Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC BHUBAN DANGA P O BOLPUR DIST BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹1.7 L+₹707.50 (0.42%)Rejected-AOC | L2 | Rejected-AOC Being L1 Bidder | |
| 3 | L3₹1.7 L+₹1,251.50 (0.74%)Rejected-Finance VILL P O GANRA DIST BIRBHUM PIN 731124 | GANRA | BIRBHUM | WEST BENGAL | 731124 | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹3,406
Closing Date
12 Dec 2024, 1:00 pmClosed
Executive Engineer, Birbhum Electrical DivisionPWD
Office of the EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri,Dist Birbhum, Pin 731101
Renovation of Electrical Installation work at Assistant Engineer quarter building in the premises of Bolpur Highway Sub Division under Birbhum Highway Division II, P.W.Roads Directorate
2024_WBPWD_778765_1
BIRED/131/e-NIQ(1st call) of 2024-2025
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Bolpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,406
Executive Engineer, Birbhum Electrical DivisionPWD
27 Mar 2025
4 Dec 2024
16 Dec 2024
4 Dec 2024
12 Dec 2024
6 Dec 2024
6 Dec 2024
Amount
SUB-HEAD 1--BDB,PDB,VTPN ETC---Supplying and fixing 240V 32 A DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall [1a/D-1] [Havells]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.---2+16Way [ Legrand ] [ 13 / D- 9 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ][Make-Legrand ]---40 A DP [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens /ABB/L&T) ---6-32 SP [ 7 / D- 6]
SUB-HEAD 2-- SUPPLY & LAYING OF WIRES---Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]--6 Mtr. [ 5(c)/E-25 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.--a) On board. [ 3 a / E-20 ]
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works.--19 mm dia 3 mm thick polythene pipe without earth continuity wire [ 3/ E- 2 ]
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works.---13 mm dia 3 mm thick polythene pipe without earth continuity wire [ 2/ E- 2 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.--3x(1.5 sqmm) [ 1(b) / E-9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
2x(6 sqmm)+1x(4 sqmm) [ 1(y) /E- 9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.---2x(2.5 sqmm)+1x(1.5 sqmm) [9 /F-5]
2x(4 sqmm)+1x (2.5 sqmm) [9 /F-5]
2x(6 sqmm)+1x(4 sqmm) [9 /F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS.--150 x 100 x 65 [11(b)/E-4]
Supplying & Fixing bakelite/perspex cover on existing inspection board by brass screws.---150 x 100 x 65 [12(b)/E-4]
SUB-HEAD 3-- PLUGS & SOCKETS----Supply & Fixing 240 V, 2 nos. 6 A & 1 nos. 16 A 3 pin Modular type plug socket with2 nos. 6 A & 1 nos. 16 A Modular type switch (Brand approved by EIC), 20A Modular type 1 way DP Switch and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [1b, 3a,3b & 4a,4b / E-17] [Computer board]
Supply & Fixing 240 V, 1 nos. 6 A & 1 nos. 16 A, 3 pin Modular type plug socket with 1 nos. 6 A & 1 nos. 16 A Modular type switch (Brand approved by EIC), without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [1b, 3a,3b & 4a,4b / E-17] [Seperate board]
Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand approved by EIC), without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed inbwall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [1b, 3a & 4a/ E-17] [Seperate board]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E-19 ] [AC starter]
SUB-HEAD 4 -FIXING OF FAN FITTINGS---Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E-18]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Fixing only exhaust fan after making holes in wall as per GS. (12") [ 28(b)/C-4 ]
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
SUB-HEAD 5 -SUPPLY OF FAN FITTINGS---Supply of ceiling fans(1200 mm Sweep) complete with all accessories having the following Model / Cat No. ( Make -Crompton High Speed(HS) /Orient Gratia/Usha of Similar Specification)
Supply of 230mm 1370 RPM Exhaust fans complete with all accessories having the following Cat No. P23009/4 ( Make -EPC ) [ NS ]
SUB-HEAD 6 -FIXING OF LIGHT FITTINGS---Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [14(d)/C-2]
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages towall and painting [19/C-3]
SUB-HEAD 7 -SUPPLY & FIXING OF LIGHT FITTINGS----Supply of 4 Ft. 20 Watt single/twin LED light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips) .---a. Single LED fittings (Philips cat No TMC 502 1XT-LED 22W ) with 1no. Master LED tube 1200mm 14W/2100lm 865(<10% THD) (PC body)
Supply & Fixing of 12W LED lamp to the lamp point. [PHILIPS make] [NS]
Supply and delivery of LED Street Light(230vac, 30 W, 120 Lumen/Watt, 6500K, IP 66, THD<10%, bult in 2.5KV SPD,CRI>80%, ) with all necessary connection.[Make: PHILIPS cat no.BRP330 LED30 CW R5N PC PSU S1 V1]
SUB-HEAD 8 -- EARTHING---Excavation of soil for installation of Earth Electrode and filling & ramming. (b) For Morrum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supply & Fixing circular bracket for 50mm dia earthing pipe made by 25mmx6mm galvanized MS flat by welding arrangemant with the pipe.Both sides of this MS flat will be extended to 100 mm 12mm dia drilled holes for connecting with 25mmx6mm MS flat.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
SUB-HEAD 9 -- MISCELENEOUS-----Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) asper GS.[20( a )/D-13]
Dismantling the existing damaged electrical installations by Co’s own Skilled labour tools and tackles and mending surface as far as practicable [NS]
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
NIRMAN ENTERPRISE (BID ID -5828274)
SHUBH LAABH ENTERPRISE (BID ID -5826044)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .