Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.3 LAccepted-AOC GROUND FLOOR SHIVSHANKAR NAGAR WADALA TOOK TERMINAL ROAD S P ROAD WADALA WEST MUMBAI 400 037 | MUMBAI | MUMBAI | MAHARASHTRA | 400037 | ₹81.3 L Quoted ₹82.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹85.4 LRejected-AOC 16 GAYKE NAGAR NEAR GANESH MANGAL KARYALAYA HIRAPUR ROAD CHALISGAON JALGAON 424101 | JALGAON | MAHARASHTRA | 424101 | ₹85.4 L | L2 | Rejected-AOC L2 |
| 3 | L3₹85.9 LRejected-AOC | ₹85.9 L | L3 | Rejected-AOC L3 |
| 4 | L4₹88.2 LRejected-AOC | ₹88.2 L | L4 | Rejected-AOC L4 |
| 5 | L5₹90.0 LRejected-AOC S NO 46 KONDHAVA PUNE 48 PUNE MAHARASHTRA INDIA 411048 | PUNE | MAHARASHTRA | 411048 | ₹90.0 L | L5 | Rejected-AOC L5 |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
11 Apr 2026, 3:00 pmClosed
Registrar, SPPU
Registrar Office, SPPU
Please refer Tender documents.
2026_UOFP_1289227_1
C.A.No.2025-26/SPPU/ ESTATE/EE/ CIVIL/24
Open Tender
Civil Works
Percentage
180 days
campus of SPPU
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
₹1.1 L
3 Aug 2026
24 Mar 2026
13 Apr 2026
24 Mar 2026
11 Apr 2026
24 Mar 2026
24 Mar 2026 - 11 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing & laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black in colour Spec. No: - As directed by Engineer in charge | |||||
| - | Providing & Applying fibre reinforced elastomeric liquid water proofing treatment for terrace by using asian paint smartcare damp proof suprema including surface cleaning, Crack filling, applying 3 coats of paint in 3 equal interval of 5-6 hour for drying after application of each coat etc. completed, Spec.No: - As directed by Engineer in charge | - | Sqm | - | - |
| - | Providing and applying priming coat over new wood and wood based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting, scaffolding etc. complete. SP No. As directed by Engineer-in-charge | - | Sqm. | - | - |
| - | Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. SP No. As directed by Engineer-in-charge | - | Sqm. | - | - |
| - | Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) SP No.Bd. 0.5 page No. 405 | - | Sqm. | - | - |
| - | Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Spec No.As directed by Engineer in charge. | - | Sqm. | - | - |
| - | Providing and filling crack filling material to cosealed existing crack at any location by Dr. Fixit crack filler as per specification stipulated by manufactures & As directed by Engineer-in-charge etc.complete.(Need prior approval of Engineer incharge before execution of this item ) SP No. As directed by Engineer-in-charge | - | Rmt. | - | - |
| - | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 | - | Sqm. | - | - |
| - | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc.complete. | - | Sqm. | - | - |
| - | Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks,including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. | - | Rmt | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_2216490.xls
BOQ • 0.32 MB
tender_waterproofing_girl_gentsfinal.pdf
Tender Documents • 3.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].