| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC TPC decided to accept the L-1 offer of M/s Gaurav Construction, Kanpur at Rs. 1,05,57,457.86 and to place work order for execution of the subject work as per the condition of the T.E. |
| 2 | L2₹1.1 Cr+₹4.5 L (4.27%)Rejected-Finance | ₹1.1 Cr+₹4.5 L (4.27%) | L2 | Rejected-Finance TPC decided to accept the L-1 offer of M/s Gaurav Construction, Kanpur at Rs. 1,05,57,457.86 and to place work order for execution of the subject work as per the condition of the T.E. |
| 3 | Rejected-Technical | - | - | Rejected-Technical CWC I decided not to open Price bid of Raghvendra Traders |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
16 Feb 2024, 5:00 pmClosed
Executive Director
Ordnance Factory Kalpi Road Kanpur-208009
Construction of Work for Proposed Class room for new Courses in Armapur Post-Graduate Degree College, Kalpi Road Armapur Estate Kanpur, U.P.
2024_AWEIL_184405_1
OFC/EOC/01/DC/2023-24
Open Tender
Construction Works
Item Rate
180 days
Armapur Degree College
As per TE Conditions attached as PDF files. Contractor shall submit their offer against TE with 18 percent GST and Labour Cess 1 percent on calculated overall amount comes after adding 18 percent GST.
2 documents required · 2 mandatory
₹0
₹1.9 L
Yes
8 Mar 2024
3 Feb 2024
19 Feb 2024
3 Feb 2024
16 Feb 2024
3 Feb 2024
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Making Layout of building works including making of pucca pillers (Burji) and marking centre line including cost of lime and all T&P (Only plinth area of ground floor to be measured and paid)
Earth Work in excavation by mechnical means (Hydraulic Excavator)/Manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ),excavated soil and disposal of surplus excavated soil directed ,with in a lead of 50 m,including dressing of sides and ramming of bottoms lift up to 1.5 m,including getting out the all kinds of soil .
Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T&P etc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
Supply and Fiiling in Plinth With Sand Under Floors,Including Watering,Ramming, Cosolidating and dressing Complete.
Providing and laying in position ready mixed M-25 grade Concrete for reinforced cement Concrete Work,Using cement Content as per approved design mix,manufactured in fully automatic batching plant and transporated to site of work in transit mixer for all leads ,having continous agitated mixer ,manufactured as per design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit Mixer to site of laying ,excluding the Cost of Centering,Shuttering finishing and reinforcement including cost of admixtures in recommened proporatoons as per IS :9103 to accelerate /retard setting of concrete ,improve workability without inpairing strength and durability as per direction of the Engineer in Charge (in Foundation, Column up to plinth, Tie Beam/Plinth Beam)
First Class brick work in 1:6 cement and coarse sand of 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand)
Providing and Injecting Chemical Emulsion For pre-constructional antitermite treatment and creating and chamical bariier under and around the column pits wall trenches basement excavation top surface if Plinth filling junction of wall and floor along the external perimeter of binding expansion joints surrounding of pipes and conduit etc complete (Plinth area of the building at ground floor only shall be measured as per I.S 6313 ( Part II 1981 ) approved material such as hepthachlor or chlordane will be used .
Steel Reinforcement for R.C.C Work including Straighting ,Cutting,Bending Placing in position and Binding all Complete upto Plinth Level -Termo Mechnically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns for Mass Concrete
Centering and shuttering including strutting, propping etc. and removal of form work for Columns,Pillar,Piers,abutments,Post and Struts
Centering and shuttering including strutting, propping etc. and removal of form work for Tie Beam /Plinth Beam
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
Supply of 32 mm wide and 2.8- 3.7 mm thick Glass Strips in apron
Making drain along with the appron of Size (250X150 mm) including Earth Work ,P.C.C ,Brick Work ,Plaster etc Complete.
Providing and laying in position ready mixed M-25 grade Concrete for reinforced cement Concrete Work,Using cement Content as per approved design mix,manufactured in fully automatic batching plant and transporated to site of work in transit mixer for all leads ,having continous agitated mixer, manufactured as per design of specified grade for reinforced cement concrete work including pumping of R.M.C from transit Mixer to site of laying ,excluding the Cost of Centering,Shuttering finishing and reinforcement including cost of admixtures in recommened proporatoons as per IS :9103 to accelerate /retard setting of concrete ,improve workability without inpairing strength and durability as per direction of the nominated BOO (In Coulmn, Slab, Sunshade, Slab Beam, Lintel and Sunshade)
Centering and shuttering including strutting, propping etc. and removal of form work for Columns, Pillar, Piers, abutments, Post and Struts and Wall
Centering and shuttering including strutting, propping etc. and removal of form work for Suspeneded floors, roofs, landings, balconies and acess, Sunshade
Centering and shuttering including strutting, propping etc. and removal of form work for Lintels,beams,plinth beam,Slab Beams with Water Proof Ply 12 mm and Lintel and Beam
Steel Reinforcement for R.C.C Work including Straighting ,Cutting,Bending Placing in position
Brick work in (1:6 cement & coarse sand) super-structure above plinth level up to floor Five level including necessary cutting and moulding of bricks as required and also including supply of all material,labour and T&P etc Complete.
Same as in item no. 18 but in 1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of nominated BOO.
Supply of approved M.S Z-Section Windows and Ventilators including supply of all Materials its Fabrication nuts and Bolt,hole fast for Proper Completion of Work as Per Direction of nominated BOO and also including Cost of Handle Stays rod etc and one Cost of Red Oxide Paint Complete in the Respect of Work.
Supply of M.S Grill of a approved quality as per Drawing including Supply of materials ,Fabrication ,Labour ,T&P and also one Coat of red Oxide Paint Complete in all respect as per direction of nominated BOO for Proper Completion of Work at Site .
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of nominated BOO
Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 non Decorative type ,core of block Board construction with frame of 1 class hard Wood and well matched commercial ply veneerinh with vertical grain (a) 35 mm thick including ISI Marked Satinless Steel Hinges
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Fixing of Door ,Window & Ventilator i/c Labour and T&P etc Complete door chaukhats
Fixing of Door ,Window & Ventilator i/c Labour and T&P etc Complete Window chaukhats
Fixing of Door ,Window & Ventilator i/c Labour and T&P etc Complete ventilator chaukhats
Supply & Fixing of Stainless Steel Door Fitting including Supply of Necessary Screw etc Complete Stainless Steel Sliding Bolt (250 X 16 mm)
Supply & Fixing of Stainless Steel Door Fitting including Supply of Necessary Screw etc Complete Stainless Steel Tower Bolt (300 X 10 mm)
Supply & Fixing of Stainless Steel Door Fitting including Supply of Necessary Screw etc Complete Stainless Steel Tower Bolt (250 X 10 mm)
Supply & Fixing of Stainless Steel Door Fitting including Supply of Necessary Screw etc Complete Stainless Steel Handle 125 mm
Supply & Fixing of Stainless Steel Door Fitting including Supply of Necessary Screw etc Complete Stainless Steel Stopper
Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality
12/15 mm thick Plaster of 1:6 Cement,Coarse Sand Mortar including supply of all Material,Labour and T&P etc Complete.(Outer Plaster)
12/15 mm thick Plaster of 1:6 Cement,Coarse Sand Mortar including supply of all Material,Labour and T&P etc Complete.(Inner Plaster)
Making grooves 10 to 12 mm wide x 8mm deep in plaster of the wall or in ceiling vertically or horizontally as required.
Making Drip Course in sunshade or Facia as per direction as Engineer in Charge including supply of all Material ,labour etc Required for Proper Completion of the Work .
Providing and Laying Ceramic Glazed Floor Tiles of Size 300x300 mm (Thickness to be Specified by the Manufacture ) of approved make in colours such as White ,Ivory ,Grey,Fume red Brown,laid on 20 mm thick cement mortar 1:4 (1 Cement : 4Coarse sand) and Jointing with grey cement slurry @ 3.3 kg/Sqm including Pointing the joint with White Cement and Matching shade Complete .
Providing and Fixing Ist Quality Ceramic glazed wall tiles conforming to IS 15622 (Thicknees to be Specified by the Manufacture of approved make in all Coplours shade Except burgundy ,Bottle green black of any size as approved by nominated BOO in skirting risers of steps and dados over 12 mm thick bed of cement Moratr 1:3 (1 Cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including Pointing in white Cement mixed with Pigment of matching Shade Complete.
Providing and laying Vitrified tiles in diffrent Sizes (thickness to be Specified by Manufacture ) with Water absorption less than 0.08% and conforming to IS 15622, of approved make in all colours & shade in skirting riser of steps over 12 mm thick bed of cement mortar 1:4 (1 cemrent : 4 coarse sand) Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with White Cement & Matching pigment etc complete Size of tile 600 x600 mm .
25 mm thick Kota Stone Flooring over 20 mm(average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 (1 Cement :4 coarse sand)
Providing and Laying of 18 mm thick Granite stone slab mirror polished quarter rounded with anti skid lines in treads of staircase full length flooring over 20 mm (average) thick base laid over and jointed with cement slurry mixed with pigment to match the shade of including rubbing & polishing complete with base of cement mottar 1:4 (1 cement : 4 coarse snad) etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls With Exterior emulsion paint (apex) of approved brand and manufacture and of required shade on undacorated wall Surface to give even shade over @1.25 Ltr/10Sqm including one coat of primer applied @ 0.7 ltr/10 sqm coat curing and coat of all material,labour ,T&P etc Required for proper Completion of the work for two Coat.
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on Inneral Wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inner walls)
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Ceiiling )
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Providing and applying of Two coat Enamel Paint on Metal Surface with Priming Coat including Supply of all Material ,Labour and T&P etc Complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by nominated BOO over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by nominated BOO to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required .Same as above but for European type W.C. pan with white plastic seat and lid.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required a) Range of two half stall Urinal with 5 Litre P.V.C Automatic Flushing Cistern
Providing and fixing 18 mm thick granite ,Mirror Polished ,Premoulded and Prepolished Machine cut for Kitchen Plateform ,Vanity counters window sills ,facias and similar locations ,of required size ,approved shade colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 Cement : 4 Coarse sand ), Joints treated with white Cement mixed with match rubbing,curing,moulding and polishing to edges to give high gloss finish etc Complete at all Levels.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.in staff Toilet
Providing and fixing Counter wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass tap.
Providing and fixing white vitreous china padestal for wash basin completely recessed at the back for the reception of pipes & fittings.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe -32 mm dia
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by nominated BOO.-15mm nominal bore
Providing and fixing C.P brass Ablution health faucet assembly With 1.0 m long braided PVC hose with mountling bracket fixed on wall complete of approved brand or Make.
Providing and fixing C.P Brass Toilet Paper Holder,Jaquar Essco,Cera ,hindware or equivalent to fit the Wall .
Providing and fixing C.P Soap dish ,Jaquar, Essco,Cera ,hindware or equivalent to fit the Wall .
Providing and fixing C.P Brass towel Ring,Jaquar Essco,Cera ,hindware or equivalent to fit the Wall . (For Wash Basin )
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms (For Wash Basin )
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . Single socketed pipes for 110mm diameter
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning, rounding the edges and making and finishing the outlet complete.
Providing and fixing unplasticised -PVC pipe clips I/C Nail/Screw.a) 110mm per Meter
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° -110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Shoe (Plain) -110 mm Shoe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nominal size) all- round P.V.C pipes including bed concrete as per standard design 110/90 mm
Supply of Single Socketed P.V.C Pipe Type -B 90 mm P.V.C Pipe
Supply of Single Socketed P.V.C Pipe Type -B 110 mm P.V.C Pipe
Supply of P.V.C Pipe Fittings Nahani Trap 110 X90 mm Without Jali
Supply of P.V.C Pipe Fittings Round Jali
Supply of P.V.C Pipe Fittings Plain Tee -90 mm
Supply of P.V.C Pipe Fittings Plain Tee -110 mm
Supply of P.V.C Pipe Fittings Door Tee -90 mm
Supply of P.V.C Pipe Fittings Door Tee -110 mm
Supply of P.V.C Pipe Fittings Bend -90 mm
Supply of P.V.C Pipe Fittings Bend -110 mm
Supply of P.V.C Pipe Fittings Door Bend -90 mm
Supply of P.V.C Pipe Fittings Door Bend -110 mm
Solvent
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of nominated BOO Exposed on wall (Internal work) 25mm dia nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of nominated BOO.Concealed work, including cutting chases and making good the walls etc. 20mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of nominated BOO.Concealed work, including cutting chases and making good the walls etc. 25mm dia nominal Bore
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. Exposed on wall 50mm dia nominal bore
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions 15mm nominal bore
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931, 15mm nominal bore
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 15mm nominal bore
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931, 15mm nominal bore- Single Valve
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931, 15mm nominal bore- Double angle Valve
Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of nominated BOO.
Providing and fixing gun metal gate valve with wheel of approved quality, 25mm dia nominal bore
Providing and fixing gun metal gate valve with wheel of approved quality, 50mm dia nominal bore
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m, Pipes 80mm to 300mm diameter.
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround P.V.C Pipes including bed concrete as per standard design 150 mm diameter
Providing and Fixing of UPVC Water Pipe Type B including Jointing With Seal Ring Complete with all Respect 160mm diameter
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 500 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
M/L for constructing Septic Tank for 50 User Septic Tank as per design and drawing provided by OFC all as directed (Work comprises excavation of earth, brick work with 1:4 cement mortar, lean concrete 1:4:8 RCC work of grade 1:1.5:3 with Cover, Main Hole cover with MS work, 15mm thick 1:3 cement plaster on wall and floor complete) size of Septic Tank 3.56m x 2.42m x 2.35m depth.
M/L for construction of soak pit of dia 3.26m x 2.50m hight (Work comprise earth work execavation lean concrete 1:4:8 brick work with 1:4 cement sand RCC cover MS work in RCC cover and filling of brick bats all as directed and work will be executed as per drawing given by OFC).
Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrand single core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with modular type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash
Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit with two number two way modular type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash
Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit with modular type switch, G.P. Box & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash.
Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit with modular type switch & socket etc, complete in all respect including matching colour wash.
Wiring point for call bell with 1.5 sqmm.FRLSH PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire drawn inside the conduit with modular type bell push or 2 pin socket etc complete in all respects including matching color wash
Supply fixing and concealing of 25mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge ( T.V. /Telephone)
Supply & wiring of submains with two number 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
Supply & wiring of submains with two number 4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick) PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copper earth contunity wire including colour wash etc. complete in all respects.
Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in 32 mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 6 sq.mm.FRLSH PVC insulated copper conductor cable as earth contunity wire including colour wash etc. complete in all respects.
Supply and wiring of submain with two number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand single core copper conductor cable in 20 mm dia. heavy duty (2 mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multi strand core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect.
Supply and fixing of 12 watt to 15 watt indoor recess mounting LED square Fitting for armstrong Ceiling having Powder Coating die cast aluminium housing with extended heat sink,diffuser of polycarbonate material and driver set complete in all respect Cat AAA.
Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. CAT-AAA
Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect. CAT-AAA
Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep
Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG board brass including connection etc. as required.
Supply and burying safe earthing Electorde T-19 (Hot Dip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25, terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Gavanized up to 100 mircon filled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaning capacity along with 30 cm squre C.I. frame with hinged cover & masonry housing (from electode terminal to switch board , cost of 25 x 3 G.I. strip will be extra) Make: As approved in U.P.P.W.D. & C.P.R.I. Certified
Supplying & Laying of 25mmx3mm G.I. Strip from earth electrode in ground as required complete in all respects.
Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 6 - 32 amps.Cat. A
Supply and fixing of 6 Amp to 32 Amp DP MCB(10KA)C Curve 32 Amp. DP MCB(10KA) C Curve-Cat. A
Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT A
Supply and fixing of surface/ flush mounting 4 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by nominated BOO. CAT A
S/F of surface/flush Mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respet, as directed at site by nominated BOO.Cat -A
Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects.
Supply and fixing of single pole MCB blanking plate -CAT A
Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T & P etc required for proper completion of work.
Supply & fixing of Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respects as per direction and satisfaction of nominated BOO.
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work.
Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of nominated BOO of work.
Supply and fixing of surface/ flush mounting 6 ways V TPN distribution board with additional metal door without MCB complete in all respect, as directed at site bynominated BOO. CAT-A
Supply and fixing of 100 Amp 4 pole MCCB(25KA) Theramal Magnetic reaease Cat. A
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sqmm 2 core
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 sqmm 3.5 core
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of nominated BOO, 25 sqmm 3.5 core
Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of nominated BOO, 25 Sq mm
Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules.
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.
Supply and fixing 100 AMP four pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of nominated BOO.
Supply and fixing of LED street light fitting having die cast aluminium body and diffuser/reflector with driver set suitable for 75 watt to 90 Watt confirming to IP 66 protection complete in all respect. CAT-AAA
Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required 100 mm Dia
Supply of AC 230/250 Volts ,50 Hz 55w 1400 rpm exhaust fans including providing nuts,bolts,mounting frame and other accessories including connections etc complete as required Make: Havells-Standard-Refresh Air -SPS 300 mm sweep
S/F of led Bulb 9 Watt
S/F of cable,wire,Lugs & cable glnd etc, misc, item
Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply & Installation of split Direct Expansion Air -Conditioners suitable for operation on A/C supply single phase 50 HZ 230 Vots with hermetically sealed compressor with air cooled condenser with DC inverter technology motor capacitor and start run capacitor relay and over load protector internal unit be placed outside the room on terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall Chorded/Cordless) suitable Capacity 3 core sheathed/PVC Copper cable and a better operated wireless remote unit.2.0 TR BEE star rated : 5 Star EER 3.4
Providing & Installation of 5 KVA wall mounted voltage stabilizers with TDR &range of 130 -280 V of standard make, Inmag, servel, stambh.
SRG TILES INDUSTRIES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .