Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.0 LAccepted-AOC T V MALAI | ₹67.0 L | L1 | Accepted-AOC The lowest and negotiated tenderer |
| 2 | L2₹67.0 L+₹327.69 (<0.01%)Rejected-Finance NO 462 SATHIYAMOORTHI STREET CHEYYAR 604 407 THIRUVANNAMALAI DISTRICT | RANIPET | TAMIL NADU | 604407 | ₹67.0 L+₹327.69 (<0.01%) | L2 | Rejected-Finance Unsuccessful tenderer |
| 3 | L3₹69.3 L+₹2.3 L (3.41%)Rejected-Finance CHENNAI | CHENNAI | CHENNAI | TAMIL NADU | ₹69.3 L+₹2.3 L (3.41%) | L3 | Rejected-Finance Unsuccessful tenderer |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹49,400
Closing Date
12 Jul 2023, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Special Repair Works to existing permanent Police Recruitment School at Kolliyankulam in Villupuram District for the year 2023 2024
2023_TNPHC_335317_1
SE/NC/DB/1525/2023
Open Tender
Civil Works
Lump-sum
90 days
Kolliyankulam in Villupuram District
Refer the Tender documents
7 documents required · 7 mandatory
₹0
₹49,400
1 Aug 2023
4 Jul 2023
14 Jul 2023
4 Jul 2023
12 Jul 2023
4 Jul 2023
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
40 : Painting - New "wood work"
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
55.2 : Flat Back Urinal
Electrical arrangements 73.2 : 4 way - D.B
74 : Charges for fixing of "Fan"
86 : Anti termite treatment
112 : S & F of Exhaust Fan 300 mm dia
ANNEXURE-I 2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
6.5.1 : Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") (using crushed stone sand) with admixture
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) b) In Ground Floor
10.5.1 : Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 3/4" x 4 1/4"x 2 3/4") 110 mm tk (B.P.) (using crushed stone sand) with admixture b. In Ground Floor
c. In First Floor
d. In Second Floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
c. In First floor
d. In Second floor
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
23.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) with plasticizer
38.6 : One coat white cement for new walls and other similar works.
38.7 : Plastic Emulsion PAINT including primer for inner walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
53.5.2 : Wash Hand Basin of size 550 x 400 mm (white without pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
211: Clean removal of the old cement plastering both inside and outside from the existing walls of brick masonry and racking out joints to 20mm deep without damaging the existing structure.
214 : Dismantling the damaged brick / Stone masonry works in cement mortar without affecting the adjacent structures including the cost of required tools and plants and scaffolding etc.,
218: Dismantling the existing damaged one course pressed tile roof finish in cement mortar over RCC roof slab without affecting the adjacent structures in all floors including the cost of required tools and plants and clearing the debris away from the site
222: Removing the damaged broken door/window/ventilators including the removal of frames, hinges, fastenings and shutters form the existing structure
237: Providing two legged scaffolding using 15cm diameter casurina props and planks for the following height a) 5.5m height in addition of 2.5m ht
b) 8m height in addition of 2.5m ht
243: Dismantling the existing floor finishing without damaging the existing structure and daddoing in cement mortar with mosaic tiles / glazed tiles, clearing the debris away from the site including cost of loading, unloading & vehicle hire charges etc., all complete.
361.1 : Concrete designer tiles flooring (using crushed stone sand)
379.4.2.1: Supply and fixing of Granite slab of size 4'x2', 18 to 20mm Thick For kitchen arrangements (jet black) laid over in CM 1:3 (One of cement and three of crushed stone sand) 20mm thick a) In Ground Floor
383.4: Providing double nosing to the edges of granite slab of 18 to 20 mm thick including labour, power consumption, tools and plants required, true to horizontal in all floors in the laboratory work table and as directed by the departmental officers.
799 : Two coats of OBD over one coat white cement for inner walls
ANNEXURE -II A1: Supplying and fixing of LED bulbs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
A2: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A3: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings
A4: Supply and fixing of LED Bulk head fitting for 12W LED Bulb
A5: Pointing the top of roof for hydraulic pressed tiles as pointed neatly with the cement mortar 1:3 (One of cement and three of crushed stone sand) mixed with Water proofing compound as per standard specifications etc., all complete and as directed by the departmental officers.
A6: Painting ONE COAT OF OIL BOUND DISTEMPER over the old walls of approved brand including cost of paints, putty, brushes, watering, curing, thorough scrapping etc., all complete as directed by the departmental officers (paints and its shade shall be got approved from the Executive Engineer before use).
A7: Painting old walls with one coat of ready mixed PLASTIC EMULSION PAINT of first class quality paint of approved colour and shade for outer wall and other similar works, including cost of through scrapping necessary brushes, labour charges, patty etc., all complete as directed by the departmental officers.
A8: Painting the old wood work with one coat of approved first class enamel ready mixed paint in approved quality and shade including scrapping the old paint using sand paper, necessary brushes, labour charges etc., all complete as directed by the departmental officers.
A9: Painting the old Iron work and other similar works such as PVC / ASTM Pipes, Kerb Stone and grills with one coat of approved first class synthetic enamel ready mixed paint of approved quality and brand, the paint should be supplied by the contractor at his own cost, (The quality and the brand of paint should be got approved by the Executive Engineer before use) complying with relevant standard specifications.
A10: White washing One coat using clean shell lime slaked including cost of lime, gum, blue, brushes, including scaffolding etc., complete in all respects.
A11: Providing Melamine Polish for old wood work of doors & windows by removing existing polish and dirt by scrapping using water emery 320 paper to get smooth surface finish without patches on the existing door surface and polish two coats with Melamine Glozy mixed with necessary quantity of thinner (4 hrs interval for each coat) and after drying scrapping using Water emery 320 to get smooth surface after scrapping filled with patty for holes and after 8 hours polish with two coats of Melamine matt mixed with thinner 106 (4 hrs interval for each coat) to get smooth apperance including cost of brushes etc., all complete.
A12: Hire charges for deploying earth moving machinery (JCB/Poclain) for earthwork including diesel, oil and labour charges etc., complete.
A13: Supply and removing the existing damaged following electrical items with ISI mark and approved make including all cost etc., all complete and as directed by the departmental officers. a) Fan Step Regulator 100W - 2 Module
b) 5 Amps Switch (Flush type)
c) 5 Amps 3 Pin Top
d) Battern Type Bakelite Holder for Lamp
e) Hylem Sheet 3mm Thick
A14: Supply and removing the existing damaged following plumping items with ISI mark and approved make including all cost etc., all complete., a. 50mm Dia CP Angle Valve
b. 50mm Dia PVC Connection hose
A15: Labour Charges for removing and repairing the fan coil and replacement of bearing, assembling and fixing of existing ceiling fan of different sweep including labour charges and materials etc., all complete.
A16: Labour Charges for recoiling, assembling and fixing of existing AC exhaust fan of different sweep etc., all complete.
A17: Repair works in existing cupboard shutters etc., all complete & as directed by the departmental officers. a. Butt Hinges with Nylon Washers of size 100mm x 30mm (with required screws)
A18: Removing the damaged switch board and replacing the all cost etc., all complete.
A19: Supplying and fixing 6 A to 32 A, 10 KA single pole miniature circuit breaker (MCB) for outgoing breaker with ISI marked. The MCB will be fixed on the existing distribution box including labour charges for all inter connections etc., complete
A20: Supplying and fixing 63A,10KA Triple Pole miniature circuit breaker (MCB) for outgoing breaker with ISI marked. The MCB will be fixed on the existing distribution box including labour charges for all inter connections etc., complete.
A21: Cleaning the expansion joint (25x12mm) Provided in different places using wire brush to remove dust particles and packing the bituminis pad for the depth required (12.5mm) and mixing the part A and part B of Polysulphide sealent as per the manufacturer specification and filling the same in the expansion joint provided including fixing masking tape on either side of the groove to avoid over sticking and finishing the protion by using soap water. The rate including necessary scaffolding charges and cost of all chemicals tonls, plants and labour charges etc., complete.
A22: Supplying and fixing of EWC Cover including all cost etc. all complete complying with standard specification.
A23: Supply and delivery 3½ core 50 sqmm PVC insulated Aluminium armoured L.T U.G. cable ISI mark including cost of Transportational charges etc,. all Complete.
A24: Supply and providing the cable end termination of the following aluminium armoured U.G cable with suitable brass cable grand and necessary aluminium lugs, crimping with copper termination etc complete. a) 3½ core 50 sqmm
A25: Labour charges for conveying and laying of UG cables in the cable trench including earth work and providing sand cushion with brick layers below ground level etc., complete for UG cable of size 4 to 50 Sq.mm and 2, 3, 3 1/2, 4 core with ISI Mark etc., all complete and as directed by the departmental officers.
A26: Labour Charges for conveying and fixing of UG Cable of Size of 4 to 50 Sq.mm and 2, 3, 3 1/2 , 4 core with necessary MS clamps and brass screws including cost of materials and redoing the dismantled portion in to the original position etc., all complete and fixing of UG cables on walls and ceiling etc., all complete and as directed by the departmental officers.
A27: Supply and fixing of Aluminium Window, Door curtain rod including cost of materials and labour charges for fixing in position etc., all complete.
A28: Supplying and fixing of 300mm dia RCC Hume Pipe including transport charges and labour charges all cost etc., all complete.
A29: Supplying and Delivery of following Dia GI , GM , CI , PVC and MS SpecIals of best and approved quality having ISI mark including cost of specials and delivery at site of work etc., all complete and as directed by the departmental officers. a) 80mm Dia GI flange
b) 80mm Dia GI Elbow
c) 50mm Dia GI flange
d) 50mm Dia GI Elbow
e) 50 mm Dia GI Tee
f) 32mm Dia GI Hex Nipple
g) 50mm Dia GI Non Return Valve
h) Delivery line 32 mm UPVC Gate valve
i) 25mm UPVC Gate valve
j) 40mm Dia GI Hex Nipple
k) 40mm Dia GI Coupling
l) 40mm Dia GI Union
m) 40mm Dia GI Tee
n) 40mm Dia GI Elbow
o) 50mm Dia GM Gate valve
p) 50mm Dia GI Bend
q) 50mm Dia GI Coupling
r) 40mm x 32mm GI reducer
A30: Supplying and laying of following 50mm dia UPVC pipe of best and approved quality having ISI mark including cost of coveyance and delivery at site of work etc., all complete and as directed by the departmental officers. In Above Ground Level
A31: Supply and delivery of 12mm dia Nylon rope of best and approved quality for tying the delivery line with submersible pumpset for safety measure etc., all complete.
A32: Supply and delivery of 3 core 4.0 sqmm 1100V grade copper UG flat cable of best and approved quality having ISI mark etc., all complete as directed by the departmental officers.
A33: Supply and delivery of Three phase panel Board with two level guard auto start with ISI mark for 3 phase wall mounted type with ammeter, Voltmeter, Indicating lamps ON/OFF push bottons with necessary controls for submersible pump set running preventor relay suitable for the above including wire for fixing sensor and main switch with all respects and as directed by the departmental officers.
A34: Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth. Up to 5 HP.
A35: Supply and delivery of 3 HP Open well Submersible pump set conforming to IS14220 /2002. Duty IPM X M = 100 X 40 HP = 3 HP
A36: Supplying and Fixing of Aluminium Dye Cast Letters of approved size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes a) Aluminium Dye Cast Letters 9'' size
A37: Supplying and fixing of Health facet approved quality with ISI mark (Health facet shall be got approved from the E.E. before use) including all accessories etc. complete complying with relevant standard specifications and as directed by the departmental officers.
A38: Supplying and fixing of Shower with arm approved quality with ISI mark (Shawer shall be got approved from the E.E. before use) including all accessories etc. complete complying with relevant standard specifications and as directed by the departmental officers.
A39: Removing the existing coatings, plastering both vertical and horizontal and reaching the Surface Cleaning and making necessary surface preparation to remove any dust and laitance etc., chasing open the construction joints and sealing the same to form a U shaped groove of approx. 20mm width and 10mm depth, using polymer modified mortar using Dr Fixit Pidicrete URP, carrying out grouting at the construction joints, honeycombs, etc., by injecting cement slurry grout admixed with Dr. Fixit Pidicrete AM expandable grout additive to full saturation wherever necessary. All the junctions of floor and vertical sides in water tank portion shall be provided with cement-sand screed based angle fillet of 75 mm X 75 mm. The screed shall be admixed with Dr. Fixit Pidicrete URP a latex based additive ) dosage -1 liter / 50 kg cement bag ), Waterproofing Coating: Providing and Applying Dr. Fixit Fast flex in 2 coats with a consumption of 2Kg per Sq. m at specific time intervals of 6 to 8 Hrs once after base preparation of cleaning, brushing and removal of loose materials, grouting the porous area with grouting materials , proper carving between slab and wall junctions,, extending up to top of the wall including weld messh fabrication ,etc., and sprinkle fine sand on the vertical surface for plaster anchor still the second coat is wet. complete as per Manufacturer's methodology and specification.Protection Plastering/Screed: Providing Protection Plastering by with Cement Mortar 1:4 by admixing Dr Fixit Pidiproof LW+ Super with a dossage of 200ml per bag of cement.
A40: Acid washing the existing toilet floor tiles, wall tiles to make it dirt free including cost of materials and labours etc., all complete and as directed by the departmental officers.
R.SURESH BABU
A NARAYANAN
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_398395.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .