Loading…
Loading…
Tender ID
Tender Value
₹8.3 L
EMD Value
₹16,513
Closing Date
7 Feb 2026, 1:00 pmClosed
EE-I,WKED,PWDte.
New Secretariat Building, C Block, 4th floor 1, K.S Roy Road, Kolkata-700001
Supply, Installation, Testing and Commissioning of Air Conditioning system at the Registrar-in-solvency Department, 1st floor, Main Building of the Honble Calcutta High Court.
2026_WBPWD_994291_1
WBPWD/EE-WKED/NIT-14/2025-26 (2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Percentage
30 days
High Court, Calcutta
Please refer Tender documents.
5 documents required · 5 mandatory
₹16,513
20 Feb 2026
27 Jan 2026
9 Feb 2026
27 Jan 2026
7 Feb 2026
27 Jan 2026
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make : Havells/L&T/Standard/ Siemens as approved by E.I.C)
160 A Main Switch on Angle iron frame [D-3/4(a)]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Legrand/L&T/ABB/ Siemens as approved by E.I.C)
Up to 160A 6 way [D-11/15]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs /enclosure and necessary connection (Make Legrand/ L&T/ ABB/ Siemens as approved by E.I.C)
125A FP MCCB [D-8/10]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ ABB/L&T as approved by E.I.C)
63 Amp TP MCB [D-6/7]
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/ beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)
25 mm dia 3 mm thick Polythene Pipe [E-2/1(c)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required( E-14,1(a))
4 x 6 sq.mm. +2 x 4 sq.mm (E-14, 1(b)(v))
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/ surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(d)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
For 4 core upto 70 sqmm [F-4/7(c)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
3½ core 70 sqmm cable [F-5/8(b) (xvii)]
Supply of 4 Core XLPE Insulated & Sheathed Armoured Al. Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make : Polycab/Gloster/KEI/ Havells / RR Cable]
4 Core 70 Sqmm
Supplying & Drawing 1.1Kv single core stranded 'FR' PVC insulated & unsheated single core stranded 1*35 Sqmm copper cable [Make :Havells/KEI/Polycab/Gloster/Finolex as per approved by EIC] for interconnection between cable end box to VTPN including finishing the terminals with proper copper socketing (Dowels make), tapes, anticorrosive paste & jointing materilas as per GS.
S & F 3phase , 415 V, 50Hz DOL starter with encloser Relay range 9-14 amps (Make-ABB/Siemens/L & T as per dierction of E.I.C) to be fixed on wall with all fixing accessories complete as to G.S
Supply & laying 1.1 KV grade 4 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from DOL starter to three phase A.C outdoor Connection) (make: Havells/KEI/Polycab/Finolex as per approved by EIC)
Supply & laying 1.1 KV grade 2 core 2.5 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from DOL starter to three phase A.C outdoor as earth wire Connection) (make: Havells/KEI/Polycab/Finolex as per approved by EIC)
Supply of Microprocessor based air-cooled ceiling Concealed type split Air Conditioner comprising of indoor unit,outdoor unit having both condensing and cooling unit made of Cu tubes having cooling capacity not less than 14000W, ISSER ratio:- 2.7 to 3.4, Noise level not more than 57db with scroll/rotary Compressor suitable for R-410A/R-32 Refrigerant & operation on 415V - 50 Hz - 3 Ph AC supply.(Make-Mitshubishi Heavy Industries/O-General /Mitsubishi Electric//Daikin/Carrier as per approved by EIC/authority).
Installation, testing & commissioning of the above-said AC outdoor unit on existing Iron Structure and Indoor unit to be suspended below the celling after fastening the full threaded 8mm dia MS rod in the ceiling incl. all fixing accesories as per requirement of the site & mending good the damages as per direction of E.I.C.
Supply & Laying of 4core 2.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Ceiling Concealed split AC machine. (Polycab/Gloster/Finolex/KEI/ Havells /RR Cable )
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 3/8"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.
Supply & Laying 20 mm hard PVC pipe (heavy type) for water drainage.
Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the existing wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC.
Supplying,fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming conforming to IS-15778:2007 with all necessary accessories, specials viz. socket, bend, tee, union, cross,elbo,nipple,longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps,including cutting pipes, fitting,fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (i) 32mm [common header for AC drain pipe line]
S&F of 32A timer controlled DB for 1 no. three phase AC in SS double door 14 way DB enclosure (Make : L&T/ Legrand/ ABB (E)) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish. All connections should be made by copper wire of 4 sq. mm. & 1.5 Sq. mm. and finishing with dowells solderless socket by crimping method incl. necy. connection & provision for earthing attachment & neutral link incl. Ferruling & marking with S & F following Electrical accessories as per direction of EIC [for 3/4 TR AC] i) 415V, 32A FPMCB C curve breaking capacity 10kA - 1 no. ii) 415V, 32A, 3P Contactor with 1 no. + 1 no. Auxilary Contact - 1 no. iii) 32A, 250V AC ON-OFF-ON SPDT toggle switch with marking-1no. (for Auto/Manual option). iv) 24Hr x 7 days programmble Digital timer - 1 no. v) On & Off Indicator LED lamp and Start & Stop push button switch (G&R)-2 set. vi) Din rail mounted Terminal Block for Outgoing & Incoming - 7 nos. vii) 6-32 A SP MCB C curve breaking capacity 10kA-1 no.
Add. G.S.T.@ 18% on total of item
Add. LWC.@ 1% on total of item
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.37 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
BOQ_2432488.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .