
BOQ_832619.xls
BOQ • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .