TENDER ELG
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(In this connection scanned copy of Annexure VIB duly filled up must be attached with offer).
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender .Other terms and conditions shall follow of GCC, April 2022. Definition of Similar nature of work has given below (1.1)
Defination of Similar Work :- As per CEE's letter No. EL/112/0, dated 16.09.2025 Item Sl. No. 8 ( i ) under "Lifts and Escalators "Supply, Installation , Testing and Commissioning of Lift/Escalator with or without AMC/CAMC AND Item Sl. No.2.(ii) under "LT Electrical Works" Execution of any HT or LT Electrical work.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
17 conditions · 7 needing a document upload
The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Submission of Documents in support of Eligibility Criteria : All documents in support of fulfillment of eligibility criteria with respect to completion of 'Similar Nature of work for technical Eligibility criteria 'and 'Total Contract value for Financial Eligibility Criteria' should be uploaded online in the website with scanned copy at the time of tender bidding with the details. No post - tender communication , in any form will be made or entertained , after opening of tenders in this regard .Railways may however call for the originals of the credentials for verification or an clarifications/Confirmations on the contents of the documents submitted .Eligibility of tenderers shall be decided solely on the basis of the documents submitted along with the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance on any account.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Provision of passenger lifts at HWH, DKAE, TAK & SNT over Howrah Division.
EL-HWH-25-21-3625-R
EL-HWH-25-21-3625-R
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹4.8 L
10 Aug 2026
17 Jul 2026
27 Jul 2026
71 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,41,49,612 | ||
| — | — | — | Above/ 13628079.00 Below/P | ||
| Design, manufacture and supply of Machine Room / Machine Room Less ( MRL ) (As per site condition), Gearless type operation Passenger Lift ( G + 1 ), 2 Stops, 2 Openings ( opposite / same side opening as per site requirement ), 14 Passenger capacity ( 952 Kgs ) with following features :- Load & Speed - about 952 Kgs @ 1M/Sec complete with Variable Voltage Variable Frequency (VVVF) drive, Automatic Rescue Device ( ARD ) with battery backup, Electromagnetic type Breaking arrangement with brake liners and DC Voltage energization and spring tension closing, Driving Motor : PMSM (Permanent Magnet Synchronous Motor), Driving Ropes : Ropes with factor of safety 12 or above, Electrical Safety - 3 phase limit switch to protect against over travel, Single phasing preventer with a protection against phase sequence reversal, Full proof gate locks for landing doors, Car gate switch, Over speed Governor, Over speed safety device. Lift car comprises with SS Cabin hair line finish Car enclosure and centre opening hair line finish door, also furnished with UPS based Lithium-Ion Battery operated Emergency Light, LED Lights, Car ventilation automatic ON/OFF Fan, Alarm, Digital floor Indication, Push Button for each floor, On/Off switch, Fan switch, IP based CCTV camera inside lift car along with web based and mobile application for monitoring the footage alongwith all type data transferring facility to IR-Niyantrac platform via RS-485 port including all other associated accessories complying RDSO specification No. RDSO/2013/EM/SPEC/0016 (Rev '2') -2025 dated 25.09.2025 or latest complete with installation, testing and commissioning of above Lift including related civil work and scaffolding. | — | 9.00 | — | — | |
| — | — | — | Above/ 163800.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) along with refilling the trench and make good of surface as its original condition ( Cable will be supplied by Railway ) | — | 700.00 | — | — | |
| — | — | — | Above/ 45600.00 Below/P | ||
| Trenching and laying of cable under ground by soil cutting through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 300.00 | — | — | |
| — | — | — | Above/ 32000.00 Below/P | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 800.00 | — | — | |
| — | — | — | Above/ 15300.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 180.00 | — | — | |
| — | — | — | Above/ 74160.00 Below/P | ||
| Trenching, laying under road / track through 50 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) | — | 360.00 | — | — | |
| — | — | — | Above/ 16435.00 Below/P | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) | — | 19.00 | — | — | |
| — | — | — | Above/ 600000.00 Below/P | ||
| Laying of cable underground through 100 mm diameter HDPE pipe by Micro Tunneling cable laying method including supply and jointing of HDPE pipe (PE-100 grade, PN-10 or higher). ( Cable will be supplied by Railway ) | — | 400.00 | — | — | |
| — | — | — | Above/ 243544.00 Below/P | ||
| Supply of heavy gauge GI fabricated Cable tray with GI supporting structure and GI nut-bolts and washer of suitable sizes as per site requirement including fixing and commissioning. | — | 4.00 | — | — | |
| — | — | — | Above/ 143082.00 Below/P | ||
| Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) | — | 9.00 | — | — | |
| — | — | — | Above/ 1233.00 Below/P | ||
| Fixing, connection, testing and commissioning of above TPN MCB DB including all incoming and outgoing cables glanding, cable connection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. | — | 9.00 | — | — | |
| — | — | — | Above/ 61290.00 Below/P | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 10 way, 50Hz, complete with 6 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 9.00 | — | — | |
| — | — | — | Above/ 1089.00 Below/P | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 9.00 | — | — | |
| — | — | — | Above/ 99200.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 800.00 | — | — | |
| — | — | — | Above/ 188500.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1300.00 | — | — | |
| — | — | — | Above/ 300000.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for three phases and one neutral in GI conduit of 25mm dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 600.00 | — | — | |
| — | — | — | Above/ 10512.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 36.00 | — | — | |
| — | — | — | Above/ 352500.00 Below/P | ||
| Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 470.00 | — | — | |
| — | — | — | Above/ 19080.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of 20-22W LED batten (Type of LED - Surface Mounting Device ) tube with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, extruded aluminium housing and milky polycarbonate diffuser ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), LED luminaire system efficacy - Greater than 120 Lumens per Watt @ 350mA drive current, Colour Temperature - 6500K (Cool white), CRI>80, SDCM<5, Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD<10%, Driver HV Cut off @ 325V/440V (P2P) protection for 8 hrs., Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and indivi- dually BIS approved with 60 months warranty including fixing with GI clamps made of GI flat of suitable size & GI nut-bolts.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 90.00 | — | — | |
| — | — | — | Above/ 30060.00 Below/P | ||
| Designing of mounting layout, Supply, installation, connection and commissioning of Recessed mounting Circular type 12W LED luminaire (for mounting in false ceiling), Color temperature- 3000 K, SMD type LED Chip as per LM 80/IS16106, LED chip Efficacy >/=110 Lm/Watt for 6000 K,( LED make - Nichia, Osram, Seoul, Philips, Lumileds, Avago, Cree ) complete with all accessories, operating voltage and frequency range 140V to 280 V at AC 50 Hz,Driver Efficiency >/=85%, Life span of LED chip -Greater than 50,000 burnings hours as per LM-80 report and minimum 2 years free replacement warranty including fixing with G. I. clamps made of G. I. Flatof suitable size & G. I. Nut, bolts etc.Make : Philips (Signify) /Havells / Bajaj / Panasonic/ Crompton / Jaquar/Lighting Technologies/ Halonix ) | — | 90.00 | — | — | |
| — | — | — | Above/ 31185.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 27.00 | — | — | |
| — | — | — | Above/ 310815.00 Below/P | ||
| Supply of MCCB with Microprocessor Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) All Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication, suitable for Release Range 25-63A, 4 Pole with metal enclosure alongwith Static Multifunction panel mounting Energy Meter suitable for operation on 3 Ph, 415V, 50Hz supply system similar to LK (L&T) model : MFM 4410 LED meter Cl 1 with RS485 - 1 no. or equivalent, CTs of suitable ratio for MFM - 3 nos., LED indication lamps for Phases and "ON & OFF" indication for breaker including fixing, connection, testing and commissioning. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 9.00 | — | — | |
| — | — | — | Above/ 124020.00 Below/P | ||
| Supply of Thermoplastic Polycarbonate Busbar Chamber of dimen- sion 450mm x 300mm x 210mm consisting with 4 nos. tinned copper busbar of each bar of capacity 200 Amp, 6 way, suitable for 415V, 50Hz supply system and 6 nos. Cable glands with Ingress protection : IP65 or higher as per IEC-60529 ( weather proof), rust, dust, moisture and shock proof, anti corrosive, halogen free acid resistant, light weight, impact resistant IK 08/09 as per IEC- 60068-2-72, fire returdant, insulated, UV stabilised as per EN ISO 4892, should withstand glow wire test at 960 degree C as per IS 11000-2-1,IEC-60695-2-10 and fire rated UL94V-0 complete with hinged door with locking arrangement including fixing, connection and commissioning of above Junction Box on pole/structure with mounting clamp. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 9.00 | — | — | |
| — | — | — | Above/ 3108432.00 Below/P | ||
| Supply of LT Wall Mounted/ Floor Mounted Double Door Cubical Outdoor type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder comprising with the following items for 250 KVA to 300 KVA Load :- a) MCCB, 4 Pole, ( 160 - 400 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 2 nos. b) MCCB, 4 Pole, ( 100 - 250 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with features mentioned in (a) - 2 nos. c) MCCB, 4 Pole, ( 40 - 160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release similar to iTRP type of LK (L&T)-make or equivalent with features mentioned in (a) - 2 nos. d) MCCB, 4 Pole, ( 25 - 100 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release similar to iTRP type of LK (L&T)-make or equivalent with features mentioned in (a) - 6 nos. e) MCCB, 4 Pole, 400 Amp, 415V, 50Hz, 36kA, without protechtion release, used as bus coupler isolation - 1 no. f) RCBO, 4 Pole, 32 Amp, 415V, 50Hz, 10kA, "Sensitivities- 300 mA , Suitable for AC + Pulsating " DC (Type A) + Harmonics - 4 nos. g) RCBO, 4 Pole, 63 Amp, 415V, 50Hz, 10kA, "Sensitivities- 300 mA , Suitable for AC + Pulsating " DC (Type A) + Harmonics - 6 nos. h) Tinned Copper Busbar (4 Bar) each of capacity 600 Amps., 415V, 50 Hz. - 1 set. i) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 12 nos. j) CT of suitable ratio for MFM - 36 nos.k) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 64 nos. l) Petty Store for control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays etc. - 1 job. m) Fabrication work for above panel - 1 job. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 4.00 | — | — | |
| — | — | — | Above/ 155424.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 4.00 | — | — | |
| — | — | — | Above/ 444608.00 Below/P | ||
| Supply of cubicle LT panel boards, made of 14 SWG (2mm) MS sheet duly powder coated for APFC Capacitor Bank consisting with the following : a) Super Heavy Duty Capacitor ( MPP ) suitable for 3 Ph, 440V, 50 Hz supply system (25 KVAR x 4 nos.) - 100 KVAR b) Power Factor Controller similar to EPCOS Model No. BR 6000 series or equivalent including CT's - 1 no. c) Capacitor Contactor suitable for operation on 3 Ph, 440V, 50 Hz supply system suitable for 25 KVAR capacitor - 4 nos. d) MCCB, TP, 320-400A, 415V, 50 Hz, 50 kA - 1 no. Complete with CTs, Ammeter, Voltmeter, Selector Switches for ammeter and voltmeter, LED indication lamps for Phases and ON / OFF indication for breaker including fabrication and copper banking ( Make for Capacitor - EPCOS / ABB / Siemens / Keltron / Havells / Alcon / Usha ) ( Make for Power Factor Controller and Contactor etc. - LK (L&T) / Siemens / ABB / Schneider / EPCOS ) ( Make for MCCB etc. - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meters - Secure / LK (L&T) / Genus / Conzerv / Selec / Rishabh / Socomec / C&S ) | — | 4.00 | — | — | |
| — | — | — | Above/ 22232.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 4.00 | — | — | |
| — | — | — | Above/ 6048.00 Below/P | ||
| Dismanting / cutting of existing pole and make good of surface including transportation from site to stores | — | 18.00 | — | — | |
| — | — | — | Above/ 554.00 Below/P | ||
| Dismantling of old wiring including light, fan, plug, power plug, sub-main and main of different types of shed | — | 2.00 | — | — | |
| — | — | — | Above/ 45600.00 Below/P | ||
| Releasing of old, unused LT cables of various sizes | — | 1200.00 | — | — | |
| — | — | — | Above/ 79476.00 Below/P | ||
| Supply of Submersible dewatering (sewage) pump motor set of capacity 1.25 HP with delivery head 5 - 10 M and discharge capacity 50-200 LPM suitable for operation on 1Ph, 220-250V, 50Hz supply similar to Eterna, Make - KSB or equivalent. ( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama ) | — | 4.00 | — | — | |
| — | — | — | Above/ 83646.00 Below/P | ||
| Supply of Maintenance Free Copper Bonded Solid Earthing Rods with 25 kg Earth Enhance Compound with below specifications : a) Certified by CPRI and NABL Accredaited Lab b) ROHS certified c) Low Carbon High Tensile Rod d) Length of Electrode 3000 mm (3 Meter) e) Rod dia 17.2 mm f) Molecular Copper Plating thickness 254 microns as per UL 467 g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washer including installation, testing and commissioning as per RDSO spec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 9.00 | — | — | |
| — | — | — | Above/ 5886.00 Below/P | ||
| Supply of Heavy Duty Fiber Reinforced Polymers Pit Cover with below specifications : a) Weight Carrying Capacity 5 Ton b) Lockable arrangement c) Top Dia 162 mm d) Bottom Dia 242 mm e) Height 230 mm f) As per IEC 62561-5 g) M5 Nut Bolts HDG 4.6, 30 mm length with 2 nos. of plain washer h) Tested by NABL Accrediated LAB including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 9.00 | — | — | |
| — | — | — | Above/ 22383.00 Below/P | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 9.00 | — | — | |
| — | — | — | Above/ 3683839.00 Below/P | ||
| Goods & Services Tax ( at present @ 18% ) | — | 1.00 | Lumpsum | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
3625-RGeneralTenderClause.pdf
ATTACHMENT
3625-RAnnexure-A.pdf
ATTACHMENT
3625-RANNEXURE1.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
finalPassengerElevatorsignedRDSOREV- RDSO Spec
ATTACHMENT
TENDERBOOKLETFORLIFT9NOS.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
RDSOSpec.-2025-09-25-finalPassengerElevatorsignedRDSOREV-21.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .