Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC Quoted amount is reasonable and found L1 bidder | |
| 2 | L2₹40.2 L+₹3.8 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Quoted amount is higher than L1 bidder | |
| 3 | L3₹41.2 L+₹4.8 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Quoted amount is higher than L1 bidder | |
| 4 | L4₹42.1 L+₹5.7 L (15.8%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L4 | Rejected-Finance Quoted amount is higher than L1 bidder | |
| 5 | L5₹43.0 L+₹6.6 L (18.1%)Rejected-Finance WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L5 | Rejected-Finance Quoted amount is higher than L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHAILENDRA SINGH RATHORE IDSE CE NFG
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
ADDN ALTN REPAIRS AND ALLIED WORKS TO CERTAIN BUILDINGS AT SAG PAKUR AT AF STN SINGARSI UNDER AGE I AF SINGARSI
2024_MES_655581_1
82437/SING/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE I AF SINGARSI
₹80,000
13 Sept 2024
23 May 2024
21 Jun 2024
23 May 2024
14 Jun 2024
7 Jun 2024
23 May 2024 - 28 May 2024
Amount
Demolition of cement concrete (unreinforced) in roofs, floors other than ground floors beams staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in roofs, floors other than ground floors beams staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer-in-Charge.
M & L for 25MM thick PCC type B-0 1:2:4 (12.5 mm Graded stone aggregate) as in roof padding , chajja repairs complete all as specified and as directed by Engineer-in-Charge.
M &L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortal (1:3) with water proof compound for surface finished even & smooth all as specified. Note:- WPC will be measured and paid separately.
M & L for APP based polymeric membrane minimum weighing 3.50kg/sqm and 3mm thick reinforced with polyster non woven fabric (weight not less than 160gsm/sqm) laid on surface applied with bituminous primer @0.25 ltr per sqm, by torch application with overlap 100mm on the traverse direction and 75mm on longitudinal direcion on existing RCC roof surface and applying one coat of aluminium paint over top surface of membrane @ 0.11 ltr/sqm complete all as specified and as directed by Engr-in-charge.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) n.exc. 1.5 sqm each, making good disturbed surfaces and removing materials from site of work complete all as directed by the Engr-in-charge.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm each but n exc 4 Sqm, making good disturbed surfaces and removing materials from site of work complete all as directed by the Engr-in-charge.
M & L for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge.
M & L for Powder coated (Minimum thickness of powder coating 50micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge etc complete all as specified and directed.
S&F 5.50mm thick sheet glass of ordinary quality and glazing with rubber in squares exc 0.50 sqm in each pane complete all as specified and as directed
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed
M & L Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and directed
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc
M &L for Rendering 20 mm thick on fair faces of brick work or concrete surfaces in cement mortal (1.4) with water proof compound for external brick surface finished even & smooth all as specified. Note:- WPC will be measured and paid separately.
Supply only Integral water proofing compound.
M &L for Rendering 15 mm thick other than fair faces of brick work or concrete surfaces in cement mortal (1.6) for internal brick with even & smooth surface all as specified.
M&L for complete removal of existing treatment of existing surface of wall (External) and applying two coat of acrylic exterior water proof emulsion paint complete all as specified and directed.
M&L for newly plastered surface of wall internal appying two coat of white or tinted oil bound distemper over one coat of alkali resistant priming paint over 3 mm thick coat of wall care putty etc complete all as specified and as directed
M&L preparation of old plastered surfaces of wall internal and applying two coats of distemper oil emulsion paint on wall all as specified.
Material and labour for applying one coats of white wash on old ceiling including preparation of old ceiling surfaces including all necessary scaffolding etc complete all as specified and directed
M&L for prepartion of new plaster surface of wall (External) and apply two coats of acrylic exterior water proof emulsion paint over a coat of primer complete all as specified and directed.
M & L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified.
M&L Non-skid colour ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqm as in floors set and jointed in cement slurry and pointed in white or colour cement to match existing surfaces complete all as specified
Material and labour for Virified Ceramic tiles (dark shade/double charge/ultracharge) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
Material and labour for Glazed ceramic tiles (400x400mm) x 7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
Material and labour glazed ceramic tiles of size 450mm x 300mm x 7mm thick coloured tiles on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface complete all as specified.
Material and labour for screed bed or bedding layers of 15 mm thick cement mortar (1:6) for laying floor finishes all as specified.
Material and labour for rendering 10mm thick cement mortar (1:4) receive tiles in vertical surface all as specified.
Suface excavation not exceeding 30cm in deep and averaging 15cm deep and getting out in soft/loose soil
Material and labour for chequered cement concrete tiles size 300 x 300 x 25mm thick with mixture of white and gray cement in equal proportion and no pigment set, jointed and pointed in neat cement slurry in floors complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil
M & L for old size brick work with fly ash bricks straight or curved on plan exc 6m mean radious built in CM 1:6 etc complete all as specified and as directed
M&L hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified & as directed.
M & L for use and waste of Formwork to rough finish surface to sides of pillars, posts, struts, piers, columns and stanchions etc all as specified and directed
M & L for use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, et in rough finish concrete surfaces etc all as specified and as directed
S&F factory made solid panel PVC door shuter 30mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails mild steel frame shall be covered with colour PVC laminated (both side), `C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement of stiles and plain colour PVC sheets for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the mild steel frame welded/Sealed to the stiles & rails with suitable PVC beading and joined together with solvent cement, complete all as specified and as directed. Note:- The surface of door will be wooden texture finish.
S&F solid PVC door frame size 50 mm x 47 mm made out of 5 mm plain colour laminated sheet both side PVC sheet, re-inforced with mild steel square tube, S&F in opening as per specified and as directed. Note:- The surface of door will be wooden texture finish. Note:- The surface of door will be wooden texture finish.
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed by Engr-in-charge
M&L for Plain cement concert 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete for manholes.
M & L for new size brick work with fly ash bricks straight or curved on plan exc 6m mean radious built in CM 1:6 etc complete all as specified and as directed
M&L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping including necessary use and waste of form work and finishing all exposed surfaces of concrete even and fair without using extra cement including weathering slightly rounded and chamfered angles and throating all as directed.
Material and labor for P.C.C type C-2, 1:3:6 (40mm graded aggregate) 75mm thick plinth protection.
S & F for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete all as specified..
Ditto all as per herein before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers and binders complete.
S&F structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete (Fe 410 W (Grade -250) quality 'B'
M&L for sand cushioning 50 mm thick laid in layers for paver blocks including spreading leveling, ramming etc complete all as specified.
M&L for machine perssed precast colored inter locking paver blocks wuith gray cement and pigment any shape and size conforming to IS 15658 - 2006 of 80 mm thick M-40 grade etc complete all as specified.
Dismantling wall and ceilling boards(fibre, pilp, insulation etc) or insulation boards/slab/blankets, any thickness including cover filletes etc complete all as specified and as directed
S & F power coated aluminium snap grid 605 x 605mm frame work for false ceiling with 12mm thick GI wire work all as specified
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
S & F 12mm thickNon asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out returing filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm in soft/loose soil.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregates in foundation filling and mass concrete as in lean concrete
M&L for RCC 1:2:4 type B1 using 20mm graded aggregates as in Columns, pillars, piers, posts and struts compelete all as specified and as directed.
M&L for RCC 1:2:4 type B1 using 20mm graded aggregates as in chajja complete all as specified and as directed.
M&L Roof trusses (framed), trussed, purlins, water staging, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including necessary welding, fabrication Fe-410W(GdeE-250) quality B
M&L Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.for post (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming Fe-410W(GdeE-250) quality B
S&F Plates of Fe 410W (Gde E-250) (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment to base of column, steel post and truss etc complete all as specified and as directed
S&F 12 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and apply two coats of synthetic enamel paints over a coat of red oxide zinc chrome primer
M & L for Cutting out decayed bricks from old walls and making good with new bricks in detached patches of not more than 7 bricks in CM 1:3 each patch complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.in hard/dense soil
Removing excavated material/old debries n exc. 50M and depositing where directed
M&L for 100 mm thick cement concrete type C-2 (1:3:6) using 40mm graded aggregate as in base floor all as specified
S&F Aluminium anodised tower bolt 150 mm long of extruded section etc complete all as specified and as directed
S&F 100 mm stainless steel butt hinges, medium weight, cold rolled, complete all as specified
S&F Aluminium handles, 150 mm size, cast type anodized complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
S/F in repair vitreous China squatting pan, `Orissa' pattern, size 580 x440 mm white, with integral foot rests n including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor (excluding flushing cistern and flush pipe)
S & F in repair Vitreous china squatting plate urinal,white (excluding flushing cistern, flush pipe and waste pipe)
S&F in repair of PVC valveless, syphonic action type, low level flushing cistern 10 Ltrs capacity with inlet, ball valve, float and handle including brackets (excluding flush/discharge pipe) complete all as specified and directed.
S&F in repair of Vitreous china WHB 550x400mm size white flat back with brackets incl cutting or pinning ends of brackets (excluding waste pipe) complete all as specified and directed. (Make: Hindware or Parry)
S&F in repairs of PVC connections 15mm size with PTMT nuts of length 450mm to flushing cistern and WHB complete all as specified and directed .
S&F of 15 mm bore pillar taps fancy type (long neck) cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letter hot or could with long screwed and shanks and fly nuts screwed for iron pipes
S&F in repair of 15 mm bore angle stop valves cast copper alloy screwed down high pressured with batterfly handle screwed both ends for iron pipes fancy type choromium plate (concealed type)
S&F in repairs for bib tap 15 mm bore fancy type chromioum plated with long shank & cup.
S&F of 600 x 450 mm bevelled edge mirror of seleceted quality glass mounted on 6mm thick AC building board or 5mm PVC sheet and fixed to wooden plug with CP brass screw and cup washer.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
S&F tubular towel rail 600mm long PTMT between flanges complete all as specified and as directed
S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to storeyard complete all as specified and as directed
Taking up or down steel tubing 20mm bore and connections, including cleaning for refixing or removal to storeyard complete all as specified and as directed
S/F for 15mm bore GI tubing medium grade with all fittings fixed to walls or laid in floors in concealed type complete all as specified and directed by Eng-In-Charge.
All as per item No- above but 20mm bore
S&F 75 mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring joints fixed to walls or floors
S&F 75 mm bore PVC (SWR) bends and Tee any radius complete all as specified and directed
S & F for Boarding hardwood 2nd class 15mm thickness, plane one side with butt joints supplied & fixed with nails in any situation (except flooring and skirting)
Dismantling boarding, any description, fixed in any position with nails all as sepcified.
Disconnecting existing tanks exc 500 ltr but n exc 1000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) all as specified and as directed
Disconnecting existing tanks exc 250 ltr but n exc 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) all as specified and as directed.
M & L for providing plain cement concrete 1:3:6 type C-1 (using 20mm stone aggt) as in kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and as directed by Engr-in-Charge.
Double action floor spring hydraulically regulated madeup of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
Note : Prior to commencement of the subject works, the contractor needs to submit valid Electrical License in the name of himself/them self or Agreement with agency having valid Electrical License alongwith Agency's Electrical License to the Accepting Officer for his approval through GE. In absence of such documents, no work will be executed at site and to be treated as defaulter on the Contractor's part . In addition, Supervisor for execution of electrical works employed by the Contractor shall posses Supervisory Certificate of competency issued by concerned State Govt/Union Territory and the Worker/Tradesman for execution of Electrical Works must hold necessary permit issued by concerned State Govt/Union Territory.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
M&L point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLS copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC casing capping slotted40/25/20 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and as directed.
All as per Item No 2 here-in-before but One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size all as specified and as directed.
All as per Item No 2 here-in-before One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size all as specified and as directed.
All as per Item No 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 2.5 Sqmm copper cable FRLS & 2.5 Sqmm FRLS copper cable for earth continuity wire complete all as specified and as directed.
S&F for switch socket combination 5 Pin, 6/15 Amp universal complete all as specified and as directed.
S&F for switch piano flush type 6 Amp single pole one way complete all as specified and as directed.
S&F for socket flush type 6 Amp single pole one way on same board complete all as specified and as directed.
S&F for switch socket flush type 6 Amp single pole one way on independent board complete all as specified and as directed.
M&L in repair Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. fixed on wall including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as above item above No 10but for One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq. mm size all as specified and as directed
All as above item above but for One 3 pin socket outlet, 5 amps, independen boardt, with cables , with cables 1.5 sq. mm size all as specified and as directed
All as per Item above here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 2.5 Sqmm copper cable FRLS & 2.5 Sqmm FRLS copper cable for earth continuity wire complete all as specified and as directed.
S&F modular metal flush box 2 module all complete all as specified
S&F modular metal flush box 6 module all complete all as spcified
S&F modular cover plate with 2 module frame all complete all as specifed
S&F modular cover plate with 6 module frame all complete all as specifed
S&F for modular switch socket combination 3 Pin, 16 Amp flush type complete all as specified and as directed.
S&F for modular fan regulator 120 watt all complete all as specified and as directed.
S&F for modular socket 6 A 2/3 pin combine 2 module all complete all as specified and as directed.
S&F for modular switch 6 Amp single pole one way complete all as specified and as directed. all complete all as specified and as directed.
S & F call bell, ding dong AC 230 volts, single pole complete all as specified and as directed.
S & F bell push, flush type, 5 amp complete all as specified and ad directed.
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.
S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 240 Volt,4 way with built in160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA complete all as specified and as directed.
M & L for MCB, SP, 240V,40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M & L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M & L for MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed.
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket complete all as directed
S&F in repair LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed .
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-charge.
S&F in repair LED light fitting 1 X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed by Engr-in-charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engr-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed.
S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louversnecessary electric connections using 1.0 sqmm twin twisted flexible wire complete all as specified and as directed by Engr-in-Charge. Make:- Orient or equivalent in Bajaj/havells/USHA Note: Making suitable dia of hole in wall and making good, removal of debris from the site should be included in quoted rates.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, necessary electric connections using 1.0 sqmm twin twisted flexible wire complete all as specified and as directed by Engr-in-Charge.
S&F Smart Fan Rod or Anti Suicide Fan Rod for ceiling fans 1200 /1400 mm sweep having following specifications /sizes in white color, Thickness of Rod = 1.84(+/-0.05) mm on zinc plated MS Pipe with zinc plated spring mechanism, MSME Tested for 15 Kg weight bearing capacity and breaking at impact load of 22Kg+, the fan down rod opens from its center and spring hidden in pipe, expands to land person on ground safely complete all as specified and as directed by Engr-in-Charge.
Dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, motor winding, ball bearing, gun metal bush etc. complete to carry out Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b)New spare parts (i.e) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, anti suicidal rod shall be measured and paid separately under relevant item.
M&L for Rewinding of Ceiling fan1200/1400 mm Sweep / exhaust fan 300 mm sweep
Supply and fixing rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200/1400 mm sweep.
Supply and fixing bearing number of 6201/6202/6203/6204 as required, Make : SKF/NBC or Eequivalent
Supply and fixing condenser 2/2.5 Mfd
Supply and fixing PVC holder for condenser housing.
Supply and fixing twin core twisted copper flexible wire/cable of size 0.5 sqmm, single core
Supply and fixing gun metal bush .
M&L for fan regulator electronic type, single/double module, 5 stepped type 240 Watt, hum free flush type on the existing laminated sheet complete all as directed .
Dismantling complete exhaust fan 300/350 mm sweep condenser housing with its rubber bushes, split pins, unscrewing the body parts of exhaust fan, taking out starter, motor winding, ball bearing, gun metal bush etc. complete to carry out Painting of exhas fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and carry out the following repairs :- (a) Removing of burnt out winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b)New spare parts shall be measured and paid separately under relevant item.
Supply and fixing condenser 3.15/4 MFD (metal body) Make:Universal/Sarda or Equivalent
Supply and fix exhaust fan motor AC single Phase. 230V for size 300 mm , 85 watts sweep exhaust all as specified and directed
Supply and fixing complete frame with side holding clamps with suitable nuts/bolts for exhaust fan 300 mm sweep as per existing make/size as specified and directed
Supply & fixing blade made of iron suitable for Exhaust fan 300 mm sweep
Taking down / dismantling of defective / rusted storage type hot water gyser of 50/25 ltr capacity from different locations by disconnecting inlet / outlet connections and taking out unserviceable parts by unscrewing bolts and nuts etc deiscaling / cleaning inner servicing and etc. Checking defects, re-assembling and re-installing the gyser in position, connection and testing complete.
Supply & fix indication lamp (green / red) as required.
Supply& fix thermostat of range 0-90 degree centigrade as required.
Supply& fix heating element 2 KW (ISI Marked) cup type / thread type with the provision of thermal cut out as required.
Supply& fix inner ss tank of cap 25 ltr all complete all as spefified
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for cold water.
S&F hot water pipe for gyser, connection with check nuts and washers.
S&F in replacement of gun metal non return valve of 15mm dia ISI marked.
S&F in replacement of stop cock brass of 15mm dia.
S&F Bib taps of size 15mm, cast copper alloy with crutch or butterfly handle, screwed down, crewed for iron pipe or for brass ferrule and fixed and fixed complete all as specified and as directed.
S&F in replacement of GI tubing medium grade 15mm dia with all fittings and fixed to wall, ceiling or roof complete all as specified and directed.
M&L Submain wiring with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories fixed to wall complete including taking down old wiring and making good the disturbed area for 3 runs 2.5 Sqmm (01 No phase conductor, 01 no netral conductor, 01 earth continuity wite complete. ( Note:- (i) 3 runs of 2.5 Sqmm and one run of casing caping shall be measured and paid as one length.
LALAN SHARMA
P .BANERJEE AND CO
M/S KUMAR AVINASH
M/S New Builders Corporation
M/S MBS TRADING CO
M/S SINGH ENTERPRISE
M/S ASHA ENTERPRISE
DANATION CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .