Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹3.4 Cr Quoted ₹3.5 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹3.6 Cr+₹10.7 L (3.06%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | ₹3.6 Cr+₹10.7 L (3.06%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹4.1 Cr+₹64.2 L (18.4%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹4.1 Cr+₹64.2 L (18.4%) | L3 | Rejected-Finance Other than being lowest |
| Sl No | Description | Qty | Unit | the bhimani group of companies L3 | RS Enterprises L2 | AGRAWAL ASSOCIATES L1 |
|---|---|---|---|---|---|---|
| 0.00PHASE-1 | ||||||
| 1.00 | SCHEDULE 'A' PART I (B/R WORKS)
Material & labour for providing and erecting at site self supported steel H- Frame Scaffolding for structural repairs of column with micro concrete or columns jacketing with cross bracings of good quality without dents and corrosion to reach place of work including approaches, extension, working platform ladders, lifting tackle necessary wall anchors for men and materials till completion of all structural repair items of work and curing period etc. complete. The work should be carried out with all the safety belt and adequate labours insurance under the supervision of qualified supervisor this item should be used only for structural repair work for entire period of building. (Payment should be only once irrespective of duration of scaffolding.) etc complete. | 2,495 | Sqm | 160 ₹3,99,200 | 180 ₹4,49,100 | 100 ₹2,49,500 Lowest |
| 2.00 | Material & labour for providing and fixing 6mm thick plywood to covering external windows including necessary backing framework to shield windows from falling debris upto 30m height and removing and taking away the material after completion of work including making good any incidental damage(s) to the existing building or its finishes complete all as per the directions of Engineer-in-charge.
Note - i) The covering material shall be the property of contractor after completion of work and removing outside MD land.
ii) The measurements for payment shall be made in terms of the area protected by such covering for the complete duration of the work in Phase-I. (In case of any damage the same shall be replaced by the contractor at extra cost to the govt) | 50 | Sqm | 290 ₹14,500 | 100 ₹5,000 Lowest | 500 ₹25,000 |
| 3.00 | Material & labour for providing and erecting external safety Net of opening 75mm x 75mm in addition vertical fisher net arrester on the first floor and vertically throughout to prevent debries failling while execution of work, to hold / absorb the debries stone impact during the entire period of work. The work shall be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisior and removing after completion of work complete all as per the directions of Engineer-in-charge. | 2,373 | Sqm | 150 ₹3,55,950 | 100 ₹2,37,300 Lowest | 125 ₹2,96,625 |
| 4.00 | Material & labour for providing, erecting, maintaining and removing temporary protective screens made out of specified fabric upto 30m height or CGI/pre-painted GI sheet with all necessary fixing arrangement/ MS framing work as per ground situation including necessary beading of thread & including G.I. rings to ensure that it remains in good serviceable condition & position for the work duration as required by Engineer in charge. (a) Woven PVC / HDPE Cloth. Note: Payment shall be made for actual flat area of wall and for once only for the complete duration of the work in Phase-I. (In case of any damage the same shall be replaced by the contractor at extra cost to the govt) The cloth/GI sheet will be the property of agency after completion of work & must be removed from the premises after completion of work in phase-I as per direction of Engineer-in-charge. | 2,373 | Sqm | 400 ₹9,49,200 | 75 ₹1,77,975 Lowest | 200 ₹4,74,600 |
| 5.00 | Carefully tapping with light hammer the hollowness / De-bonded plaster and chipping the same with chisel after demarking and cutting the boundary grooves by electric cutting machine including removal of debris. | 211.6 | Sqm | 40 ₹8,464 Lowest | 100 ₹21,160 | 100 ₹21,160 |
| 6.00 | Breaking carefully the loose concrete of distressed member without damaging existing strong concrete by means of sharp chisel which should tempered regularly of high frequency low impact hammer is used, cleaning the surface by water jet pressure pump at 4 to 5 kg/ sq.cm pressure to remove chlorides and loose partials, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labor insurance under the supervision of qualified supervisor. (The damaged ceiling / concrete will be measured) etc... Complete | 1,185 | Sqm | 40 ₹47,400 Lowest | 90 ₹1,06,650 | 50 ₹59,250 |
| 7.00 | Providing and erecting steel tubular props of required height up to 14' feet, L head or flat head braced at center and supporting a continuous 2"X 3" wooden runner , resting on wedge and block minimum capacity 3 Ton to support the structure provisionally during repair and jacketing etc. and maintain them in position till required item etc. complete. The props are erected in perfect vertical in plumb taking /transferring the load equally/ uniformly. The location of every prop should be one over another floor and it should not be eccentric. The tightening of every prop should be uniform to all props to strain the building uniformly, removing the same as and when directed by structural engineer/ site Engineer. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor and remove the same completion of work etc. complete. | 300.3 | Each | 400 ₹1,20,120 | 210 ₹63,063 | 200 ₹60,060 Lowest |
| 8.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for without disturbing structural element and removal of debris out of MD land complete all as specified.
Note: The place of disposal shall be find out by the contractor. | 2.9 | Cum | 500 ₹1,450 | 1,500 ₹4,350 | 300 ₹870 Lowest |
| 9.00 | Demolition of RCC work i.e. pardi, roof, floor, beam, staircase, landing, chajjas & wall manually/by mechanical means without disturbing structural element including reinforcement cut as required to facilitate demolition and separating, scraping and cleaning of reinforcement and removing debris outside MD land.
Note: The place of disposal of material shall be the responsibility of the contracts and rate shall be included in the rate quoted by the bidder. | 1 | Cum | 500 ₹500 Lowest | 1,000 ₹1,000 | 500 ₹500 Lowest |
Tender Value
₹4.3 Cr
EMD Value
₹5.1 L
Closing Date
10 Jul 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIRS TO P-01 BUILDING (NOORBHOY) AT INS ANGRE UNDER GE (NW) KUNJALI.
2025_MES_708818_1
8458/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
730 days
GE (NW) Kunjali
Class A
Category a (i) and b (i)
8 documents required · 8 mandatory
₹2,000
GE (NW) Kunjali
₹5.1 L
Yes
25 Sept 2025
17 May 2025
12 Jul 2025
17 May 2025
10 Jul 2025
28 Jun 2025
17 May 2025 - 6 Jun 2025
Amount
PHASE-1
SCHEDULE 'A' PART I (B/R WORKS) Material & labour for providing and erecting at site self supported steel H- Frame Scaffolding for structural repairs of column with micro concrete or columns jacketing with cross bracings of good quality without dents and corrosion to reach place of work including approaches, extension, working platform ladders, lifting tackle necessary wall anchors for men and materials till completion of all structural repair items of work and curing period etc. complete. The work should be carried out with all the safety belt and adequate labours insurance under the supervision of qualified supervisor this item should be used only for structural repair work for entire period of building. (Payment should be only once irrespective of duration of scaffolding.) etc complete.
Material & labour for providing and fixing 6mm thick plywood to covering external windows including necessary backing framework to shield windows from falling debris upto 30m height and removing and taking away the material after completion of work including making good any incidental damage(s) to the existing building or its finishes complete all as per the directions of Engineer-in-charge. Note - i) The covering material shall be the property of contractor after completion of work and removing outside MD land. ii) The measurements for payment shall be made in terms of the area protected by such covering for the complete duration of the work in Phase-I. (In case of any damage the same shall be replaced by the contractor at extra cost to the govt)
Material & labour for providing and erecting external safety Net of opening 75mm x 75mm in addition vertical fisher net arrester on the first floor and vertically throughout to prevent debries failling while execution of work, to hold / absorb the debries stone impact during the entire period of work. The work shall be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisior and removing after completion of work complete all as per the directions of Engineer-in-charge.
Material & labour for providing, erecting, maintaining and removing temporary protective screens made out of specified fabric upto 30m height or CGI/pre-painted GI sheet with all necessary fixing arrangement/ MS framing work as per ground situation including necessary beading of thread & including G.I. rings to ensure that it remains in good serviceable condition & position for the work duration as required by Engineer in charge. (a) Woven PVC / HDPE Cloth. Note: Payment shall be made for actual flat area of wall and for once only for the complete duration of the work in Phase-I. (In case of any damage the same shall be replaced by the contractor at extra cost to the govt) The cloth/GI sheet will be the property of agency after completion of work & must be removed from the premises after completion of work in phase-I as per direction of Engineer-in-charge.
Carefully tapping with light hammer the hollowness / De-bonded plaster and chipping the same with chisel after demarking and cutting the boundary grooves by electric cutting machine including removal of debris.
Breaking carefully the loose concrete of distressed member without damaging existing strong concrete by means of sharp chisel which should tempered regularly of high frequency low impact hammer is used, cleaning the surface by water jet pressure pump at 4 to 5 kg/ sq.cm pressure to remove chlorides and loose partials, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labor insurance under the supervision of qualified supervisor. (The damaged ceiling / concrete will be measured) etc... Complete
Providing and erecting steel tubular props of required height up to 14' feet, L head or flat head braced at center and supporting a continuous 2"X 3" wooden runner , resting on wedge and block minimum capacity 3 Ton to support the structure provisionally during repair and jacketing etc. and maintain them in position till required item etc. complete. The props are erected in perfect vertical in plumb taking /transferring the load equally/ uniformly. The location of every prop should be one over another floor and it should not be eccentric. The tightening of every prop should be uniform to all props to strain the building uniformly, removing the same as and when directed by structural engineer/ site Engineer. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor and remove the same completion of work etc. complete.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for without disturbing structural element and removal of debris out of MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Demolition of RCC work i.e. pardi, roof, floor, beam, staircase, landing, chajjas & wall manually/by mechanical means without disturbing structural element including reinforcement cut as required to facilitate demolition and separating, scraping and cleaning of reinforcement and removing debris outside MD land. Note: The place of disposal of material shall be the responsibility of the contracts and rate shall be included in the rate quoted by the bidder.
Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work & precast concrete articles including copings etc.and removing debris outside MD land complete all as specified. Note: The place of disposal of material shall be the responsibility of the contracts and rate shall be included in the rate quoted by the bidder.
Material & labour for cleaning the existing reinforcement with hammer tapping and cleaning with wire/rotary wire brush fixed to hand drill machine, making the surface free form loose corrosion material, dirt, scaling etc. and applying two coats of polymer based alkaline rust converting primer conforming to ASTM-B 117 by means of brush with time interval of 1 hour between two coats, The product should converts the rust in to stable organo metallic complex molecule layer, this should also act as primer to further treatment of steel complete all as per manufacturers instructions and with approved applicator as directed by Engr-in-charge. Note - The work shall be carried out with safety belt, helmet etc. and adequate labour insurance under the supervision of qualified supervisor.
Material & labour for anticorrosive treatment with two coats of IPNET-RB (CBRI known how) on exposed reinforcement by means of brush with time interval of 4 hours between two coats and shall be allowed to dry for further treatment complete all as per manufacturers instructions and with approved applicator as directed by Engr-in-charge. Note - The work shall be carried out with safety belt, helmet etc. and adequate labour insurance under the supervision of qualified supervisor.
Material & labour for providing and applying two coats of concrete penetrating hi- tech corrosion inhibition mechanism inhibits corrosion of steel in concrete at the poles, cathode & anodic simultaneously on concrete surface which is prepared earlier complete all as per manufacturers instructions and with approved applicator as directed by Engr-in-charge. Note - The work shall be carried out with safety belt, helmet etc. and adequate labour insurance under the supervision of qualified supervisor.
Material & labour for replacing distressed/ loose/ cracked/ porous carbonated. Loose part of concrete and repairing the damaged surface of concrete, fixing the formwork/ structural element, pouring the free flow ready mix micro concrete mix with 5 litres to 7 litres of water in the formwork. Microconcrete should be mixed in steel tray homogeneously to a consistency based on type of structural element and its location. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc complete all as specified and directd by the Engr-in-charge.
Material & labour for providing formwork to sides and soffits of floor, roof beams, pillars, posts struts, piers, columns and stanchions etc also splays between floors and beams, etc. for rough finished surfaces of concrete flat complete all as specified.
Material & labour for Providing and applying jacketing around columns/RCC members for casting distressed / loose/ cracked/ damaged surface of concrete , fix the form work/ structural element, pour the free flow ready mix micro concrete ( with water to microconcrete ratio of 1:8 or as per manufacturers instructions ) in the form work. Micro concrete shall be mixed in mechanical mixing vessel to achieve a homogeneous blend as per requirement of structural element and its location complete all as per manufacturers instructions and with approved applicator as directed by Engr-in-charge. Note - The work shall be carried out with safety belt, helmet etc. and adequate labour insurance under the supervision of qualified supervisor.
M&L for providing and applying 15 mm thick polymer mortar to load carrying RCC member in two layers (10 mm + 5 mm) in proportion of 1:5:15 by weight, of approved polymer, cement and washed quartz sand conforming to IS- 383 with required consistency for desired floating,mixed in a mechanical mixer including curing complete all as maufacturer's instruction and as directed by the Engr-in-charge
Making up lost section of concrete / mortar with thixotropic repair mortar is one component thixotropic dual shrinkage compensated fiber reinforcement formulation for structural members. Build up section by hand packing as per manufacturers specification, applied by mean of hand glouse by expert applicator, the rehabilated surface should be free from air gaps, voids should be in line with existing required line and line with existing surface, including curing, cleaning the area etc. complete. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc. complete.
Providing and Fixing Shear connectors of 8mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing Cylinder-in-cartridge form that avoids site mixing using standard sealant applicator gun after drilling holes of 12mm diameter to a minimum depth of 100mm at required locations, inclusive of all material, manpower and equipment.
M&L for Reinforced cement concrete M-30 (20 mm graded crushed stone aggregate) as in roof slab, roof beams, columns etc complete all as specifed and directed by the Engr-in- charge
M&L for TMT CRS bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with the clips complete all as specified .
M&L for TMT CRS bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by the Engr-in- charge
Providing and applying approved epoxy resin EPI Bond of Krishna conchem or equivalent before polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C- 882-87 using nylon brushes scaffolding labour etc. complete.
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. complete.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for existing shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and getting out in hard/ dense soil complete all as specified and directed
Removing excavated hard/ dense soil n exc 250 m and depositing where directed at a level n exc 1.5 m above starting point complete all as specified and directed
Material & labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 14mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 mm center to center in staggered manner or as directed by Engr-in-charge and work shall be carried out as under :- (i) Cleaning of holes by air blower prior to fixing nozzles. (ii) Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cut the nozzles by chisel after completion of grouting without damaging structural elements.
Providing and Injecting the fixed packer two-component low viscosity (<350 cps) epoxy resin system that achieves compressive strength in excess of 55 MPa at 1 day & 65 MPa at 7 days. and shall exceed 15 MPa in slant shear bond strength with minimum pot life of 30 minutes at ambient temperatures complying with ASTM C881, Type 1 & 4, Grade 1, Class B &C using any of the standard pressure grouting methods at a maximum pressure of 2kgs/sq.cm. till refusal and allowing the epoxy grout to cure before removal of packers inclusive of cost of Material, Manpower and Equipment.
Providing and Injecting high performance non shrink, free from high strength antiwash Polymer Cement Grout by addition of water as per manufacturers specification into hoeycombing area/ porous concrete including drilling of holes minimum 50 mm in concrete, fixing nipples, injecting grout by suitable pump at pressure of 2.0 kg/cm2 and subsequently cutting/ removal of nipples and sealing of holes with epoxy putty EPW 1010 etc. complete as directed by Engineer-in-charge.
Drilling and fixing 8mm,10mm re-bars with 'Fischer/Hilti' system and chemical, etc. Steel to be paid sepreatly.
(a) 12mm dia bars
(b) 10mm dia bars
(c) 8mm dia bars
Removing existing water proofing treatment such as I.P.S./Brick bat coba etc. from terrace/toilet sunken portion without damage to structure, levelling and cleaning the surface for providing new specialised water proofing treatment complete.
M&L for PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) cement concrete as a leveling course on roof surfaces and coping etc.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) cement concrete as a leveling course on roof surfaces and coping etc.
M&L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) cement concrete as in floor finished even and fair complete all as specified and directed bh the Engr-in-charge
M&L for cement concrete 1:3:6 type C-1 , (20 mm graded stone agg) as in foundation filling and sunken floors etc all as specified and directed.
M& L for Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
M&L for Brick work work with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Material & labour for rendering 20mm thick polymer modified ready mix cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/ final coat. Polymer modified ready mix cement based plaster should having minimum compositionof 1:5:15 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external wall plastering having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good, consistency as per manufacturer's specification including using richer mix for making corners complete all as specified and directed
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished even & smooth without using extra cement completed all as specified.
M&L for rendering 5 mm thick on fair faces of concrete surfaces in ceiling in cement mortar (1:3) and finished even and smooth without using extra cement complete all as specified.
M&L for preparing new plastered surfaces of wall, soffits, facia roof and applying two coats of weather proof acrylic exterior paint (100% Acrylic) over a coat of self primer complete all as per manufactures instructions and directed by Engineer-in-Charge. Note : Area of Porbandar or Malad stone cladding shall be deducted
Supply only integral water proofing compound.
M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified.
M&L for preparing new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified.
Material & labour for complete removal of existing treatment including washing, rubbing down and stopping of distempered and painted wall surfaces, filling holes and cracks with filling putty and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified..
M&L for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper complete all as specified and directed
M&L for applying one coat of wall care putty not less than 2mm thickness and making the surface even and smooth using emery paper complete all as specified and directed by Engineer-in- Charge. .
M&L for preparation of old decorated surfaces of ceiling and applying one coat of oil emulsion distemper complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets etc complete all as directed.
M&L for false ceiling work of aluminium anodized ceiling grid system of grid size 605mm x 605mm made out of aluminium anodised main and cross tee of size15mm x 15mm x 1.5mm thick, weighing 0.12 Kg per running metre and wall angle of size 40mm x 25mm x 2mm thick, weighing 0.36 Kg per running metre. conforming to designation 3600 given in IS 207-10985 including ceiling cleats screwed with 6 mm dia. G.I. suspender hangers (upto 1200mm length) fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.
Supply and fixing min 12 mm thick perforated particle board/ tiles for insulation and accoustic purpose of size 600mm x 600mm fixed in snap grid ceiling, flat or sloping complete all as specified and directed. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.6, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 mm X 600 mm suitable for Green Building application, with Recycled content of min 25%.
Supply and fixing non asbestos fibre cement building boards 600mm x 600mm x 6mm thick type B, any category as per IS 14862: 2000 (non-asbestos) building boards of approved design and colour fixed or laid/inserted in aluminium grid false ceiling complete all as specified.
M&L for POP false ceiling using 600X900x12 mm thick plaster of paris with gypsum binder sheet decorative type including two coats of plastic emulsion paint and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre, secondary joist of size 75X20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2 M C/C, including dismantling old unserviceable false ceiling complete all as specified and directed.
Supply and fixing ACP clading (Aluminium Composite Panel) 3 mm thick composed of non combustible virgin LDPE core laminated and sandwitched between two fine aluminium sheets 0.25 mm thick on both sides including folding, cutting with machine and fixed in aluminium frame work made out of aluminium box section of size 25 mm x 35 mm including aluminium or stainless steel rivets, bolts and/ or screws, anchor fasteners and frame work fixed to wall with aluminium clits, screws etc complete as per manufacturers instructions.
Supply and fixing 5mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall vertically with screws to make PVC frame as per manufacturer's specifications and shown on drawing in SSR Part II.
Supply and fixing PVC wall /ceiling paneling consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturers specifications and shown on drawing in SSR Part II.
Taking down chowkat with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each
Taking down chowkat with shutters (without taking off shutters from the frames) area exc 1.5 Sqm but n.exc 4 Sqm each.
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each
Supply and fixing 2nd class hard wood (sal) plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified.
M&L for 35 mm thick second class hard wood plain, framed factory made panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I),kiln seasoned and chemically pressure treated complete all as specified.
Supply and fixing 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides complete all as specified.
Supply & Fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specification and drawings shown in SSR Part II complete all as specified and as directed by Engr-in-Charge.
Supply and fixing 30 mm thick factory made solid panel PVC door shutter (Style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame as per specification and drawings shown in SSR Part II complete all as specified and as directed by Engr-in-Charge.
Supply and fixing powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such as glazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified Note: - (i) Glass panes will be measured & paid separately. (ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight. (iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area. (v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05 and sill to be provided as per HQ CE(N) MZ TD of sill type 'A' and 'B' respectively if directed.
Supply and fixing in repair aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 102, 7.5 mm thick all as specified and as directed by Engr- in- charge.
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple complete all as specified.
Supply and fixing 12mm thick prelaminated medium density particle board, interior grade, prelaminated both sides with decorative choice lamination fixed with screws to aluminium frame work complete all as specified and directed.
Material & labour in repairs 18 mm thick prelaminated water proofing boards suitable for cupboards, drawers etc of approved colour
Supply and fixing stainless steel Auto close hinges for full overlap of cupboard shutters complete all as specified
Supply and fixing SS decorative handles for cabinet/door/drawer of size varying 100 to 200 mm as dirtected.
Supply and fixing stainless steel Sliding channel for cupboard drawer complete all as specified .
Supply and fixing SS locks suitable for cupboard drawers complete all as specified
Supply and fixing aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, 300 mm long , ISI marked complete all as specified.
Supply and fixing aluminium anodised barrel tower bolts of extruded section, 200 mm length, ISI marked.
Supply and fixing 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified.
Supply and fixing 100 mm long stainless steel butt hinges medium weight with stainless steel hinge pin, bright finished.
Supply and fixing 125 mm cold rolled mild steel butt hinges medium weight with stainless steel hinge pin, bright finished.
Material & labour for MS work as in holdfast and similar articles conforming to grade Fe 410-0 and Fe 310-0 complete all as specified
Supply and fixing in repairs 140 mm long floor door stopper of aluminium door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as specified
Supply and fixing Aluminium extruded body door closer hydraulically regulated, designation No. 2 universal type, ISI marked, suitable for door shutters up to 701 mm to 850 mm in width and of weight between 36 to 60 kg complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
M&L for rolled mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt elded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed .
M&L for MS framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings etc conforming to Fe.290.Gde-E-165 complete all as specified
M&L for rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to commom rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to grade Fe-290 ( Gde-E- 165) incl one shop zinc chromate primer incl preparation of surfaces complete all as specified and directed by the Engr-in-charge
Supply & Fixing 12mm thick, toughened glass door cut to shape, drilling holes, itching as per design and fitted with and including fitting and fixtures such as SS handles, SS studs, SS fittings for door, SS pivots etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc as specified erected in position and securing runners with holdfasts and brackets complete all as specified SSR part I and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal of debris out of MD land. Note: The place of disposal shall be find out by the contractor.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified.
Dismantling stone slab and tiles of of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc all as specified and directed.
M&L 18-20 mm thick mirror polished Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed.
M&L for machine cut cudappa stone slab 22-25 mm thick fixed independently and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar including removal of rubbish out side MD land. Note: The place of disposal shall be find out by the contractor.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Material & Labour for Non skid coloured ceramic tiles 7 to 8 mm thick (square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm laid in floor over and including 20mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified. Note :Sample from latest catalouge shall be get approved from Engr-in-Charge.
Material & Labour for coloured glazed ceramic tiles 450mm x 300mm x 7-8mm thick but laid on vertical surfaces such as skirting/dado laid over and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile complete all as specified. Note :Sample from latest catalouge shall be get approved from Engr-in-Charge.
Material & Labour for light shade vitrified ceramic tiles of approved colour (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm (600x600mm) and 9 to 10mm thick, in floor laid over and including 20mm thick screed bed in cement mortar ( (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified. Note :Sample from latest catalouge shall be get approved from Engr-in-Charge.
Material & Labour 9-10mm thick double charged vitrified ceramic tiles, premium quality of approved colour (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm (600x600mm), as in vertical surfaces such as skirting/dado etc., laid over and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile complete all as specified. Note :Sample from latest catalouge shall be get approved from Engr-in-Charge.
Supply and fixing in repair for Porbandar or Malad stone cladding gang saw cut with machine cut edges, uniform colour of size exceeding 0.25 sqm but not exceeding 0.5 sqm each tile as in vertical surfaces such as skirting/dado etc., laid over and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile complete all as specified.
Dismantling plain or corrugated steel/AC roof sheets any gauge, thickness, including Nainital or similar pattern roof covering all as specified and directed.
Supply and fixing pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed.
Supply and fixing pre-painted hot- dip aluminium-zinc alloy metallic coated plain steel sheet, corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed.
Taking down PVC soil, waste, vent and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified.
Supply & Fixing 75mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 75mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified.
Supply and fixing 110 mm bore PVC(SWR) bend any radius, fixed with rubber ring joints.
Supply and fixing 75mm bore PVC(SWR) bend any radius, fixed with rubber ring joints.
Supply & Fixing 110 mm bore PVC (SWR) branch piece,single (single Y) equal or unequal fixed with rubber ring joints.
Supply & Fixing 75 mm bore PVC (SWR) branch piece,single (single Y) equal or unequal fixed with rubber ring joints.
Supply & Fixing 110 mm bore PVC (SWR) vent cowl fixed with rubber ring joints.
Supply & Fixing 75 mm bore PVC (SWR) vent cowl fixed with rubber ring joints.
M&L in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement75 mm dia.
Supply & Fixing 160mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 160mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified.
Supply and fixing 160 mm bore PVC(SWR) bend any radius, fixed with rubber ring joints.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in sub base and finished fair and even.
Material & labour for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate ) as in plinth protection and finished fair and even complete all as specified.
Taking up or down old 15 mm bore GI tubing including all connections complete all as specified.
Taking up or down old 20 mm bore GI tubing including all connections complete all as specified.
Taking up or down old 32 mm bore GI tubing including all connections complete all as specified.
Supply and fixing 15mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 including all fittings such as ends, elbows, unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc.and fixed to walls, celing with suitable size saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves or laid in floors complete all as specified.
'-Ditto- all as per item No 128.00 above but 20 mm bore
'-Ditto- all as per item No 128.00 above but 32 mm bore
Supply and fixing in repairs plastic water closet seat white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device complete all as specified.
Supply and fixing in repairs, Plastic water closet seat, black or white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium anodized hinging device complete all as specified.
Supply and fixing in repairs vitreous china squatting pan, ‘Orissa’ pattern of size 580 x 440 mm white, with integral foot rest (excluding flushing Cistern, flush pipe etc) including 'P' or S trap including provision of lime concrete bedding and making all connections complete all as specified.
Supply only cast iron 'P' trap 100mm bore.
Supply and fixing in repair pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 15 mm bore bib taps cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs 15 mm bore angle cock, cast copper alloy, fancy type chromium plated screwed down, high pressure , with lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipes or union.
Supply & fixing in repair wash hand basin vitreous china white (flat back) of size 550mm x 400mm including bracket, 15mm dia PTMPT connections, 32 mm dia brass CP waste coupling and 32mm dia PVC waste pipe 90cm long etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing PVC connections 15 mm size with PTMT nuts of length 600mm
Supply and fixing in repair PVC valveless, syphonic action type, flushing cistern, low level, white 10 ltr capacity with inlet, ball valve, float and handle including brackets and polyethylene flush pipe complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Flush pipe of Polyethylene of low or high density or PVC 32 mm bore suitable for low level flushing cistern
Supply and fixing in repairs soap dish brass CP of standard pattern and fixed to wall with CP brass screws.
Supply and fixing in repairs vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe ) but including PVC waste pipe , providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern trap and waste pipe) complete all as specified.
Dismantling carefully water tank of capacity exc. 500 Ltrs but n.exc. 1000 ltrs.
Dismantling carefully water tank of capacity exc. 1000 Ltrs but n.exc. 2000 ltrs.
Supply and fixing rotational moulded polyethylene water storage tank 1000 Ltr capacity, (cylindrical vertical with closed top) including all connections for inlet, outlet, overflow and washout pipes and 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for inron pipe and fixed (minimum weight 210 grms ) hoisted and fixed in position all as specified in SSR Part-I complete all as specified.
'-Ditto- all as per item No 148.00 above but 2000 Ltr
Supply and fixing in repairs toilet paper holder of viterous china box type white coloured fixed to walls withchromium plated brass screws CP brass fixed to walls complete all as specified and directed.
Supply and fixing in repairs viterous china urinal partition white of size 310 x 700mm urinal partions slabs, terminating about 40cm above floor complete all as specified and directed.
Supply and fixing 2mm thick Linoleum ,plain coloured laid in floors incliding streching, cutting , fitting including seal down with an approved adhesive complete all as specified.
Supply and fixing 16 mm thick perforated particle board/ tiles for insulation and accoustic purpose of size 600mm x 600mm fixed with nails to timber frame work or staples on snap grid for wall complete all as directed.
M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surfaces including a coat of wood filler on old work with two or more coats complete all as specified.
Supply and fixing in repairs health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS hook including making all connections and fixed in position complete all as specified.
Supply and fixing 8 mm thick corner glass shelves half round of average radius 200mm including fixing with D type CP brass brackets and stainless steel railing along edges of shelf complete all as specified and directed.
Supply and fixing in repairs aluminium anodised tubular towel rail 20mm dia D type 60 cm long between flanges complete all as specified
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified
Supply and fixing 4mm thick bakelite sheet with decoratie choice laminated on both sides complete all as specified and as directed.
Supply and fixing in repair under counter wash hand basin vitreous china of size 605mm x 430mm x 200mm oval shape meticulously crafted from high quality materials with seamless finish white fixing with fastner/ bracket including 32mm dia brass CP waste coupling,15mm dia PVC connection with nuts and 32mm dia PVC waste pipe 90cm long and making all connections complete all as specified and as directed Engr-in-Charge.
Supply & Fixing Single Piece vitreous china WC with UF soft close seat cover, Hinges, Fixing Accessories, Accessories Set and Cistern fittings, Size: 370x695x795 mm, S trap-300mm including connecting piece and making all connections complete all as specified and directed by Engr-in-Charge .
Supply and fixing double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium ally sheet foundation box, main body with stainless steel cover, governing pivot made of bras, other parts made of mild steel heavy duty complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from iron frames glazed with putty or wooden beads complete all as specified.
Supply and fixing 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete all as specified.
Material & labour for providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 ltrs per sqm of the vertical surface of the sub- stsructure to a depth of 300 mm including excavating channel along the wall and rodding etc complete all as specified and directed.
Material & labour for providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 ltrs per linear metre including drilling and plugging holes etc in apron.
Material & labour for providing and injecting chemical emulsion for post constructional anti-termite treatment of soil under existing floors using emulsion @ one litre per hole 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1 : 2 (1 cement : 2 coarse sand) to match the existing floors all as specified and directed.
Material & labour for providing and injecting chemical emulsion for post constructional anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution ) @ 0.5 ltr/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same all as specified and directed.
M&L for Vitrified Ceramic tiles dark shade 9- 10 mm thick (square/ rectangular) polished area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm,in floor laid over and including 15mm thick screed bed in cement mortar ( (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified. Note :Sample from latest catalouge shall be get approved from Engr-in-Charge.
Supply and fixing PVC/WPC decorative type wall paneling made of 2/3mm thick designed sheet provided with suitable grooves for joining each other including aluminum frame work fixed to wall and panelling with necessary fixing arrangement as per manufacturers specifications and shown on drawing in SSR Part II.
Supply & fixing hand shower (health faucet) with 1 m long flexible tube with wall hook chromium plated (make- Jaquar Cat No. ALD-CHR-593 & SHA -571 or technocommercial equivalent of make given in Appx 'B')
Supply and fixing in repair 15 mm bore brass two-in-one bib cock cast copper alloy with crutch or butterfly handle screwed for iron pipe or for brass ferrule and fixed (weight not less than 1200 gms)
SCHEDULE 'A' PART Il (INTERNAL ELECTRIFICATION) Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
Material & labour for concealed point wiring with 1.5 sqmm single core multistranded FRLS PVC insulated, sheated copper conductor cable,1100 volts grade conforming to IS- 694:1990 drawn through and including rigid non-metallic PVC conduit medium grade ISI marked with all accessories concealed in wall/ floor and terminated in and including concealed PVC modular metal box with modular white cover plate with frame of sutable size including one FRLS PVC insulated and sheathed multistanded copper conductor cable 1.5 sqmm as earth continuity conductor connected to common earth dolly for the following :- Note : - i) Circuit conductor from MCB DB to Switch boards shall not be less than 2.5sqmm for (a) swich boards having light/fan points and 6A socket in common circuit. (b) socket outlets 6A mounted on Independent switch board. ii) Modular metal flush box is deemed to be included in the unit rate quoted. iii) In colum/beam/ceiling portion surface wiring should be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iv) The work shall be carried out conforming to IS-732:1989. v) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. vi) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
One light point controlled by one 5A switch
One Fan point/Exhaust fan point controlled by one 5A switch
One Bell point control by one 5A bell push switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
Material & labour for concealed point wiring with 2.5 sqmm single core multistranded FRLS PVC insulated, sheated copper conductor cable,1100 volts grade conforming to IS- 694:1990 drawn through and including rigid non-metallic PVC conduit medium grade ISI marked with all accessories concealed in wall/ floor and terminated in and including concealed PVC modular metal box with modular white cover plate with frame of sutable size including one FRLS PVC insulated and sheathed multistanded copper conductor cable 2.5 sqmm as earth continuity conductor connected to common earth dolly for one 3 pin socket outlet 15 Amps on the independent board. Note:- i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. ii) Separate circuit shall be drawn from MCB. No taping from light circuit shall be allowed. iii) Modular metal flush box is deemed to be included in the unit rate quoted. iii) In colum/beam/ceiling portion surface wiring should be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iv) The work shall be carried out confirming to IS-732:1989. v) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. vi) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
Material & labour for concealed point wiring with 4 sqmm single core multistranded FRLS PVC insulated, sheated copper conductor cable,1100 volts grade conforming to IS- 694:1990 drawn through and including rigid non-metallic PVC conduit medium grade ISI marked with all accessories concealed in wall/ floor and terminated in and including concealed PVC modular metal box with modular white cover plate with frame of sutable size including one FRLS PVC insulated and sheathed multistanded copper conductor cable 4 sqmm as earth continuity conductor connected to common earth dolly for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note:- i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. ii) Separate circuit shall be drawn from MCB. No taping from light circuit shall be allowed. iii) Modular metal flush box is deemed to be included in the unit rate quoted. iii) In colum/beam/ceiling portion surface wiring should be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iv) The work shall be carried out confirming to IS-732:1989. v) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. vi) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
Supply and fixing ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified.
Supply and fixing modular switch, 6 Amps , One way, one module, ISI marked complete all as specified and directed.
Supply and fixing modular switch, 16 Amps , One way, one module, ISI marked complete all as specified and directed.
Supply and fixing modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC. Make: Legrand cat part No. 5734 24 or equivalent
Supply and fixing modular socket outlet,6/ 16A,2 module all as specified and directed by EIC. Make: Legrand cat part No. 5734 71 or equivalent
Supply and fixing modular stepped type fan regulators 2 module, 120 W, 230 volts ISI marked complete all as specified and directed.
Supply and fixing modular type bell push 6 amps 1 module, ISI marked complete all as specified and directed.
Supply and fixing bell electric AC 230 Volts single pole ding dong with ISI marked complete all as specified and directed.
Supply and fixing in repairs hanger clamp assembly with down rod up to 3 feet for hanging of ceiling fan with nuts,bolts,washers & split pin complete all as specified & directed by EIC.
Material & labour for disconnecting and taking down carefully ceiling fans of any make and type of sweep 1200mm /1400mm and opening the motor, removing of old grease, cleaning dust properly, heating, varnishing, greasing including testing and refixing in same position and applying two coat white enamel paint over a coat of steel primer by spray pump complete all as specified.
Material & labour for disconnecting and taking down carefully exhaust fan of any make,type and sweep and opening the motor, removing of old grease, cleaning dust properly, heating, varnishing, greasing including testing and refixing in same position and applying two coat white enamel paint over a coat of steel primer by spray pump complete all as specified.
Supply and fixing in repairs new generation adore LED 3 W (min 120 lumen/watt) Deep Spot light with intergal Driver Complete with providing high quality economic energy saving lighting Suitable for fixing in false ceiling complete all as specified.
Supply and fixing in repair Flexible LED strip with high brightness SMD LED as the light source for indoor application suitable for cove-lighting, decorative lighting etc Legth of strip 5 Mtr in each set complete as approved by Engr-in-Charge.
Supply and fixing in repair new generation three in one colour down light 15/18 Watt (min 120 lumen/watt) LED PDC aluminium housing downlights, high quality ecomonic energy saving light complete all as specified and directed.
Supply and fixing in repair new generation ultraslim LED panel recessed LED Luminaire of size 600mm x 600mm, 36 watt, of not less than 125 lumen/watt, CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting Suitable for fixing in false ceiling.
Supply and fixing in repair new generation walll/surface mounted 1x 20W LED batten fitting, 4 feet of not less than 125 lumen/watt, provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as directed by Engr-in-Charge.
Refixing of serviceable LED light fitting such as panel lights, batten fittings or any type obtained from item No. 01 of this schedule with accessories including electrical connection complete all as specified and directed.
Supply and fixing in repair of LED 60W, of not less than 125 lumen/watt, Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified .
Supply and fixing of emergency staircase surface mounted downlighter with battery powered backup operation for 3 hours, 220-240V, 50 Hz having 12x1.5W LED, suitable for operating environmental temp ranging from -5 to 45 degree centigrade complete all as specified and directed.
Supply and fixing of battery powered exit signage LED light fitting, 220-240 V, 50 Hz having 2W LED, with battery backup not less than 3 hours suitable for operating environmental temp ranging from -5 to 45 degree centigrade complete all as specified and directed.
Supply and fixing ceiling fan 230 Volts, 50 Hz, 1200 mm sweep, minimum air delivery 210 CFM with service value 6 BEE, 5 star rated with brushless direct current motor (BLDC) including blades, down rod, modular regulator, and all accessories including connecting up with 0.75 Sq.mm. size 3 core PVC insulated flexible cable with multi-stranded copper conductor from ceiling rose to connector complete all as specified and directed
Supply and fixing exhaust fan 300mm sweep, heavy duty metalic body, Industrial, heavy duty, 1440 RPM suitable for working on 230 V, 50 HZ, AC supply complete with louvers, fixed with suitable size GI bolts, nuts and washers including connecting up with 0.75 Sq.mm. size 3 core PVC insulated flexible cable with multi-stranded copper conductor from ceiling rose to connector of exhaust fan including making hole in brick wall of suitable size and making good disturbed surfaces as per existing complete all as specified.
Supply and fix in repairs MS arms bracket 30 degree bend, 1.5mtr long for mounting one No street light fitting including clamps / nut / bolts & washer to brace the same properly duly painted in synthetic enamel paint of two coat in silver colour complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete suitable for one single pole MCB 20A complete all as specified .
M&L for sub-main wiring with 2 runs of 2.5 Sqmm PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990, drawn through and including rigid non-metallic medium grade ISI marked PVC concealed conduit with accessories such as Bends, Tees, Elbows,coupler etc including one run of 2.5 Sqmm dia PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990 as earth dolly/mains connected with thimble from main DB to sub main DB including taking down existing submain wiring and making good distrubed surfaces as per existing complete all as specified and directed. Note: (i) 03 Runs x 2.5 Sqmm copper cable for phase, neutral & earth and 01 run of PVC conduit shall be measured as 01 RM. ii) In column/beam/ceiling portion surface wiring shall be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iii) The work shall be carried out conforming to IS-732:1989. iv) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. v) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
M&L for sub-main wiring with 2 runs of 4 Sqmm PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990, drawn through and including rigid non-metallic medium grade ISI marked PVC concealed conduit with accessories such as Bends, Tees, Elbows,coupler etc including one run of 4 Sqmm dia PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990 as earth dolly/mains connected with thimble from main DB to sub main DB including taking down existing submain wiring and making good distrubed surfaces as per existing complete all as specified and directed. Note: (i) 03 Runs x 4 Sqmm copper cable for phase, neutral & earth and 01 run of PVC conduit shall be measured as 01 RM. ii) In column/beam/ceiling portion surface wiring shall be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iii) The work shall be carried out conforming to IS-732:1989. iv) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. v) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
M&L for sub-main wiring with 2 runs of 6 Sqmm PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990, drawn through and including rigid non-metallic medium grade ISI marked PVC concealed conduit with accessories such as Bends, Tees, Elbows,coupler etc including one run of 6 Sqmm dia PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990 as earth dolly/mains connected with thimble from main DB to sub main DB including taking down existing submain wiring and making good distrubed surfaces as per existing complete all as specified and directed. Note: (i) 03 Runs x 6 Sqmm copper cable for phase, neutral & earth and 01 run of PVC conduit shall be measured as 01 RM. ii) In column/beam/ceiling portion surface wiring shall be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iii) The work shall be carried out conforming to IS-732:1989. iv) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. v) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
Supply and fixing in repair sheet metal enclosure VTPN 12 Way, 415 Volts with 250 Amps copper busbar, double door type IP-43, IK-09 protection suitable for housing MCCB upto 160 Amp 3 pole including required numbers of suitable size of copper gland complete etc all as specified and directed by Engineer-in-Charge. Note : DBs shall be conceeled in wall where ever posible including making good the surface to match with surrounding.
Supply and fixing in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar, IP 54, IK 09 suitable for flush mounting and surface mounting complete all as specified and directed.
Supply and fixing in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar, IP 54, IK 09 suitable for flush mounting and surface mounting complete all as specified .
Supply and fixing in repair MCCB 3P 100 Amps,16KA,thermal magnetic,415volts complete all as specified and directed.
Supply and fixing in repair MCCB 3P 160 Amps,25 KA, thermal magnetic,415volts complete all as specified and directed.
Supply and fixing MCCB 4P 63 Amps,25 KA, thermal magnetic,415volts complete all as specified and directed.
Supply and fixing ELCB, 3 pole,63A, 100 Ma for main power supply complete all as specified and directed.
Supply and fixing ELCB, single pole,16A, 50 Ma for main power supply complete all as specified and directed.
Supply and fixing in repair MCB SPN 40 A to 63 Amps,10KA , 'C' curve.
Supply and fixing in repair MCB SP 6-32 Amps,10KA, 'C' curve.
Supply and fixing in repair MCB SP 40 Amps,10KA, 'C' curve.
Material & labour in repair 4mm dia galvanised iron Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing as required complete all as specified and directed by Engr-in-Charge.
M&L in repair JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set incl Supply of Eco Friendly weather proof High Density Polyethylene Earth Pit Chamber. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
M&L in repair 25mm x 4mm GI earth continuity conductor or main earthing lead fixed to wall or buried in ground or drawn in conduit/ pipe or fixed to panel board/motor body/any other equipment complete all as specified
Supply, laying,connecting & testing XLPE insulated, armoured heavy duty 1100 volts grade,35 sqmm 3½ core aluminum conductor cable laid in trenches / pipes / fixed on wall with suitable size GI clamps including taking out old cable complete all as specified and directed.
Supply, laying,connecting & testing XLPE insulated, armoured heavy duty 1100 volts grade, 50 sqmm 3½ core aluminum conductor cable laid in trenches / pipes / fixed on wall with suitable size GI clamps including taking out old cable complete all as specified and directed.
M&L for taking down carefully existing Split AC/Window unit from existing postion & refixing at same position/location including providing additional accerssories as required, brazing of existing copper pipe , gas filling, leak testing, testing & commisssioning complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair copper tubings of appropriate dia for suction line & for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through wall and making good distrubed surface as per existing
Supply and fixing rigid non-metallic PVC conduit 20mm dia including all accessories i.e tees,bends,elbows, reducers, mouth tube ends and fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc on outer surface of building walls/roofs including necessary scaffolding and safety arrangement complete all as specified and as directed.
Supply and fixing rigid non-metallic PVC conduit 40mm dia including all accessories i.e tees,bends,elbows, reducers, mouth tube ends and fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc on outer surface of building walls/roofs including necessary scaffolding and safety arrangement complete all as specified and as directed.
Supply and fixing DLP U-PVC trunking system of size 80mm x 50mm including all accessories such as bodies, flexible cover, partitions, joints, angles and caps, junctions, VDI accessories, supports for mounting wiring accessories etc complete all as specified and directed.
Supply and fixing DLP U-PVC trunking system of size 150mm x 50mm including all accessories such as bodies, flexible cover, partitions, joints, angles and caps, junctions, VDI accessories, supports for mounting wiring accessories etc complete all as specified and directed.
Supply and fixing in repair GI cable tray perforated type 2 mm thick of size 250mm x 50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking fixed on any wall (brick/stone) vertically/horizontally complete all as directed
Supply and fixing in repair GI cable tray perforated type 2 mm thick of size 450mm x 50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking fixed on any wall (brick/stone) vertically/horizontally complete all as directed
Supply and fixing in repair GI cable tray perforated type 2 mm thick of size 600mm x 50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking fixed on any wall (brick/stone) vertically/horizontally complete all as directed
Supply, install, testing and comminssioning of indoor type, floor mounted,double door, factory fabricated,CPRI approved LT panel board of suitable size made out of 3.15 mm thick CRCA sheet mounted on MS angle 45mm x 45mm x 6mm thick , well ventilated, dust and vermin proof, cubical type with individual compartments for enclosures, with necessary arrangement for top entry of incoming and outgoing cables suitable for operation on 3 phase 50 Hz, 415 Volts and panel board should be front opening including locking arrangement complete including internal wiring with 1100 volts grade single core PVC insulated copper conductor FRLSH cables of suitable current carrying capacity and making good all connection of incoming and outgoing cables by using suitable size copper lugs including 600 Amps rated aluminium bus bar for phases and 300 Amps rated aluminium bus bar for neutral with RYB & N PVC sleeves wrapped on it duly powder coated of approved colour mounted on PCC 1:2:4 type B1 foundation of approved size including dismantling existing LT panel board after disconnecting all connections carefully and making good disturbed surfaces as per existing complete all as specified and with following accessories a) MCCB 400Amps 4pole,36 KA,Thermal magnetic - 2 Nos (Incoming ) (Power supply from two sides). b) MCCB, 100Amps,3 pole ,16KA,Thermal magnetic- 2 Nos (Out going) c) MCCB, 200Amps,3 pole, 25KA,Thermal magnetic- 2 Nos (Out going) d) Manual changer over 400 Amp , 415 Volt AC , 4 Pole & Size F2 - 01 No e) Digital type Volt meter 0 - 500V - 1 No. f) Digital type Ammeter with CT's - 1 No. g) Indication lamps (R,Y,B) LED type - 1 set
SCHEDULE 'A' PART III (FIRE FIGHTING) Supply & fixing in repair fire alarm control panel complying with BS EN 54- 2 loop with 99 detectors & 99 Modules & upto 200 detectors (per each loop) complete all as specified and directed.
Dismantaling and taking down carefully fire detector, manual call point, response indicator and sounder from its position and refixing after working on ceiling, wall at its own position complete all as specified and directed.
Supply & fixing in repair detectors complying with and type certified to EN -45 Addrssable type multi senser detector with heat and smoke detector with self built intelligence as per IS:11360 complete all as specified and directed.
Supply & fixing in repair addressable manual call point resettable type complete all as specified and directed.
Supply & fixing in repair addressable electronic sounder cum strobe complete all as specified and directed.
Supply & fixing in repair remote response indicators all as specified and directed by Engr-in-Charge.
Supply & laying in repair PVC armoured control cable 1.5sq mm copper conductor 2 core, FRLS 1100 volts, for fire alarm system drawn through and including heavy duty PVC conduit of suitable suitable size fixed on wall/celling complete all as specified and directed.
Supply and fixing in repairs junction box of size not less than 100mm x 100mm with connector encloser, 3 terminal/PVC/polycarbonate, isolated body complete all as specified.
Supply and fixing in repair short circuit isolators complete all as specified and directed.
Supply and fixing in repairs addressable control module complete all as specified and directed.
SCHEDULE 'A' PART IV (LIFT) Dismantling of lift of any capacty with all controller, main rope, car cabin, car door, landing door LOP, COP with motor and gear and governor rope and ARD from existing position and making good disturbed surfaces as per existing complete all as specified and directed by Engr-in-Charge.
Design, supply, install, testing and commissioning 08 Passanger lift to serve G+05 upper floor with AC variable voltage and variable Frequency (VVVF Drive) complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/ without attendant, automatic centre opening door with VVVF door drive (electric motor driven mechanism) sliding stainless steel door, automatic rescue device (ARD) system, infra red sensor in full height of door as specified below :-
Type of Lift : 08 Passanger Lift
Load Capacity : 544 Kg
Speed :1.5 Meter Per Sec with single speed motor
Power Supply : 415 volts, 3 phase AC, 50 Hz
Type of Drive : CA variable voltage & variable Frequency drive
Type of Machine : Gearless & directly coupled Horizontal traction machine
Car Size (Inside) : 1300 mm wide x 1100 mm deep x 2200 mm ht
Car Door : Automatic telescopic opening with VVVF drive controlled opening size 800 mm wide x 2000 mm height sliding type fabricated by SS sheet not less than 1.2 mm thick having hairline finish N-304
Landing Door at all floor : Automatic center opening with opening size 800 mm wide x 2000 mm height sliding type fabricated by SS sheet not less than 1.2 mm thick having hairline finish N-304
Car enclosure : Standard manufacturing with MS frame & stainless steel in hairline finish, having stainless steel false ceiling with hairline finish, internal lighting with LED light fitting complete, internal ventilation system provided with concealed Arial flow/ cross flow fan with auto cut of system and grill/wire mesh for protection
Terminal buffer : Metal special spring buffer
Door opening (Inside): clear opening size 700 mm wide x 2000 mm height
Car & CWT guide : Machined guide for car 82 mm x 68 mm x 09 mm and for CWT 50mm x 50 mm x 05 mm
Flooring : Wooden tiles
Signals : Combined luminous hall button with LED hall position indicator at all floor. LED for car position indicator to be fitted in COP made of stainless steel.One Nos car operating panel with Luminous button in car of stainless steel.Car direction indicator in car & Landing. Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. Overload warning feature in car cabin (display and announcing type both). All signal fixture & car operating panel on stainless steel plate with hair line finish.
Safety Devices :Infra and sensor safety edge of door for entire height. Automatic rescue device (ARD)/ automatic landing device to be operating with maintenance free batteries for landing. Built in announcing system without hand set 02 Nos (One each in car & near ground floor landing door & one announcing system, press & speak type 3 way. The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. Stainless steel hand rail 32 mm dia inside the car cabin.
Stops and opening : 06-06, G+1+2+3+4+5 (Front side at Ground & opposite side opening on first & second side)
Control operation : simplex full collective, automatic operation with/ without attendant
Hoist way construction : MS fabricated structure covered with aluminum bonded sheet clear inside 1700 mm wide x 1500 mm deep
Machine room : Located above the hoist way (Machine Room Less)
AC VVVF drive : Integrated controller shall be enclosed loop type
Door drive : AC-VVVF controlled close loop operated, PM motor
Counter weight : Cast iron or MS profile cut
Notes : (i) Design and diagram of lift with all dimension to be submitted for approval of accepting officer through GE prior to installation. (ii) Cost of testing and commissioning from lift inspector & obtaining licence from Govt of Maharashtra shall deemed to be included in the quoted rate. (ii) The penalty of Rs 2000 per day per lift shall be recovered for non operation of lifts in case of non rectification of defects within 24 hrs of intimation.
RS Enterprises (BID ID -3345750)
the bhimani group of companies (BID ID -3344615)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tenderdocument.rar
Tender Documents • 3.51 MB
BOQ.xls
BOQ • 8.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .