Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹11.2 L+₹33,361.50 (3.06%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹11.8 L+₹93,309 (8.57%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical DOCUMENTS ARE NOT IN ORDER |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
8 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS
GE 881 EWS C/o 56 APO
SPECIAL REPAIR TO BLDG NO T-49 AT POONCH AND SPECIAL REPAIR OF BLDG NO T-53 (COOK HOUSE) IN AOR OF STN HQ KG UNDER GE 881 EWS
2022_MES_499776_1
GE/PNH-64/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹26,000
Yes
21 Mar 2022
6 Jan 2022
10 Feb 2022
6 Jan 2022
8 Feb 2022
26 Jan 2022
60 days
Amount
B&R PORTION:- Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling mild steel work of any description complete all as specified and directed.
Demolition of concrete in ground floors and pavings (un reinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down plastering,hacking for key,raking out joints of brick work or stone work built in cement mortar,scrubbing down with water etc complete all as specified and directed.
Taking down chowkats or frames n exc 1.50 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frames with shutters exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from frame) complete all as specified and directed.
Dismantling or wall/ceiling board (fibre, pulp, insulation, etc) or insulation board.slabs/ blankets, of any thickness, including cover fillets complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tile to store and rubbish off the premises complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
S&F Mild Steel rolled section in purlin, main and cross beam, rafter,posts etc. incl connected cleats, hold fasts etc of grade conforming to Fe 410-W (Gde E-250 quality A) complete all as specified and directed.
S&F for MS work in small articles such as hook, pintle hinges, large hasps, staples, holdfasts,wind ties etc bent to shape with drilled holes for fixing screws nuts and bolts steel conforming to grade Fe-290 Gde-E-165 complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel & Iron surfaces, width or girth exceeding 10cm & apply two coats of synthetic enamel paint of 1st quality over a coat of red oxide zinc chrome complete all as specified and directed.
S&F Suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 3mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) fibre cement E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips, complete all as specified and directed. Make:- Everest Industries Ltd or equivalent as approved by GE.
M & L for Walling of random rubble, Brought upto course, built in CM 1:6 complete all as specified and directed.
All as per item No 16 above but except stone complete all as specified and directed.
M&L for coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 Sqm but n.exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & incl 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed.
All as per Item No. 18 above but in vertical surfaces such as skirtings, dados and risers to steps etc including 10 mm thick rending in CM (1:4) complet all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing & incl 20mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab in riser of steps, skirting,dado and pillar laid over cement screed base laid and jointed with grewy cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 10 mm thick rendering in CM (1:4) complet all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl rounding of edge laid over 15mm thick screed bed in CM (1:6) including rounding of edge of stone slabs one edge, complete all as specified and directed.
M&L for Preparation of wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections including cleaning, threading for refixing or removal to store, complete all as specified and directed.
S & F Galvanized steel water tubing, 15 mm bore, medium grade, with all fittings , fixed complete to walls, ceilings or laid in floors complete all as specified and directed.
S&F in repair Bib tap fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair Stop valve/angle valve cast copper alloy,chromium plated with capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions complete all as specified and directed.
S & F Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 complete all as specified and directed.
S&F Vitreous China wash basin, white, flat back, size 630 x 450 mm excluding taps, wastes, chain and plug and porcelain but including brackets complete all as specified and directed.
S&F in repair 15mm pillar taps fancy type, cast copper alloy , with capstan heads, chromium plated, screw down high pressure with long screwed shanks and fly nuts, screwed for iron pipes complete all as specified and directed.
S&F 32mm bore PVC waste pipe complete all as specified and directed.
Dismantling water tanks of any size or capacity and removing to store not exceedding 500 lit capacity complete all as specified and directed.
S & F rotational moulded synthetic (HDPE), water storage tank 500 litre capacity (cylinderical vertical with closed top,) hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed.
M & L for RCC 1:1.5:3 Type A1 (20mm graded agg) as in plinth band/lintel band, bressummers, chajjas, shelves, platform etc and similar works complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams rough finished surfaces of concrete complete all as specified and directed.
M&L for reinforcement with 6 to 8mm dia and over TMT bars cut to length, bend to shape reqd, including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for cement concrete 1:3:6 (Nominal mix) type C 1 using 20mm graded aggregate as in surface channels and drain complete all as specified and directed.
Extra for fair finished drain or channel 30cm and over in girth in Cement concrete using extra cement including forms moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for chequered cement concrete tiles with mixture of white and grey cement in equal proportion and no pigments of size 30cmx30cmx25 mm thick,set, jointed and pointed in neat cement surry in floors including 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and diected.
M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed.
M & L PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or stone masonary surfaces 15mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for rendering stone masonary surfaces 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper over a coat of 1mm thick wall putty complete all as specified and directed
S & F pressed steel frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges 100mm long , 03 Nos each for double shutters, lock strike plate etc complete all as specified and directed.
S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated shash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a), supplied & fitted to chowkats complete all as specified and directed.
S & F 35 mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board, medium density, wood particle board with commercial face veneered supplied & fitted to chowkat complete all as specified and directed.
S&F Box type Steel window/ ventilator comprised of tubuler frame and shutter made out of 1.25 mm thick MS sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter combination with side hung / top hung shuter with MS handle and MS peg stay dovetailed or welded incl 02 Nos , MS Tower bolts 150 mm long for each leaf and 08 mm square bar grill / guard bars at spacing directed welded to MS flat iron frame work,PCC blocks for hold fast etc., complete all as specified and directed by Engr-in-Charge
M&L for PCC ,1:2:4 type B0, using 12.5 mm crushed agg as in bed blocks for embedding hold fast etc complete all as specified and directed.
S & F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S & F 100 mm butt hinges, medium weight cold rolled mild steel and fixed, complete all as specified and directed.
S & F IInd class hard wood for small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labour articles not exc 200 cu.cm each, complete all as specified and directed.
S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
S&F in repair 25mm dia MS powder coated tublar curtain rod, fancy type, complete all as specified and directed.
S&F MS powder colour coated, decorative type knobs with bracket of fixing at end of pelmet rod suitable for 25mm dia, complete all as specified and directed.
M&L for preparation of wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in unframed work, complete all as specified and directed.
S&F for 2nd class soft wood (kail) as in scantling clean sawn and fitted in unframed works complete all as specified and directed.
M&L for rendering 20 mm thick on stone masonry surface or other than fair face of brick work or on one side of lathing finished even & smooth without using extra cement in CM 1:6, complete all as specified and directed.
M&L for rendering 20 mm thick on stone masonry surface or other than fair face of brick work or on one side of lathing finished even & smooth without using extra cement in CM 1:4, complete all as specified and directed.
M&L for two coats of oil bound distemper on new/un treated plastered surfaces including preparation of wall complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8, type C-1, using 40 mm graded aggregates as in sub base of path etc, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 2nd class hard wood for plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and directed.
S&F in repairs of 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F 125mm long aluminium anodised tower bolts complete all as specified and directed.
S&F 125mm size aluminium anodised door handles complete all as specified and directed.
S&F 75mm long aluminium anodised tower bolts complete all as specified and directed.
S&F 75 mm long mild steel butt hinges, medium weight, cold rolled complete all as specified and directed.
S&F 100 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S&F 300mm long alluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded section and fixing bolts and sliding of extruded section complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S & F 6 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid Size of grid 605 x 605mm of anodised aluminium snap grid frame work for false ceiling alongwith Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc for one light point controlled by one way switch 6 Amp complete all as specified and as directed.
All as per item No 81 above but one fan point (Ceiling and exhaust) controlled by one way switch 6 Amp complete all as specified and directed.
All as per item No 81 above but one 5 pin, 6 Amp socket outlet on the same board complete all as specified and directed.
All as per item No 81 above but one 5 pin, 6 Amp socket outlet on the independent board complete all as specified and directed.
All as per srl item No 81 above but for one 3 pin socket outlet 15 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair Ceiling rose, 3 phase PVC/poly carbonate, insulated body, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair socket outlet multipurpose 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings including 10 watt LED lamp B22 base, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed. Make:-Havells/Anchor/Legrand
S&F in repair Tube light fitting box type suitable for LED 20W tube rod made out of ultra bright, glass shell, glare free, wide angle, single side connection retofit LED tube with G13 lamp holders complete with hosing with all accessories pre wired and making connection with copper flexible cable of appropriate size from ceiling rose to light fitting including 20LED tube rod 4 feet long with single side connection complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LHFXCEP1TNNW020 for batten fittings or Equivalent cat part of make as specified in PS. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair LED luminaire 600mmx600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light, complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 4 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW04 or Equivalent cat part of make as specified in P.S.
S&F Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make as specified in P.S.
S&F MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 16 sqmm including taking down complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
M&L for Approved quality clean dry sharp sand as in cushioning to under ground cable laying 15cm thick before laying and 8cm after laying the cable in trenches for cable cushioning, complete all as specified and directed.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed.
Removal of excavated soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Supply and laying GI tubes light grade ISI marked , galvanized, 40mm bore laid in trenches or under floor or fixed with poles/ walls for protection of electric cable complete all as specified and as directed.
S&F Sub main wiring with single core cable 2x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 2.5 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 4 sqmm, 1 wire of 2.5 sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
M/S BADRI NATH GUPTA
M/S FAIZ AHMED KHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .