Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | L2₹23.7 L+₹3.4 L (16.8%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK PULGAON 442302 | WARDHA | MAHARASHTRA | 442302 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹25.0 L+₹4.7 L (23.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹25.9 L+₹5.7 L (27.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹26.9 L+₹6.6 L (32.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25.4 L
EMD Value
₹50,800
Closing Date
18 Dec 2021, 6:00 pmClosed
GE PLGAON
GE PULGAON PIN-442303
SPECIAL REPAIRS TO ROOF OF BLDG NO P-19(LIBY) NEAR ADM BLOCK AND SPECIAL REAPAIRS TO BLDG N/P 01(UR SEC MT) IN RA AT CAD PULGAON
2021_MES_489986_1
8934/PUL/E8
Open Tender
Civil Works
Works
180 days
GE PULGAON
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹50,800
Yes
17 Jan 2022
25 Nov 2021
24 Dec 2021
25 Nov 2021
18 Dec 2021
4 Dec 2021
2 Dec 2021 - 3 Dec 2021
Amount
Dismantling of Asbestos cement (corrugated, semi corrugated etc) sheets in roof covering complete all as specified and as directed
S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F rolled sections as in main and cross beam, hip and jack rafters; purlins where conected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Fe-410W(Gde E-250) quality complete all as specified.
Supply and fixing bands straps supports or stays for rainwater,ventilating pipes including bolts, if required: hooks (stay) heavy for large gates, hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans plain angle cleats for securing purlins to woods trusses or rafters; knee piece inserts, two way and three way straps, plats wahsers and similar small articles conforming to Fe-410WA Gde-E-250 complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directe incuding necessary formwork required complete all as specified and as directed.
M&L for preparing new or previously untreated surfaces, of steel and iron work of any description not otherwise described exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for preparing old painted surfaces, of steel and iron work of any description not otherwise described exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling ceiling boards/insulation boards as in ceiling of any description or size including cover fillets complete all as specified and as directed
M&L 8 mm thick designer ceiling board (Make : Everest or equivalent as approved by GE) in ceiling fixed with screw as per manufactures instructions, fixed with white powder coated galvanized iron grid with 24mm wide T-section exposed flanges comprising of main runner made from 0.33mm thick galvanized steel sheet & of size T 24x32mm and spaced at 1.2m c/c securely fixed to the structural soffits by hangers at 1.2m of GI wire 4mm dia fixed pipe or wall plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200mm long cross tee with (double stitching) to be inter locked between main runners at 600mm c/c to form 600x600mm modules, angle along perimeter wall shall be of 0.45mm thick galvanized steel of size 19x19mm of white colour all as per instruction complete all as specified and as directed.
M&L for Complete removal of existing treatment on old surfaces on walls and applying two coats of distempering on walls with distemper oil emulsion over a coat of chalk whitening as primer complete all as specified and as directed.
M & L for Complete removal of existing treatment on old surfaces on walls two cement base paint over a coat of white cement as a primer including preparation of old surfaces complete all as specified and as directed.
Taking down chowkats or frames with shutter w/o taking off shutter from the frame n exc 1.5 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15 cm thickness (below or above ground level) and removing salvage to a distance not exc 50 m complete all as specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material outside the premises complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in Unframed work complete all as specified and as directed.
M&L for Brick work with fly ash bricks straight or curved on plan exc 6m in radius but built in 1:6 cement mortar complete all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F 1 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required.
M&L Cement concrete type C-0 (1:3:6) using 12.50 mm graded stone aggregate as in filling in pressed steel chowkhat,fixing of hold fast etc complete all as specified and as directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe – 290 Gde E -- 165 complete all as specified and as directed.
S&F steel windows/vent with side hung shutters including projected type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded, with guard bars complete all as specified and as directed.
S & F of Stainless steel wire cloth, 0.36mm normal dia of wire and avg. width of aperture 1.40 mm and fixed with stinless steel wire staples complete all as specified and directed.
M & L for preparation of Old painted wooden surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of Old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Glazed ceramic coloured tiles of size 450 mm X 300 mm X 7 mm thick as on vertical surfaces such as skirting, dados and rises to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 10 mm thick CM 1:4 complete all as specified and as directed
M & L for providing 50 mm thick cement concrete 1:2:4 (using 20 mm thick graded stone aggregate) as in floor, laid in panels and position to conform to design and finishing top surface even and smooth with using extra cement complete all as specified and as directed.
Supply and fixing 3 mm thick and 38 mm wide Glass dividing strips as in floors inserted in position, conform to design complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles (square / rectangular) of 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exc. 0.18sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 15 mm thick screed bed (1:6) CM complete all as specified and as directed.
Dismantaling of stone slab and tiles of any description or thickness in floor laid bedded and pointed in any mortar etc. complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:6 complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of stone wall surfaces finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:4 on fair face of stone wall surfaces finished even and smooth without using extra cement all as specified. ( incl all necessary scaffolding, lifting arrangement for three story building on external surfaces).
M&L preparation of plastered surfaces of wall and applying two coats of oil bound distemper over two coat of ( 3 mm thick) wall care putty on new plastered surfaces of wall complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement primer complete all as specified and as directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and as directed.
100mm thick PCC (1:4:8) type D-2 (using 40mm gradded crushed stone aggregate) as in sub base complete all as specified and as directed.
Taking down carefully concealed/ casing caping/ PVC Conduit point wiring copper / aluminium (light / fan / scoket) complete (with fittings such as switches ceiling rose, pendents, regulators sockets etc) and making good disturbed surface with exisitng specification complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm single core sheathed PVC insulated FRLSH cable 1100 V grade multistranded copper conductor of different code of ISI marked drawn through and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including provision of PVC box of suitable size for mounting switches / sockets and fan regulators etc complete all as specified and directed for the following:- Note : Point wiring will be done with existing old MCB DB
One light point controlled by one switch one way
One ceiling fan / exhaust fan / wall mounting fan point controlled by one switch one way
One socket outlet three pin 5/6 Amps controlled by one switch on the same board.
One switch socket outlet three pin 5 /6 Amps controlled by one switch on independent board.
M&L for point wiring with stranded copper conductor 2.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and sheathed cabel 1100 volts grade, ISI marked drawn in and incl PVC casing caping of suitable size with accessories ISI marked incl PVC insulated copper cable for earth of same type and sized connected to earth dolly including provision of PVC box of suitable size for mounting complete all as specified and directed.
M&L for switch piano flush type single pole,one way, 5 Amps, 240 V complete all as specified and directed including taking down old U/S one. Make : Anchor/Havells/Cona
S&F socket outlet 5/6 pin type,5 Amps, 240 V complete all as specified and directed including taking down old U/S one . Make : Anchor/Havells/cona
Supply & fix switch socket combination flush type 2 and 3 pin, 5 Amps, 250 volts, AC, multipurpose all as specified and as directed.
S&F switch socket combination flush type (multipurpose type) but 15A/16A, 5 in 1 15 Amps, 240V complete all as specified and directed including taking down old U/S one.
S&F ceiling rose surface type with 3 terminals complete including taking down old U/S one .Make : Havells/Anchor/Cona
S&F fan regulator electronic step type AC 240 Volts,50 Hz complete including taking down old U/S one . Make : Anchor/Cona/Havells
Supply and fixed LED light fitting 1 x 20 watt,220V, AC decorative box type with driver, holder including LED tube light cnonecting up with three core flexible copper conductor cable of suitable size form ceiling rose complete, Make Havells /Philips/Bajaj .
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall, ceiling and making good surfaces to match with original status as specified and directed.
M&L for sub main wiring alongwith earth wire for 2 run of 4 sqmm PVC FRLS copper cable and 1run of 4 sqmm PVC FRLS copper cable for earth wire of FR PVC insulated copper conductor, single core cable in PVC Casing caping 20mm complete all as sfecified and directed Note for sub main wiring :- 2 runs of wire and 1 run of earth wire will be measured as one unit i.e RM Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire
Material and Labour for earthing complete in replacement of old with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth lead wire 4.00mm dia by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC 1:3:6 type C-1 40mm thick chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 15mm bore, medium grade 7.5m long as applicable and as per plate No. 3 of SSR Part-I 2009 and all as specified.
Taking down carefully ceiling fan along with clamp, nut, bolt, washer and refixing the same after oiling,painting,greasing. Also making arrangment by fixing GI Medium grade 40 mm dia pipe in wall for hanging ceiling fan. Note : GI Pipe measured and paid in separately in respective item.
Supply and Fix in repairs to wall / pole of any height LED bldg security light 35 watt including GI pipe sutaible dia bracket not less than 1 mtr bend to shape with 2 clamps, nuts, bolts, washers and PVC 3 core ISI mark flexible wire from ceiling rose to fitting complete all as specified and as directed. Make of Havells or eqvt in Philips / Wipro
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core
Supply and lay pipe galvanized, “Medium class”, including fittings 40 mm dia (Cable Protection Pipe) and necessary GI Clamps for fixing with pole and with all a nuts, bolts complete all as specified and as directed.
Material and labour for point wiring complete with 1.5 sqmm single core sheathed PVC insulated FRLS cable 1100 V grade multistranded copper conductor of code red, blue and yellow for phase, black for neutral and green for earth of ISI marked drawn through and including non metallic rigid PVC Conduit of suitable size with accessories ISI marked including PVC insulated copper cable for earth continuity conductor of same type and size and connected to earth dolly in existing of sunken cast iron/pressed steel terminal boxes complete all as specified and as directed.
One light point controlled by one switch one way
One ceiling fan oint controlled by one switch one way
M&L sub main wiring alongwith earth wire for 4 run of 6sqmm PVC FR copper cable and 2run of 6 sqmmPVC FRLS copper cable for earth wire of FRLS PVC insulated copper conductor, single core cable in PVC conduit of suitable size with accessories ISI marked concealed in wall/ceiling complete all as sfecified and directed. Note :- 4 runs of wire and 2 run of earth wire will be measured as one unit i.e RM 2. Groove Cutting ,pinning and plastering of disturbed surface etc shall deemed to be included in the quoted rate.wiring 2 run of wire and1 run of earth wire
Supply and fix in replacement of LED recessed mounted 2' X 2' 36 Watt light along with fixture including taking down old unserviceable FTL any type complete all as specified and as directed. Make: Crompton/Bajaj/Havells
S&F in replacement of sheet steel enclosure with Double door TPN 4 ways 440 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces complete including taking down old one all as specified and as directed. Make : Havells/legrand/Schneider
S&F in replacement of sheet steel enclosure with double door flush mounting ,MCB, DB, SPN, 8 ways,240 volt factory fitted rated bus bars,earth bar,neutral links complete incl. blanking plates as required & making good the disturbed surfaces complete including taking down old one all as specified and as directed. Make : Havells/legrand/Schneider
S&F in replacement of MCB TPN 63 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series complete including taking down old one all as specified and as directed. Make:Havells/Legrand/Schneider
S&F in replacement of MCB SPN 32 Amps 240V ,50 Hz ,breaking capacity 10 KA," C " series complete including taking down old one complete all as specified and as directed. Make:Havells/Legrand/Schneider
S&F in replacement of MCB SP 06-32 Amps 240V ,50 Hz, breaking capacity 10 KA," C " series complete including taking down old one complete all as specified and as directed. Make:Havells/Legrand/Schneider
Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core including taking down old one.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 metre depth for foundation, laying of cables/pipes/poles etc., and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supply and lay, dry river sand filling in trenches to required width at bottom and top of cable as cable cushioning including spreading, leveling, watering and consolidation complete all as specified and as directed.
Supply and laying brick sub class"B" having minimum compressive strenght 75 Kg/Sqcm laid in trecnches for cable protection etc complete all as directed by Engineer-in-Charge
M/s Dara Constructions, Pulgaon
m/s A.A brothers
RAJ ENTERPRISES
Rehal Construction
Bidder Name
m/s A.A brothers
Rehal Construction
RAJ ENTERPRISES
M/s Dara Constructions, Pulgaon
M/s MM TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .