| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.0 L+₹4.1 L (14.0%)Rejected-Finance NO 7A MULLAI NAGAR MAIN RD WEST TAMBARAM CHENNAI 600 045 | CHENGALPATTU | TAMIL NADU | 600045 | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | ragavbuilders L2 | Raju Builders L1 |
|---|---|---|---|---|---|
| 1.00 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge. | 5 | Cum | 380 ₹1,900 Lowest | 450 ₹2,250 |
| 2.00 | M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge. | 2 | Cum | 5,800 ₹11,600 Lowest | 6,300 ₹12,600 |
| 3.00 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. | 3 | Sqm | 630 ₹1,890 Lowest | 720 ₹2,160 |
| 4.00 | M& L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge. | 25 | Sqm | 35 ₹875 | 27 ₹675 Lowest |
| 5.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 123 | Sqm | 65 ₹7,995 | 54 ₹6,642 Lowest |
| 6.00 | S&F glazed ceramic tiles in vertical surface 300x 450x 7mm/ 350X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick complete all as specified and directed by Engineer-in-Charge. | 35 | Sqm | 1,350 ₹47,250 | 1,260 ₹44,100 Lowest |
| 7.00 | S&F Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. over and including 15 mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge. | 25 | Sqm | 1,350 ₹33,750 | 1,260 ₹31,500 Lowest |
| 8.00 | S&F Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. over and including 15 mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge. | 88 | Sqm | 1,350 ₹1,18,800 | 1,260 ₹1,10,880 Lowest |
| 9.00 | M&L Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set,
jointed and pointed in chemical resistant mortar, resin type, in floors complete all as specified and directed by Engineer-in-Charge. | 25 | Sqm | 3,100 ₹77,500 | 2,700 ₹67,500 Lowest |
| 10.00 | Taking down chowkats/Frames of area n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge. | 20 | Each | 150 ₹3,000 | 126 ₹2,520 Lowest |
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
12 Mar 2026, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
SPL REPAIRS TO BCR AT AFS TAMBARAM
2026_MES_753322_1
GE(AF)/TBM/8877/E8
Open Tender
Civil Works
Item Rate
180 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹66,600
Yes
9 May 2026
19 Feb 2026
14 Mar 2026
19 Feb 2026
12 Mar 2026
5 Mar 2026
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M& L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
S&F glazed ceramic tiles in vertical surface 300x 450x 7mm/ 350X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick complete all as specified and directed by Engineer-in-Charge.
S&F Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. over and including 15 mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
S&F Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. over and including 15 mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats/Frames of area n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats/Frames of area .exc 1.5 Sqmand not exe 4.00 sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
Supply and fix fixing aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for windows/ Doors/Ventilators/Particians with one or more tracks including joining cleats/ channel for fixing glass/ mesh complete all as specified and directed by Engineer-in-Charge.
S&F for Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed by Engineer-in-Charge. Note : Prelaminated particle board and wire mesh shall be measured and paid separately.
S F Aluminium powder coated (minimum thickness of powder coating 50 micron) side hung/sliding window/ ventilators shutters (I max) of aluminium section for frame work of shutters not less than 0.55 Kg/RM including necessary jointing cleats glazing clips, rubber packing anodised aluminium snap beads, screw, roller inter locking handles including 75 mm SS Hinges-02 Nos, 125 mm handles - 01 No, 125 mm long tower bolts - 02 Nos each shutter etc complete all as specified and directed by Engineer-in-Charge. Note : Glass panes and wire mesh will be measured and paid separately
S&F aluminium alloy wire mesh 0.45mm nominal dia of wire and any width of aperture 1.4mm fixed with alu wire staples fixed to wood/steel frames complete all as specified and directed by Engineer-in-Charge.
M&L for pre laminated particle board 12 mm thick interior grade Prelaminated one side with decorative choice lamination and other side balancing white lamination with lipping as in doors of cupboards and cabinets complete all as specified and directed by Engineer-in-Charge.
S&F in 4mm Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F in 4mm Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification &drawing complete all as specified and directed by Engineer-in-Charge.
S&F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium anodised,125mm long barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Extruded aluminium alloy handles,150mm long fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long stainless steel butt hinges for PVC doors complete all as specified and directed by Engineer-in-Charge.
Demolition of plain cement concrete in floors (other than ground floors) and similar suspended works including disposal of demolished materials exc 500m but n.exc 1000m complete all as specified and directed by Engineer-in-Charge.
Removing existing water proofing treatment and applying water proofing treatment on horizontal or vertical surfaces by applying oil bound bitumen primer @ 0.20 Kg/sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4 Kg/sqm reinforced with non-woven polyester matt weighing not less than 160 gm/sqm including minimum 10cm side lap and 15 cm end lap torch sealed and bonded and applying a coat of blown grade hot bitumen 90/15 over and below the membrane @ 1.20 Kg/sqm in drying over the membrane finished with solar reflective bituminous aluminium paint/ primer @ 0.10 Kg/sqm over RCC roof slab/ parapet after cleaning the surfaces by removing dust, dirt etc., as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge. Note : This work shall be executed through authorised applicator of APP membrane manufacturer and a certificate in this regard shall need to be submitted by contractor before the start of execution.
M&L Plain Cement Concrete as in roof padding type B0,Nominal mix (1:2:4) using 12.5 mm graded aggregate including formwork complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10mm thick in CM 1:4 with water proofing compound @ 3% by weight of cement over RCC slab, parapet and the like etc. finishing fair and even complete all as specified and directed by Engineer-in-Charge. Note: WPC will be measured and paid separately.
Supply only Liquid water proofing compound
S&F in repair door closer, aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80kg complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Wash down water closet (Pedestal pattern) white with P or S trap including plastic water closet seat & cover mild steel chromium plated or aluminised hinging device, flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for high/low level cistern etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC valve less, syphonic action type of 10 litre capacity, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC connections of 15mm size with PTMT nuts of length 600mm etc, complete all as specified and directed by Engineer-in-Charge.
M&L PTMT Bottle trap half or full threaded bore of discharge pipe 32mm,min weight 260gm fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 600x450 bevelled edged looking mirror 6mm thick with Design wooden frame work fitted with 6mm thick commercial ply or AC sheet backing to mirror complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repairs Health faucet ABS body 15mm dia pipe with 1.25metre long PVC tube with wall hook, Chromium Plated all as specified and directed.
Supply and fixed in repairs towel rail 600mm long with flanges, chromium plated complete all as specified and directed by Engineer-in-Charge.
S&F for in repairs angular two way stop cock 15 mm bore chromium plated with crutch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union fixed as in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm dia chromium plated fancy type angle/stop cock cast copper alloy screwed down high pressure fancy screwed both ends for pipe or for union complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china WHB flat back of size 550x400mm incl GI Brackets, CP brass waste coupling with check nut and washers of suitable size complete all as specified and directed by Engineer-in-Charge.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm bore CP Bib tap cast copper alloy fancy type crutch or butterfly handles screwed down for iron or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm bore brass Chromium plated fancy type bib Taps long shank with flange, crutch or butterfly handle, screwed down , screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China urinals, half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed by Engineer-in-Charge. Note : The quoted rate is exclusive of fixing of supply pipe to flushing cistern, trap and waste pipe.
S&F Urinal spreader of CP any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connections 15mm dia 600mm long (for cold/hot water connection with brass or PTMT flynuts and washer at both ends complete all as specified and directed by Engineer-in-Charge.
S&F for over head shower rose & shower arm with revolving joint and 100mm dia round shaped single flow (ABS body chromium plated all fixed in repair complete all as specified and directed by Engineer-in-Charge.
Taking down rain water pipes, waste/soil pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc including cleaning or refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 100mm dia SS floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
Taking down of 15mm steel tubing and connections complete on walls floors etc complete all as specified and directed by Engineer-in-Charge.
All as per item No.53 above but bore of pipe in 20mm dia complete all as specified and directed by Engineer-in-Charge.
All as per item No.53 above but bore of pipe in 25mm dia complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engineer-in-Charge. Note : cutting of chases in wall masonry shall be measured and paid separately.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engineer-in-Charge. Note : cutting of chases in wall masonry shall be measured and paid separately.
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engineer-in-Charge. Note : cutting of chases in wall masonry shall be measured and paid separately.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and directed by Engineer-in-Charge.
S&F in repairs flush pipe of polyethylene of low or high density or PVC 32 mm dia, for wash hand basin / urinal complete all as specified and directed by Engineer-in-Charge.
Taking down old cement plaster including racking out joint hacking for keys and scrubbing down with water etc., on wall/ ceiling surfaces and removing the debris from the defence premises complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on brick/ concrete surfaces with CM 1:4, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5mm thick on ceiling surfaces with CM 1:3, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new surfaces of external walls and applying one coat of primer and two coats of weather proof exterior emulsion paint (weather coat Apex, 100% exterior grade) complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of ceiling by sand papering or by any other means, preparing the surfaces smooth and after that applying three coats of lime white wash with using paint brush complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new surfaces of walls and applying one coat of primer and two coats of Oil Bound Distemper complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new surfaces of external walls and applying one coat of primer and two coats of weather proof exterior emulsion paint (weather coat Apex, 100% exterior grade) complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of wall, including Washing, rubbing down and stopping of distempered and painted surfaces of pilasters, including cornices and applying two coats of Oil Bound Distemper over a coat of alkali resistance primer including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment of walls/pillars /cornices, including Washing, rubbing down including applying white cement based putty where required for filling to depressions to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, after preparing the surfaces applying two coats of weather proof exterior emulsion paint (weather coat Apex, 100% exterior grade), as per existing or as approved tint/colour complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old decorated surfaces of ceiling and applying one coat of white wash evenly complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old decorated surfaces of wood work exc. 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing Old Steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F PVC down take pipe,32 mm for WHB/urinals complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment and applying two coats of acid resistance paint over a coat of primer on surfaces of any description wood, steel, iron, concrete, brick, stone, etc exceeding 10cm in width or girth complete all as specified and directed by Engineer-in-Charge.
Dismantling AC corrugated or semi corrugated sheets in roof covering / wall cladding complete all as specified and directed by Engineer-in-Charge.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats/wind ties etc of confirming to Fe 410-W(Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new Steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes ( or similar holes ) each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 metre complete all as specified and directed by Engineer-in-Charge.
M&L Plain Cement Concrete, 1:2:4, type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed by Engineer-in-Charge.
S & F Mild steel work in tubular trusses, posts including special shaped washer etc. complete using ERW or including butt welded tubes conforming to I.S.1161-1998 grade St-240 complete all as specified and directed by Engineer-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out in soft / loose soils complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 75mm plain Cement concrete type C- 2, 1:3:6, nominal mix (40 mm graded aggregate) complete all as specified and directed by Engineer in Charge.
M&L for Plain Cement Concrete type B- 1, 1:2:4 (20mm graded aggregate) 100mm, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed in side md land complete all as specified and directed by Engineer-in-Charge.
M&L Block boards, grade 1 quality,35mm thick exterior grade, decorative type with decorative face veneer on one face complete all as specified and directed by Engineer-in-Charge.
M&L for Chamfering or rounding edges of hard boards complete all as specified and directed by Engineer-in-Charge.
S&F Rolled steel sections Fe 410 -W (Grade E- 250) quality A as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Rotational moulded Triple layer ISI marked polyethylene water storage tank (cylindrical Vertical with closed top) hoisted and fixed in position all as specified 1000 Litre Capacity and dismantling old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 25mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slabs and tiles of any description or thickness laid bedded and pointed in floors, aprons etc complete all as specified and directed by Engineer-in-Charge.
M&L for Sand filling under paver blocks including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for rubber moulded machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness,M-35 Grade with grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M &L Point wiring concealed/ surface mounted with 1.5 sqmm single core PVC insulated FRLS 1100 volts grade with copper conductor drawn in and including non metallic rigid PVC conduit and all conduit accessories, provision of MS terminal box and modular frame and plates for housing modular switches / sockets / regulators etc, including 1.5 Sqmm PVC insulated multi stranded copper earth continuity conductor connecting to the common earth dolly etc complete for the following:- Note: (i) The rates including modular cover plates and frame in sizes complete as per requirement .
One light point controlled by one switch
One fan point controlled by one switch
One 3 pin 5 Amps socket outlet on same board
One 3 pin 5 Amps socket outlet on independent board
one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
one 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size.
Supply and fix of Modular switch 1 way 6A, 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular switch 1 way 16A, 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular socket 6 A 3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular socket 6A/16A 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC ceiling rose three plate surface and jumpo type complete all as specified and directed by Engineer-in-Charge.
M & L for circuit/sub main wiring complete with 4 X 10 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 2 X 10 Sqmm of PVC FRLS copper cable for earth continuity, dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge.
M & L for circuit/sub main wiring complete with 4 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 2 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge.
M & L for circuit/sub main wiring complete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge.
M & L for circuit/sub main wiring complete with 2 X 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed by Engineer-in-Charge.
S&F LED lights fitting 1x 20W, 220V, Suspended architectural LED luminare provides soft-light and glare free symmetrical illumination with (continuous mounting end cap connecting up with three core flexible copper conductor including disconecting, removing and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 22 W LED (4 ft) lamp including disconnecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Mirror light fitting LED luminares New generation energy saving IP65 Mirror light luminaire with opal diffuser with 10W LED including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35W LED 5000K lamp including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50metre long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unserviceable GI bracket complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of flood light fittings LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 150W LED 5000K lamp including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix, of MCB DB SPN, double door, 8 way 240 V with 200 A rated bus bar neutral link, earth link complete all as specified and directed by Engineer-in-Charge.
Supply and fix of MCB DB SPN, double door, 12 way 240 V with 200 A rated bus bar neutral link, earth link complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Vertical type sheet metal enclosure MCCB DB TPN 8 ways double door type including 100 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Vertical type sheet metal enclosure MCCB DB 4 ways double door type including 63 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB Single Pole 06 to 32 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCB SPN 0- 40 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Isolator TP 63 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix industrial panel mounted 16 Amps rating ,2P+E single phase ,plug socket suitable for IP 67 degree of protection with suitable enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fix industrial panel mounted 32 Amps rating 2P+E ,single phase, plug socket suitable for IP 67 degree of protection with suitable enclosure complete all as specified and directed by Engineer-in-Charge.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver including proper fixing arrangements complete all as specified and directed by Engineer-in-Charge.
Supply & fix Ceiling fan complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated including proper fixing arranggements complete all as specified and directed by Engineer-in-Charge.
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting including proper fixing arrangements complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4.0 mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point including testing and commissioning on completion complete all as specified and directed by Engineer-in-Charge.
M&L in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4.0 mm thick for inter connecting of earth electrodes complete all as specified and directed by Engineer-in-Charge.
S&F PVC non metallic rigid conduit not less than 20 mm dia with its conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
M&L Ceiling fan hook made out of MS bar 10 mm dia bar bend to shape or anchor fastener with hook for shifting/hanging ceiling fans complete all as specified and directed by Engineer-in-Charge.
Taking down Split AC up to 2.0 Ton complete with indoor & out door units and deposit to E/m store for safe custody including electrical connections complete all as directed
M&L for refixing the split AC up to 2.0 Ton colecting from E/M store after completed the B/R work including necessary servicing, gas top up & replacement of minor spares if required complete all as directed.
Taking down sub main wiring any description along with PVC conduit/Casing capping/wooden batten/metal conduit and made good the disturbed surface all as specified.
Taking down unserviceable DB/metal clad boxes any description or size/way including MCCB/MCBs complete.
Taking down existing fan, ceiling cable end, dismantling blades and removing fan and blades to store for Serviceable one for reuse & Un serviceable one for BER process.
Hanging/Refixing only ceiling fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified.
Taking down Exhaust fan, ceiling rose, dismantling blades and removing fan and blades to store.for Servicable one for reuse & Un serviceable.one for BER rpocess.
Refixing only Exhaust fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified.
M & L for painting of ceiling fan/exhaust fan any sweep, complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
Taking down old aluminium point wiring (light, fan, socket or power) complete fittings such as switches,sockets,ceiling rose, pendents, regulators etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc. complete all as directed and specified.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300/400m sweep with, blades, and frame and louvers
FOR FLAME PROOF AREA M &L Point wiring with 1.5 sqmm single core PVC insulated FRLS 1100 volts grade with copper conductor drawn in and steel conduit and all conduit accessories provision of MS terminal box suitable for flame proof switch etc, including 1.5 Sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete for the following.
One light/Fan point controlled by one switch
One 3 pin 5 Amps socket outlet on independent board
one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V including proper fixing arrangements complete all as specified and directed by Engineer-in-Charge.
S&F Switch flame proof rotary type with termination box in LM6, 25A,double pole 250V including proper fixing arrangements complete all as specified and directed by Engineer-in-Charge.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth including proper fixing arranggements complete all as specified and directed by Engineer-in-Charge.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth including proper fixing arranggements complete all as directed.
Supply and fix Flame proof - weather proof switch socket & plug combined 25 A, 500 V(3P+Earth) including proper fixing arranggements complete all as directed.
Supply and fix Flame proof weather proof fan regulator suitable for 1200/.1400mm sweep ceiling fans including proper fixing arranggements complete all as directed.
Supply and fixing in repair LED light fitting 2 X 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and Fixing in repair Flameproof LED false ceiling light fitting of 40W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting upwith three core flexible copper conductor cable with suitable size.
M & L for circuit/sub main wiring complete with 2 X 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through steel conduit and accessories on surface/ concealed of wall roofs etc with1 X 1.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed by Engineer- in- charge.
M & L for circuit/sub main wiring complete with 2 X 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through steel conduit and accessories on surface/ concealed of wall roofs etc with1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed by Engineer- in- charge.
M & L for circuit/sub main wiring complete with 4 X6.0 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through steel conduit and accessories on surface/ concealed of wall roofs etc with1 X 6.0 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed by Engineer- in- charge.
S&F Stove enamelled steel conduit of size 25mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender8877.pdf
Tender Documents • 0.66 MB
PS8877.pdf
Additional Documents • 0.60 MB
BOQ_843767.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .