Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
10 Oct 2019, 2:00 pmClosed
Er. Raman Sawhney
Office of the Deputy General Manager, JKPCC Ltd., Unit Kishtwar.
Internal Electrification work for New Polytechnic College at Kishtwar
2019_PWDJK_81150_1
e-NIT No. 38/Kishtwar of 2019-20 Dated 27-08-2019
Open Tender
Electrical Works
Item Rate
365 days
Kishtwar
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Financial Controller, JKPCC Ltd.
₹88,000
Yes
O/o The Managing Director, JKPCC Jammu
9 Jan 2020
4 Sept 2019
12 Oct 2019
4 Sept 2019
10 Oct 2019
10 Sept 2019
9 Sept 2019
Amount
Sub Head-I(Wiring)
Wiring for fan point/ exhaust Fan/call bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in Surface/ recessed medium class PVC Conduit , with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required. (Luminous/Anchor/Polycab)
Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(SB Controlled Primary light Points)(Luminous/Anchor/Polycab)
Providing Secondary light point wiring using 2 x 1.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(SB Controlled Secondary light Points)(Luminous/Paramount/Polycab)
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.(Luminous/Paramount/Polycab)
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required(Luminous/Paramount/Polycab)
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE
4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM EARTH WIRE
4 X 10.0 SQ.MM + 2 X 6.0 SQ.MM EARTH WIRE
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and Fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required
5/6 amps switch
3 Pin 5/6 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.(Luminous-Vivace/Schneider-Zencelo/Legrand -Arteor)
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 25 amps modular Multi pin socket outlet with connection,painting etc. as required.
Sub Head-III(DB's and MCB's)
Supplying and fixing following way,Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars,neutral bar/s with shroud/s, earth bar/s , sticking saddles , cement spill protector ,color-coded interconnecting wire set , cable ties , blanking plates and circuit identification labels.The D.B should be IK-10 Compliant.(The Cost of D.B is without MCB's)(IP Rating-43)(SCHNEIDER/LEGRAND/L&T)
4 Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(4+4+4) SP MCB's O/G's)
8 Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(8+8+8 )SP MCB's O/G's)
12 way (8 Module Incomer),(2+2+2 incomer DP RCCB),(12+12+12 SP MCB's O/G's)
Supplying,Installation ,Testing and Commissioning of Four Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required(SCHNEIDER/LEGRAND/L&T)
Supplying and Fixing Following rating,Double Pole (Single Phase and Neutral),240 Volts Residual Current Circuit Breaker (RCCB) having a sensitivity of current upto 300 ma in the existing MCB DB Complete with connections ,testing and commissioning as required.(SCHNEIDER/LEGRAND/L&T)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(SCHNEIDER/LEGRAND/L&T)
12 way, Double door
Supplying,Installation ,Testing and Commissioning of D.P Pole 220V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required(SCHNEIDER/LEGRAND/L&T)
Supplying,Installation ,Testing and Commissioning of 1P+N(2 Module) Surge Protection Device(SPD) Type 2,I max 15 KA (SCHNEIDER/LEGRAND/L&T)
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required(SCHNEIDER/LEGRAND/L&T)
Supplying and Laying of B-Class 100 mm Dia Size G.I Pipe under the Road/Floor not less than 1 mtr below the Ground Level including cutting the Road/Floor and making Good the same as required.
Sub Head-IV(Lightning Conductor and Earthing)
ENVIRONMENTALLY SAFE MAINTENANCE FREE EARTHING SYSTEM
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value.
Supplying,Installation and Testing of 75 mm Cu. Pipe Filled with Crystalline conductive Mixture with Copper Strip of Size 40 mm x 6 mm of Length 2 mtr with Ecofriendly Backfill Compound 50 Kg.(2 Nos for Panel and 2 Nos for UPS for Fire Alarm Syatem)Makes:- Genus/Ashlok/G-MAXX
Earth pit chamber (300mm x 300mm) with CI cover for the above.
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.
Sub Head -V(SITC of Fans and Fittings)
SITC of Ceiling Fan,Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.(Bajaj Kessels 50 ISI or Equivalent as Per Make List)
1400 MM SWEEP
SITC of LED 4' Batten Fittings 18/20 Watt (Bajaj, Philips & CG)
Supply of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required .(Bajaj Supreme Plus or Equivalent as Per Make List)
Sub Head-VI(Meter Board and Safety Items)
Supplying,Installation,Testing and Commissioning of Cubical Type LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars,Interlocking ,A.M.F Logic etc. as required as per the Following Description.(IP:42)(M/S Simon Fabricators,Jammu/CMKL,Dera Bassi/Power Associates &Co. ,Mohali)
INCOMER
MCCB 400 Amps 4 P with Breaking Capacity 25 KA(Icu=Ics=100%)(1 Nos)
MCCB 250 Amps 4 P with Breaking Capacity 25 KA(Icu=Ics=100%)(1 Nos)
MCCB 63 Amps 4 P with Breaking Capacity 25 KA(Icu=Ics=100%)(1 Nos)
Power Contactor 4 P 500 Amps(1 Nos)AC-3 With Electronic Coil Suitable for 24 V A.C/D.C Supply(2 Nos)
Power Contactor 4 P 320 Amps(1 Nos)AC-3 With Electronic Coil Suitable for 24 V A.C/D.C Supply(1 Nos)
Indicating Lamps RYB (3 Set)
Voltmeter-0-500 Volts(3 Nos)
Ammeter(0-400 A)(1 Nos)
Ammeter(0-250 A)(1 Nos)
SMPS 24 V D.C of Suitable VA Burden for Supply to Contactor Coil(1 Nos)
Current Transformer 400/5 A 10 VA Burden, Class-1(2 Sets)
Current Transformer 200/5 A 10 VA Burden, Class-1(sets)
Current Transformer 60/5 A 10 VA Burden, Class-1(1Sets)
Aluminium Busbar 500 Amps FP E-91 E Grade Electrolytic Aluminium
Digital Load Manager(2 Nos)
TPN MCB 6 A(9 Nos)
OUTGOINGS
MCB 63 Amps FP with Breaking Capacity 10 KA (17 Nos)
MCB 40 Amps FP with Breaking Capacity 10 KA (9 Nos)
MCCB 250 Amps FP with Breaking Capacity 25 KA With Icu=Ics=100%(1 Nos)
DP MCB 63 A 10 KA "D CURVE".(1 Nos)
Indicating Lamps ON OFF TRIP( 1 Nos)
Load Bearing Members to be made out of 2.0 mm CRCA Sheet.
Partitions to be made out of 1.6 mm CRCA Sheet
Gland Plates to be 3.0 mm Thick.
Uuder Ground Cables and Accessories
Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required .(Duraline/REX)
Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the existing RCC/Hume/DWC/Stone ware/Metal Pipe as Required.(KEI/Paramount/CCI)
3.5 C X 300 Sq.mm A2XFY
3.5 C X 185 Sq.mm A2XFY
3.5 C X 300 Sq.mm A2XFY
3.5 C X 185 Sq.mm A2XFY
M/S MAGOTRA ENGINEERS and CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .