| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹17.1 L+₹25,604 (1.52%)Rejected-AOC 9 THIRMURUGAN NAGAR KAILASANATHAR KOVIL THIRUNINRAVUR CHENNAI 602024 | THIRUVALLUR | TAMIL NADU | 602024 | L2 | Rejected-AOC L2 BIDDER |
| Sl No | Description | Qty | Unit | SRI ATHIRAN CONSTRUCTION L2 | Sadha Construction L1 |
|---|---|---|---|---|---|
| 1.00 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT | 21 | m2 | 7,207.11 ₹1,51,366.95 | 7,085 ₹1,48,802.36 Lowest |
| 2.00 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - | 28.26 | m3 | 7,999.72 ₹2,26,071.16 | 7,881.5 ₹2,22,730.2 Lowest |
| 3.00 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. | 2,119.49 | KG | 91.52 ₹1,93,981.19 | 90.17 ₹1,91,114.47 Lowest |
| 4.00 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 | 383.18 | m2 | 881.47 ₹3,37,760.81 | 868.44 ₹3,32,769.27 Lowest |
| 5.00 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.JeIly 20mm gauge in pure slaked lime (no sand to be added) over roof slab, the proportion of brick jelly to lime being ‘32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete - 1 m3 | 7.48 | M3 | 3,969.66 ₹29,693.09 | 3,911 ₹29,254.28 Lowest |
| 6.00 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete | 93.5 | M2 | 1,218.05 ₹1,13,887.75 | 1,200.05 ₹1,12,204.68 Lowest |
| 7.00 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work | 152.94 | M2 | 1,493.67 ₹2,28,444.14 | 1,471.6 ₹2,25,068.12 Lowest |
| 8.00 | Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications | 152.94 | m2 | 300.39 ₹45,941.86 | 295.95 ₹45,262.92 Lowest |
| 9.00 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications | 267.95 | m2 | 260.86 ₹69,895.58 | 257 ₹68,862.64 Lowest |
| 10.00 | Painting two coats with approved quality of (emulsion paint) cement paint over the plastered surface including curing cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification | 379.44 | m2 | 242.59 ₹92,045.97 | 239 ₹90,685.68 Lowest |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
6 Aug 2025, 3:00 pmClosed
THE COMMISSIONER
AVADI CITY MUNICIPAL CORPORATION AVADI
Construction of Additional Community hall 1st floor Building at Anandha Nagar in Ward No 46
2025_MAWS_586991_1
Roc No.7892/2025/E1/9
Open Tender
Civil Works
Fixed-rate
150 days
Ward No 46
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹20,000
15 Aug 2025
30 Jul 2025
6 Aug 2025
30 Jul 2025
6 Aug 2025
30 Jul 2025
Amount
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.JeIly 20mm gauge in pure slaked lime (no sand to be added) over roof slab, the proportion of brick jelly to lime being ‘32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete - 1 m3
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Painting two coats with approved quality of (emulsion paint) cement paint over the plastered surface including curing cost and conveyance of all materials to site and all labour charges etc., complete as per standard specification
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion withsuitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil)
Fan point
Tube point
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp
Supply and fixing of 4'40W twin box type fluorescent fitting complete with copper choke and condensor with TW round block on wall or ceiling with tubes and PVC unsheathed copper leads from terminal to the fitting with fluoresent tubes
Supply and fixing of 5A/15A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and concealed with 3mm thick hylem sheet
SRI ATHIRAN CONSTRUCTION (BID ID -1422249)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .