| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 LAccepted-Finance | ₹3.0 L | 1 | Accepted-Finance Single bid |
Tender Value
₹3.0 L
EMD Value
₹5,933
Closing Date
20 Feb 2026, 10:00 amClosed
Executive Engineer, Store Division, APWD, Sri Vija
Executive Engineer, Store Division, APWD, Sri Vijaya Puram
A R and M O 28 Nos. Split Type Air Conditioners Installed at Andaman Bhawan Anna Nagar, Chennai during 2025-26 2nd Call.
2026_APWD_21921_1
e-Tender/DB/SD/2025-26/1228 dt 13/02/2026
Open Tender
Electrical Works
365 days
Executive Engineer, Store Division, APWD, Store Di
4 documents required · 4 mandatory
₹0
₹5,933
Yes
26 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
13 Feb 2026 - 19 Feb 2026
Labour
Air Conditioner Mechanic
Khalasi
Supplying installation, testing and commissioning of condenser unit complete with necessary gas charging and servicing the unit as required for split type A/C 1.5 ton capacity.
Supplying installation, testing and commissioning of condenser unit complete with necessary gas charging and servicing the unit as required for split type A/C 2.0 ton capacity
Pressure testing for leakage flushing vaccummission the system, gas charging with Freon - R 22/R410A Servicing the unit testing for satisfactory performance, replacement of necessary spare aprts i/c re-installation of the unit etc as required for AC (1.5 Ton)
Pressure testing for leakage flushing vaccummission the system, gas charging with Freon - R 22/R410A Servicing the unit testing for satisfactory performance, replacement of necessary spare aprts i/c re-installation of the unit etc as required for AC (2.0 Ton)
Replacement of defective compressor unit with new one suitable for 1.5 Ton capacity room AC i/c pressure testing for leakage flushing vaccummission the system, gas charging with freon-22/R410A servicing the unit painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc. as required.
Replacement of defective compressor unit with new one suitable for 2.0 Ton capacity room AC i/c pressure testing for leakage flushing vaccummission the system, gas charging with freon-22/R410A servicing the unit painting and testing for satisfactory performance, replacement of necessary spare parts i/c reinstallation of the unit duly tested etc. as required.
Supplying of PCB Assembly Split AC Common-Artic/Universal Board by new one for 1.5 Ton Capacity.
Supplying of 50 Mfd Capacitor for AC
Supplying of 60 Mfd Capacitor for AC
Supplying of 3.15 Mfd Capacitor for AC
Supplying of 4.0 Mfd Capacitor for AC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TenderDocument.pdf
Tender Documents • 1.46 MB
BOQ_23199.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid