| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.4 L+₹2.4 L (5.52%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹46.7 L+₹2.8 L (6.33%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹47.9 L+₹4.0 L (9.04%)Rejected-Finance SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹47.9 L+₹4.0 L (9.04%)Rejected-Finance OPPOSITE GATE NO 2 NORTH BENGAL UNIVERSITY PO N B U DIST DARJEELING WB | DARJEELING | DARJEELING | WEST BENGAL | 734013 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Jul 2021, 6:00 pmClosed
GE Bengdubi
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
MAINTENANCE/REPAIR/ REPLACEMENT/IMPROVEMENT OF STREET LIGHT JUNCTION BOX/CONTROL PANEL TIMER RENEWAL OF EARTHING WITH ALLIED ACCESSORIES WORKS CEILING/EXHAUST/ WALL MOUNTED FAN AT MD AND OTM ACCN UNDER AGE E/M OF GE BENGDUBI MIL STN
2021_MES_451670_1
GE/BENG/15 OF 2021-22
Open Tender
Electrical and Maintenance Works
Works
180 days
Bengdubi
MES Enlisted/ Un-enlisted contractor of Class D and above with category b(i)
8 documents required · 8 mandatory
₹500
GE Bengdubi
₹90,000
Yes
26 Jul 2021
16 Jun 2021
7 Jul 2021
16 Jun 2021
5 Jul 2021
30 Jun 2021
18 Jun 2021 - 23 Jun 2021
Amount
SCHEDULE 'A'
Excavation in trenches not exceeding 1.50 m wide and 1.5 mtr depth for foundation etc, not exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Ditto all as per item no 1.00 here-in-before but depth exceeding 1.5 m and not exceeding 3 m.
Returning filling in approved earth, including spreading leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and directed.
S&F in repair of GI Pipe 50 mm light grade including fittings to poles/laid under road through boring for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and directed.
Supply & Laying Sub-Class old size 'B' Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.
Taking down carefully existing unserviceable any type of street light/flood light fitting of any watt from existing location to carry out the necessary repair / replace and fixed to existing GI pipe bracket on pole including necessary electric connections complete all as specified and directed.
Supply and fixing in repair/replacement of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with toughened glass with IP66 protection street light with high power LEDs as light source connecting and testing LED street lights of 90 watts capacity including 10 KV SPD complete all as specified and directed. Make : Havells cat part No ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent Crompton/Philips)
Ditto all as per item No. 9.00 above but of 60 W capacity LED Street light Make: Havells cat part No ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent Crompton/Philips)
Ditto all as per item No. 9.00 above but of 45 W capacity LED Street light Make :Havells cat part No ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent Crompton/Philips)
Ditto all as per item No. 9.00 above but of 36/35 W capacity LED Street light Make : Havells cat part No ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or equivalent Crompton/Philips)
Supply and fixing in repair/replacement of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with toughened glass with IP66 protection flood light with high power LEDs as light source connecting and testing LED flood lights of 200 watts capacity including 10 KV SPD complete all as specified and directed. Make : Havells cat part No JETAVALOURFL200WLED757PINTNBLTG or equivalent Crompton/Philips)
Ditto all as per item No. 13.00 above but of 120 W capacity LED Flood light Make : Havells cat part No JETAIRISFLS120WLED757APNBLTG or equivalent Crompton/Philips)
Ditto all as per item No. 13.00 above but of 50 W capacity LED Flood light Make : Havells cat part No JETAQUANTOPLUSFLP50WLED757SYMLENS or equivalent Crompton/Philips)
Taking out old U/S underground LT cable of any size, any position from trenches, floors and walls, all as specified and directed.
Supply, fixing,Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of 6 Sqmm, 2 Core all as specified and directed. (Make: Gloster/Finolex/Polycab)
Ditto all as per item No. 17.00 above but for size of cable 10 sqmm, 2 core
Ditto all as per item No. 17.00 above but for size of cable 16 sqmm, 4 core
Ditto all as per item No. 17.00 above but for size of cable 25 sqmm, 3.5 core
M&L for 3 core cable 1.5 sqmm of FRLSH PVC insulated copper conductor weather proof in existing surface/ recessed/on pole with PVC conduit pipe, clamps as required complete all as specified and directed. Make : Finolex/Polycab/Plaza
S&F street light bracket made out of GI tubing medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete of size 32 mm including taking down old bracket. Make: Tata/Bansal/Jindal
Ditto all as per items No 22.00 above but 25 mm bore pipe
Cutting and trimming of tree branches, bushes n.exc 5 Mtr girth all along LT overhead lines/guard wire and removing branches out of defence land complete all as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part-I complete all as specified and directed.
Material and labour for preparation of old rusted steel surface of LT steel tubular swaged pole (of any length upto 9 mtr) and applying one coat of black synthetic enamel paint upto 1.2 mtr height as per the existing pattern above the PCC coping and one coat of aluminium paint beyond 1.2 mtr height (for the rest portion) including cross arms brackets and re-writing pole numbers and and cutting vegetation growth all around and on height poles upto 1 mtr on the pole upto 1 mtr radius complete including replacement of self adhesive fluorescent colour tape as per existing pattern and size all as specified and directed.
Material and labour for preparation of surfaces by scrapping of PCC poles of any length and applying two coats of weather coat paint black in colour upto 1.2 mtr heigth as per the existing pattern above the PCC coping and applying two coats of weather coat paint crimson colour includng applying alluminium paint to cross arms brackets and re-writing pole numbers and cutting vegetation growth all around and on eht poles upto 1 mtr radius complete including replacement of self adhesive florescent copor tape as per existing pattern and size all as specified and directed.
M&L for preparation of old rusted steel surface or feeder pillar box /LT panel of any size , applying one coat of synthetic enamel paint as per the existing pattern above the PCC and black paint on legs of feeder pillar/LT panel and re-writing panel number or location and cutting vegetation growth all around and on the feeder pillar box/panel board upto 1 mtr radius complete all as specified and directed.
Supply and fixing of MCCB 125 amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA, and 100 % Icu including spreader terminals and connected acessories complete as specified and directed.Make: Legrand/ L&T/ABB
Supply and fixing of MCCB 100 amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA and 100 % Icu including spreader terminals and connected acessories complete as specified and directed.Make: Legrand/ L&T/ABB
Supply and fixing of MCCB 63 amps, 4 pole,415 Volt adjustable type with breaking capacity 16 KA and 100 % Icu including spreader terminals and connected acessories complete as specified and directed.Make: Legrand/ L&T/ABB
Supply and fixing of MCCB 63 amps, 4 pole,415 Volt adjustable type with breaking capacity 10 KA and 100 % Icu including spreader terminals and connected acessories complete as specified and directed.Make: Legrand/ L&T/ABB
Dismantling of old unserviceable bending/broken pole of any type and any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation and earth work as required and removing the same from site and including earth work complete all as specified and as directed.
Supply and errection of steel tubular swaged poles 9.0 metre long, type 410 SP-31 complete with cast iron base plate, final taper plug, bolts, nuts and screws, pole cap etc confirming to IS-2713 of 1980 including painting two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces and numbering to be done in black synthetic enamel paint complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 with using 40 mm grade crushed stone aggregate cement concrete in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 with using 20 mm grade crushed stone aggregate as in copping of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
Taking down the existing sheet metal loopin loopout and S & F junction box made of thermoplastic/FRP of size 230mm x 170mm x 105mm consisting of 4 Nos aluminium busbar of size 150mm x 20mm x 2mm thick fixed on porceline support inside enclosure with MCB SP 6 Amps and using 40 x 6mm size MS clamps of required shape & size with bolts, nuts & washers and making connection by providing suitable size of lugs / binding and testing directed complete all as specified and directed. Make : Syntex/Hensel or equivalent
Labour only for finding fault in ACSR Conductor including jumpper in street light feeder and remove the carbon in jumper or Street light service wire complete all as specified and directed.
M&L for lowering of high mast carriage carefully from 20 mtr high structure for repairing light luminaries and raising latern carriage after repairing the light luminarises and adjust to its proper postion serving to winch mechanism pulleys steel wire ropes end terminal of SWR and greasing drain gearbox oil and toping up complete all as specified and directed.
S&F in repair analog timer switch, surface mounting as per sample for automatic operation of street light complete all as specified and directed.
S&F in repair Digital timer switch, surface mounting as per sample for automatic operation of street light complete all as specified and directed.
S&F in repair contactor modular type with ON/OFF indicator and label holder 4 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
S&F in repair contactor modular type with ON/OFF indicator and label holder 3 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
M&L for repair of existing PCC coping of all type of pole/panels etc, cracked, damaged PCC coping repair with PCC 1:2:4 (type B1) by using 20mm stone aggregate incl plastering and making good surface with two coat of white wash etc complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire one twin core cable flat or circular all complete including taking out unserviceable one of size 4 sqmm. Make: Plaza/Finolex/RR Cable
Ditto all as per item No. 45.00 above but 6 Sqmm
Ditto all as per item No. 45 above but 10 Sqmm
M&L for Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed.
S&F stay assembly (ISI Marked) complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Part I with using stay rod of 20mm dia including dismantling unserviceable stay assembly complete all as specified and directed. (excavation and earth work shall be measured and paid seperately under relevant items of Sch 'A'/ BoQ)
Stretching / restringing only ACSR conductor in position on LT over head lines of any size, type, span length with permisiable span sag and binding with pin/shackle insulator with new aluminum binding wire not less than 2mm dia complete all as specified and directed.specified and directed.
S&F in repair/replacement of pin type insulator porcelain vitreous, white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washer and one galvanized iron nut 100mm height 6.5mm dia for 1100 volts grade complete all directed. Make: Jaipuria/Pactil/BHEL.
S&F in repair/replacement of shackle type porcelain vitreous white, brown or green insulator of size 75mm height, 90mm dia (maximum) including mild steel straps of section 31mmx3mm, washers, 12mm dia insulator bolt and nut suitable for working pressure 1100 volts grade complete all as specified and directed. Make: Jaipuria/BHEL/Pactil
S&F in repair/replacement of loop type insulator vitreous porcelain white, brown or green large size with overall dimensions 90 x 140mm and clearance of hole 25.5 mm complete all as specified and directed. Make: Jaipuria/BHEL/Pactil
Dismantling of LT over head ACSR conductor of any size including separating, serviceable conductor and kept in safe custody for re-use in the work and removing unserviceable conductor for site complete all as specified and directed.
S&F aluminum conductor steel reinforced (ACSR) on over head LT electric line with stretching and tensioning the same with required span sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2mm dia complete all as specified and directed. Make: Alind/Bharat/ISI Marked.
Supply and fixing of automatic street lightswitch using infrared sensor based nature switch forautomatic switching of street lightnature switch operation should be based on natural light luxlevel required illuminance level for switching on is ,30 lux and for switching off.10 lux. The sensor should also have part night operation facitlity ofmin 4 hrs to max 12 hrs. The sensor alongwith suitable power contractor incoming outgoing MCB SP and automanual (sensor bypass se43lection option should be enclosed in av pole/wall mountable enclosure made of rust proof electric shock proof, terrmite proof and FR gradeSMCbox conforming to IP 54 three phase load of 8 KW with circuit wiring min 10 Sqmm 3 nos contactor each of 20-25amps incoming outgoing MCB (3Nos) rating 20-25 amps all as directed.
Takinf down and checking of ceiling fan / exhaust fan / wall any type and size at site on daily basis after disconnecting the electrical connection including replacement of unserviceable spares parts with new parts, lubricating with approved grade of grease and necessary minor work (if required) and refixing the fan in same position including all electrical connection all as directed. ii) New spare parts shall be measured and paid separately as ‘ Supply only’ under respective items of Sch 'A' / BoQ. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and material and labour for replacement of two nos split pins, one connection block and one rubber reel all as specified and as directed. Note : i) Rewinding work of armature (if any) shall be measured and paid separately ii) New spare parts required for replacing old burn out parts other than connector, split pins, connection block and rubber reel shall be measured and paid separately under respective items of Sch 'A' / BoQ. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Ditto all as pr item No.59.00 here-in-before but for 1400mm sweep ceiling fan all as specified and as directed.
Taking down carefully existing exhaust fan of any size sweep and any make after disconnecting the electrical connection, and removing the exhaust fan with blade to the work shop including cleaning of dust and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) re-assembling the fan complete , testing and refixing the fan in same position including all electrical connection and material and labour for replacement of one connection block all as specified and as directed. Note : i) Rewinding work (if any) shall be measured and paid separately ii) New spare parts required for replacing old worn out parts other than connector, shall be measured and paid separately under respective items of Sch 'A' / BoQ. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for upto 300 mm sweep exhust fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Ditto all as pr item No.62.00 here-in-before but for 450 mm sweep ceiling fan all as specified and as directed.
Material and labour for painting of ceiling fans complete of any sweep/make with one coat of first quality synthetic enamell paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavaties with filler materials,and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm ) complete all as specified and as directed.
Ditto all as pr item No.64.00 here-in-before but for painting to exhaust fans with blade complete of any sweep/make all as specified and as directed.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan (Make - TATA / SKF/ NBC ).
Supply only bearing No.6203/6204 for ceiling/ Exhaust fan (Make - TATA / SKF/ NBC ).
Supply only fan condensor 3.15 mfd oil filled (Make - USHA / UNIVERSAL / Havells}.
Supply only fan condensor 3.15 mfd dry type (Make - USHA / UNIVERSAL /Havells}.
Supply only fan condensor 2.5 mfd oil filled (Make - USHA / UNIVERSAL / Havells).
Supply only fan condensor 2.5 mfd dry type (Make - USHA / UNIVERSAL / Havells).
S&F in replacement electronic fan regulator socket type (step 0-5) (Make - ANCHOR / HAVELLS / CROMPTON).
S&F in replacement electronic fan regulator switch type (step 0-5) (Make - ANCHOR / HAVELLS / CROMPTON).
S&F in replacement modular regulator step type 120 watt, 2 module complete all as specified and directed.
Supply only gun metal bush of any size (Make - TATA/MSP).
Supply only mounting clamp assembly complete for ceiling fan 1200mm/1400mm sweep with amp,bolt,nut,washers, safety/ split pins and rubber bush and all as specified and directed.
Supply only down rod assembly complete for any type of ceiling fan all as specified and directed.
Supply and fixing in replacement louvers shutters aluminium based for Exhaust fan of any size up to 300 mm sweep suitable for any make and bolt, nut, washers etc complete including taking down old unserviceable one all as directed.
Supply and fixing in replacement louvers shutters aluminium based for Exhaust fan of any size above 300mm up to 450 mm sweep suitable for any make and bolt, nut, washers etc complete including taking down old unserviceable one all as directed.
Taking down carefully wall fan of any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection. Note : i) Rewinding work (if any) shall be measured and paid separately ii) New spare parts required for replacing old worn out parts shall be measured and paid separately under respective items of Sch 'A' / BoQ. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for wall fan of any size with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Material and labour for flexible multi stranded copper wire twin twisted two core of size 0.75 sqmm all as specified and as directed.(Make:Havells/Plaza/Polycab)
S&F aluminium based fan blade (set of three Nos) suitable for any type and any size with nut bolts complete all as directed.
Supply only ceiling fan as per existing size (02 Nos ) complete all as directed.
S&F MS type hook suitable for any type and size of ceiling fan complete all as directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 53,968.00 (refer Tender Srl Page No 39). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
KD SAHA and CO.INDIA
M/S R. K. INDUSTRIES
M/S G D CONSTRUCTION
M/S Vaishno Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .