Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Submitted all Required Document |
| 2 | Accepted-Technical | Accepted-Technical Submitted all Required Documents |
| 3 | Accepted-Technical 01 JAGDISH NIKUNJ LAKHIBAGH MANPUR GAYA BIHAR 823003 | GAYA | BIHAR | 823003 | Accepted-Technical Submitted all Required Documents |
| 4 | Rejected-Technical | Rejected-Technical Required document not submitted as per Tender document |
| 5 | Rejected-Technical 00 BARGO BARGO SENDULI BENDULI GORAKHPUR UTTAR PRADESH 273016 | GORAKHPUR | UTTAR PRADESH | 273016 | Rejected-Technical Required document not submitted as per Tender document |
Tender Value
₹24.3 L
EMD Value
₹48,639
Closing Date
15 Dec 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE,LGD-2
Executive Engineer, Lower Ganga Division-2, Central Water Commission, Adalatganj, Amarnath Road, Patna-1
Construction of Brick work Boundary Wall at UPPLK Gaya subdivision under LGD2, CWC, Patna
2025_CWC_888601_1
LGD-2/PAT/HQ-75/CIVIL WORK/2025/14
Open Tender
Civil Works
Works
Gaya
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹48,639
O/o EE,LGD-2,Patna
17 Dec 2025
5 Dec 2025
16 Dec 2025
5 Dec 2025
15 Dec 2025
6 Dec 2025
12 Dec 2025
Clearing jungle including uprooting of rank vegetation, grass, brushwood, trees and saplings of girth upto 30 cm measured at a height of1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil.For Column footing
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
Providing and laying in position specified grade of reinforced cement concrete (M20), excluding the cost of centering, shuttering, finishing and reinf,For Footing, For Column (above footing up to plinth)For Tie-Beam at ground level
Reinforced cement concrete work in beam,suspended floors,roofs having slope upto 15 degree landings,balconies,shelves,chajjas,lintels,bands,plain window sills,staircases and spiral stair cases above plinth level upto, up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3(1 cement :1.5 coarse sand (zone 111)derived from natural sources :3 graded stone aggregate 20mm nominal size derived from natural sources ) (for column )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level of grade FE 500D or more Footing, Tie beam ,column
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level of grade FE 500D or more Column
Form Work: Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Form Work: Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers
Form Work: Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix: 1:6 (1 cement: 6 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (In Gate)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.:On steel work ,For Gate
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
TenderGayaCPP.pdf
Tender Documents • 2.06 MB
BOQ_933985.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .